Sales : +91-777 804 8217
| Name of Work :Augmentation of Dergoan Water Supply Scheme | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | A) Construction of Aerator , Raw water channel, Filter house and Mechanical piping works | |||
| 2 | 2 | Earth work in excavation fin foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing , ramming , watering etc. and removal of surplus earth with 50 mtr lead and lift upto 1.5 mtr all complete as directed-(a) Ordinary soil | 250.99 | Cum | |
| 3 | 3 | (B) Extra over item no 1.00 above for each 1.00 mtr depth or pert thereof beyomd the initial depth of 2.00 mtr | 8 | Cum | |
| 4 | 4 | Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered) -A) Up to a depth of 1.5 meter. | 354.25 | Sqm | |
| 5 | 5 | B) From depth of 1.5 meter to 3.00 meter. | 96.45 | Sqm | |
| 6 | 6 | Supplying and filling sand gravel in foundation, trenches of column footings over slushy soil including local carriage of materials within 8.00 Km pumping out water, ramming etc complete for strengthening the bearing capacity of the soil as directed and specified including payment of land compensation, forest loyalty, sale tax and other duties and taxes as may be necessary. | 12 | Cum | |
| 7 | 7 | (B)Extra lead per Km truck carriage for sand gravel beyond the initial lead of 8 km.( Quarry distance from site is 45 Km; So additional lead is 45-8= 37.00 Km | 444.15 | Cum/km | |
| 8 | 8 | Sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc complete as directed and specified including payment of land compensation, forest loyalty, sale tax and other duties and taxes as may be necessary.--(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | 68.13 | Cum | |
| 9 | 9 | Providing Brick soling in foundation and floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade etc, if necessary dewatering complete- Brick on flat soling. | 222.4 | Sqm | |
| 10 | 10 | Providing & laying 25 mm thick Damp Proof Coarse with cement concrete in prop.1:1.5:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | 2.42 | Sqm | |
| 11 | 11 | Plain Cement concrete works with coarse aggregate of sizes 13 mm to 32 mm in foundation bed for footing,steps,walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately -In proportion 1:3:6 | 20.27 | Cum | |
| 12 | 12 | Providing and laying controlled cement concrete of grade M 30 with 20 mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost form work and reinforcement for R.C.C. work as directed in sub structures up to plinth level -for foundation, footing ,column with base, tie and plinth beams....etc | |||
| 13 | 13 | a)In sub-structure- Foundation, footing, tie beam and the like upto plinth level. | 45.56 | Cum | |
| 14 | 14 | b)In super structure-Lintel, chajja,column, beams, slab , staire case etc upto first floor level. | 103.55 | Cum | |
| 15 | 15 | Providing and laying controlled cement concrete of grade-M25 with 20 mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost form work and reinforcement for R.C.C. work a) In sub-structure- Foundation, footing, tie beam and the like upto plinth level. | 10.42 | Cum | |
| 16 | 16 | Extra for providing and mixing normal Plastisizer Plastiment BV 40 of Sika India Ltd. /Dr. Sealkit Superplast WR 40 (Asian Chemicals)/Rheobuild 1100i of BASF@ 0.5%-0.8% by weight of cement in concrete for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. as specified and directed by the Department complete at all levels.(iii) In 1 : 1 : 2 (1cement : 1coarse sand : 2aggregate) or M-25 grade. | 101.35 | Cum | |
| 17 | 17 | Extra for RCC works in each subsequent floor or part thereof above 1st floorlevel. | 48.29 | Cum | |
| 18 | 18 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S code for RCC work/ RB walling including straightening , cleaning , cutting and bending to proper shapes and lengths per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, support, chairs, spacers complete ( up to 1st floor level- a) From Primary Producer: TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel /RINL- (ii)Super Ductile (SD) TMT reinforcement bars | 20952.8 | Kg | |
| 19 | 19 | B) Extra for reinforcement work above first floor level | 6259.3 | Kg | |
| 20 | 20 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the same for insitu reinforced concrete and plain concrete works in : (a) In foundation etc | 57.05 | Sqm | |
| 21 | 21 | b) C/S of tie beam, etc | 139.17 | Sqm | |
| 22 | 22 | c) C/S of square column | 312.29 | Sqm | |
| 23 | 23 | d) Sides and soffits of beam | 161.07 | Sqm | |
| 24 | 24 | e) Flat surface-suspended floors, roofs, landings | 216.91 | Sqm | |
| 25 | 25 | f) Stair case with sloping soffits | 50.92 | Sqm | |
| 26 | 26 | g) In super structure- In vertical wall | 421.08 | Sqm | |
| 27 | 27 | d) In suspended floor, slab, landing,etc | 30.34 | Sqm | |
| 28 | 28 | Extra for centering and shuttering for each subsequent floor or part thereof above first floor level. | 158.35 | Sqm | |
| 29 | 29 | Extra for centering and shuttering for each subsequent floor or part thereof above first floor level mentioned in item no21 | 375.14 | Sqm | |
| 30 | 30 | Brick work in cement mortar with first class bricks including racking out joints and dewatering if necessary and curing complete as directed in sub structures up to plinth level with 1:3 mix mortar. | 26.59 | Cum | |
| 31 | 31 | 112 mm thick reinforced brick wall in proportion 1:5, reinforced with two lines of M.S. rod/ tor steel as specified embedded in 38mm thick concrete course in proportion 1:2:4 with coarse aggregate 12 mm down at every fourth courses embedded with protruding rod as directed (M.S.rod/Tor steel shall be measured and paidseperately) in super structures above plinth up to 1st floor level. | 235.93 | Sqm | |
| 32 | 32 | Extra for brick walling for each subsequent floor or part thereof above first floor level as mentioned in item nos.32 | 209.07 | Sqm | |
| 33 | 33 | Providing wood work in frames (chowkhat) of doors, windows, clearstory windows and other similar works in fixed in position in contact with C.C.or brick masonry wall including supplying , fitting and fixing with and M.S. hold fast (40mm X 3mm X 250) as per design embedded in cement concrete block in proportion 1:2:4 and with 2 coats of kiricide oiling to the timber faces in contact with CC and masonry as directed and specified.(a) With 1st class timber (Sundi /Bonsum) | 0.131 | Cum | |
| 34 | 34 | Providing, fitting and fixing steel window (openable ) of standard rolled steel sections as per relevant IS code -1038 joints mitred and welded with 15 mm X 3 mm X 100 mm lug embedded in cement concrete block of M-10 ( 1:3:6) grade including providing and fixing of projecting hinges( not more than 65mm and not less than 15 mm wide) bolting device and steel handles, peg stays of 300 mm long each complete including providing 12 mm X 12mm square bar duly welded to steel frame at not more 120 mm centre to center, applying a priming coat of red lead paint etc. complete as per drawing Openable shutter | 18.56 | Sqm | |
| 35 | 35 | Providing and fixing clear sheet glass bedded in putty and fixed with / without wooden beadings including necessary cuttings of glass to required sizes (payment for wooden beads shall be made seperately). -5 mm thick. | 17.29 | Sqm | |
| 36 | 36 | Providing, fitting and fixing 35mm thick full paneled doors/windows including oxidized M.S. butt hinges(100 mmX 75 mmX 3.55 mm) 6 nos. with necessary screws.- 35 mm thick shutter with 1st class Bola/ Gamari wood. | 3.59 | Sqm | |
| 37 | 37 | Supplying , fitting and fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodized to bright natural matt & satin finished. | |||
| 38 | 38 | a) Sliding door bolts of size-250 mmX 16 mm | 2 | Each | |
| 39 | 39 | b)Tower bolt-250mm X 12 mm | 4 | Each | |
| 40 | 40 | c) Door/ handle-150 mm size | 4 | Each | |
| 41 | 41 | 25 mm thick cement concrete topping 1:2:4 (1 cement: 2 coarse sand :4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish ( base concrete to be measured and paid separately) to be laid in panels including curing complete as directed. | 346.34 | Sqm | |
| 42 | 42 | Cement plaster skirting with cement mortar in proportion 1:3 (1 cement :3 coarse sand) finished with floating coat of neat cement including rounding of junction with floor- 20 mm thick | 431.61 | Sqm | |
| 43 | 43 | 15 mm plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed-In cement mortar 1:6. | 766.85 | Sqm | |
| 44 | 44 | 10mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed.- In cement mortar 1:3 | 310.05 | Sqm | |
| 45 | 45 | Extra for plastering on ceiling and soffits of stairs up to first floor level ( instead of plastering on walls) including curing complete as directed. - In single coat plaster | 310.05 | Sqm | |
| 46 | 46 | Extra for interior plastering above first floor level for every additional floor or part thereof including curing complete as directed. - In single coat plaster | 377.32 | Sqm | |
| 47 | 47 | Extra for exterior plastering over wall up to a height of first floor level above G.L. including curing complete as directed. - In single coat plaster | 310.05 | Sqm | |
| 48 | 48 | Extra for exterior plastering for wall for every additional floor or part thereof beyond first floor level including curing complete as directed. - In single coat plaster | 275.19 | Sqm | |
| 49 | 49 | White washing with lime on wall surfaces (two coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt, dust, mortar drops and other foreign matter and including preparing the surface even and sand papered smooth. | 292.47 | Sqm | |
| 50 | 50 | Supplying, fitting,and fixing M.S. angles, M.S. flats, bolts and nuts including painting with red lead paint one coat complete as directed- M.S. angles, pipes etc | 190.8 | Kg | |
| 51 | 51 | Applying one coat cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | 831.04 | Sqm | |
| 52 | 52 | Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface( two coats) to give an even shade after thoroughly brooming the surfaces to remove all dirt and remains of all loose powdered materials. | 831.04 | Sqm | |
| 53 | 53 | Finishing old / new with waterproffing weather coat smooth antifungal exterior painting of approved make of Berger paint of required shade after cleaning the surface etc.including scaffolding complete as directed at all levels ( two coats) | 5.19 | Sqm | |
| 54 | 54 | Painting two coats (excluding priming coat) over new wood and wood based surfaces over 100 mm in girth/ width with enamal paint of approved brand and manufacture ( Asian paint/ Berger Paint / ICI paint / J&N paint / Nerolac ) to give an even shade including preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting . | 5.19 | Sqm | |
| 55 | 55 | Applying prime coat over new steel and other metal surfaces over 100 mm in girth/ width after preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matterand scoured with wire brushes, fine steels, wood scrapers and sand papering- with ready mixed \" Red lead / Red oxide primer. | 43.4 | Sqm | |
| 56 | 56 | Painting two coats ( excluding priming coat) over new steel and other metal surfaces over 100 mm in girth/ width with enamel paint of approved brand and manufacture (Asian paint / Berger paint / ICI paint / J&N paint / Nerolac ) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter. | 43.4 | Sqm | |
| 57 | 57 | Applying 2 coats of 1mm thick elastomeric cementitious waterproofing coating Brushbond RFX of Fosroc Chemicals /Dr. Sealkit Flexbond AP 122 C (Asian Chemicals) / MASTERSEAL 550EL of BASF for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. after proper surface preparation and soaking the surface with water prior to application complete as specified and directed by the Department at all levels. | 209.82 | Sqm | |
| 58 | 58 | B)MACHNICAL ARRANGEMENT FOR TREATEMENT PLANT | |||
| 59 | 59 | Labour charge for carrying laying in position cast iron double flanged pipe in line level all complete as directed | |||
| 60 | 60 | 80mm dia pipe | 78 | Rm | |
| 61 | 61 | 250mm dia pipe | 79.2 | Rm | |
| 62 | 62 | Providing flanged foints to double flanged CI pipes and specials with testing of joints and including supplying bolts, nuts and 3mm thick rubber insertion sheet all complete as directed | |||
| 63 | 63 | 80mm dia. | 20 | Each | |
| 64 | 64 | 250mm dia. | 75 | Each | |
| 65 | 65 | Labour charge for carrying, placing in position, fitting and fixing CI sluice valve ( with wheel and cap) CI reflex valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. ( the tail pieces if required will be paid seperately) all complete as directed ( one valve and two flanged joints). | |||
| 66 | 66 | 80mm dia. | 2 | Each | |
| 67 | 67 | 150mm dia | 4 | Each | |
| 68 | 68 | 200mm dia. | 2 | Each | |
| 69 | 69 | 250mm dia. | 8 | Each | |
| 70 | 70 | 300mm dia. | 2 | Each | |
| 71 | 71 | Labour charge for carrying and laying in position D.I. / C.I.S.& S S&S , flange , Plain ended C.I. specials such as Tee , Bends , Collars , Tappers and Caps etc complete as directed . | 15 | Qntl. | |
| 72 | 72 | Providing 12mm dia.hole for lateral @ 215mm center to center spacing | 700 | Each | |
| 73 | 73 | Providing Pipe for areator arrangment 65mm dia.GI medium pipe including making of Round shape suitable for the existing size and making hole for areation all complete including tee, bend etc | 1 | Job | |
| 74 | 74 | Supplying of centrifugally cast(spun) iron double flange pressure pipes conforming to ISI specification in standard working length . | |||
| 75 | 75 | 80mm dia. | 390 | Kg | |
| 76 | 76 | 250mm dia. | 6541.92 | Kg | |
| 77 | 77 | Supplying and devilary of cast iron double flanged (CI/DF) sluice valve with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest ammendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified. | |||
| 78 | 78 | 80mm dia | 2 | Each | |
| 79 | 79 | 150mm dia. | 4 | Each | |
| 80 | 80 | 200mm dia. | 8 | Each | |
| 81 | 81 | 250mm dia. | 2 | Each | |
| 82 | 82 | 300mm dia. | 2 | Each | |
| 83 | 83 | Supplying and devilary of ISI marked DI double socketed fittings such as Tee , Bends , Reducer , Tappers and Caps etc class k-12 conforming to IS 9523-2000 of PN 1.6 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 DI pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-1985 | 1500 | Kg | |
| 84 | 84 | Supply of Galvanized Iron(GI) Pipe as per the IS specification conforming to IS-1239(pt-I), 1990 medium pipe of 100 mm dia for Air Blower line | 22 | Rm | |
| 85 | 85 | Supply of Galvanized Iron(GI) for Air blower line ( heavy duty) as per the IS specification conforming to IS-1239(pt-I), 1990 | |||
| 86 | 86 | 100mm dia. Tee | 2 | Each | |
| 87 | 87 | 100mm dia. Union socket | 2 | Each | |
| 88 | 88 | 100mm dia. Elbow | 8 | Each | |
| 89 | 89 | 100mm dia.900 bend | 4 | Each | |
| 90 | 90 | 100 mm dia. Socket | 8 | Each | |
| 91 | 91 | 100mm dia. 6'' nipple | 6 | Each | |
| 92 | 92 | 100mm dia full way valve. | 2 | Each | |
| 93 | 93 | Supply of full Thread Nuts & Bolt suitable for DI pipe fitting and specials | 170 | Kg | |
| 94 | 94 | Supply of rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. The PCD and flange hole dimension should conform to IS 1538/1993 and gasket should be suitable for making flanged joint. | 100 | Kg | |
| 95 | 95 | Supply of Galvanized Iron(GI) Pipe as per the IS specification conforming to IS-1239(pt-I), 1990 medium pipe of 15mm dia for Alum & Bleaching dozer | 80 | Rm | |
| 96 | 96 | Supply, installation, testing and commissioning of 20 HP capacity of electrical driven Air blower suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/delta/star complete set as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as base frame, coupling, guard foundation, bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect including construction of foundation all complete including connection with Air Blower line in all respect. | 20 | Each | |
| 97 | 97 | C) Providing Filter Media (Filter bed size- 2x3.00 m x 3.95 m) | |||
| 98 | 98 | Supplying and placing of River gravel for Rapid Gravity filter effective size following sixe and free from dust, clay, fine particles and dirt of every description.\n40 to 50 mm size : 200mm \n32 to 40 mm size : 100mm\n12 to 20 mm size : 100mm\n6 to 12 mm size: 100mm\n | 11.85 | Cum | |
| 99 | 99 | Supplying and placing of coarse sand filter for Rapid Gravity filter effective size 0.06mm to 0.50 mm and uniformity coefficient between 1.7 to 1.3 all complete as directed sand shall be hard and quartz and quartzite and free from dust, clay, fine particles and dirt of every description. | 21.33 | Cum | |
| 100 | 100 | D) Distribution pipe net work | |||
| 101 | 101 | Earth work in excavation in black toping road surface (average thickness of black toping 35mm) including the removal of road metal, boulders and refilling the same properly and restore the road surface to its original condition (except black toping as the black toping to be done by the PWD on necessary payment all complete as directed.For 100mm dia to 300 mm dia DI pipe | 2532 | M2 | |
| 102 | 102 | Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders and including restoration of road surface original condition all complete as directed.For 100mm dia to 300 mm dia DI pipe | 3376 | M2 | |
| 103 | 103 | Earth in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50 M lead and lift up to 1.5 M all complete as directed including boiling out water where necessary.b) Bastic land, tillah soil, hard soil, mixed with moram gravel and boulder up to one man size.For 100mm dia to 300 mm dia DI pipe. | 48.5 | M3 | |
| 104 | 104 | Labour charge for carrying and laying DI pipes and specials (Class-7) in position, in line and level complete as directed. | |||
| 105 | 105 | 100 mm dia. pipe | 4100 | RM | |
| 106 | 106 | 150 mm dia. pipe | 1800 | RM | |
| 107 | 107 | 200 mm dia. pipe | 362 | RM | |
| 108 | 108 | 250 mm dia. pipe | 1025 | RM | |
| 109 | 109 | 300mm dia. pipe | 1261 | RM | |
| 110 | 110 | Providing rubber gasket joints to C.I. pipes and specials with testing of joints including carriage of the materials but excluding the cost of rubber gasket all complete as directed. | |||
| 111 | 111 | 100 mm dia. pipe | 820 | Each | |
| 112 | 112 | 150 mm dia. pipe | 360 | Each | |
| 113 | 113 | 200 mm dia. pipe | 73 | Each | |
| 114 | 114 | 250 mm dia. pipe | 205 | Each | |
| 115 | 115 | 300mm dia. pipe | 252 | Each | |
| 116 | 116 | Labour charge for carrying, placing in position S & S flanged, plain ended C.I Specials such as tees, bends, collars, tappers and caps etc all complete as directed.A) Al Socketed Tee, Tee, all type of Bend, Reducer, Flange adoptor etc | 83.25 | Qntl. | |
| 117 | 117 | Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxe valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints | |||
| 118 | 118 | 100 mm dia. pipe | 6 | Each | |
| 119 | 119 | 150 mm dia. pipe | 3 | Each | |
| 120 | 120 | 200 mm dia. pipe | 2 | Each | |
| 121 | 121 | 250 mm dia. pipe | 2 | Each | |
| 122 | 122 | 300mm dia. pipe | 1 | Each | |
| 123 | 123 | Labour Charge carrying, fitting and fixing CI Double Air valve complete with supplying bolts, Nuts, 3mm thick rubber incertation etc. All complete as directed | |||
| 124 | 124 | 80 mm dia. | 5 | Each | |
| 125 | 125 | 65 mm dia. | 3 | Each | |
| 126 | 126 | Labour charge for cutting DI pipe of different dia for required length as directed. | 100 | Each | |
| 127 | 127 | Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge . | |||
| 128 | 128 | a) Size -1000x1000x1200 | 14 | Each | |
| 129 | 129 | b) Size -1200x1200x1201 | 4 | Each | |
| 130 | 130 | Supply, delivery and stacking of centrifugally cast (spun) Ductile Iron Presser Pipes ISI Marked, Class K-7 with socket and spigot ends conforming to IS:8329/2000 of standard working lengths 5.50 meter and 6.00 meter with inside inside cement mortar lining of 3 mm nominal thickness and outside Blue Epoxy coating suitable against longitudinal bending and differential settlement, relatively smooth walls, chemically inert with respect to soil and water. | |||
| 131 | 131 | 100 mm dia. | 4100 | Rm | |
| 132 | 132 | 150 mm dia. | 1800 | Rm | |
| 133 | 133 | 200 mm dia | 362 | Rm | |
| 134 | 134 | 250 mm dia | 1025 | Rm | |
| 135 | 135 | 300 mm dia | 1261 | Rm | |
| 136 | 136 | Supplying and devilary of ISI marked DI double socketed fittings such as Tee , Bends , Reducer , Tappers and Caps etc class k-12 conforming to IS 9523-2000 of PN 1.6 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 DI pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-1985 | 8325 | kg | |
| 137 | 137 | Supplying and devilary of ISI Marked CI Jeffy Joints Collar (Flanged Adopter) with full threaded Nuts & Bolts for use with DI pipes Conforming to IS:14846/2000 with up to date amendments of following sizes. (PN-1.6) | |||
| 138 | 138 | i) 100 mm dia. | 10 | Each | |
| 139 | 139 | ii) 150 mm dia. | 4 | Each | |
| 140 | 140 | ii) 200 mm dia. | 6 | Each | |
| 141 | 141 | ii250 mm dia. | 4 | Each | |
| 142 | 142 | ii) 300mm dia. | 4 | Each | |
| 143 | 143 | Supplying and devilary of ISI Marked CI Jeffy Joints (Mechanical Collar Coupling) with full threaded Nuts & Bolts for use with DI pipes Conforming to IS:14846/2000 with up to date amendments of following sizes. (PN-1.6) | |||
| 144 | 144 | i) 100 mm dia. | 10 | Each | |
| 145 | 145 | ii) 150 mm dia. | 4 | Each | |
| 146 | 146 | ii) 200 mm dia. | 6 | Each | |
| 147 | 147 | ii250 mm dia. | 4 | Each | |
| 148 | 148 | ii) 300mm dia. | 4 | Each | |
| 149 | 149 | Supplying and devilary of cast iron double flanged (CI/DF) sluice valve with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest ammendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified. | |||
| 150 | 150 | 100 mm dia. pipe | 8 | Each | |
| 151 | 151 | 150 mm dia. pipe | 2 | Each | |
| 152 | 152 | 200 mm dia. pipe | 4 | Each | |
| 153 | 153 | 250 mm dia. pipe | 3 | Each | |
| 154 | 154 | 300mm dia. pipe | 1 | Each | |
| 155 | 155 | Supplying ,devilary, fitting and fixing of 98.5 mm dia resilient seated Cast Iron Air Relief Valves conforming to IS:14845-2000 to DI water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified. | |||
| 156 | 156 | 76.63 mm dia. | 5 | Each | |
| 157 | 157 | 65 mm dia. | 3 | Each | |
| 158 | 158 | Supply of full Thread Nuts & Bolt suitable for DI pipe fitting and specials | 200 | Kg | |
| 159 | 159 | Supply of rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. The PCD and flange hole dimension should conform to IS 1538/1993 and gasket should be suitable for making flanged joint. | 100 | Kg | |
| 160 | 160 | Supplying of additional quantity of rubber ring of EPDM quality (Tyton Joint) as per IS:5382-1985 and its upto date amendment as applicable suitable for DI pipes | |||
| 161 | 161 | 100 mm dia | 30 | Each | |
| 162 | 162 | 150 mm dia | 10 | Each | |
| 163 | 163 | 200 mm dia | 20 | Each | |
| 164 | 164 | 250 mm dia | 15 | Each | |
| 165 | 165 | 300 mm dia | 20 | Each | |
| 166 | 166 | E) Raw Water Pumping main for 200 mm dia | |||
| 167 | 167 | Earth work in excavation in black toping road surface (average thickness of black toping 35mm) including the removal of road metal, boulders and refilling the same properly and restore the road surface to its original condition (except black toping as the black toping to be done by the PWD on necessary payment all complete as directed. | 160 | M2 | |
| 168 | 168 | Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders and including restoration of road surface original condition all complete as directed. | 160 | M2 | |
| 169 | 169 | Earth in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50 M lead and lift up to 1.5 M all complete as directed including boiling out water where necessary.b) Bastic land, tillah soil, hard soil, mixed with moram gravel and boulder up to one man size. | 160 | M3 | |
| 170 | 170 | Labour charge for carrying and laying DI pipes and specials (Class-k-9) in position, in line and level complete as directed. | 1500 | RM | |
| 171 | 171 | Providing rubber gasket joints to C.I. pipes and specials with testing of joints including carriage of the materials but excluding the cost of rubber gasket all complete as directed. | 290 | Each | |
| 172 | 172 | Labour charge for carrying, placing in position S & S flanged, plain ended C.I Specials such as tees, bends, collars, tappers and caps etc all complete as directed. | 9.16 | Qntl. | |
| 173 | 173 | Labour charge for carrying, providing and fixing non return valve of approved quality including supplying jointing materials all complete as directed. | 1 | Each | |
| 174 | 174 | Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxe valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints | 1 | Each | |
| 175 | 175 | Labour Charge carrying, fitting and fixing CI Double Air valve complete with supplying bolts, Nuts, 3mm thick rubber incertation etc. All complete as directed | 3 | Each | |
| 176 | 176 | Labour charge for cutting DI pipe of different dia for required length as directed. | 25 | Each | |
| 177 | 177 | Construction of RCC thrust block as per standard design and drawing as directed by the Engineers-In-Charge . Size 1.20 m X 1.20 M x !.20 M | 8 | Each | |
| 178 | 178 | Construction of RCC pillar as per standard design and drawing as directed by the Engineers-In-Charge .Size-0.30 m x 0.30 m x 2.50 m | 6 | Each | |
| 179 | 179 | Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge . Size- 1.20 m x 1.20 m x1.20 m | 1 | Each | |
| 180 | 180 | Supply, Delivery , laying , testing and commissiong Stacking of Centrifugally Cast (Spun) Ductile Iron of 200 mm dia. (Class, K-9) Pressure Pipes ISI Marked with Socket & Spigot ends conforming to IS 8329: 2000 of standard working lengths 5.50 meter or 6.00 meter with inside cement mortar lining of 3 mm nominal thickness and outside Blue Epoxy coating suitable against longitudinal bending and differential settlement, relatively smooth walls, chemically inert with respect to soil and water including DI specials like bend ,tee etc as required for laying of said pipe lines and hydraulic testing of the same, . | 1500 | RM | |
| 181 | 181 | Supplying and devilary of ISI marked DI double socketed fittings such as Tee , Bends , Reducer , Tappers and Caps etc class k-12 conforming to IS 9523-2000 of PN 1.6 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 DI pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-1985 | 472 | Kg | |
| 182 | 182 | Supplying and devilary of ISI Marked CI Jeffy Joints Collar (Flanged Adopter) with full threaded Nuts & Bolts for use with DI pipes Conforming to IS:14846/2000 with up to date amendments of following sizes. (PN-1.6) 200 mm dia | 6 | Each | |
| 183 | 183 | Supplying and devilary of resilient seated Ductile Iron Horizontal Non -Return Valves conforming to IS:5312/2004 and PN 1.6 with up to date amendments to DI water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified of 200 mm dia | 1 | Each | |
| 184 | 184 | Supplying and devilary of cast iron double flanged (CI/DF) sluice valve 200 mm dia with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest ammendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified. | 1 | Each | |
| 185 | 185 | Supplying ,devilary, fitting and fixing of 98.5 mm dia resilient seated Cast Iron Air Relief Valves conforming to IS:14845-2000 to DI water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified. | 1 | Each | |
| 186 | 186 | Supply of full Thread Nuts & Bolt suitable for DI pipe fitting and specials | 100 | Kg | |
| 187 | 187 | Supply of rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. The PCD and flange hole dimension should conform to IS 1538/1993 and gasket should be suitable for making flanged joint. | 70 | Kg | |
| 188 | 188 | F) Construction of Pump houses | |||
| 189 | 189 | Earth work in excavation in slushy/ marshy soil, decomposed organic matter mixed with brickbats, broken glass panes, broken earthen pots etc. removal of stumps and other deleterious matter in the proposed building site including constant water pumping | 23.2044 | M3 | |
| 190 | 190 | Providing brick soling in foundation and floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade etc, if necessary dewatering complete- Brick on flat soling. | 56.9 | M2 | |
| 191 | 191 | Sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc complete as directed and specified including payment of land compensation, forest loyalty, sale tax and other duties and taxes as may be necess | 17.04 | M3 | |
| 192 | 192 | Providing & laying 25 mm thick Damp Proof Coarse with cement concrete in prop.1:1.5:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curi | 3.02848 | M2 | |
| 193 | 193 | Plain Cement concrete works with coarse aggregate of sizes 13 mm to 32 mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be m | 4.239 | M3 | |
| 194 | 194 | Providing and laying R.C.C. work in proportion 1:1.5:3 including dewatering if necessary and curing complete but excluding cost form work and reinforcement for R.C.C. work as directed in sub structures up to plinth level -for foundation, footing ,column w | |||
| 195 | 195 | a) In sub-structure- Foundation, footing, tie beam and the like upto plinth level. | 5.58 | M3 | |
| 196 | 196 | b) In super structure-Lintel, chajja, column, beams, slab , stair case etc upto first floor level. | 10.5035 | M3 | |
| 197 | 197 | Supplying, fitting & fixing in position reinforcements bars conforming to relevant IS Code for R.C.C. work / RB Walling including straightening , cleaning , cutting and bending to proper shape & length as per detail, supplying and binding with 20G anne | 20 | Qntl | |
| 198 | 198 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the sam | 8.64 | M2 | |
| 199 | 199 | b) C/s of tie beam | 11.76 | M2 | |
| 200 | 200 | c) Column, pier, post | 54 | M2 | |
| 201 | 201 | d) Sides and soffits beam, lintel, horizontal ties. | 39.984 | M2 | |
| 202 | 202 | e) Flat surface such as soffits of suspended floors, chajjas and the like. | 50.8528 | M2 | |
| 203 | 203 | Brick work in cement mortar with first class bricks including racking out joints and dewatering if necessary and curing complete as directed in sub structures up to plinth level with 1:5 mix mortar. | 7.50402 | M3 | |
| 204 | 204 | 112 mm thick reinforced brick wall in proportion 1:5, reinforced with two lines of M.S. rod/ tor steel as specified embedded in 38mm thick concrete course in proportion 1:2:4 with coarse aggregate 12 mm down at every fourth courses embedded with protrudin | 101.452 | M2 | |
| 205 | 205 | Providing wood work in frames (chowkhat) of doors, windows, clearstory windows and other similar works in fixed in position in contact with C.C.or brick masonry wall including supplying , fitting and fixing with and M.S. hold fast (40mm X 3mm X 250) (a) With 1st class timber ( Hollock/Bonsum) | 0.2352 | M3 | |
| 206 | 206 | Providing, fitting and fixing fully glazed window without intermediate sash bars including oxidised M.S butt hinges (75mm x 60mm x 3.15mm) 2nos.on each leaf and 3 nos. on single leaf (glass panes to be measured and paid separately) W1200X1350 | 7.9704 | M2 | |
| 207 | 207 | Providing and fixing clear sheet glass bedded in putty and fixed with / without wooden beadings including necessary cuttings of glass to required sizes (payment for wooden beads shall be made seperately).-5 mm thick. a) Area of glass panes exceeding 0.52 Sqm. W1200X1350 | 6.0264 | M2 | |
| 208 | 208 | Providing, fitting and fixing 35mm thick full paneled doors/windows including oxidized M.S. butt hinges(100 mmX 75 mmX 3.55 mm) 6 nos. with necessary screws.- 35 mm thick shutter with 1st class Bola/ Gamari wood. | 4.2444 | M2 | |
| 209 | 209 | Supplying , fitting and fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete ( anodized | |||
| 210 | 210 | a) Sliding door bolts of size-250 mmX 16 mm | 2 | Nos. | |
| 211 | 211 | b)Tower bolt- (i) 250mm X 12 mm | 4 | Nos. | |
| 212 | 212 | (ii) 100mm X10mm dia tower bolt | 12 | Nos. | |
| 213 | 213 | c) Door/ handle- (i) 150 mm size | 4 | Nos. | |
| 214 | 214 | (ii) 100 mm size handle for window | 6 | Nos. | |
| 215 | 215 | 25 mm thick cement concrete topping 1:2:4 (1 cement: 2 coarse sand :4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish ( base concrete to be measured and paid separately) to be laid in panels including curing com | 77.46 | M2 | |
| 216 | 216 | Cement plaster skirting with cement mortar in proportion 1:3 (1 cement :3 coarse sand) finished with floating coat of neat cement including rounding of junction with floor 20 mm thick | 29.88 | M2 | |
| 217 | 217 | 15 mm plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directe | 181.36 | M2 | |
| 218 | 218 | 10mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed.(APW | 57.396 | M2 | |
| 219 | 219 | Extra for plastering on ceiling and soffits of stairs up to first floor level ( instead of plastering on walls) including curing complete as directed In single coat plaster | 57.396 | M2 | |
| 220 | 220 | Extra for exterior plastering over wall up to a height of first floor level above G.L. including curing complete as directed In single coat plaster | 105.6 | M2 | |
| 221 | 221 | White washing with lime on wall surfaces (two coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt, dust, mortar drops and other foreign matter and including preparing the surface even and sand papered smooth. | 46.02 | M2 | |
| 222 | 222 | Supplying, fitting, and fixing M.S. grills- Plain gerill fixed to wooden frame | 107.738 | Kg | |
| 223 | 223 | Applying one coat cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth | 192.736 | M2 | |
| 224 | 224 | Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface( two coats) to give an even shade after thoroughly brooming the surfaces to remove all dirt and remains of all loose powdered mater | 192.736 | M2 | |
| 225 | 225 | Applying prime coat over new wood and wood based surfaces over 100 mm in girth/ width after and including preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting with ready mixed white wood D1200X 2100 paneled door and W 1200X1350 | 19.584 | M2 | |
| 226 | 226 | Painting two coats (excluding priming coat) over new wood and wood based surfaces over 100 mm in girth/ width with enamel paint of approved brand and manufacture ( Asian paint/ Berger Paint / ICI paint / J&N paint / Nerolac ) to give an even shade include | 19.584 | M2 | |
| 227 | 227 | Applying prime coat over new steel and other metal surfaces over 100 mm in girth/ width after preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper | 2.52 | M2 | |
| 228 | 228 | Painting two coats ( excluding priming coat) over new steel and other metal surfaces over 100 mm in girth/ width with enamel paint of approved brand and manufacture (Asian paint / Berger paint / ICI paint / J&n paint / Nerolac ) to give an even shade in | 2.52 | M2 | |
| 229 | 229 | G)Construction of security Fencing with Gate at Treatment Palnt site | |||
| 230 | 230 | Supplying, fitting and fixing galvanised barbed wire fencing with seven strands of barbed wire 12 S. W. G .x 2plies x 4 points at 75mm apart with angle iron intermediate fencing posts not more than 1800mm apart and straining and end post etc. as necessary to be fitted with straining eye bolts and staples etc. complete as directed, specification of the angle iron post as given below. \na) Intermediate post 35mm x35mm x5mm x1800mm long bottom torched and duly slotted.\nb) Straining post 65mm x 65mm x 6mm x 1820mm long with 2 stays of 35mmx35mmx1520mm long and 3 base plates 200mm x 200mm x 5mm, duly slotted to take eye bolts etc.\nc) Corner posts 65mm x 65mm x 6mm x1820mm long with 2 stays of 35mm x 35mm x 5mm x 1 670 mm and 3 base plates 200mm x 200mm x 5mm,duly slotted to take eye bolts etc. \nd) Straining or end posts 65mmx 65mm x 6mmx 1820mm long with 1 stays of 35mm x 35mm x 5mmx 1820 mm long with base plates 200mmx 200mm x 5mm, duly slotted to take eye bolts etc. \n(All the angle iron posts to be embeded 600mm in C.C.pillars of size 300mmx300mmx600mm in prop.1: 3: 6 and one coat of anticorrosive ready mixed painting to all iron works) including excavation of foundation trenches for C.C. blocks and refilling and removal of surplus soil after completion of works.\n | 280 | M | |
| 231 | 231 | Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) st | 3 | Qtl | |
| 232 | 232 | H)CONSTRUCTION OF ELECTRICAL PROWER LINE DRAWING AND SUBSTATION AT TREATEMENT PLANT AND DEEP TUBEWELL SITE | |||
| 233 | 233 | Supplying, installation testing and commissioning of the following rating copper wound indoor/outdoor type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended upto date upto200 KVA starrating upto 5star,above 200 KVA as per CEA guidelines for losses along with (i)63 KVA, 50Hz. 11/0.433KV. Oil filled transformer with Off Circuit tap change. | 1 | Nos. | |
| 234 | 234 | (ii) 25 KVA 50Hz. 11/0.433KV. Oil filled transformer with Off Circuit tap change. | 1 | Nos. | |
| 235 | 235 | Supplying and erection of PSC pole 7.50 m long the pole, the pole is to be erected in 1:2:4 plain cement concrete foundation of size 1.50m X 0.45m x 0.45m having PCC base foundation 15cmx 60cmx 60cm including edge brick soling and plasttering above GL portion(0.30m) complete with excavation of earth, handling of surplus soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department. PSC pole 7.50 m long | 6 | Nos. | |
| 236 | 236 | Supplying including installation of 100 mm dia C.I. Earth Pipe as required and directed by the Department.100 mm dia C.I. Earth Pipe | 4 | Nos. | |
| 237 | 237 | Supplying including fitting and fixing G.I Channel X Arm 100X50X6 x2200 mm size as required and directed by the Department, including arrangement of Supervision Certificate from cmpetant authority of APDCL.G.I Channel X Arm 100X50X6 x2200 | 2 | Nos. | |
| 238 | 238 | Supplying including fitting and fixing 11 KV Disc Insulator, 70 KN in the existing MS Channel as required and directed by the Department. 11 KV Disc Insulator, 70 KN | 10 | Nos. | |
| 239 | 239 | Supplying including fitting and fixing 11 KV Pin Insulator with pin as required and directed by the Department. 11 KV Pin Insulator | 10 | Nos. | |
| 240 | 240 | Supplying and fixing of 11 KV, 400 A Gang Operated Switch with all accessories complete as required and directed by the Department. Gang Operated Switch, | 2 | Nos. | |
| 241 | 241 | Supplying and fixing of 11 KV, 150 A D.O. Fuse set complete as required and directed by the Department. 11 KV, 150 A D.O. Fuse set | 2 | Nos. | |
| 242 | 242 | Supplying and fixing of 11 KV, 5KA lighting arrestor(Poly) set complete as required and directed by the Department. 11 KV, 5KA lighting arrestor | 2 | Nos. | |
| 243 | 243 | Supplying and erection of H.T. stay set complete (Galvanized) with 19mm dia x 1.8m long stay rod, anchor plate of size 30cm x 30cm x 6.4mm, thimble stay clamps, turn buckle (19mm x 60cm) 7/3.15 mm dia G.I. stay wire and strain insulator etc. in cement concrete 1:3 :6 mix foundation including excavation and refilling etc. as required by the department.H.T. stay set complete | 4 | Nos. | |
| 244 | 244 | Supplying and fixing Pole Clamp of M.S. flat 50x6 mm complete as required and directed by the Department. POLE CLAMP | 20 | Nos. | |
| 245 | 245 | Supplying and stringing up of AAA Rabit Conductor in the existing P.S.C./ M.S. /Galvanized pole with binding etc. as required and directed by the Department.AAA Rabit Conductor | 360 | Rm | |
| 246 | 246 | Supplying and fittinf, fixing of galvanized L.T-T cross Arm with clamps, bolts, nuts etc. as required and directed by the Department. galvanized L.T-T cross Arm | 10 | Nos. | |
| 247 | 247 | Supplying and erection of L.T. Pin Insulator with G.I.pin complete with bolts and nuts coach screw etc. as required and as required and directed by the Department. L.T. Pin Insulator | 8 | Nos. | |
| 248 | 248 | Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed.c) M. S. bolts & nuts | 50 | Kg | |
| 249 | 249 | Supplying including installation of 11 KV CT/PT combine metering system complete as required and directed by the Department.(Or as per APDCL) CT/PT combine metering system | 2 | Nos. | |
| 250 | 250 | Supplying with fitting and fixing panel mounting open execution 50KA 415V 50Hz 4P MCCB (Ics=Icu, adustable Ir setting 0.5-1, neutral adjustable with earth fault protection and with rotary handle) (without enclosure) of the following capacity complete with making necessary connection as specified and directed by the deptt.- 50KA 415V 50Hz 4P MCCB ( Make- Schneider, Legrand, Siemens, Hager) 50KA 415V 50Hz 4P MCCB | 2 | Nos. | |
| 251 | 251 | Supplying including installation of 100 mm dia C.I. Earth Pipe complete as required and directed by the Department. 100 mm dia C.I. Earth Pipe | 7 | Nos. | |
| 252 | 252 | Supplying and fitting, fixing of H.T. Danger Plate as required and directed by the Department.100 mm dia C.I. Earth Pipe | 4 | Nos. | |
| 253 | 253 | Supplying including fitting & fixing of P.G Clamp for Rabbit conductor as required and directed by the Department.P.G Clamp for Rabbit conductor | 16 | Nos. | |
| 254 | 254 | Extra for using salt (5 kg) and Charcoal (64 kg} for pipe earth station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the department. salt and Charcoal \n | 7 | Nos. | |
| 255 | 255 | Supplying , fitting & fixing of three phase energy meter as required and directed by the Department. Three phase energy | 1 | Nos. | |
| 256 | 256 | (Supplying , fitting & fixing of metering cabinate as required and directed by the Department.metering cabinate | 2 | Nos. | |
| 257 | 257 | Supplying , fitting & fixing of three phase LT/CT Trivector energy meter as required and directed by the Department.LT/CT Trivector energy meter | 1 | Nos. | |
| 258 | 258 | Supplying , fitting & fixing of bio-metalic aluminium lugs (Assorted) as required and directed by the Department.bio-metalic aluminium lugs-Assorted | 24 | Nos. | |
| 259 | 259 | Providing and laying 6 SWG., G.I earth wire (below GL) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the Department.6 SWG., G.I earth wire | 80 | Rm | |
| 260 | 260 | Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laidup,PVC tape inner sheathed,Unarmoured/ Armour (Galvanised for cables upto 10x1.5 sqmm. 8x2.5 sqmm. 2x 10 sq mm. 3x10 sqmm. 4x6sqmm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/ 1100V grade as per IS7098 (Part1)1988, U.G.cable laid in ground/ partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil,debriset to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/ CCI/ Polycab/Gloster /Finolex make)- 70.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe . | 40 | Rm | |
| 261 | 261 | Supplying and making end termination with Double compression brass gland with Nickel plated lugs for following size of PVC insulated and PVC sheathed / XLPE Al conductor cable of 1.1 KV grade as required.- Flame poof(CBF)-Size70 size:2.5-78,3-1/4\" | 12 | Nos. | |
| 262 | 262 | Supplying including fitting & fixing of P.G Clamp for Rabbit conductor as required and directed by the Department. | 16 | Nos. | |
| 263 | 263 | Providing barbed wire on the existing barbed wire fencing with seven strands of barbed wire 12 S.W. G.x 2pliesx 4 points at 75mm apart including supplying, fitting and fixing with galvanised staples 38mm x 38mm x 3mm sizes with existing posts of the fencing, including removing rotten barbed wire as directed, complete with strengthening of post and tightening of the old barbed wire and joinining old serviceable pieces on remaining lines as and where necessary and as directed. | 40 | Rm | |
| 264 | 264 | Supplying and laying of HDPE pipe/duct IS-4984:1995 as required in the existing trench, through micro tunnelling as directed and specified by the Department.- 90 mm PE63 GRADE PN10 | 20 | Rm | |
| 265 | 265 | Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch(IP-20 protection) in powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the Department.- C&S, Havells, Indo Asian, HPL, GECO make-100 A Four Pole 415V Front handle operated On Load Change over switch | 1 | Nos. | |
| 266 | 266 | Load security and supervision charge payable to APDCL as required and directed by the Department. 50KW load | 50 | KW | |
| 267 | 267 | I) INTERNAL ELECTRIFICATION AT TREATEMENT PLANT | |||
| 268 | 268 | Wiring for light/fan / call bell point with 2x 1.5 sq. mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Kebel/Finolex/Havells or equivalent Make as approved by the deptt) with flat 19 mm ISI marked casing 'n'capping (AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) in surface system, including 6 Amp flush type switch /bell push (Anchor Penta/Gold Medal/Kolor Kany.com/ Havells oe equivalent Make as approved by the deptt) , GI/MS switch board (ISI Marked) half conceale on wall with phenolic laminated sheet cover, Ceiling rose (Anchor/Gold Medal/Kolor Kany.com/ Havells oe equivalent Make as approved by the deptt) etc. complete as directed and as specified by the deptt.\n | |||
| 269 | 269 | a) Short point upto 3.00 metre length | 8 | point | |
| 270 | 270 | b) Medium point upto 6.00 metre length | 8 | point | |
| 271 | 271 | c) Long point upto 10.00 metre length. | 12 | point | |
| 272 | 272 | Supplying and fixing 18 S.W.G. sheet metal boxes of following nominal size in surface wiring system fitted with suitable size phenolic laminated sheet covers in front face of the boxes including painting etc. as require and as specified by the department | |||
| 273 | 273 | 200 mm. x 250 mm. X 60 mm. deep. (Nominal size) | 2 | Nos. | |
| 274 | 274 | 250 mm. x 350 mm. x 60 mm. deep. (Nominal size) | 4 | Nos. | |
| 275 | 275 | Supplying and fixing of switch/socket on the existing board including connections etc. complete. (I.S.I. approved) | |||
| 276 | 276 | 6 Amps flush type switch (one way) | 20 | Each | |
| 277 | 277 | 16 Amps flush type switch. | 2 | Each | |
| 278 | 278 | 3 Pin 6 Amps flush type socket outlets | 4 | Each | |
| 279 | 279 | 3 Pin 16 Amps flush type socket outlets. | 2 | Each | |
| 280 | 280 | 5 Pin 16 Amps flush type multi switch and socket outlets combined unit. | 2 | Each | |
| 281 | 281 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Cable/ Finolex or equivalent Make as approved by the deptt.) in surface flat ISI marked casing 'n' capping (AKG /Precision/Presto Plast/ Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity- | |||
| 282 | 282 | With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm in flat 19 mm ISI marked casing 'n' capping system. | 120 | Rm | |
| 283 | 283 | With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in flat 19 mm ISI marked casing 'n'capping system. | 100 | Rm | |
| 284 | 284 | Supplying with fitting fixing of CFL/Flourescent luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection as approved by the deptt, with 1.5 sq. mm PVC insulated single core copper conductor as reqd. and as directed by the Deptt. Striplite luminaries complete with VPIT copper ballast/electronic balast and decorative end cap and 1 X36/ 40 watt. Flourescent tube. (Crompton Greaves make), Model- DSG1114LDB CROM GOLD/ DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD /DSG 1414 EB PLANET GOLD WITH super saver/super Brite lamp or equivalent ( equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO / HAVELS/ HPL/ SOLAR /JAQUAR MAKE. | 12 | Nos | |
| 285 | 285 | Supplying, installation, testing and commissioning of following outdoor flood light of LED/MH/HPSV luminaries complete with all accessories such as ballast, capacitor, lamp, ignitor and driver as required complete with necessory support /foundation with 2.5 sqmm PVC insulated single core copper conductor as reqd. and as directed by the Deptt.-- MVC 502 1 xMHNTD-150W Philips make flood light luminaries with cast Aluminium housing and toughened glass cover including seperate CG box or equivalent ( equivalent will be selected by the deptt considering the mother items rate) BAJAJ/ WIPRO / HAVELS/ Crompton / HPL/ SOLAR/ JAQUAR MAKE. | 5 | Nos | |
| 286 | 286 | Supplying including installation, commissioning of vermin and dust proof totally enclosed Phosphetised powder painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.95 M(B) x 1.20 M (H) x 0.40M (0) made of 16 SWG (1.66 MM) thick C.R. sheet and 40mm x40mmx 5 mm size angle having 4 Nos. legs at the bottom. The panal Board is to be erected in 1:3:6 PCC foundation including brick soling/grouting etc. complete neatly wiring done with provision for one no 800 A, 4 pole MCCB or switch fuse unit as incomer and provision for 4 Nos DP or TPN outgoing as specified and as directed by the department conforming to IP-43 protection comprising of the following electrical items:\n1) 50mm x 10mm 4 strip copper Bus-Bar 1.20 M length each-4 set\n2) 20mm x 3mm 4 strip copper Bus-Bar 0.50 M length each-4 set\n3. Digital 3 phase Voltmeter Accuracy class 0.50- 1 Nos\n4. Digital 3 phase Ammeter Accuracy class 0.50- 1 Nos\n5. Pilot Lamp with integral Circuit LED 110-230 V (Red, Yellow & Blue)- 3 Nos.\n6. Voltmeter & Ammeter Selector Switch-2 Nos.\n7. 2A Slide fuse unit- 3 Nos\n(Outgoing Switch Gear of reqd. rating will be measured and paid separately )\n | 1 | Nos | |
| 287 | 287 | Supplying with fitting and fixing panel mounting open execution 50KA 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu), adjustable Overload and short Circuit setting , without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. [ABB/ Schneider,/ Legrand/ L&T, Siemens/ Hager C&S Make)- 100 A. ( For 3 Nos 40HP RWPS and one for transformer site= 4 Nos) | 4 | Nos | |
| 288 | 288 | Supplying with fitting and fixing 4P, 10 KA 415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt.- C series [ABB, Schneider MG, Legrand, Hagger, Crabtree Xpro make]- 6 to 32 A ( For Vaccum pump and lighting the internal & external area-4 Nos) | 4 | Nos | |
| 289 | 289 | Supplying of vacuum pump starter for 3HP (DOL) | 2 | Nos | |
| 290 | 290 | Supplying with fitting and fixing including necessary connection as approved by the department D.O.L Starter (Cromton Greaves/ Control and switch gear/ BCH/L&T/ Siemens Make) of following type and capacity as specified and directed by the deptt. D.O.L starter-25HP, 24 to 39A (2 Nos for CWP & 1 standby) | 3 | Nos | |
| 291 | 291 | Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, unarmoured/ Armoured (Aluminium for single core upto 70 sq mm balance aluminium strip), Galvanised for cables upto 2x10 sqmm, 3x10 sqmm,4x6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650 /1100 V grade as per IS:7908 (Part-1) 1988 laid in air or through existing cable trench /duct /cable tray / HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the depertment (Nicco/ Havells/ RPG/CCI/ Polycab/Gloster / Finolex make or equivalent)- | |||
| 292 | 292 | 4 mm2 3 core armoured Cable (panel to external light post 8 nos x 20m av length ) | 130 | Mtr | |
| 293 | 293 | a) 6mm2 3 core armoured Cable (panel to Vaccum pumps) | 18 | Mtr | |
| 294 | 294 | b) 50.00 mm2 3&1/2 core armoured Cable (panel to 2 Nos of starter for Clear water pumps) | 56 | Rm | |
| 295 | 295 | c) 95 Sq.mm 3 and 1/2 core armoured cable (transformer to Panel Board- 150 Rm) | 130 | Rm | |
| 296 | 296 | Supply with installation & commissioning of readymade maintenancefree CPRI approved chemical earthing system with 50MM dia. .00 Metres length corrossion free dualpipe technology G.I. CHEM ROD EELECTRODE complete with RESLOW Grounding Minerals (25KG) and Advance Earth Pit cover (PVC) including excavation of earthpit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt. | 2 | Nos | |
| 297 | 297 | Supplying and laying of 25x6 mm size G.I. strips drawn of surface from earth electrode to Electrical switch gears, machineries etc. complete with supply of G.I. nuts & bolts, screws etc complete etc. including riveting, soldering & making necessary connection as approved, specified and directed by the department. | 40 | Rm | |
| 298 | 298 | Supplying with fitting and fixing of the following integral type street light luminaries complete and consisting of single piece integral opexy gray powder coated dia cast alluminium housing gasket, pot optic reflector, cast alluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp holder, Balast, lamp etc. in the existing pole including making necessary connection as approved by the deptt. with 2 x 2.50 sq mm F.R multi stand and P.V.C insulated single core copper cable as specified and directed by the department.= Philips make Cat. No-SRP 308 1XSON 70W FG for lamp SON70W /cROMPTON GREAVES make-SSSG12071H/FG FOR LAMP 1X70W HPSV/ HAVELS MAKE-LHRS13170A99 FOR LAMP1X70W SON -E | 12 | Nos | |
| 299 | 299 | Supplying including fitting fixing of high speed A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections etc. as required complete and as directed by the Department [Without regulator].- Standard model 1200mm sweep (Usha make) | 6 | Nos | |
| 300 | 300 | Supplying including fitting fixing of Electronic STEP Type Regulator for ceiling fan complete with all connections in the existing board as required complete and as directed by the department. | 6 | Nos | |
| 301 | 301 | J)ESTIMATE FOR SUBMERSIBLE AND CENTRIFUGAL PUMPING SETS | |||
| 302 | 302 | Supply, installation, testing and commissioning of electrical driven Submersible Raw water pumping set (couple type) suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/delta/star as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect (excluding rising delivery pipes and specials fitting, fixing & testing etc.).Discharge 32.16 LPS, Head 45 M , Length of Raw Water Pumping Main=1500.M)\nSupplying and fixing required size of copper cable ( branded ) for power line from pane board to starter and starter to motors as per specifications of the above mentioned pumping sets. 70.00 sqrm\nSupplying, placing, laying, fitting and fixing of suction / delivery of 100 mm dia G.I pipes (TATA, Medium) along with its accessories/specials etc. as per requirement in the field for the above mentioned pumping set as per specifications.\n | 60 | HP | |
| 303 | 303 | Supply, installation, testing and commissioning of electrical driven Centrifugal clear water pumping set (couple type) suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/delta/star complete set as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as base frame, coupling, guard foundation, bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect including construction of foundation all complete including suction and delivery mains/pipes, specials, fitting, fixing etc..\nSpecification:\nHorizontal split casing centrifugal pump type\nRPM of Motors be 1400 to 1500\nConstruction materials – cast iron casing, stainless steel shaft, Bronze impeller.\nHead -35 .00 M\nRPM -1400 to 1500 \nDischarge -32.64 LPS\nCasing -Cast Iron\nShaft -Stainless steel\nImpeller -Bronze Iron\nLength of clear water Pumping Main -100.00M\n | 65 | HP | |
| 304 | 304 | K) Road restoration Work | |||
| 305 | 305 | Construction of granular sub-base by providing coarse graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place methof with rotavator at MC, and compacting with vibratory roller to achieve the desired density , complete as per cl.401 (with an initial lead of 5 km.) | |||
| 306 | 306 | 100 mm dia --3280 meter | 262.4 | Cum | |
| 307 | 307 | 150 mm dia --1440 meter | 122.4 | Cum | |
| 308 | 308 | 200 mm dia --289.60 meter | 26.05 | Cum | |
| 309 | 309 | 250 mm dia -841.60 meter | 79.95 | Cum | |
| 310 | 310 | 300 mm dia --1008.80 meter | 100.88 | Cum | |
| 311 | 311 | Providing laying ,spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with vibratory roller 8 to 10 tonnes instag3es to proper grade and camper ,applying and brooming requisite type of binding material to fill up the interstices’ of coarse aggregate watering and compacting to the required (with an initial lead of 5.0 km)WBM Gr. II | |||
| 312 | 312 | 100 mm dia --3280 meter | 196.8 | Cum | |
| 313 | 313 | 150 mm dia --1440 meter | 91.8 | Cum | |
| 314 | 314 | 200 mm dia --289.60 meter | 19.55 | Cum | |
| 315 | 315 | 250 mm dia -841.60 meter | 59.96 | Cum | |
| 316 | 316 | 300 mm dia --1008.80 meter | 75.66 | Cum | |
| 317 | 317 | Providing laying ,spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with vibratory roller 8 to 10 tonnes instag3es to proper grade and camper ,applying and brooming requisite type of binding material to fill up the interstices’ of coarse aggregate watering and compacting to the required (with an initial lead of 5.0 km)WBM Gr. III | |||
| 318 | 318 | 100 mm dia --3280 meter | 196.8 | Cum | |
| 319 | 319 | 150 mm dia --1440 meter | 91.8 | Cum | |
| 320 | 320 | 200 mm dia --289.60 meter | 19.55 | Cum | |
| 321 | 321 | 250 mm dia -841.60 meter | 59.96 | Cum | |
| 322 | 322 | 300 mm dia --1008.80 meter | 75.66 | Cum | |
| 323 | 323 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical with the bitumen emulsion CSS-1h. | |||
| 324 | 324 | 100 mm dia --3280 meter | 196.8 | Cum | |
| 325 | 325 | 150 mm dia --1440 meter | 91.8 | Cum | |
| 326 | 326 | 200 mm dia --289.60 meter | 19.55 | Cum | |
| 327 | 327 | 250 mm dia -841.60 meter | 59.96 | Cum | |
| 328 | 328 | 300 mm dia --1008.80 meter | 75.66 | Cum | |
| 329 | 329 | Open graded premix surfacing /Mixed seal surfacing (Mechanical means using HMP of capacity not less than 75 tonnes/hour. Providing, laying and rolling of open graded premix surfacing of 20 mm thickness composed of 13.2mm to 5.6 mm aggregates either using penetration grade bitumen (60/70 grade) or bitumen emulsion to required line, grade and level to serve as wearing coarse on a previously prepared base, including mixing in a suitable plant laying and rolling with a smooth wheeled roller 8-10 T capacity to the road level and grade.(Including carriage up to initial lead of 5.0 km from quarry and carriage of mixed materials up to 10.0 km initial lead from mixing plant) ( Including cost of testing of materials at site and laboratory as directed by the deptt.) | |||
| 330 | 330 | 100 mm dia --3280 meter | 196.8 | Cum | |
| 331 | 331 | 150 mm dia --1440 meter | 91.8 | Cum | |
| 332 | 332 | 200 mm dia --289.60 meter | 19.55 | Cum | |
| 333 | 333 | 250 mm dia -841.60 meter | 59.96 | Cum | |
| 334 | 334 | 300 mm dia --1008.80 meter | 75.66 | Cum | |
| 335 | 335 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats.) (Including carriage up to initial lead of 5.0 km from quarry) (Including cost of testing of materials at site and laboratory as directed by the deptt.) | |||
| 336 | 336 | 100 mm dia --3280 meter | 196.8 | Cum | |
| 337 | 337 | 150 mm dia --1440 meter | 91.8 | Cum | |
| 338 | 338 | 200 mm dia --289.60 meter | 19.55 | Cum | |
| 339 | 339 | 250 mm dia -841.60 meter | 59.96 | Cum | |
| 340 | 340 | 300 mm dia --1008.80 meter | 75.66 | Cum | |
| 341 | 341 | L) DEVELOPMENT OF TWO NOS DEEP TUBE WELLS | |||
| 342 | 342 | Transportation of air compressor from the Divisional Head Quarter to the drilling site with all accessories including cost of P.O.L. all complete as directed.Upto 100.00 Km distance from Divisional H.Q | 60 | Per Km | |
| 343 | 343 | Transportation of P.O.L. all complete as directed | 30 | Litre | |
| 344 | 344 | Construction of temporary accommodation and low cost sanitary facility for drilling staff including cost of camp materials viz. cots, tables, chairs, utensils, dresses, safety helmets etc. and dismantling the accommodation after completion of the work all complete as directed. | 1 | job | |
| 345 | 345 | Developing of the D.T.W. with air compressor,( For 2 nos Deep Tube Well -- 60 hours x 2 nos ) | 120 | hour |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy