}

Provision Of Special Repair/Conversion Of Ht Oh Line To Aerial Bunched Cables And Capacitor Bank Panels Under Ge Satwari, GE SATWARI-Jammu And Kashmir

Military Engineer Services-MES has published Provision Of Special Repair/Conversion Of Ht Oh Line To Aerial Bunched Cables And Capacitor Bank Panels Under Ge Satwari. Submission Date for this Tender is 04-08-2020. Overhead Line Tenders in GE SATWARI Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

25024921
Provision Of Special Repair/Conversion Of Ht Oh Line To Aerial Bunched Cables And Capacitor Bank Panels Under Ge Satwari
Open Tender
Indian
Jammu And Kashmir
GE SATWARI
04-08-2020

Tender Details

Provision Of Special Repair / Conversion Of Ht Oh Line To Aerial Bunched Cables And Capacitor Bank Panels Under Ge Satwari

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 43 Lakhs /-

BOQ Items

Tender Inviting Authority: GE Satwari Name of Work : PROVN OF SPL REPAIR/CONVERSION OF HT OH LINE TO AERIAL BUNCHED CABLES AND CAPACITOR BANK PANELS UNDER GE SATWARI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches for foundation of poles, laying of cables n.exc 1.5m in width and n.exc 1.5m in depth and getting out in any type of soil, complete all as specified 151 Cum
2 2 All as per item No 01 above but exceeding 1.5 mtr and not exceeding 3 mtr depth..complete all as sepecified dirceted by engr-in-charge. 12 Cum
3 3 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, all as specified . 87 Cum
4 4 Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed. 76 Cum
5 5 Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trench 32 Cum
6 6 Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sub class 'B' bricks. 3200 Each
7 7 M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc complete all as specified and directed 20.6 Cum
8 8 M&L for Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping of poles etc including necessary form work complete all as specified. 1 Cum
9 9 M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) in stay assy, filling and mass concrete all as specified. 6.68 Cum
10 10 Dismantling of aluminium conductor steel reinforced (ACSR) of any size etc complete all as specified. 7.5 Qtl
11 11 Dismantling of unserviceable GI wire of any size all as directed by Engg-in-Charge. 2.5 Qtl
12 12 Dismentling of HT insulators of any type, size and make all as directed by Engg-in-Charge. 102 Each
13 13 Supply and fix HT overhead lines on existing poles with XLPE insulated AB Cable 3 core x 95 sqmm + 1 x70 sqmm including accessories complete all as directed by Engg-in-Charge. Make : Havells/Gloster/Polycab 500 RM
14 14 Supply and fix HT overhead lines on existing poles with XLPE insulated AB Cable 3 core x 70 sqmm + 1 x50 sqmm including accessories complete all as directed by Engg-in-Charge. Make : Havells/Gloster/Polycab 220 RM
15 15 Supply and fix HT overhead lines on existing poles with XLPE insulated AB Cable 3 core x 185 sqmm + 1 x 150 sqmm including accessories, cable end kits, straight through kitscomplete all as directed by Engg-in-Charge. Make : Havells/Gloster/Polycab 563 RM
16 16 Supply and fix HT overhead lines on existing poles with XLPE insulated AB Cable 3 core x 120 sqmm + 1 x 95 sqmm including accessories, cable end kits, straight through kits complete all as directed by Engg-in-Charge. Make : Havells/Gloster/Polycab 840 RM
17 17 Supply and fix Cable end kit single core for HT AB Cable 95 sqmm complete all as directed by Engg-in-Charge. Make 3M/M Seal/Reychem 16 Each
18 18 Supply and fix Cable end kit single core for HT AB Cable 70 sqmm complete all as directed by Engg-in-Charge. Make 3M/M Seal/Reychem 10 Each
19 19 Supply and fix Cable straight through jointing kit single core for HT AB Cable 95 sqmm complete all as directed by Engg-in-Charge. Make 3M/M Seal/Reychem 6 Each
20 20 Supply and fix Cable straight through jointing kit single core for HT AB Cable 70 sqmm complete all as directed by Engg-in-Charge. Make 3M/M Seal/Reychem 6 Each
21 21 M&L For Earthing complete with galvanized steel earth plate electrode 60cmx60cmX6mm thick buried directly in ground to a depth not less than 3 mtr below normal ground level with top edge of earth plate at a depth not less than 2.40 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal and common salt and connected with and including GI wire of size 4 mm by means of bolts, nuts, check nuts and washers of GI connected to pole/ABC cable, 15mm bore of GI pipe (light grade) from earth plate up to testing point for protection of GI wire and 40 mm bore GI pipe (light grade) with wire mesh and funnel for watering including necessary excavation and earth work, (in any type of soil) PCC chamber (1:3:6) type C-2 with RCC cover with suitable size of handle made out of 8mm dia MS bars and angle iron 40x40x 3mm frame for cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part-I 2009 complete all as specified \nNote : (i) RCC pit cover shall be precast of RXX (1:2:4) type B-1, 80 mm thick, reinforcement with 8 mm tor steel in lieu of CI cover and the rate includes in the unit rate of item \n(ii) Earth electrode shall be projected upto test pit using necessary arrangement with suitable size GI pipe and the rate in the unit rate of item\n(iii) RCC cover shall be painted with red paint over a primer coat and the rate include in the unit rate of item 23 Each
22 22 Supply & Errecting truelly vertical position steel tubular swaged poles in replacement of UNSV /Broken PCC poles complete with CI base plate, finial taper plug bolts, nuts & screws 11.0 mtr long type 410 SP-55 including painting of poles with 2 coats of approved aluminium paint over a coat of red oxide, making five strips of black and white paint from PCC of size 30cm thick, numbering of pole with black or white colour by means of stencils all as specified and directed by Engg-in-Charge. 30 Each
23 23 Supply and fixing in replacement of galvanized steel stay assembly complete with stay rod 20mm dia including stay strand 7/4 mm fixed for stay of poles including necessary MS clamp of 50x6mm flat iron nuts and bolts, loop insulators complete all as specified and directed by Engr-in-Charge. Note:- Earth work, PCC shall be measured and paid separately. 20 Each
24 24 Supply and fixing Dead end clamps for LT/HT Cables 18 Each
25 25 Supply and fixing Anchoring Clamps suitable for all sizes of ABC cables 70 Each
26 26 Supply and fixing Anchoring Hooks suitable for all sizes of ABC cables 70 Each
27 27 Supply and fixing Tensioning Clamps suitable for all sizes of ABC cables 10 Each
28 28 Supply and fixing GI wire and supply and fixing GI wire 3.15mm dia for connecting earthing to ABC cable 0.5 Qtl
29 29 Supply, laying for underground 25 Sqmm x 3.5 core size LT cable 1100 Volts grade heavy duty electric cable PVC insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest ammendments of sizes:- (MAKE :Havells, KEI,POLYCAB ) Note:- Earthwork/excavation shall be measured seperately 160 RM
30 30 Description all as per srl item No 29 but 35 Sqmm x 3.5 core 100 RM
31 31 Description all as per srl item No 29 but 50 Sqmm x 3.5 core 100 RM
32 32 Description all as per srl item No 29 but 70 Sqmm x 3.5 core 100 RM
33 33 Supply , fixing , connecting and commissioning and testing of Outdoor type Company Make (automatic and manual operation) power factor improvement panel of capacity 20 Kvar factory made, weather proof , dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA Sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 75' cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size upto 30 cms including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles. Make of the panel DVEPL /POWER SYSTEM & CONTROLS JALANDHAR/ Adlec with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. Note :- Amount of PCC is deemed in the item rate and no other amount will be paid to contractor on this account 7 Each
34 34 Incoming feeder:- A. Incommer MCCB 63- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Legrand /Schneider/ L&T- 1 No B.Metering Section- Digital Ammeter (0-150)Amps, digital\nVolt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 C. Insulated Busbar of Aluminium of 100A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. D. Multi 6 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
35 35 Outgoing feeder :- E. Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicators and selector switch. Make :- Legrand /Schneider/ L&T F. Accessories for 2 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T G. Accessories for 3 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T H. Accessories for 4 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T I. Accessories for 10 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :-Legrand /Schneider/ L&T J. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads
36 36 K. 6 Stpes Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically .Make: Legrand /Schneider/ L&T L. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted.
37 37 Supply , fixing , connecting and commissioning and testing of outdoor type Company Make (automatic and manual operation) power factor improvement panel of capacity 25 Kvar factory made, weather proof , dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 75 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 30 cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , Make of the panel DVEPL /POWER SYSTEM & CONTROLS JALANDHAR/ Adlec with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. 4 Each
38 38 Incoming feeder:- A. Incommer MCCB 63- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Legrand /Schneider/ L&T- 1 No B.Metering Section- Digital Ammeter (0-150)Amps, digital\nVolt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 C. Insulated Busbar of Aluminium of 100A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. D. Multi 6 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
39 39 Outgoing feeder :- E. Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicators and selector switch. Make :-Legrand /Schneider/ L&T F. Accessories for 2 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T G. Accessories for 3 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T H. Accessories for 4 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T I. Accessories for 5 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 5 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T J. Accessories for 10 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :-Legrand /Schneider/ L&T
40 40 K. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads L. 6 Stpes Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically .Make: L&T/ Schneider / Legrand. M. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted.
41 41 Supply , fixing , connecting and commissioning and testing of outdoor type Company Make (automatic and manual operation) power factor improvement panel of capacity 75 Kvar factory made, weather proof , dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles. Make of the panel DVEPL /POWER SYSTEM & CONTROLS JALANDHAR/ Adlec with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. 1 Each
42 42 Incoming feeder:- A. Incommer MCCB 125- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Legrand/Schneider/ L&T- 1 No B.Metering Section- Digital Ammeter (0-150)Amps, digital\nVolt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 C. Insulated Busbar of Aluminium of 150A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. D. Multi 7 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
43 43 Outgoing feeder :- E. Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicators and selector switch. Make :- Legrand /Schneider/ L&T F. Accessories for 2 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T G. Accessories for 4 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T H. Accessories for 8 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 8 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T I. Accessories for 10 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T
44 44 J. Accessories for 25 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 25 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 63 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T K. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads L. 7 Stpes Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically .Make: L&T/ Schneider / Legrand. M. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted.
45 45 Supply , fixing , connecting and commissioning and testing of outdoor type Company Make (automatic and manual operation) power factor improvement panel of capacity 100 Kvar factory made, weather proof , dust and vermin proof (IP54/IP 42) suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles. Make of the panel DVEPL /POWER SYSTEM & CONTROLS JALANDHAR/ Adlec with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. 1 Each
46 46 Incoming feeder:- A. Incommer MCCB 160- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Legrand/Schneider/ L&T- 1 No B.Metering Section- Digital Ammeter (0-150)Amps, digital\nVolt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 C. Insulated Busbar of Aluminium of 200A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. D. Multi 8 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
47 47 Outgoing feeder :- E. Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicators and selector switch. Make :- Legrand /Schneider/ L&T F. Accessories for 2 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T G. Accessories for 4 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T H. Accessories for 8 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 8 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T I. Accessories for 10 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T
48 48 J. Accessories for 25 KVAR Capacitor Bank - 3 Nos :- Capacitor Duty Contactor 25 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 63 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. Make :- Legrand /Schneider/ L&T K. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads L. 8 Stpes Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically .Make: L&T/ Schneider / Legrand. M. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail