Repairs Maintenance Rewinding Of Ceiling Fans , Air Circulators Wall Mounting Fans , Solar Water Heaters And Geyser At Air Force Station Bidar ., GE (AF) Bidar-Karnataka

Military Engineer Services-MES has published Repairs Maintenance Rewinding Of Ceiling Fans , Air Circulators Wall Mounting Fans , Solar Water Heaters And Geyser At Air Force Station Bidar .. Submission Date for this Tender is 21-08-2020. Electrical Maintenance Tenders in GE (AF) Bidar Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

25046406
Repairs Maintenance Rewinding Of Ceiling Fans , Air Circulators Wall Mounting Fans , Solar Water Heaters And Geyser At Air Force Station Bidar .
Open Tender
Indian
Karnataka
GE (AF) Bidar
21-08-2020

Tender Details

Repairs Maintenance Rewinding Of Ceiling Fans , Air Circulators Wall Mounting Fans , Solar Water Heaters And Geyser At Air Force Station Bidar .

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: Repairs/Maint/Rewinding of Ceiling fans, Air circulators/ Wall mounting fans, Solar water heaters and Geyser at Air Force Station Bidar
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down of ceiling fan of sweep 1200/1400mm of any make from any height of the building for maintenance and safety checking and fixing back the same in its original position all as specified and as directed.\nNote:- (i) Defective/unserviceable minor accessories like rubber real, clamps, bolts, nuts, washers, safety pin etc will be measured and paid separately under supply only. The labour element required for replacing the spares shall be deemed to be included in the unit rate quoted\n(ii) Rewinding /overhauling of fans measured seperately. BI01010001010000000000000515BI0100001113 850 Each job
2 2 Supply only Rubber real bushes for ceiling fan of sweep 1200/1400mm BI01010001010000000000000515BI0100001114 300 Each
3 3 Supply only Safety pins with nuts and bolt with washers for ceiling fan BI01010001010000000000000515BI0100001115 152 Each
4 4 Oiling and greasing for ceiling fan BI01010001010000000000000515BI0100001116 350 Each
5 5 Supply only blades of ceiling fan of any size BI01010001010000000000000515BI0100001117 150 Set of three
6 6 Supply only ceiling fan canopies BI01010001010000000000000515BI0100001118 100 Set of two
7 7 Preparation of surface and spray painting the Ceiling fan unit of sweep 1200 /1400mm (consisting of Fan motor, blades, canopy and downrod) with one coat of synthetic enamel paint of existing colour and marking the MES number on the fan motor with suitable paints all as directed. \n BI01010001010000000000000515BI0100001119 250 Each
8 8 Disconnection and removing the unserviceable winding from the ceiling fan motor of any sweep cleaning the slots and rewinding the same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. BI01010001010000000000000515BI0100001120 600 Each
9 9 S&F in repair fan bearing of suitable size for ceiling fan 1200mm /1400 mm sweep BI01010001010000000000000515BI0100001121 500 Each
10 10 S&F in repair fan bush of suitable size for ceiling fan 1200mm /1400 mm sweep BI01010001010000000000000515BI0100001122 500 Each
11 11 Servicing of pedastal fan of any sweep from the location / MES store or shifting from site /MES store to work shop, disconnection and removing the unserviceable winding from the motor cleaning the slots and rewinding with suitable gauge super enamelled copper winding wire, insulating and heating properly testing and commissioning complete all as directed. BI01010001010000000000000515BI0100001123 30 Each
12 12 S&F in repair bearing of suitable size for pedastal fan of 630 mm sweep BI01010001010000000000000515BI0100001124 15 Each
13 13 S&F in repairs bush of suitable size for pedastal fan of any sweep BI01010001010000000000000515BI0100001125 15 Each
14 14 Preparation of surface and spray painting the pedastal fan 630mm sweep with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints complete all as directed.\n BI01010001010000000000000515BI0100001126 15 Each
15 15 Taking down of wall mounted fan of sweep 630/450/400mm of any make from any height of the building for maintenance and safety checking, refixing in original position, reconnecting the cables and testing complete all as directed.\nNote:- Defective/unserviceable minor accessories like rubber real, clamps, bolts, nuts, washers, safety pin etc will be measured and paid separately. BI01010001010000000000000515BI0100001127 120 Each Job
16 16 Disconnection and removing the unserviceable winding from the motor of wall mounted fan of sweep 630mm, cleaning the slots and rewinding the same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. BI01010001010000000000000515BI0100001128 50 Each Job
17 17 S&F in repairs bearing of suitable size for wall mounted fan of 400 mm sweep.\n BI01010001010000000000000515BI0100001129 30 Each
18 18 S&F in repairs fan bush of suitable size for wall mounted fan of the any sweep BI01010001010000000000000515BI0100001130 30 Each
19 19 Taking down of exhaust fan of sweep 450/300mm of any make from any height of the building for maintenance and safety checking, reconnecting in original position, reconnecting the cables and testing complete all as directed.. \nNote:- Defective/unserviceable minor accessories like rubber real, clamps, bolts, nuts, washers, safety pin etc will be measured and paid separately. BI01010001010000000000000515BI0100001131 150 Each Job
20 20 Disconnection and removing the unserviceable winding from the motor of exhaust fan of sweep 450mm, cleaning the slots and rewinding the same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. BI01010001010000000000000515BI0100001132 50 Each Job
21 21 Disconnection and removing the unserviceable winding from the motor of exhaust fan of sweep 300mm, cleaning the slots and rewinding the same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. BI01010001010000000000000515BI0100001133 50 Each Job
22 22 S&F in repairs fan bearing of suitable size for exhaust fan of 450 mm sweep including greasing. BI01010001010000000000000515BI0100001134 50 Each
23 23 S&F in repairs fan bearing of suitable size for exhaust fan of 300 mm sweep including greasing. BI01010001010000000000000515BI0100001135 50 Each
24 24 S&F in repairs fan bush of suitable size for exhaust fan of 450 mm sweep BI01010001010000000000000515BI0100001136 50 Each
25 25 S&F in repairs fan bush of suitable size for exhaust fan of 300 mm sweep BI01010001010000000000000515BI0100001137 50 Each
26 26 Preparation of surface and spray painting the exhaust fan 450mm sweep with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints including required shifting complete all as directed.\n BI01010001010000000000000515BI0100001138 25 Each
27 27 Preparation of surface and spray painting the exhaust fan 300mm sweep with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints including required shifting complete all as directed.\n BI01010001010000000000000515BI0100001139 25 Each
28 28 S&F in repairs the 2.5 MFD capacity ceiling /exhaust fan condensors BI01010001010000000000000515BI0100001140 700 Each
29 29 S&F in repairs the 4 MFD capacity ceiling /exhaust fan condensors BI01010001010000000000000515BI0100001141 100 Each
30 30 S&F in repairs fan regulator electronic stepper type 100-300W, 230V, AC 50 Hz, Socket model BI01010001010000000000000515BI0100001142 300 Each
31 31 S&F in repairs metal louvers of suitable size for exhaust fan of 450 mm sweep BI01010001010000000000000515BI0100001143 10 Each
32 32 S&F in repairs metal louvers of suitable size for exhaust fan of 300 mm sweep BI01010001010000000000000515BI0100001144 10 Each
33 33 Supply and replacement of down rod of 2 to 3 feet length for ceiling fan with 15mm dia GI pipe medium grade, screwed and drilled with clamps rubber real, nut , bolts, and safty pin etc including painting complete all as directed. BI01010001010000000000000515BI0100001145 35 Each
34 34 Taking down carefully storage water heater (geyser) 25 Ltr/35 ltr /50 Ltr from the location by removing the electrical connecton and water connections, shifted to work shop / MES Store as directed.\nNote :- Replacement of defective spares will be measured and paid under relevant items mentioned here in after separately. BI01010001010000000000000515BI0100001146 100 Each Job
35 35 Supply and replacement of heating coil 1500 W including rubber washer/packing suitable for geyser. Make:- Theeta/Swarna (ISI Marked) BI01010001010000000000000515BI0100001147 70 Each
36 36 Supply and replacement of heating coil 2000 W including rubber washer/packing suitable for geyser. Make:- Theeta/Swarna (ISI Marked) BI01010001010000000000000515BI0100001148 15 Each
37 37 Supply and replacement of thermostat range of 30-80 degree suitable for geyser of 25/35/50 litres capacity BI01010001010000000000000515BI0100001149 100 Each
38 38 Brazing of inner copper tank of Geysers using good quality of copper electrode blow lamp welding process, brazing length n.exc 10 cm complete all as directed. BI01010001010000000000000515BI0100001150 35 Each
39 39 Supply and replacement of glass wool for insulator of Geysers any capacity and any make complete all as directed. BI01010001010000000000000515BI0100001151 5 KG
40 40 Supply and replacement of pressure relief valve CP brass suitable 15mm size BI01010001010000000000000515BI0100001152 25 Each
41 41 Supply and replacement of Non return valve brass suitable 15mm size BI01010001010000000000000515BI0100001153 25 Each
42 42 Supply and replacement of indicator lamp suitable for storage water heater (geyser) 25 /35/50 Ltr BI01010001010000000000000515BI0100001154 100 Each
43 43 Preparation of surface and spray painting the storage water heater (geyser) 25 /35 Ltr with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints complete all as directed.\n BI01010001010000000000000515BI0100001155 25 Each
44 44 Preparation of surface and spray painting the storage water heater (geyser) 50 Ltr with one coat of synthetic enamel paint of existing colour and B58marking the MES number with suitable paints complete all as directed.\n BI01010001010000000000000515BI0100001156 25 Each
45 45 Supply and replacement of indoor assembly any type made out of brass with inlet and out let and fixing plate complete including Gasket and nut blots as required at site for 25 Ltr capacity Geyser, any make complete all as directed. BI01010001010000000000000515BI0100001157 25 Each
46 46 Supply and replacement of indoor assembly any type made out of brass with inlet and out let and fixing plate complete including Gasket and nut blots as required at site for 35/50 Ltr capacity Geyser, any make complete all as directed. BI01010001010000000000000515BI0100001158 25 Each
47 47 Refixing of storage water heater(geyser) 25 /35 /50 Ltr capacity, shifted from work shop / MES Store, connecting up electrical and water connections including provision of 3 core 7/20 copper cable and testing as specified and as directed. BI01010001010000000000000515BI0100001159 90 Each
48 48 Supply and replacement of PVC connecton 45 cm long both end brass nut suitable for hot / cold water supply and screw down 15mm GI pipe. BI01010001010000000000000515BI0100001160 200 Each
49 49 M&L for grouting 4 Nos of M12 X100mm mild steel bolt in stone /brick masonary wall and making good the surface to match with the existing surface in cement mortar 1:4 suitable for hanging geysers complete all as directed. BI01010001010000000000000515BI0100001161 50 Each Job
50 50 Over hauling & servicing the solar water heater 100/200 ltr capacity by repair / replacing the spares and blocks in the solar cells removed by the acid cleaning and damaged solar cells to be replaced as directed.\nNote: Supply and replacement of spares will be measured and paid separately. BI01010001010000000000000515BI0100001162 50 Each
51 51 Supply and replacement of Anode for solar water heater 100/200 Ltr capacity BI01010001010000000000000515BI0100001163 60 Each
52 52 Supply and replacement of solar gasket as per exisiting type. BI01010001010000000000000515BI0100001164 60 Each
53 53 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 32mm (outer dia) pipe and taking down existing u/s pipes as directed. BI01010001010000000000000515BI0100001165 100 RM
54 54 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 25mm (outer dia) pipe and taking down existing u/s pipes as directed.B65 BI01010001010000000000000515BI0100001166 100 RM
55 55 Supply and fixing in repairs Bib taps suitable for bore dia of pipe 15 mm, fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule . BI01010001010000000000000515BI0100001167 60 Each
56 56 S&F in repairs Stop valves, 15 mm Bore dia of pipe, fancy type, chromium plated cast copper alloy, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. BI01010001010000000000000515BI0100001168 60 Each
57 57 Supply and replacement of MCB SPN 32/40 amps 240 V 10 KA BI01010001010000000000000515BI0100001169 40 Each
58 58 Supply and replacement of industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB SP 20 Amp complete. BI01010001010000000000000515BI0100001170 20 Each
59 59 Disconnection and removing the unserviceable heat exchanger along with its connected items and provision of new solar water heater collector (heat exchanger) for 100 ltrs solar water heater of same size and capacity complete connecting up of connections complete all as specified and as directed. \n BI01010001010000000000000515BI0100001171 7 Each
60 60 Disconnection and removing the unserviceable heat exchanger along with its connected items and provision of new solar water heater collector (heat exchanger) for 200 ltrs solar water heater of same size and capacity complete connecting up of connections complete all as specified and as directed. BI01010001010000000000000515BI0100001172 5 Each
61 61 Mild steel frame work for staging / frame work for Solar water tanks using standard sections like angle iron / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A / MS tube including necessary welding suitable to keep 300 ltrs PVC water tank complete including dismantling existing stage all as specified and directed. BI01010001010000000000000515BI0100001173 80 Kg
62 62 Supply and fixing solar water tank of stainless steel alongwith puff insulation of capacity 100 Ltrs with electrical heating backup of 2 KW including taking down existing all as specified and as directed.\n BI01010001010000000000000515BI0100001174 8 Each
63 63 Supply and fixing solar water tank of stainless steel alongwith puff insulation of capacity 200 Ltrs with electrical heating backup of 2 KW including taking down existing all as specified and as directed.\n BI01010001010000000000000515BI0100001175 3 Each
64 64 Point wiring for 15 Amps S/S combination complete with 2 runs of 2.5 sqmm , PVC insulated, unsheathed FRLS cable 1100 volts grade, multi stranded copper conductor drawn in existing PVC conduit on surface/ in wall/ roof etc. and including provision of one run of PVC insulated 2.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6mm thick MS sheet concealed in wall and laminated sheet cover of 3mm thick on top for housing the switch socket complete and taking down existing point wiring except PVC conduit all as specified and directed. BI01010001010000000000000515BI0100001176 150 Point
65 65 Sub main wiring with 2 runs of 4sqmm PVC insulated, unsheathed FRLS cable,1100 volts grade, multi stranded copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/wall/ roof etc. with one run of PVC insulated, 4 sqmm FRLS cable, copper conductor for earth continuity conductor and removing existing u/s sub main wiring complete all as specified and as directed.\n BI01010001010000000000000515BI0100001177 250 RM
66 66 Sub main wiring with 2 runs of 2.5sqmm PVC insulated, unsheathed FRLS cable,1100 volts grade, multi stranded copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface/wall/ roof etc. with one run of PVC insulated, 2.5sqmm FRLS cable, copper conductor for earth continuity conductor and removing existing u/s sub main wiring complete all as specified and as directed.\n BI01010001010000000000000515BI0100001178 320 RM
67 67 Supply and replacement of switch socket combination flush type universal 2 in 1, 3 pin 15 Amps 230 volts ISI Marked.\n BI01010001010000000000000515BI0100001179 150 Each
68 68 Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25m below normal ground level with the top edge of the earth plate not less than 1.5m (B.G.L.) and connected to galvanized iron wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made out of 8 mm dia round bar, necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. BI01010001010000000000000515BI0100001180 35 EACH SET
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail