Construction Of Temp Structure Toilet Block Instead Of Construction Of Pre Fab Structure Of Size 7 . 32 Mtr X 4 . 88 Mtr With Verandah For Toilet Block At Bop Katalbasti Sanatan Of 64 Bn Bsf Under Shq Bsf Panisagar Sh Internal Electrification Of Toilet Bl, BOP SANATAN 64 BN BSF-Tripura

Border Security Force-BSF has published Construction Of Temp Structure Toilet Block Instead Of Construction Of Pre Fab Structure Of Size 7 . 32 Mtr X 4 . 88 Mtr With Verandah For Toilet Block At Bop Katalbasti Sanatan Of 64 Bn Bsf Under Shq Bsf Panisagar Sh Internal Electrification Of Toilet Bl. Submission Date for this Tender is 13-08-2020. Electrification Work Tenders in BOP SANATAN 64 BN BSF Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

25010959
Construction Of Temp Structure Toilet Block Instead Of Construction Of Pre Fab Structure Of Size 7 . 32 Mtr X 4 . 88 Mtr With Verandah For Toilet Block At Bop Katalbasti Sanatan Of 64 Bn Bsf Under Shq Bsf Panisagar Sh Internal Electrification Of Toilet Bl
Open Tender
Indian
Tripura
BOP SANATAN 64 BN BSF
13-08-2020

Tender Details

Construction Of Temp Structure Toilet Block Instead Of Construction Of Pre Fab Structure Of Size 7 . 32 Mtr X 4 . 88 Mtr With Verandah For Toilet Block At Bop Katalbasti Sanatan Of 64 Bn Bsf Under Shq Bsf Panisagar Sh Internal Electrification Of Toilet Block

Key Value

Document Fees
Refer document
EMD
INR 975.0 /-
Tender Value
INR 48738.0 /-

BOQ Items

Name of Work: C/O Temp structure toilet block instead of construction of pre fab structure of size 7.32 mtr X 4.88 mtr with Verandah for toilet block at BOP Katalbasti Sanatan of 158 BN (Now 64 Bn)BSF under SHQ BSF Panisagar.(SH:- Internal Electrification of Toilet Block)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Group A) BI01010001010000000000000515BI0100001114 9 Point
2 2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. BI01010001010000000000000515BI0100001115 10 Mtr
3 3 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. BI01010001010000000000000515BI0100001116 3 each
4 4 Supplying and fixing PVC batten/ angle holder including connections etc. as required BI01010001010000000000000515BI0100001120 6 Each
5 5 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required BI01010001010000000000000515BI0100001121
6 5.01 a) Single pole( 6 Amp) BI01010001010000000000000515BI0100001122 2 Each
7 5.02 b) Double pole -32A BI01010001010000000000000515BI0100001123 1 Each
8 6 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required BI01010001010000000000000515BI0100001124 1 Set
9 7 Supply and fixing 6 SWG GI wire on surface or in recess for loop earthing along with existing/recessed conduit / submain wiring / cable etc as required. BI01010001010000000000000515BI0100001125 8 Mtrs
10 8 Supplying and fixing G.I. pipe of 32 mm dia meduim duty for protection of UG cable as required 12 12 Mtrs
11 9 Supplying and fixing of 09 watt LED ball lamp. BI01010001010000000000000515BI0100001127 6 Each
12 10 Supplying and fixing of 225/250 mm sweep, non-metalic exhaust fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing opening including making hole to suit the size including connections etc. as required. BI01010001010000000000000515BI0100001128 3 Each
13 11 Supplying & laying of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1 KV Grade of size 2X6 Sq. MM conf to IS: 7098 (Part-I) direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. BI01010001010000000000000515BI0100001129 52 Mtr
14 12 Supplying & laying of one number XLPE insulated and PVC sheathed, armoured aluminium power cable of 1.1 KV Grade of size 2X6 Sq. MM conf to IS: 7098 (Part-I) in the existing METAL PIPE / OPEN as required. BI01010001010000000000000515BI0100001130 14 Mtr
15 13 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) (a) 4 way double door BI01010001010000000000000515BI0100001131 1 Each
16 14 Add Cost Index @ 22.88% on DSR 2018 (from S.N. 01 to 07) on amount 14999.00 BI01010001010000000000000515BI0100001135 1 FIXED
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail