Special Repair And Replacement Of Dg Set Pumping Set And Summer Appliances Against Ber Items At Tech Area Taku Cpe Itarsi Under Ge ( I ) ( P ) Fy Jabalpur, Itarsi-Madhya Pradesh

Military Engineer Services-MES has published Special Repair And Replacement Of Dg Set Pumping Set And Summer Appliances Against Ber Items At Tech Area Taku Cpe Itarsi Under Ge ( I ) ( P ) Fy Jabalpur. Submission Date for this Tender is 31-08-2020. Diesel Generators Tenders in Itarsi Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25033795
Corrigendum : Special Repair And Replacement Of Dg Set Pumping Set And Summer Appliances Against Ber Items At Tech Area Taku Cpe Itarsi Under Ge ( I ) ( P ) Fy Jabalpur
Open Tender
Indian
Madhya Pradesh
Itarsi
31-08-2020

Tender Details

Special Repair And Replacement Of Diesel Generator Set Pumping Set And Summer Appliances Against Ber Items At Tech Area Taku Cpe Itarsi Under Ge ( I ) ( P ) Fy Jabalpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Aug-2020 Corrigendum1 Date 24-08-2020
2 13-Aug-2020 Corrigendum2 BOQ 24-08-2020
3 17-Aug-2020 Corrigendum3 Date 31-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
INR 36 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR AND REPLACEMENT OF DG SET, PUMPING SET AND SUMMER APPLIANCES AGAINST BER ITEMS AT TECH AREA TAKU, CPE, ITARSI UNDER GE (I) (P) FY JABALPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, installation, commisioning and testing of Diesel Engine driven generating set 62.5 KVA, 50 KW, 415 Volts, 3 phase 4 wire, engine complete with integral acoustic enclosures as per latest Indian Standards of central pollution control board and as alternator with relay panel for automatic starting on mains failure, control panel, sound proof canopy with AMF pannel and PCC foundation of required size for DG set as per manufacturer's instructions with GI tin shed for protection of panel and DG set from rain water complete including the following :- 1 Each
2 1.01 A. ENGINE :-
3 1.02 (i) 4 cylinder, In-line 4 stroke, radiator cooled engine.
4 1.03 (II) Optimised turbocharger for increased altitude capabilities fuel economy with In line fuel pump with electric governer.
5 1.04 (iii) Stainless steel exhaust flexible coupling and exhaust pipe
6 1.05 (iv) Radiator
7 1.06 (v) Coolant inhabitor
8 1.07 (vi) Plate type lubricant oil cooler
9 1.08 (vii) Spin-on fileters coolant, fuel & lubricant oil.
10 1.09 (viii) Dry type heavy duty replaceable paper element air cleaner with restriction indicator.
11 1.1 (ix) Fly wheel housing and fly wheel suit single bearing alternator.
12 1.11 (x) Electrical starter motor
13 1.12 (xi) Battery charging alternator.
14 1.13 (xii) 12 volts 9.0 AH ESE battery with multi standared copper cable for connecting wire and terminal complete
15 1.14 (xiii) First fill lub oil.
16 1.15 B. ALTERNATOR :-
17 1.16 (i) Self exited, self repulated.
18 1.17 (ii) Voltage regulation plus/minus/percent.
19 1.18 (iii) Class 'H' insulation
20 1.19 (iv) Silent pole revolving field.
21 1.2 (v) Digital automatic voltage regulator.
22 1.21 (vi) Notice level 75 dBA@ /meter
23 1.22 (vii) Telephone interference factor .50
24 1.23 (viii) Total harmonic factor better than 2%
25 1.24 (ix) Supplying power to variable electrical load for unlimited hours. Prime power (PRP) is in accordance with ISO 8523. 10% overload capacity for 1 hours every 12 hours of operation and will be suitable tropical conditions.
26 1.25 C. FUEL TANK :-
27 1.26 (i) Fuel tank suitable capacity for 12 Hrs on full load with provision for supply and return lines, level indicator, drain valve, cleaning cover, vent pipe & locking devices shall be provided.
28 1.27 (ii) Fuel pipe line from fuel tank to FIP of suitable size.
29 1.28 (iii) The fuel tank has to be mounted / located in side the cubicle.
30 1.29 D. ACOUSTIC ENCLOSURE :-
31 1.3 (i) Designed to meet stringent MoEF/CPCB-II norms 75 dBA @ 1 meter.
32 1.31 (ii) Air inlet louvers to be designed to operate at rated load even at 50 degree centigrade air inlet temp. Four point lifting for easy handling.
33 1.32 (iii) Cubical to be powder coated for long lasting service life and super finish with UV resistent poder coating, it has to with stand extreme environment. Has to be use stain steel hardware.
34 1.33 (iv) Insulation material conforming to IS 8183 speces for better sound.
35 1.34 (v) Genset control unit with integrated E-governor helps in reading all genset inputs and controls the genset GCU help in monitoring of following parameters, Controls the engine speed, supports auto mains failure (AMF) functions for 3 ph genset, low fuel level, support manual control (MCP) functions for 3 phase genset, Measres Genset, Measures Genset Voltages and currents, Measures electrical parameters like frequency, Power factor, Generato, KVA, KW, KVAr, Monitor critical engine safety parameters, Starts/Stops the genset, Have counters for genset start/stop, run hours, KWH, power factor
36 1.35 E. INBUILT AMF CONTROL PANEL FOR DG SET :-
37 1.36 (I) MCB 63 Amps, 4 pole, 415 volts, 10 KA, 50 Hz - 02 Nos
38 1.37 (ii) Power contactors of suitable sizes, Air break type - 02 Nos
39 1.38 (iii) Digital type multi functional meter -01 Nos, Glass Relay (DVR), Glass Relay, , Relay base, start/stop, relay board, MCB SP, selector, integral LED pilot, togle switch and other equipment as required for smooth functioning of genset
40 1.39 (iv) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos
41 1.4 (v) Micro processor based relay of suitable size/ratings-01 Nos
42 1.41 (vi) Battery charger auto/manual switch - 01 Nos
43 1.42 (vii) Suitable communication with features of following protections :- Over current, overvoltage, under voltage, under frequency, Low pressure oil.
44 1.43 (viii) Genset shall be fully automatic ie auto on when mains fail and auto off when mains on complete
45 1.44 F. MAINTENANCE AND OPERATIONAL MANUAL OF PLANTS - 01 SET SHALL BE SUBMITTED BY CONTRACTOR ALONGWITH THE FOLLOWING :-
46 1.45 (I) Test certificate of Alternator.
47 1.46 (ii) Test certificate of Diesel Engine.
48 1.47 (iii) Test certificate of Gen Set (by OEM).
49 1.48 (iv) Test certificate of Acoustic enclouser.
50 1.49 (v) Rubber mat.
51 1.5 Note : (a) Provision of PCC plateform as per manufacturer guidelines/specifications and shall be of required size. The cost of the same shall be deemed to be included in the unit quoted rates. Nothing shall be admissible on this account
52 1.51 (b) Testing of the DG set shall be carried out by the rep of the accepting office/IEM
53 1.52 (c ) The contractor shall submit the drawing for approval of the GE before procurement of the DG set
54 1.53 (d) Resistive load whether water load or strip heaters of suitable capacity and POL/DHPP for testing of DG set to be made available during test by the contractor. The cost of the same shall be deemed to be included in the unit quoted rates.
55 1.54 (e) The DG set shall be procured from authorized OEM and of same group. The accoustic panel shall also be manufactured by the same OEM
56 1.55 (f) Anyother details not mentioned above but is required for efficient functioning of DG set is deemed to be included in the unit quoted rate
57 2 Supply, installation, commisioning and testing of Diesel Engine driven generating set 30 KVA, 50 KW, 415 Volts, 3 phase 4 wire, engine complete with integral acoustic enclosures as per latest Indian Standards of central pollution control board and as alternator with relay panel for automatic starting on mains failure, control panel, sound proof canopy with AMF pannel and PCC foundation of required size for DG set as per manufacturer's instructions with GI tin shed for protection of panel and DG set from rain water complete including the following :- 1 Each
58 2.01 A. ENGINE :-
59 2.02 (i) 4 cylinder, In-line 4 stroke, radiator cooled engine.
60 2.03 (II) Optimised turbocharger for increased altitude capabilities fuel economy with In line fuel pump with electric governer.
61 2.04 (iii) Stainless steel exhaust flexible coupling and exhaust pipe
62 2.05 (iv) Radiator
63 2.06 (v) Coolant inhabitor
64 2.07 (vi) Plate type lubricant oil cooler
65 2.08 (vii) Spin-on fileters coolant, fuel & lubricant oil.
66 2.09 (viii) Dry type heavy duty replaceable paper element air cleaner with restriction indicator.
67 2.1 (ix) Fly wheel housing and fly wheel suit single bearing alternator.
68 2.11 (x) Electrical starter motor
69 2.12 (xi) Battery charging alternator.
70 2.13 (xii) 12 volts 9.0 AH ESE battery with multi standared copper cable for connecting wire and terminal complete
71 2.14 (xiii) First fill lub oil.
72 2.15 B. ALTERNATOR :-
73 2.16 (i) Self exited, self repulated.
74 2.17 (ii) Voltage regulation plus/minus/percent.
75 2.18 (iii) Class 'H' insulation
76 2.19 (iv) Silent pole revolving field.
77 2.2 (v) Digital automatic voltage regulator.
78 2.21 (vi) Notice level 75 dBA@ /meter
79 2.22 (vii) Telephone interference factor .50
80 2.23 (viii) Total harmonic factor better than 2%
81 2.24 (ix) Supplying power to variable electrical load for unlimited hours. Prime power (PRP) is in accordance with ISO 8523. 10% overload capacity for 1 hours every 12 hours of operation and will be suitable tropical conditions.
82 2.25 C. FUEL TANK :-
83 2.26 (i) Fuel tank suitable capacity for 12 Hrs on full load with provision for supply and return lines, level indicator, drain valve, cleaning cover, vent pipe & locking devices shall be provided.
84 2.27 (ii) Fuel pipe line from fuel tank to FIP of suitable size.
85 2.28 (iii) The fuel tank has to be mounted / located in side the cubicle.
86 2.29 D. ACOUSTIC ENCLOSURE :-
87 2.3 (i) Designed to meet stringent MoEF/CPCB-II norms 75 dBA @ 1 meter.
88 2.31 (ii) Air inlet louvers to be designed to operate at rated load even at 50 degree centigrade air inlet temp. Four point lifting for easy handling.
89 2.32 (iii) Cubical to be powder coated for long lasting service life and super finish with UV resistent poder coating, it has to with stand extreme environment. Has to be use stain steel hardware.
90 2.33 (iv) Insulation material conforming to IS 8183 speces for better sound.
91 2.34 (v) Genset control unit with integrated E-governor helps in reading all genset inputs and controls the genset GCU help in monitoring of following parameters, Controls the engine speed, supports auto mains failure (AMF) functions for 3 ph genset, low fuel level, support manual control (MCP) functions for 3 phase genset, Measres Genset, Measures Genset Voltages and currents, Measures electrical parameters like frequency, Power factor, Generato, KVA, KW, KVAr, Monitor critical engine safety parameters, Starts/Stops the genset, Have counters for genset start/stop, run hours, KWH, power factor
92 2.35 E. INBUILT AMF CONTROL PANEL FOR DG SET :-
93 2.36 (I) MCB 63 Amps, 4 pole, 415 volts, 10 KA, 50 Hz - 02 Nos
94 2.37 (ii) Power contactors of suitable sizes, Air break type - 02 Nos
95 2.38 (iii) Digital type multi functional meter -01 Nos, Glass Relay (DVR), Glass Relay, , Relay base, start/stop, relay board, MCB SP, selector, integral LED pilot, togle switch and other equipment as required for smooth functioning of genset
96 2.39 (iv) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos
97 2.4 (v) Micro processor based relay of suitable size/ratings-01 Nos
98 2.41 (vi) Battery charger auto/manual switch - 01 Nos
99 2.42 (vii) Suitable communication with features of following protections :- Over current, overvoltage, under voltage, under frequency, Low pressure oil.
100 2.43 (viii) Genset shall be fully automatic ie auto on when mains fail and auto off when mains on complete
101 2.44 F. MAINTENANCE AND OPERATIONAL MANUAL OF PLANTS - 01 SET SHALL BE SUBMITTED BY CONTRACTOR ALONGWITH THE FOLLOWING :-
102 2.45 (I) Test certificate of Alternator.
103 2.46 (ii) Test certificate of Diesel Engine.
104 2.47 (iii) Test certificate of Gen Set (by OEM).
105 2.48 (iv) Test certificate of Acoustic enclouser.
106 2.49 (v) Rubber mat.
107 2.5 Note : (a) Provision of PCC plateform as per manufacturer guidelines/specifications and shall be of required size. The cost of the same shall be deemed to be included in the unit quoted rates. Nothing shall be admissible on this account
108 2.51 (b) Testing of the DG set shall be carried out by the rep of the accepting office/IEM
109 2.52 (c ) The contractor shall submit the drawing for approval of the GE before procurement of the DG set
110 2.53 (d) Resistive load whether water load or strip heaters of suitable capacity and POL/DHPP for testing of DG set to be made available during test by the contractor. The cost of the same shall be deemed to be included in the unit quoted rates.
111 2.54 (e) The DG set shall be procured from authorized OEM and of same group. The accoustic panel shall also be manufactured by the same OEM
112 2.55 (f) Anyother details not mentioned above but is required for efficient functioning of DG set is deemed to be included in the unit quoted rate
113 3 Supply and install water cooler stainless steel electric driven (single phase) having approx storage capacity of 80 Litres and nominal cooling capacity of 40 Litres per hours with minimum 3 star rating. Make- LG/Samsung/Blue Star / Voltas / Usha Sriram 10 Each
114 4 Supply and installed of refrigerator electric driven (single phase) capacity 310 Ltrs complete with minimum 3 star rating all as specified and directed. Make- LG/Samsung/ Godrej / Whirpool 2 Each
115 5 Supply and installed hi wall split units indoor / outdoor complete with cordless remote controll unit and and inbuilt air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR with necessary wall brackets complete all as specified and directed.Make- LG/Samsung / Daikin/ Godrej/ Voltas/ Blue Star/ Carrier 6 Each
116 6 Supply , install, testing and commissioning factory made cubical type, CPRI approved outdoor type LT panel board totally enclosed, weather and vermin proofIP 55 class protection, 1100 volts grade, 50 Hz AC Supply made out of 3.00 mm thick CRCA sheet steel for load bearing and 2mm thick for non-laod bearing conforming to IS 2417--1962 insulated Aluminium busbar of 200 Amps ratings installed on fiber insulators housed in seperate bus chambers covered with heat shrinkable sleeve with necessary bus bar taping, copper controlled wiring of required size with 40x40x6mm angle iron frame , hinged doors, gront and locking arrangement and powder coated on out side and inside including provision of PCC platform 100mm thick with PCC 1:4:8, type D2 and bric work etc using 40mm graded stone aggregate one meter arround the panel board,cable gland and lugs for incomming and out going cable etc. and to be accomodated with following accessories, delta starter single phase priventer relays etc of 15 HP pumps. 2 Each Job
117 6.01 (a) 4 Nos bus bar rating 200 Amps and fixed on heavy duty rubberised / porcelain support - 01 No
118 6.02 (b) MCCB 125 Amps 4 Pole 30 KA - 01 Nos
119 6.03 (c) MCCB 63 Amp,4 pole, 415 Volts, 18KA - 04 Nos
120 6.04 (d) On load change over switch with Enclosure of capacity 125Amp, 415 volts , 4 pole - 01 No
121 6.05 (e) Meter combination to rated voltage 0-500 volts and currents 0-125 Amps in three phase system Digital type - 01 Nos
122 6.06 (f) Capacitor bank 3 phase 415 Volts, 50 hz AC 5 KVAR - 01 No
123 6.07 (g) Indication lamp for RYB - 1 set
124 6.08 (h) Terminal block 125 Amps for incoming supply for RYBN - 01 No
125 6.09 (j) Terminal black 63Amps to out going supply for RYB - 05 No
126 7 Material and labour for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal top edge of the plate not less than 1.5 mtr below normal ground level connected with GI earth strip of size 32 x 6 mm thick at two points by means of bolts and nuts, check nuts and washers including charcoal dust, common salt, necessary exacavation in soft / loose soil, returning filling in and removal of surplus soil to a distance up to 50m, PCC pit in 1:3:6 type CI, using 20mm grade stone aggregate and MS angle iron frame 40 x 40 x 6mm, RCC 1:2:4 type B-1 using 20mm grade stone aggregate, 40mm thick pit cover, reinforced with 6mm dia TMT bars 75mm centre to centre both ways, MS handle 12mm dia, PGI funnel, wire mesh and GI pipe of 20mm bore (light grade) and earth lead protection pipe 40mm bore (medium grade) 5m long as shown in electrical plate No.5 of SSR Part-I including testing complete all as per directed. 4 Set of Two Nos
127 8 Supply , installed test and comissioning of multistage submersible pump,electric 3 phase complete of pumping 330LPM at 120 meter head including connecting the same to colomn pipe of 50mm dia and lowering the same into borewell alongwith necessary submersible cable complete all as directed. 3 Each
128 8.01 Note : (i) Lowering pipe and cable will be measured and paid saperately.
129 8.02 (ii). The capacity of pump set mentioned in tentetive and there is a posibilities to change the capacity and specificaion of pump set depending on the yield of the bore well . Tenderer will take procurement action for action for pump based on yield test results.
130 8.03 (iii) Preor approval of the accepting officerwill be obtained if there is any change in specification of pump set.
131 8.04 (iv) Discharge of pump will be decided according to yield of bore well by accepting officer.
132 9 Supply and fix PVC insulated and PVC sheathed multi stranded copper conductor flat weather proof cable for submersible pump set of size 3 core 6 Sqmm 1100 volts grade including necessary water Proof connection to submersible pump of cable lead complete all as specified and directed. 120 RM
133 10 Material and labour for GI colomn pipes for submersible pump , 3 meter standered length as per IS heavy duty grade 50mm box ISI marked with long GI socket complete. for holding and fasting the colomn pipe including jointing complete all as specified and directed. 120 RM
134 11 Supply and fix in reapir of star delta starter suitable for submersible pump of over load current rating 17-25 amps with phase falilure, phase imbalance, phase reversal short circuit protection including voltmeter, ammeter with ON- OFF trip indication and dry run preventor complete all as directed. 3 Each
135 12 Supply and fixing of Centrifugal pump set, electric driven 415 V, 3 phase system having capacity 45 HP having head of 30m and discharge of 550 LPM inclusive of starter and PCC poundation 1:4:8, type D2 using 40mm stone aggregate as per and all as per specified and directed by Engr-in-charge. 1 Each
136 13 Supply and fixing of monoblock pump set, electric driven 415 V, 3 phase system having capacity 15 HP having head of 60m and discharge of 225 LPM inclusive of starter and PCC poundation 1:4:8, type D2 using 40mm stone aggregate as per and all as per specified and directed by Engr-in-charge. 3 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail