Water Resources and Irrigation Government Departments Closing in 0 days TDR #24986475

Augmentation Of Dergaon Water Supply Scheme Execution , Testing And Commissioning Of 2 . 35 Mld Capacity Treatment Plant , Distribution , Raw Water Pumping Main , Submersible , Centrifugal Pumping Sets , Electrical Internal , External And Drawing

Issued by Government Departments · , Assam
Tender Value
3.62 Crore
Estimated cost
Bid Submission
03 Aug 2020
0 days left
EMD
7.24 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Augmentation Of Dergaon Water Supply Scheme Execution , Testing And Commissioning Of 2 . 35 Mld Capacity Treatment Plant , Distribution , Raw Water Pumping Main , Submersible , Centrifugal Pumping Sets , Electrical Internal , External And Drawing Power Line , Sub Stations , Development Deep Tube Wells

BOQ

Name of Work :Augmentation of Dergoan Water Supply Scheme
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11A) Construction of Aerator , Raw water channel, Filter house and Mechanical piping works
22Earth work in excavation fin foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing , ramming , watering etc. and removal of surplus earth with 50 mtr lead and lift upto 1.5 mtr all complete as directed-(a) Ordinary soil250.99Cum
33(B) Extra over item no 1.00 above for each 1.00 mtr depth or pert thereof beyomd the initial depth of 2.00 mtr8Cum
44Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered) -A) Up to a depth of 1.5 meter.354.25Sqm
55B) From depth of 1.5 meter to 3.00 meter.96.45Sqm
66Supplying and filling sand gravel in foundation, trenches of column footings over slushy soil including local carriage of materials within 8.00 Km pumping out water, ramming etc complete for strengthening the bearing capacity of the soil as directed and specified including payment of land compensation, forest loyalty, sale tax and other duties and taxes as may be necessary.12Cum
77(B)Extra lead per Km truck carriage for sand gravel beyond the initial lead of 8 km.( Quarry distance from site is 45 Km; So additional lead is 45-8= 37.00 Km444.15Cum/km
88Sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc complete as directed and specified including payment of land compensation, forest loyalty, sale tax and other duties and taxes as may be necessary.--(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.68.13Cum
99Providing Brick soling in foundation and floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade etc, if necessary dewatering complete- Brick on flat soling.222.4Sqm
1010Providing & laying 25 mm thick Damp Proof Coarse with cement concrete in prop.1:1.5:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.2.42Sqm
1111Plain Cement concrete works with coarse aggregate of sizes 13 mm to 32 mm in foundation bed for footing,steps,walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately -In proportion 1:3:620.27Cum
1212Providing and laying controlled cement concrete of grade M 30 with 20 mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost form work and reinforcement for R.C.C. work as directed in sub structures up to plinth level -for foundation, footing ,column with base, tie and plinth beams....etc
1313a)In sub-structure- Foundation, footing, tie beam and the like upto plinth level.45.56Cum
1414b)In super structure-Lintel, chajja,column, beams, slab , staire case etc upto first floor level.103.55Cum
1515Providing and laying controlled cement concrete of grade-M25 with 20 mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost form work and reinforcement for R.C.C. work a) In sub-structure- Foundation, footing, tie beam and the like upto plinth level.10.42Cum
1616Extra for providing and mixing normal Plastisizer Plastiment BV 40 of Sika India Ltd. /Dr. Sealkit Superplast WR 40 (Asian Chemicals)/Rheobuild 1100i of BASF@ 0.5%-0.8% by weight of cement in concrete for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. as specified and directed by the Department complete at all levels.(iii) In 1 : 1 : 2 (1cement : 1coarse sand : 2aggregate) or M-25 grade.101.35Cum
1717Extra for RCC works in each subsequent floor or part thereof above 1st floorlevel.48.29Cum
1818Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S code for RCC work/ RB walling including straightening , cleaning , cutting and bending to proper shapes and lengths per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, support, chairs, spacers complete ( up to 1st floor level- a) From Primary Producer: TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel /RINL- (ii)Super Ductile (SD) TMT reinforcement bars20952.8Kg
1919B) Extra for reinforcement work above first floor level6259.3Kg
2020Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the same for insitu reinforced concrete and plain concrete works in : (a) In foundation etc57.05Sqm
2121b) C/S of tie beam, etc139.17Sqm
2222c) C/S of square column312.29Sqm
2323d) Sides and soffits of beam161.07Sqm
2424e) Flat surface-suspended floors, roofs, landings216.91Sqm
2525f) Stair case with sloping soffits50.92Sqm
2626g) In super structure- In vertical wall421.08Sqm
2727d) In suspended floor, slab, landing,etc30.34Sqm
2828Extra for centering and shuttering for each subsequent floor or part thereof above first floor level.158.35Sqm
2929Extra for centering and shuttering for each subsequent floor or part thereof above first floor level mentioned in item no21375.14Sqm
3030Brick work in cement mortar with first class bricks including racking out joints and dewatering if necessary and curing complete as directed in sub structures up to plinth level with 1:3 mix mortar.26.59Cum
3131112 mm thick reinforced brick wall in proportion 1:5, reinforced with two lines of M.S. rod/ tor steel as specified embedded in 38mm thick concrete course in proportion 1:2:4 with coarse aggregate 12 mm down at every fourth courses embedded with protruding rod as directed (M.S.rod/Tor steel shall be measured and paidseperately) in super structures above plinth up to 1st floor level.235.93Sqm
3232Extra for brick walling for each subsequent floor or part thereof above first floor level as mentioned in item nos.32209.07Sqm
3333Providing wood work in frames (chowkhat) of doors, windows, clearstory windows and other similar works in fixed in position in contact with C.C.or brick masonry wall including supplying , fitting and fixing with and M.S. hold fast (40mm X 3mm X 250) as per design embedded in cement concrete block in proportion 1:2:4 and with 2 coats of kiricide oiling to the timber faces in contact with CC and masonry as directed and specified.(a) With 1st class timber (Sundi /Bonsum)0.131Cum
3434Providing, fitting and fixing steel window (openable ) of standard rolled steel sections as per relevant IS code -1038 joints mitred and welded with 15 mm X 3 mm X 100 mm lug embedded in cement concrete block of M-10 ( 1:3:6) grade including providing and fixing of projecting hinges( not more than 65mm and not less than 15 mm wide) bolting device and steel handles, peg stays of 300 mm long each complete including providing 12 mm X 12mm square bar duly welded to steel frame at not more 120 mm centre to center, applying a priming coat of red lead paint etc. complete as per drawing Openable shutter18.56Sqm
3535Providing and fixing clear sheet glass bedded in putty and fixed with / without wooden beadings including necessary cuttings of glass to required sizes (payment for wooden beads shall be made seperately). -5 mm thick.17.29Sqm
3636Providing, fitting and fixing 35mm thick full paneled doors/windows including oxidized M.S. butt hinges(100 mmX 75 mmX 3.55 mm) 6 nos. with necessary screws.- 35 mm thick shutter with 1st class Bola/ Gamari wood.3.59Sqm
3737Supplying , fitting and fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodized to bright natural matt & satin finished.
3838a) Sliding door bolts of size-250 mmX 16 mm2Each
3939b)Tower bolt-250mm X 12 mm4Each
4040c) Door/ handle-150 mm size4Each
414125 mm thick cement concrete topping 1:2:4 (1 cement: 2 coarse sand :4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish ( base concrete to be measured and paid separately) to be laid in panels including curing complete as directed.346.34Sqm
4242Cement plaster skirting with cement mortar in proportion 1:3 (1 cement :3 coarse sand) finished with floating coat of neat cement including rounding of junction with floor- 20 mm thick431.61Sqm
434315 mm plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed-In cement mortar 1:6.766.85Sqm
444410mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed.- In cement mortar 1:3310.05Sqm
4545Extra for plastering on ceiling and soffits of stairs up to first floor level ( instead of plastering on walls) including curing complete as directed. - In single coat plaster310.05Sqm
4646Extra for interior plastering above first floor level for every additional floor or part thereof including curing complete as directed. - In single coat plaster377.32Sqm
4747Extra for exterior plastering over wall up to a height of first floor level above G.L. including curing complete as directed. - In single coat plaster310.05Sqm
4848Extra for exterior plastering for wall for every additional floor or part thereof beyond first floor level including curing complete as directed. - In single coat plaster275.19Sqm
4949White washing with lime on wall surfaces (two coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt, dust, mortar drops and other foreign matter and including preparing the surface even and sand papered smooth.292.47Sqm
5050Supplying, fitting,and fixing M.S. angles, M.S. flats, bolts and nuts including painting with red lead paint one coat complete as directed- M.S. angles, pipes etc190.8Kg
5151Applying one coat cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.831.04Sqm
5252Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface( two coats) to give an even shade after thoroughly brooming the surfaces to remove all dirt and remains of all loose powdered materials.831.04Sqm
5353Finishing old / new with waterproffing weather coat smooth antifungal exterior painting of approved make of Berger paint of required shade after cleaning the surface etc.including scaffolding complete as directed at all levels ( two coats)5.19Sqm
5454Painting two coats (excluding priming coat) over new wood and wood based surfaces over 100 mm in girth/ width with enamal paint of approved brand and manufacture ( Asian paint/ Berger Paint / ICI paint / J&N paint / Nerolac ) to give an even shade including preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting .5.19Sqm
5555Applying prime coat over new steel and other metal surfaces over 100 mm in girth/ width after preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matterand scoured with wire brushes, fine steels, wood scrapers and sand papering- with ready mixed \" Red lead / Red oxide primer.43.4Sqm
5656Painting two coats ( excluding priming coat) over new steel and other metal surfaces over 100 mm in girth/ width with enamel paint of approved brand and manufacture (Asian paint / Berger paint / ICI paint / J&N paint / Nerolac ) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter.43.4Sqm
5757Applying 2 coats of 1mm thick elastomeric cementitious waterproofing coating Brushbond RFX of Fosroc Chemicals /Dr. Sealkit Flexbond AP 122 C (Asian Chemicals) / MASTERSEAL 550EL of BASF for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. after proper surface preparation and soaking the surface with water prior to application complete as specified and directed by the Department at all levels.209.82Sqm
5858B)MACHNICAL ARRANGEMENT FOR TREATEMENT PLANT
5959Labour charge for carrying laying in position cast iron double flanged pipe in line level all complete as directed
606080mm dia pipe78Rm
6161250mm dia pipe79.2Rm
6262Providing flanged foints to double flanged CI pipes and specials with testing of joints and including supplying bolts, nuts and 3mm thick rubber insertion sheet all complete as directed
636380mm dia.20Each
6464250mm dia.75Each
6565Labour charge for carrying, placing in position, fitting and fixing CI sluice valve ( with wheel and cap) CI reflex valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. ( the tail pieces if required will be paid seperately) all complete as directed ( one valve and two flanged joints).
666680mm dia.2Each
6767150mm dia4Each
6868200mm dia.2Each
6969250mm dia.8Each
7070300mm dia.2Each
7171Labour charge for carrying and laying in position D.I. / C.I.S.& S S&S , flange , Plain ended C.I. specials such as Tee , Bends , Collars , Tappers and Caps etc complete as directed .15Qntl.
7272Providing 12mm dia.hole for lateral @ 215mm center to center spacing700Each
7373Providing Pipe for areator arrangment 65mm dia.GI medium pipe including making of Round shape suitable for the existing size and making hole for areation all complete including tee, bend etc1Job
7474Supplying of centrifugally cast(spun) iron double flange pressure pipes conforming to ISI specification in standard working length .
757580mm dia.390Kg
7676250mm dia.6541.92Kg
7777Supplying and devilary of cast iron double flanged (CI/DF) sluice valve with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest ammendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified.
787880mm dia2Each
7979150mm dia.4Each
8080200mm dia.8Each
8181250mm dia.2Each
8282300mm dia.2Each
8383Supplying and devilary of ISI marked DI double socketed fittings such as Tee , Bends , Reducer , Tappers and Caps etc class k-12 conforming to IS 9523-2000 of PN 1.6 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 DI pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-19851500Kg
8484Supply of Galvanized Iron(GI) Pipe as per the IS specification conforming to IS-1239(pt-I), 1990 medium pipe of 100 mm dia for Air Blower line22Rm
8585Supply of Galvanized Iron(GI) for Air blower line ( heavy duty) as per the IS specification conforming to IS-1239(pt-I), 1990
8686100mm dia. Tee2Each
8787100mm dia. Union socket2Each
8888100mm dia. Elbow8Each
8989100mm dia.900 bend4Each
9090100 mm dia. Socket8Each
9191100mm dia. 6'' nipple6Each
9292100mm dia full way valve.2Each
9393Supply of full Thread Nuts & Bolt suitable for DI pipe fitting and specials170Kg
9494Supply of rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. The PCD and flange hole dimension should conform to IS 1538/1993 and gasket should be suitable for making flanged joint.100Kg
9595Supply of Galvanized Iron(GI) Pipe as per the IS specification conforming to IS-1239(pt-I), 1990 medium pipe of 15mm dia for Alum & Bleaching dozer80Rm
9696Supply, installation, testing and commissioning of 20 HP capacity of electrical driven Air blower suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/delta/star complete set as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as base frame, coupling, guard foundation, bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect including construction of foundation all complete including connection with Air Blower line in all respect.20Each
9797C) Providing Filter Media (Filter bed size- 2x3.00 m x 3.95 m)
9898Supplying and placing of River gravel for Rapid Gravity filter effective size following sixe and free from dust, clay, fine particles and dirt of every description.\n40 to 50 mm size : 200mm \n32 to 40 mm size : 100mm\n12 to 20 mm size : 100mm\n6 to 12 mm size: 100mm\n11.85Cum
9999Supplying and placing of coarse sand filter for Rapid Gravity filter effective size 0.06mm to 0.50 mm and uniformity coefficient between 1.7 to 1.3 all complete as directed sand shall be hard and quartz and quartzite and free from dust, clay, fine particles and dirt of every description.21.33Cum
100100D) Distribution pipe net work
101101Earth work in excavation in black toping road surface (average thickness of black toping 35mm) including the removal of road metal, boulders and refilling the same properly and restore the road surface to its original condition (except black toping as the black toping to be done by the PWD on necessary payment all complete as directed.For 100mm dia to 300 mm dia DI pipe2532M2
102102Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders and including restoration of road surface original condition all complete as directed.For 100mm dia to 300 mm dia DI pipe3376M2
103103Earth in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50 M lead and lift up to 1.5 M all complete as directed including boiling out water where necessary.b) Bastic land, tillah soil, hard soil, mixed with moram gravel and boulder up to one man size.For 100mm dia to 300 mm dia DI pipe.48.5M3
104104Labour charge for carrying and laying DI pipes and specials (Class-7) in position, in line and level complete as directed.
105105100 mm dia. pipe4100RM
106106150 mm dia. pipe1800RM
107107200 mm dia. pipe362RM
108108250 mm dia. pipe1025RM
109109300mm dia. pipe1261RM
110110Providing rubber gasket joints to C.I. pipes and specials with testing of joints including carriage of the materials but excluding the cost of rubber gasket all complete as directed.
111111100 mm dia. pipe820Each
112112150 mm dia. pipe360Each
113113200 mm dia. pipe73Each
114114250 mm dia. pipe205Each
115115300mm dia. pipe252Each
116116Labour charge for carrying, placing in position S & S flanged, plain ended C.I Specials such as tees, bends, collars, tappers and caps etc all complete as directed.A) Al Socketed Tee, Tee, all type of Bend, Reducer, Flange adoptor etc83.25Qntl.
117117Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxe valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints
118118100 mm dia. pipe6Each
119119150 mm dia. pipe3Each
120120200 mm dia. pipe2Each
121121250 mm dia. pipe2Each
122122300mm dia. pipe1Each
123123Labour Charge carrying, fitting and fixing CI Double Air valve complete with supplying bolts, Nuts, 3mm thick rubber incertation etc. All complete as directed
12412480 mm dia.5Each
12512565 mm dia.3Each
126126Labour charge for cutting DI pipe of different dia for required length as directed.100Each
127127Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge .
128128a) Size -1000x1000x120014Each
129129b) Size -1200x1200x12014Each
130130Supply, delivery and stacking of centrifugally cast (spun) Ductile Iron Presser Pipes ISI Marked, Class K-7 with socket and spigot ends conforming to IS:8329/2000 of standard working lengths 5.50 meter and 6.00 meter with inside inside cement mortar lining of 3 mm nominal thickness and outside Blue Epoxy coating suitable against longitudinal bending and differential settlement, relatively smooth walls, chemically inert with respect to soil and water.
131131100 mm dia.4100Rm
132132150 mm dia.1800Rm
133133200 mm dia362Rm
134134250 mm dia1025Rm
135135300 mm dia1261Rm
136136Supplying and devilary of ISI marked DI double socketed fittings such as Tee , Bends , Reducer , Tappers and Caps etc class k-12 conforming to IS 9523-2000 of PN 1.6 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 DI pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-19858325kg
137137Supplying and devilary of ISI Marked CI Jeffy Joints Collar (Flanged Adopter) with full threaded Nuts & Bolts for use with DI pipes Conforming to IS:14846/2000 with up to date amendments of following sizes. (PN-1.6)
138138i) 100 mm dia.10Each
139139ii) 150 mm dia.4Each
140140ii) 200 mm dia.6Each
141141ii250 mm dia.4Each
142142ii) 300mm dia.4Each
143143Supplying and devilary of ISI Marked CI Jeffy Joints (Mechanical Collar Coupling) with full threaded Nuts & Bolts for use with DI pipes Conforming to IS:14846/2000 with up to date amendments of following sizes. (PN-1.6)
144144i) 100 mm dia.10Each
145145ii) 150 mm dia.4Each
146146ii) 200 mm dia.6Each
147147ii250 mm dia.4Each
148148ii) 300mm dia.4Each
149149Supplying and devilary of cast iron double flanged (CI/DF) sluice valve with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest ammendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified.
150150100 mm dia. pipe8Each
151151150 mm dia. pipe2Each
152152200 mm dia. pipe4Each
153153250 mm dia. pipe3Each
154154300mm dia. pipe1Each
155155Supplying ,devilary, fitting and fixing of 98.5 mm dia resilient seated Cast Iron Air Relief Valves conforming to IS:14845-2000 to DI water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified.
15615676.63 mm dia.5Each
15715765 mm dia.3Each
158158Supply of full Thread Nuts & Bolt suitable for DI pipe fitting and specials200Kg
159159Supply of rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. The PCD and flange hole dimension should conform to IS 1538/1993 and gasket should be suitable for making flanged joint.100Kg
160160Supplying of additional quantity of rubber ring of EPDM quality (Tyton Joint) as per IS:5382-1985 and its upto date amendment as applicable suitable for DI pipes
161161100 mm dia30Each
162162150 mm dia10Each
163163200 mm dia20Each
164164250 mm dia15Each
165165300 mm dia20Each
166166E) Raw Water Pumping main for 200 mm dia
167167Earth work in excavation in black toping road surface (average thickness of black toping 35mm) including the removal of road metal, boulders and refilling the same properly and restore the road surface to its original condition (except black toping as the black toping to be done by the PWD on necessary payment all complete as directed.160M2
168168Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders and including restoration of road surface original condition all complete as directed.160M2
169169Earth in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50 M lead and lift up to 1.5 M all complete as directed including boiling out water where necessary.b) Bastic land, tillah soil, hard soil, mixed with moram gravel and boulder up to one man size.160M3
170170Labour charge for carrying and laying DI pipes and specials (Class-k-9) in position, in line and level complete as directed.1500RM
171171Providing rubber gasket joints to C.I. pipes and specials with testing of joints including carriage of the materials but excluding the cost of rubber gasket all complete as directed.290Each
172172Labour charge for carrying, placing in position S & S flanged, plain ended C.I Specials such as tees, bends, collars, tappers and caps etc all complete as directed.9.16Qntl.
173173Labour charge for carrying, providing and fixing non return valve of approved quality including supplying jointing materials all complete as directed.1Each
174174Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxe valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints1Each
175175Labour Charge carrying, fitting and fixing CI Double Air valve complete with supplying bolts, Nuts, 3mm thick rubber incertation etc. All complete as directed3Each
176176Labour charge for cutting DI pipe of different dia for required length as directed.25Each
177177Construction of RCC thrust block as per standard design and drawing as directed by the Engineers-In-Charge . Size 1.20 m X 1.20 M x !.20 M8Each
178178Construction of RCC pillar as per standard design and drawing as directed by the Engineers-In-Charge .Size-0.30 m x 0.30 m x 2.50 m6Each
179179Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge . Size- 1.20 m x 1.20 m x1.20 m1Each
180180Supply, Delivery , laying , testing and commissiong Stacking of Centrifugally Cast (Spun) Ductile Iron of 200 mm dia. (Class, K-9) Pressure Pipes ISI Marked with Socket & Spigot ends conforming to IS 8329: 2000 of standard working lengths 5.50 meter or 6.00 meter with inside cement mortar lining of 3 mm nominal thickness and outside Blue Epoxy coating suitable against longitudinal bending and differential settlement, relatively smooth walls, chemically inert with respect to soil and water including DI specials like bend ,tee etc as required for laying of said pipe lines and hydraulic testing of the same, .1500RM
181181Supplying and devilary of ISI marked DI double socketed fittings such as Tee , Bends , Reducer , Tappers and Caps etc class k-12 conforming to IS 9523-2000 of PN 1.6 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 DI pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-1985472Kg
182182Supplying and devilary of ISI Marked CI Jeffy Joints Collar (Flanged Adopter) with full threaded Nuts & Bolts for use with DI pipes Conforming to IS:14846/2000 with up to date amendments of following sizes. (PN-1.6) 200 mm dia6Each
183183Supplying and devilary of resilient seated Ductile Iron Horizontal Non -Return Valves conforming to IS:5312/2004 and PN 1.6 with up to date amendments to DI water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified of 200 mm dia1Each
184184Supplying and devilary of cast iron double flanged (CI/DF) sluice valve 200 mm dia with hand wheel (Class PN-1.6) conforming to relevant BIS Specifications (with latest ammendment, current at the time of execution), of any reputed make to the distribution pipe lines including supply, fitting, fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. and including all taxes and duties, all complete as directed and specified.1Each
185185Supplying ,devilary, fitting and fixing of 98.5 mm dia resilient seated Cast Iron Air Relief Valves conforming to IS:14845-2000 to DI water distribution pipe line including supply, fitting fixing of insertion sheets (gaskets), nuts and bolts with washers, etc. all complete as directed and specified.1Each
186186Supply of full Thread Nuts & Bolt suitable for DI pipe fitting and specials100Kg
187187Supply of rubber gasket 4.00 mm thick in quality and in conform to IS: 5382/1985. The PCD and flange hole dimension should conform to IS 1538/1993 and gasket should be suitable for making flanged joint.70Kg
188188F) Construction of Pump houses
189189Earth work in excavation in slushy/ marshy soil, decomposed organic matter mixed with brickbats, broken glass panes, broken earthen pots etc. removal of stumps and other deleterious matter in the proposed building site including constant water pumping23.2044M3
190190Providing brick soling in foundation and floor with stone / best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade etc, if necessary dewatering complete- Brick on flat soling.56.9M2
191191Sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc complete as directed and specified including payment of land compensation, forest loyalty, sale tax and other duties and taxes as may be necess17.04M3
192192Providing & laying 25 mm thick Damp Proof Coarse with cement concrete in prop.1:1.5:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curi3.02848M2
193193Plain Cement concrete works with coarse aggregate of sizes 13 mm to 32 mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be m4.239M3
194194Providing and laying R.C.C. work in proportion 1:1.5:3 including dewatering if necessary and curing complete but excluding cost form work and reinforcement for R.C.C. work as directed in sub structures up to plinth level -for foundation, footing ,column w
195195a) In sub-structure- Foundation, footing, tie beam and the like upto plinth level.5.58M3
196196b) In super structure-Lintel, chajja, column, beams, slab , stair case etc upto first floor level.10.5035M3
197197Supplying, fitting & fixing in position reinforcements bars conforming to relevant IS Code for R.C.C. work / RB Walling including straightening , cleaning , cutting and bending to proper shape & length as per detail, supplying and binding with 20G anne20Qntl
198198Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the sam8.64M2
199199b) C/s of tie beam11.76M2
200200c) Column, pier, post54M2
201201d) Sides and soffits beam, lintel, horizontal ties.39.984M2
202202e) Flat surface such as soffits of suspended floors, chajjas and the like.50.8528M2
203203Brick work in cement mortar with first class bricks including racking out joints and dewatering if necessary and curing complete as directed in sub structures up to plinth level with 1:5 mix mortar.7.50402M3
204204112 mm thick reinforced brick wall in proportion 1:5, reinforced with two lines of M.S. rod/ tor steel as specified embedded in 38mm thick concrete course in proportion 1:2:4 with coarse aggregate 12 mm down at every fourth courses embedded with protrudin101.452M2
205205Providing wood work in frames (chowkhat) of doors, windows, clearstory windows and other similar works in fixed in position in contact with C.C.or brick masonry wall including supplying , fitting and fixing with and M.S. hold fast (40mm X 3mm X 250) (a) With 1st class timber ( Hollock/Bonsum)0.2352M3
206206Providing, fitting and fixing fully glazed window without intermediate sash bars including oxidised M.S butt hinges (75mm x 60mm x 3.15mm) 2nos.on each leaf and 3 nos. on single leaf (glass panes to be measured and paid separately) W1200X13507.9704M2
207207Providing and fixing clear sheet glass bedded in putty and fixed with / without wooden beadings including necessary cuttings of glass to required sizes (payment for wooden beads shall be made seperately).-5 mm thick. a) Area of glass panes exceeding 0.52 Sqm. W1200X13506.0264M2
208208Providing, fitting and fixing 35mm thick full paneled doors/windows including oxidized M.S. butt hinges(100 mmX 75 mmX 3.55 mm) 6 nos. with necessary screws.- 35 mm thick shutter with 1st class Bola/ Gamari wood.4.2444M2
209209Supplying , fitting and fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete ( anodized
210210a) Sliding door bolts of size-250 mmX 16 mm2Nos.
211211b)Tower bolt- (i) 250mm X 12 mm4Nos.
212212(ii) 100mm X10mm dia tower bolt12Nos.
213213c) Door/ handle- (i) 150 mm size4Nos.
214214(ii) 100 mm size handle for window6Nos.
21521525 mm thick cement concrete topping 1:2:4 (1 cement: 2 coarse sand :4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish ( base concrete to be measured and paid separately) to be laid in panels including curing com77.46M2
216216Cement plaster skirting with cement mortar in proportion 1:3 (1 cement :3 coarse sand) finished with floating coat of neat cement including rounding of junction with floor 20 mm thick29.88M2
21721715 mm plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directe181.36M2
21821810mm thick cement plaster in single coat on fair side of brick/concrete wall for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed.(APW57.396M2
219219Extra for plastering on ceiling and soffits of stairs up to first floor level ( instead of plastering on walls) including curing complete as directed In single coat plaster57.396M2
220220Extra for exterior plastering over wall up to a height of first floor level above G.L. including curing complete as directed In single coat plaster105.6M2
221221White washing with lime on wall surfaces (two coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt, dust, mortar drops and other foreign matter and including preparing the surface even and sand papered smooth.46.02M2
222222Supplying, fitting, and fixing M.S. grills- Plain gerill fixed to wooden frame107.738Kg
223223Applying one coat cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth192.736M2
224224Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface( two coats) to give an even shade after thoroughly brooming the surfaces to remove all dirt and remains of all loose powdered mater192.736M2
225225Applying prime coat over new wood and wood based surfaces over 100 mm in girth/ width after and including preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting with ready mixed white wood D1200X 2100 paneled door and W 1200X135019.584M2
226226Painting two coats (excluding priming coat) over new wood and wood based surfaces over 100 mm in girth/ width with enamel paint of approved brand and manufacture ( Asian paint/ Berger Paint / ICI paint / J&N paint / Nerolac ) to give an even shade include19.584M2
227227Applying prime coat over new steel and other metal surfaces over 100 mm in girth/ width after preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper2.52M2
228228Painting two coats ( excluding priming coat) over new steel and other metal surfaces over 100 mm in girth/ width with enamel paint of approved brand and manufacture (Asian paint / Berger paint / ICI paint / J&n paint / Nerolac ) to give an even shade in2.52M2
229229G)Construction of security Fencing with Gate at Treatment Palnt site
230230Supplying, fitting and fixing galvanised barbed wire fencing with seven strands of barbed wire 12 S. W. G .x 2plies x 4 points at 75mm apart with angle iron intermediate fencing posts not more than 1800mm apart and straining and end post etc. as necessary to be fitted with straining eye bolts and staples etc. complete as directed, specification of the angle iron post as given below. \na) Intermediate post 35mm x35mm x5mm x1800mm long bottom torched and duly slotted.\nb) Straining post 65mm x 65mm x 6mm x 1820mm long with 2 stays of 35mmx35mmx1520mm long and 3 base plates 200mm x 200mm x 5mm, duly slotted to take eye bolts etc.\nc) Corner posts 65mm x 65mm x 6mm x1820mm long with 2 stays of 35mm x 35mm x 5mm x 1 670 mm and 3 base plates 200mm x 200mm x 5mm,duly slotted to take eye bolts etc. \nd) Straining or end posts 65mmx 65mm x 6mmx 1820mm long with 1 stays of 35mm x 35mm x 5mmx 1820 mm long with base plates 200mmx 200mm x 5mm, duly slotted to take eye bolts etc. \n(All the angle iron posts to be embeded 600mm in C.C.pillars of size 300mmx300mmx600mm in prop.1: 3: 6 and one coat of anticorrosive ready mixed painting to all iron works) including excavation of foundation trenches for C.C. blocks and refilling and removal of surplus soil after completion of works.\n280M
231231Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) st3Qtl
232232H)CONSTRUCTION OF ELECTRICAL PROWER LINE DRAWING AND SUBSTATION AT TREATEMENT PLANT AND DEEP TUBEWELL SITE
233233Supplying, installation testing and commissioning of the following rating copper wound indoor/outdoor type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended upto date upto200 KVA starrating upto 5star,above 200 KVA as per CEA guidelines for losses along with (i)63 KVA, 50Hz. 11/0.433KV. Oil filled transformer with Off Circuit tap change.1Nos.
234234(ii) 25 KVA 50Hz. 11/0.433KV. Oil filled transformer with Off Circuit tap change.1Nos.
235235Supplying and erection of PSC pole 7.50 m long the pole, the pole is to be erected in 1:2:4 plain cement concrete foundation of size 1.50m X 0.45m x 0.45m having PCC base foundation 15cmx 60cmx 60cm including edge brick soling and plasttering above GL portion(0.30m) complete with excavation of earth, handling of surplus soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department. PSC pole 7.50 m long6Nos.
236236Supplying including installation of 100 mm dia C.I. Earth Pipe as required and directed by the Department.100 mm dia C.I. Earth Pipe4Nos.
237237Supplying including fitting and fixing G.I Channel X Arm 100X50X6 x2200 mm size as required and directed by the Department, including arrangement of Supervision Certificate from cmpetant authority of APDCL.G.I Channel X Arm 100X50X6 x22002Nos.
238238Supplying including fitting and fixing 11 KV Disc Insulator, 70 KN in the existing MS Channel as required and directed by the Department. 11 KV Disc Insulator, 70 KN10Nos.
239239Supplying including fitting and fixing 11 KV Pin Insulator with pin as required and directed by the Department. 11 KV Pin Insulator10Nos.
240240Supplying and fixing of 11 KV, 400 A Gang Operated Switch with all accessories complete as required and directed by the Department. Gang Operated Switch,2Nos.
241241Supplying and fixing of 11 KV, 150 A D.O. Fuse set complete as required and directed by the Department. 11 KV, 150 A D.O. Fuse set2Nos.
242242Supplying and fixing of 11 KV, 5KA lighting arrestor(Poly) set complete as required and directed by the Department. 11 KV, 5KA lighting arrestor2Nos.
243243Supplying and erection of H.T. stay set complete (Galvanized) with 19mm dia x 1.8m long stay rod, anchor plate of size 30cm x 30cm x 6.4mm, thimble stay clamps, turn buckle (19mm x 60cm) 7/3.15 mm dia G.I. stay wire and strain insulator etc. in cement concrete 1:3 :6 mix foundation including excavation and refilling etc. as required by the department.H.T. stay set complete4Nos.
244244Supplying and fixing Pole Clamp of M.S. flat 50x6 mm complete as required and directed by the Department. POLE CLAMP20Nos.
245245Supplying and stringing up of AAA Rabit Conductor in the existing P.S.C./ M.S. /Galvanized pole with binding etc. as required and directed by the Department.AAA Rabit Conductor360Rm
246246Supplying and fittinf, fixing of galvanized L.T-T cross Arm with clamps, bolts, nuts etc. as required and directed by the Department. galvanized L.T-T cross Arm10Nos.
247247Supplying and erection of L.T. Pin Insulator with G.I.pin complete with bolts and nuts coach screw etc. as required and as required and directed by the Department. L.T. Pin Insulator8Nos.
248248Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed.c) M. S. bolts & nuts50Kg
249249Supplying including installation of 11 KV CT/PT combine metering system complete as required and directed by the Department.(Or as per APDCL) CT/PT combine metering system2Nos.
250250Supplying with fitting and fixing panel mounting open execution 50KA 415V 50Hz 4P MCCB (Ics=Icu, adustable Ir setting 0.5-1, neutral adjustable with earth fault protection and with rotary handle) (without enclosure) of the following capacity complete with making necessary connection as specified and directed by the deptt.- 50KA 415V 50Hz 4P MCCB ( Make- Schneider, Legrand, Siemens, Hager) 50KA 415V 50Hz 4P MCCB2Nos.
251251Supplying including installation of 100 mm dia C.I. Earth Pipe complete as required and directed by the Department. 100 mm dia C.I. Earth Pipe7Nos.
252252Supplying and fitting, fixing of H.T. Danger Plate as required and directed by the Department.100 mm dia C.I. Earth Pipe4Nos.
253253Supplying including fitting & fixing of P.G Clamp for Rabbit conductor as required and directed by the Department.P.G Clamp for Rabbit conductor16Nos.
254254Extra for using salt (5 kg) and Charcoal (64 kg} for pipe earth station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the department. salt and Charcoal \n7Nos.
255255Supplying , fitting & fixing of three phase energy meter as required and directed by the Department. Three phase energy1Nos.
256256(Supplying , fitting & fixing of metering cabinate as required and directed by the Department.metering cabinate2Nos.
257257Supplying , fitting & fixing of three phase LT/CT Trivector energy meter as required and directed by the Department.LT/CT Trivector energy meter1Nos.
258258Supplying , fitting & fixing of bio-metalic aluminium lugs (Assorted) as required and directed by the Department.bio-metalic aluminium lugs-Assorted24Nos.
259259Providing and laying 6 SWG., G.I earth wire (below GL) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the Department.6 SWG., G.I earth wire80Rm
260260Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laidup,PVC tape inner sheathed,Unarmoured/ Armour (Galvanised for cables upto 10x1.5 sqmm. 8x2.5 sqmm. 2x 10 sq mm. 3x10 sqmm. 4x6sqmm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/ 1100V grade as per IS7098 (Part1)1988, U.G.cable laid in ground/ partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil,debriset to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/ CCI/ Polycab/Gloster /Finolex make)- 70.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe .40Rm
261261Supplying and making end termination with Double compression brass gland with Nickel plated lugs for following size of PVC insulated and PVC sheathed / XLPE Al conductor cable of 1.1 KV grade as required.- Flame poof(CBF)-Size70 size:2.5-78,3-1/4\"12Nos.
262262Supplying including fitting & fixing of P.G Clamp for Rabbit conductor as required and directed by the Department.16Nos.
263263Providing barbed wire on the existing barbed wire fencing with seven strands of barbed wire 12 S.W. G.x 2pliesx 4 points at 75mm apart including supplying, fitting and fixing with galvanised staples 38mm x 38mm x 3mm sizes with existing posts of the fencing, including removing rotten barbed wire as directed, complete with strengthening of post and tightening of the old barbed wire and joinining old serviceable pieces on remaining lines as and where necessary and as directed.40Rm
264264Supplying and laying of HDPE pipe/duct IS-4984:1995 as required in the existing trench, through micro tunnelling as directed and specified by the Department.- 90 mm PE63 GRADE PN1020Rm
265265Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch(IP-20 protection) in powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the Department.- C&S, Havells, Indo Asian, HPL, GECO make-100 A Four Pole 415V Front handle operated On Load Change over switch1Nos.
266266Load security and supervision charge payable to APDCL as required and directed by the Department. 50KW load50KW
267267I) INTERNAL ELECTRIFICATION AT TREATEMENT PLANT
268268Wiring for light/fan / call bell point with 2x 1.5 sq. mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Kebel/Finolex/Havells or equivalent Make as approved by the deptt) with flat 19 mm ISI marked casing 'n'capping (AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) in surface system, including 6 Amp flush type switch /bell push (Anchor Penta/Gold Medal/Kolor Kany.com/ Havells oe equivalent Make as approved by the deptt) , GI/MS switch board (ISI Marked) half conceale on wall with phenolic laminated sheet cover, Ceiling rose (Anchor/Gold Medal/Kolor Kany.com/ Havells oe equivalent Make as approved by the deptt) etc. complete as directed and as specified by the deptt.\n
269269a) Short point upto 3.00 metre length8point
270270b) Medium point upto 6.00 metre length8point
271271c) Long point upto 10.00 metre length.12point
272272Supplying and fixing 18 S.W.G. sheet metal boxes of following nominal size in surface wiring system fitted with suitable size phenolic laminated sheet covers in front face of the boxes including painting etc. as require and as specified by the department
273273200 mm. x 250 mm. X 60 mm. deep. (Nominal size)2Nos.
274274250 mm. x 350 mm. x 60 mm. deep. (Nominal size)4Nos.
275275Supplying and fixing of switch/socket on the existing board including connections etc. complete. (I.S.I. approved)
2762766 Amps flush type switch (one way)20Each
27727716 Amps flush type switch.2Each
2782783 Pin 6 Amps flush type socket outlets4Each
2792793 Pin 16 Amps flush type socket outlets.2Each
2802805 Pin 16 Amps flush type multi switch and socket outlets combined unit.2Each
281281Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Cable/ Finolex or equivalent Make as approved by the deptt.) in surface flat ISI marked casing 'n' capping (AKG /Precision/Presto Plast/ Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity-
282282With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm in flat 19 mm ISI marked casing 'n' capping system.120Rm
283283With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in flat 19 mm ISI marked casing 'n'capping system.100Rm
284284Supplying with fitting fixing of CFL/Flourescent luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection as approved by the deptt, with 1.5 sq. mm PVC insulated single core copper conductor as reqd. and as directed by the Deptt. Striplite luminaries complete with VPIT copper ballast/electronic balast and decorative end cap and 1 X36/ 40 watt. Flourescent tube. (Crompton Greaves make), Model- DSG1114LDB CROM GOLD/ DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD /DSG 1414 EB PLANET GOLD WITH super saver/super Brite lamp or equivalent ( equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO / HAVELS/ HPL/ SOLAR /JAQUAR MAKE.12Nos
285285Supplying, installation, testing and commissioning of following outdoor flood light of LED/MH/HPSV luminaries complete with all accessories such as ballast, capacitor, lamp, ignitor and driver as required complete with necessory support /foundation with 2.5 sqmm PVC insulated single core copper conductor as reqd. and as directed by the Deptt.-- MVC 502 1 xMHNTD-150W Philips make flood light luminaries with cast Aluminium housing and toughened glass cover including seperate CG box or equivalent ( equivalent will be selected by the deptt considering the mother items rate) BAJAJ/ WIPRO / HAVELS/ Crompton / HPL/ SOLAR/ JAQUAR MAKE.5Nos
286286Supplying including installation, commissioning of vermin and dust proof totally enclosed Phosphetised powder painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.95 M(B) x 1.20 M (H) x 0.40M (0) made of 16 SWG (1.66 MM) thick C.R. sheet and 40mm x40mmx 5 mm size angle having 4 Nos. legs at the bottom. The panal Board is to be erected in 1:3:6 PCC foundation including brick soling/grouting etc. complete neatly wiring done with provision for one no 800 A, 4 pole MCCB or switch fuse unit as incomer and provision for 4 Nos DP or TPN outgoing as specified and as directed by the department conforming to IP-43 protection comprising of the following electrical items:\n1) 50mm x 10mm 4 strip copper Bus-Bar 1.20 M length each-4 set\n2) 20mm x 3mm 4 strip copper Bus-Bar 0.50 M length each-4 set\n3. Digital 3 phase Voltmeter Accuracy class 0.50- 1 Nos\n4. Digital 3 phase Ammeter Accuracy class 0.50- 1 Nos\n5. Pilot Lamp with integral Circuit LED 110-230 V (Red, Yellow & Blue)- 3 Nos.\n6. Voltmeter & Ammeter Selector Switch-2 Nos.\n7. 2A Slide fuse unit- 3 Nos\n(Outgoing Switch Gear of reqd. rating will be measured and paid separately )\n1Nos
287287Supplying with fitting and fixing panel mounting open execution 50KA 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu), adjustable Overload and short Circuit setting , without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. [ABB/ Schneider,/ Legrand/ L&T, Siemens/ Hager C&S Make)- 100 A. ( For 3 Nos 40HP RWPS and one for transformer site= 4 Nos)4Nos
288288Supplying with fitting and fixing 4P, 10 KA 415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt.- C series [ABB, Schneider MG, Legrand, Hagger, Crabtree Xpro make]- 6 to 32 A ( For Vaccum pump and lighting the internal & external area-4 Nos)4Nos
289289Supplying of vacuum pump starter for 3HP (DOL)2Nos
290290Supplying with fitting and fixing including necessary connection as approved by the department D.O.L Starter (Cromton Greaves/ Control and switch gear/ BCH/L&T/ Siemens Make) of following type and capacity as specified and directed by the deptt. D.O.L starter-25HP, 24 to 39A (2 Nos for CWP & 1 standby)3Nos
291291Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, unarmoured/ Armoured (Aluminium for single core upto 70 sq mm balance aluminium strip), Galvanised for cables upto 2x10 sqmm, 3x10 sqmm,4x6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650 /1100 V grade as per IS:7908 (Part-1) 1988 laid in air or through existing cable trench /duct /cable tray / HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the depertment (Nicco/ Havells/ RPG/CCI/ Polycab/Gloster / Finolex make or equivalent)-
2922924 mm2 3 core armoured Cable (panel to external light post 8 nos x 20m av length )130Mtr
293293a) 6mm2 3 core armoured Cable (panel to Vaccum pumps)18Mtr
294294b) 50.00 mm2 3&1/2 core armoured Cable (panel to 2 Nos of starter for Clear water pumps)56Rm
295295c) 95 Sq.mm 3 and 1/2 core armoured cable (transformer to Panel Board- 150 Rm)130Rm
296296Supply with installation & commissioning of readymade maintenancefree CPRI approved chemical earthing system with 50MM dia. .00 Metres length corrossion free dualpipe technology G.I. CHEM ROD EELECTRODE complete with RESLOW Grounding Minerals (25KG) and Advance Earth Pit cover (PVC) including excavation of earthpit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.2Nos
297297Supplying and laying of 25x6 mm size G.I. strips drawn of surface from earth electrode to Electrical switch gears, machineries etc. complete with supply of G.I. nuts & bolts, screws etc complete etc. including riveting, soldering & making necessary connection as approved, specified and directed by the department.40Rm
298298Supplying with fitting and fixing of the following integral type street light luminaries complete and consisting of single piece integral opexy gray powder coated dia cast alluminium housing gasket, pot optic reflector, cast alluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp holder, Balast, lamp etc. in the existing pole including making necessary connection as approved by the deptt. with 2 x 2.50 sq mm F.R multi stand and P.V.C insulated single core copper cable as specified and directed by the department.= Philips make Cat. No-SRP 308 1XSON 70W FG for lamp SON70W /cROMPTON GREAVES make-SSSG12071H/FG FOR LAMP 1X70W HPSV/ HAVELS MAKE-LHRS13170A99 FOR LAMP1X70W SON -E12Nos
299299Supplying including fitting fixing of high speed A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections etc. as required complete and as directed by the Department [Without regulator].- Standard model 1200mm sweep (Usha make)6Nos
300300Supplying including fitting fixing of Electronic STEP Type Regulator for ceiling fan complete with all connections in the existing board as required complete and as directed by the department.6Nos
301301J)ESTIMATE FOR SUBMERSIBLE AND CENTRIFUGAL PUMPING SETS
302302Supply, installation, testing and commissioning of electrical driven Submersible Raw water pumping set (couple type) suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/delta/star as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect (excluding rising delivery pipes and specials fitting, fixing & testing etc.).Discharge 32.16 LPS, Head 45 M , Length of Raw Water Pumping Main=1500.M)\nSupplying and fixing required size of copper cable ( branded ) for power line from pane board to starter and starter to motors as per specifications of the above mentioned pumping sets. 70.00 sqrm\nSupplying, placing, laying, fitting and fixing of suction / delivery of 100 mm dia G.I pipes (TATA, Medium) along with its accessories/specials etc. as per requirement in the field for the above mentioned pumping set as per specifications.\n60HP
303303Supply, installation, testing and commissioning of electrical driven Centrifugal clear water pumping set (couple type) suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/delta/star complete set as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as base frame, coupling, guard foundation, bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect including construction of foundation all complete including suction and delivery mains/pipes, specials, fitting, fixing etc..\nSpecification:\nHorizontal split casing centrifugal pump type\nRPM of Motors be 1400 to 1500\nConstruction materials – cast iron casing, stainless steel shaft, Bronze impeller.\nHead -35 .00 M\nRPM -1400 to 1500 \nDischarge -32.64 LPS\nCasing -Cast Iron\nShaft -Stainless steel\nImpeller -Bronze Iron\nLength of clear water Pumping Main -100.00M\n65HP
304304K) Road restoration Work
305305Construction of granular sub-base by providing coarse graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place methof with rotavator at MC, and compacting with vibratory roller to achieve the desired density , complete as per cl.401 (with an initial lead of 5 km.)
306306100 mm dia --3280 meter262.4Cum
307307150 mm dia --1440 meter122.4Cum
308308200 mm dia --289.60 meter26.05Cum
309309250 mm dia -841.60 meter79.95Cum
310310300 mm dia --1008.80 meter100.88Cum
311311Providing laying ,spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with vibratory roller 8 to 10 tonnes instag3es to proper grade and camper ,applying and brooming requisite type of binding material to fill up the interstices’ of coarse aggregate watering and compacting to the required (with an initial lead of 5.0 km)WBM Gr. II
312312100 mm dia --3280 meter196.8Cum
313313150 mm dia --1440 meter91.8Cum
314314200 mm dia --289.60 meter19.55Cum
315315250 mm dia -841.60 meter59.96Cum
316316300 mm dia --1008.80 meter75.66Cum
317317Providing laying ,spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with vibratory roller 8 to 10 tonnes instag3es to proper grade and camper ,applying and brooming requisite type of binding material to fill up the interstices’ of coarse aggregate watering and compacting to the required (with an initial lead of 5.0 km)WBM Gr. III
318318100 mm dia --3280 meter196.8Cum
319319150 mm dia --1440 meter91.8Cum
320320200 mm dia --289.60 meter19.55Cum
321321250 mm dia -841.60 meter59.96Cum
322322300 mm dia --1008.80 meter75.66Cum
323323Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical with the bitumen emulsion CSS-1h.
324324100 mm dia --3280 meter196.8Cum
325325150 mm dia --1440 meter91.8Cum
326326200 mm dia --289.60 meter19.55Cum
327327250 mm dia -841.60 meter59.96Cum
328328300 mm dia --1008.80 meter75.66Cum
329329Open graded premix surfacing /Mixed seal surfacing (Mechanical means using HMP of capacity not less than 75 tonnes/hour. Providing, laying and rolling of open graded premix surfacing of 20 mm thickness composed of 13.2mm to 5.6 mm aggregates either using penetration grade bitumen (60/70 grade) or bitumen emulsion to required line, grade and level to serve as wearing coarse on a previously prepared base, including mixing in a suitable plant laying and rolling with a smooth wheeled roller 8-10 T capacity to the road level and grade.(Including carriage up to initial lead of 5.0 km from quarry and carriage of mixed materials up to 10.0 km initial lead from mixing plant) ( Including cost of testing of materials at site and laboratory as directed by the deptt.)
330330100 mm dia --3280 meter196.8Cum
331331150 mm dia --1440 meter91.8Cum
332332200 mm dia --289.60 meter19.55Cum
333333250 mm dia -841.60 meter59.96Cum
334334300 mm dia --1008.80 meter75.66Cum
335335Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats.) (Including carriage up to initial lead of 5.0 km from quarry) (Including cost of testing of materials at site and laboratory as directed by the deptt.)
336336100 mm dia --3280 meter196.8Cum
337337150 mm dia --1440 meter91.8Cum
338338200 mm dia --289.60 meter19.55Cum
339339250 mm dia -841.60 meter59.96Cum
340340300 mm dia --1008.80 meter75.66Cum
341341L) DEVELOPMENT OF TWO NOS DEEP TUBE WELLS
342342Transportation of air compressor from the Divisional Head Quarter to the drilling site with all accessories including cost of P.O.L. all complete as directed.Upto 100.00 Km distance from Divisional H.Q60Per Km
343343Transportation of P.O.L. all complete as directed30Litre
344344Construction of temporary accommodation and low cost sanitary facility for drilling staff including cost of camp materials viz. cots, tables, chairs, utensils, dresses, safety helmets etc. and dismantling the accommodation after completion of the work all complete as directed.1job
345345Developing of the D.T.W. with air compressor,( For 2 nos Deep Tube Well -- 60 hours x 2 nos )120hour

AI Tender Summary

OUR REF NO 24986475
AUTHORITY Government Departments
TENDER VALUE 3.62 Crore
LAST DATE 03-08-2020
Authority
Authority Name Assam Urban Water Supply And Sewerage Board
Work Description Augmentation Of Dergaon Water Supply Scheme Execution , Testing And Commissioning Of 2 . 35 Mld Capacity Treatment Plant , Distribution , Raw Water Pumping Main , Submersible , Centrifugal Pumping Sets , Electrical Internal , External And Drawing Power Line , Sub Stations , Development Deep Tube Wells
Basic Detail
Tender No NIT 42 of 2019-20 dated 20-03-2020
Bidding Type Tender
Location
City
State Assam
Key Dates
Publish Date 24 Jul 2020
Submission Date 03 Aug 2020
Open Date 03 Aug 2020
Finance
Tender Value 3.62 Crore
Tender Fee 6000
EMD 7.24 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_28114.xls
BidDocumentDergoan.pdf
corrigendum.pdf
RetenderNotice.pdf
5FE49385-0EA1-43AA-8A67-00BA79E13232.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 03, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 03, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_28114.xls

pdf

BidDocumentDergoan.pdf

pdf

corrigendum.pdf

pdf

RetenderNotice.pdf

html

5FE49385-0EA1-43AA-8A67-00BA79E13232.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender