Repair And Replacement Of Pump Motor And Other Allied Works At Raiwala Under Age ( I ) Raiwala
BOQ
| Name of Work: Repair and replacement of Pump, Motor and other allied works at Raiwala under AGE(I) Raiwala | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Opening of centrifugal pump set from the base, transporting to work shop, trace out defects and taking out the u/s parts from the pump set, metling ,grinding, lathing work as required to make as per original shape and size and fixing the new parts as required including panting complete all specified and directed by Engr-in-charge. \nNote : Spares will be measured and paid separately | |||
| 2 | 1.1 | (a) 100 HP | 3 | Each Job | |
| 3 | 1.2 | (b) 60 HP | 2 | Each Job | |
| 4 | 1.3 | (c) 3/5 HP | 2 | Each Job | |
| 5 | 2 | S&F CI impeller as per existing size and sample, Ist and IInd stages suitable for centrifugal pump set of the following capacity :- | |||
| 6 | 2.1 | (a) 100 HP cap | 6 | Each Job | |
| 7 | 2.2 | (b) 60 HP cap | 4 | Each Job | |
| 8 | 3 | S&R of CI balance wheel disk as per existing size of centrifugal pump set of the following capacity :- | |||
| 9 | 3.1 | (a) 100 HP cap | 1 | Each Job | |
| 10 | 3.2 | (b) 60 HP cap | 1 | Each Job | |
| 11 | 4 | S&R of MS stud with nut complete as per existing sample and size of centrifugal pump set of the following capacity :- | |||
| 12 | 4.1 | (a) 100 HP cap | 24 | Each | |
| 13 | 4.2 | (b) 60 HP cap | 12 | Each | |
| 14 | 5 | S&R of CI cooling ring complete as per existing sample and size of centrifugal pump set of the following capacity :- | |||
| 15 | 5.1 | (a) 100 HP cap | 2 | Each Job | |
| 16 | 5.2 | (b) 60 HP cap | 1 | Each Job | |
| 17 | 6 | S&R of CI sleeve DE/NDE complete as per existing sample and size of centrifugal pump set of the following capacity :- | |||
| 18 | 6.1 | (a) 100 HP cap | 4 | Each Job | |
| 19 | 6.2 | (b) 60 HP cap | 2 | Each Job | |
| 20 | 7 | S&R of CI neck ring complete as per existing sample and size of centrifugal pump set of the following capacity:- | |||
| 21 | 7.1 | (a) 100 HP cap | 4 | Each Job | |
| 22 | 7.2 | (b) 60 HP cap | 4 | Each Job | |
| 23 | 8 | S&R of CI/MS gland packing plate complete as per existing sample and size of centrifugal pump set of the following capacity | |||
| 24 | 8.1 | (a) 100 HP cap | 2 | Each Job | |
| 25 | 8.2 | (b) 60 HP cap | 2 | Each Job | |
| 26 | 8.3 | (c) 3/5 HP cap | 2 | Each Job | |
| 27 | 9 | S&R of CI bush(stuffing bore bush) complete as per existing sample and size of centrifugal pump set of the following capacity:- | |||
| 28 | 9.1 | (a) 100 HP cap | 4 | Each Job | |
| 29 | 9.2 | (b) 60 HP cap | 4 | Each Job | |
| 30 | 10 | S&R of CI pump shaft EN-8 (SS) complete incl key and key groove as per existing sample and size of centrifugal pump set of the following capacity:- | |||
| 31 | 10.1 | (a) 100 HP cap | 2 | Each Job | |
| 32 | 10.2 | (b) 60 HP cap | 1 | Each Job | |
| 33 | 11 | S&R of 'O' ring complete as per existing sample and size of centrifugal pump set of the following capacity:- | |||
| 34 | 11.1 | (a) 100 HP cap | 2 | Each Job | |
| 35 | 11.2 | (b) 60 HP cap | 1 | Each Job | |
| 36 | 12 | S&R of bearing catridge cover DE & NDE complete as per existing sample and size of centrifugal pump set of the following capacity:- | |||
| 37 | 12.1 | (a) 100 HP cap (Bearing No. 3309) | 3 | Each Job | |
| 38 | 12.2 | (b) 60 HP cap (Bearing No. 3307) | 2 | Each Job | |
| 39 | 12.3 | (c) 3/5 HP cap | 2 | Each Job | |
| 40 | 13 | S&R of bearing cap complete as per existing sample and size of centrifugal pump set of the following capacity:- | |||
| 41 | 13.1 | (a) 100 HP cap (Bearing No. 6309) | 3 | Each Job | |
| 42 | 13.2 | (b) 60 HP cap (Bearing No. 6307) | 2 | Each Job | |
| 43 | 14 | S&R of inter stage CI ring complete as per existing sample and size of centrifugal pump set of the following capacity | |||
| 44 | 14.1 | (a) 100 HP cap | 3 | Each Job | |
| 45 | 14.2 | (b) 60 HP cap | 2 | Each Job | |
| 46 | 15 | S&R of CI/MS coupling complete as per existing sample and size of centrifugal pump set of the following capacity:- | |||
| 47 | 15.1 | (a) 100 HP cap (Bearing No. 3309) | 2 | Each Job | |
| 48 | 15.2 | (b) 60 HP cap (Bearing No. 3307) | 2 | Each Job | |
| 49 | 15.3 | (c) 3/5 HP cap | 2 | Each Job | |
| 50 | 16 | Supply only rubber bush incl nut, bolts and washers for kirloskar make pump set complete as per existing sample and size of cenrifugal pump 100HP cap. | 10 | Each Job | |
| 51 | 17 | Supply only tyre coupling complete as per existing sample and size of centrifugal pump as following cap | |||
| 52 | 17.1 | (a) 100 HP cap | 3 | Each Job | |
| 53 | 17.2 | (b) 60 HP cap | 2 | Each Job | |
| 54 | 18 | Supply & fix leather buffallow, pressed suitable for foot valve. | 30 | Kgs | |
| 55 | 19 | Supply in replacement of ball bearing No.6306/6309/6212. | 4 | Each Job | |
| 56 | 20 | All as per item No 23 above but bearing No. 3207/6404/6308 | 4 | Each Job | |
| 57 | 21 | Supply in replacement of ball bearing No.N-321 / 3309 | 2 | Each Job | |
| 58 | 22 | All as per item No 25 above but bearing No. 29324/3307 ( for 60 HP pump set) | 2 | Each Job | |
| 59 | 23 | All as per item No 25 above but bearing No 6311/6312. | 2 | Each Job | |
| 60 | 24 | Taking out the defective parts of induction motor, 3 phase, 440 Volts and rewinding with super enamelled copper conductor of suitable as per existing size and gauge including varnishing, drying, cleaning of slots, repair to any damage slot, metling to shaft for fixing of bearing and other required work for smooth functioning of motor, testing and painting complete all as directed and specified of the following capacity of motors:- | |||
| 61 | 24.1 | (a) 100 HP cap | 4 | Each Job | |
| 62 | 24.2 | (b) 60 HP cap | 2 | Each Job | |
| 63 | 24.3 | (b) 3/5 HP cap | 2 | Each Job | |
| 64 | 25 | M&L for replacement of greased graphite gland packing of following sizes Make - Champion or eqt | |||
| 65 | 25.1 | (a) 10 mm size | 15 | Kgs | |
| 66 | 25.2 | (b) 12 mm size | 15 | Kgs | |
| 67 | 26 | M&L for replacement of grease type AP3 complete all as specified and directed by Engineer - in - Charge | 20 | Kgs | |
| 68 | 27 | M&L for replacement of pressure gauge 0-100 PSI, dial type fixed on pumping line in various pumps all as specified. | 2 | Each Job | |
| 69 | 28 | M&L for replacement of exisiting air release valve made out of brass suitable for pumpset of various capacities all as specification & directed. | 10 | Each Job | |
| 70 | 29 | Repair to foot valve of 150 mm dia suction line by means disconnection by opening of nut bolts etc and taking out from under ground Sump and refixing the same after replacement of leather/Neoprane/rubber sheet including lightening of nut bolts etc. | 2 | Each Job | |
| 71 | 30 | M&L for replacement of hello light packing 1 mm to 2 mm thick in above centrifugal pumping set at the time of assembling / refixing complete all as specified and directed by Engineer - in - Charge. | 40 | Kg | |
| 72 | 31 | S&F in replacement of single phase preventer, three phase, 415 volts, AC 50 Hz complete all as specified and directed | 4 | Each | |
| 73 | 32 | S&F in replacement of Ampere meter 4 sequare range 0 to 200 Amp with CT complete all as specified and directed | 4 | Each Job | |
| 74 | 33 | S&F in replacement of voltmeter 4 square range 0 to 400 Volts complete all as specified and directed | 4 | Each Job | |
| 75 | 34 | Repair & overhauling of fully autimatic ATS starter of 60 HP of capacity 3 phase 415 volts including rewinding with super enameled copper wire of proper guage, varnishing, tapping, insulation glass sleeves etc all as specified and directed by Engineer - in - Charge.Note : Spares will be measured and paid separately | 1 | Each Job | |
| 76 | 35 | Supply and repair fully automatic starter of 60 HP with replacement of following items complete all as spcified and directed. | |||
| 77 | 35.1 | (a) Fixed power copper contacts suitable 60 HP star delta starter (Set of 9) | 1 | Each | |
| 78 | 35.2 | (b) Moving power contacts suitable for 60 HP star delta starter (Set of 9) | 1 | Each | |
| 79 | 35.3 | (c) Overload relay suitable for 60 HP | 1 | Each | |
| 80 | 35.4 | (d) Timer switch for 60 HP | 1 | Each | |
| 81 | 35.5 | (e) No volt coil for 60 HP | 1 | Each | |
| 82 | 36 | Repair & overhauling of fully autimatic ATS starter of 100 HP of capacity 3 phase 415 volts including rewinding with super enameled copper wire of peoper guage, varnishing, tapping, insulation glass sleeves etc all as specified and directed by Engineer - in - Charge. Note : Spares will be measured and paid separately | 5 | Each Job | |
| 83 | 37 | Supply and repair fully automatic starter of 100 HP with replacement of following items complete all as specified and directed. | |||
| 84 | 37.1 | (a) Fixed power copper contacts suitable 100 HP star delta starter (Set of 9) | 5 | Each | |
| 85 | 37.2 | (b) Moving power contacts suitable for 100 HP star delta starter (Set of 9) | 5 | Each | |
| 86 | 37.3 | (c) Overload relay suitable for 100 HP | 5 | Each | |
| 87 | 37.4 | (d) Timer switch for 100 HP | 5 | Each | |
| 88 | 37.5 | (e) No volt coil for 100 HP | 4 | Each | |
| 89 | 38 | S&F MCCB 4 pole 415 volts, Adjustable type, under protection range 400 Amps, 415 volts of rupturing capacity 50 KA | 2 | Each | |
| 90 | 39 | S&F MCCB 3 pole 415 volts, Adjustable type, under protection range 250 Amps, 415 volts of rupturing capacity 36 KA | 2 | Each | |
| 91 | 40 | Supply and top up/replacement electric motor starter oil | 100 | Ltrs | |
| 92 | 41 | Supply and fixing in replacement of submersible flat copper cable multistranded 3 core of size 50 sqmm with voltage grade 1100 V complete including connecting and testing complete all as directed by Engr-in-charge. | 55 | RM | |
| 93 | 42 | Supply & Fix in replacement fully automatic Star Delta Starter maximum motor output at 415 volt 3 phase suitable for upto 150 HP pump set, maximum relay range 90 to 150 Amps. Make : L&T,Havells or C&S | 1 | Each |
AI Tender Summary
Tender Timeline
Jul 30, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 21, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender