Tender For Design, Supply, Installation, Testing And Commissioning Of Chp Engine And Bio-Gas Plant Including Sourcing Of Required Waste For Bio Digestor For Permanent Campus Of Nalanda University (Phase-1), RAJGIR-Bihar

Nalanda University has published Tender For Design, Supply, Installation, Testing And Commissioning Of Chp Engine And Bio-Gas Plant Including Sourcing Of Required Waste For Bio Digestor For Permanent Campus Of Nalanda University (Phase-1). Submission Date for this Tender is 24-08-2020. Bio Gas Plant Tenders in RAJGIR Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

24977971
Tender For Design, Supply, Installation, Testing And Commissioning Of Chp Engine And Bio-Gas Plant Including Sourcing Of Required Waste For Bio Digestor For Permanent Campus Of Nalanda University (Phase-1)
National Competitive Bid
Indian
Bihar
RAJGIR
24-08-2020

Tender Details

Tender For Design, Supply, Installation, Testing And Commissioning Of Chp Engine And Bio-Gas Plant Including Sourcing Of Required Waste For Bio Digestor For Permanent Campus Of Nalanda University ( Phase-1 )

Key Value

Document Fees
INR 6000 /-
EMD
INR 2273000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Tender for Design, Supply, Installation, Testing and Commissioning of CHP Engine and Bio-Gas Plant including sourcing of required waste for Bio Digestor for Permanent Campus of Nalanda University (Phase-1)
Sl. No. Description of Work UNDER EPCC MODE CONFIRMING TO THE BOQ AS PER THE SITE REQIREMENT Item Code / Make Quantity Units
1 1 Design, Supply, Installation, Testing and Commissioning of Bio Gas plant including IOT automation integrated solid waste segrigation and disposable station in turn key basis having per day capacity of 110 NCum per Hour for 24 Hours Continuously suitable for running 200 KWe CHP unit with heat recovery ,including designing of the plant, construction of plant, installation of required equipments as per design, testing and commissioning of the plant and running of the same till stabilisation period of 6 months providing required output of gas as per the requirement. The Design shall include all the components of the Bio Gas PLant including shredder, Agitators, Pumps, required tanks, Anaerobic Digestor, H2S Scrubber to get cleaner biogas, Required valves, Piping, Flow meters for Gas, Storage for Bio Gas, Air Blowers, Pressure Guages, Pressure Release valves, Bio Gas Flaring system with Safety Arrangements, Filter press for dewatering slurry and making manure and packing of the same, Compressor for compressing the Biogass, Gass Cascade system to store the gas in compressed form of the similar capacity, all plumbing works, all electrical works, all automation works including integration with the SCADA/BMS system of the campus to show the status of the plant, Fire Alarm and Fire Fighting works, Safety and Directional Signages, etc... complete as required. The technology should be suitable adaptable to local tropical conditions, with lowest operating cost, least possible land use for the processing and disposal of the organic waste as directed by the Engineer-In Charge. Tenetative heads. species and requirements are given in technical specification read with the drawings, the sucessfull contrcator has to seek quantities approval as per the design confirmation by the cleint. irrespective of the solid waste collected from the campus will be useful for the generation of the biogas or not, as a part of campus waste management strategy, this includes developement of the Disposal Station for (i) biodegrdable, solid , Recyclable waste collection from various part of the campus and its desposal stations with the features of Segregation and Storage of Recyclable Waste. Waste Storage and Recycling facility has to be designed and developed at the site . Shade shuold be fabricated as per the design and required civil work should be done as per drawing and design. For the bio & solid (degrdable & non-degradable both) was te collection from the various parts of the campus, the required bins and containers are seperate to this line item under EPCC mode. However, the vehicle /trcator to load-unload the dumper will be facitilated by the contrcator without any extra charge. \nThe process design has to be submitted by the vendor which shall be vetted by Third part vetting agency and on approval of the same, the actual work can be started at site. 1 1 Nos
2 2 Supply, Installation, Testing and Commissioning of Biogas/ PNG fueled Duel Fuel cogeneration (CHP) engine capable of generating 1000 KWe electrical energy on continuous basis including Waste Heat Recovery Unit with water jacketing for heat transfer and generation of hot water including hot water generator and heat exchanger of suitable size, Voltage- 415 V, Frequency - 50 Hz with H class insulation & including Housing of CHP, Common base frame, anti-vibrating isolators, flexible coupling for engine/alternator & painting as per manufacturers standard, starting battery & battery charger, Automatic voltage regulator,Panel, including control cubicle and associated auxiliary devices, Earthing system, relay panel and CHP breaker, Step up transformer (0.440/11 kV) suitable for proposed gas genset including LT incomer, HT outgoing, required size breaker and related cabling, Suitable LT panel and HT Panel both (HT panel shall be syncying/ Parallel operation with the grid and LT panel for direct use of the generated electricty in the respective zone for example Academic Spine or suitable in case of HT side faliure or any other requirement) including necessary heat exchanger to generate hot water, complete with Fuel Gas Train, Engine Exhaust systems, Acoustical Enclosure for the CHP, data acquisition system with SCADA/ BMS compatibility, Necessary Cabling, Trenching, refilling, Hot water storage tanks and Hydro-pneumatic pump.\n\nA logic control panel shall be part of this item which shall be able to sence the power availibility from various sources (Grid, DG Sets & Solar etc - Maximum 4 sources at a place) & also sense the load demand on down side & accordingly give command to all required breakes of the respective sources including CHP breaker based on load sharing scenario by means of load sharing realy & synchronizing realys to manage the source optimization. All required sensors, sensor cables, transducers, control cables, relays, meters, accessories, hardware & software shall be provided in this item. (Note: Logic shall be set so in normal mode if load is upto capability of CHP than only CHP shall supply the power, if load increases than CHP + GRID shall supply the power in synchronizing & in case of grid failure based on load either (in priority) CHP shall feed the power or Dg Set + CHP shall feed the power in synchronizing to the load) The process design has to be submitted by the vendor CONFIRMING TO THE SITE/CLIENT REQUIREMENT which shall be vetted by Third part vetting agency and on approval of the same the actual work can be started at site. Detail BOQ shall be prepared as per the site requirement confirming to the NIT read with drawings and TS. Tenetative heads. species and requirements are given in technical specification read with the drawings, the sucessfull contrcator has to seek quantities approval as per the design confirmation by the cleint.\n\nBattery Limits:\nPower Evacuation to the substation within 200 meters from CHP HT Panel/ LT Panel. Cabling to be done by the vendor.\nHot water at distance of 100 meters from CHP Unit. Necessary Storage and Pumping to be provided by Vendor.\n 2 1 Set
3 3 Supply, Installation, Testing and Commissioning of Biogas fueled cogeneration (CHP) engine capable of generating 200KWe electrical energy on continuous basis including Waste Heat Recovery Unit with water jacketing for heat transfer and generation of hot water including hot water generator and heat exchanger of suitable size, Voltage- 415 V, Frequency - 50 Hz with H class insulation & including Housing of CHP, Common base frame, anti-vibrating isolators, flexible coupling for engine/alternator & painting as per manufacturers standard, starting battery & battery charger, Automatic voltage regulator,Panel, including control cubicle and associated auxiliary devices, Earthing system, relay panel and CHP breaker of suitable size, LT Panel, HT Panel if required, including necessary heat exchanger to generate hot water, complete with Fuel Gas Train, Engine Exhaust systems, Acoustical Enclosure for the CHP, data acquisition system with SCADA/ BMS compatibility, Necessary Cabling, Trenching, refilling, Hot water storage tanks and Hydro-pneumatic pump.\n\nA logic control panel shall be part of this item which shall be able to sence the power availibility from various sources (Grid, DG Sets & Solar etc - Maximum 4 sources at a place) & also sense the load demand on down side & accordingly give command to all required breakes of the respective sources including CHP breaker based on load sharing scenario by means of load sharing realy & synchronizing realys to manage the source optimization. All required sensors, sensor cables, transducers, control cables, relays, meters, accessories, hardware & software shall be provided in this item. (Note: Logic shall be set so in normal mode if load is upto capability of CHP than only CHP shall supply the power, if load increases than CHP + GRID shall supply the power in synchronizing & in case of grid failure based on load either (in priority) CHP shall feed the power or Dg Set + CHP shall feed the power in synchronizing to the load)\nThe process design has to be submitted by the vendor CONFIRMING TO THE SITE/CLIENT REQUIREMENT which shall be vetted by Third part vetting agency and on approval of the same the actual work can be started at site. Detail BOQ shall be prepared as per the site requirement confirming to the NIT read with drawings and TS. Tenetative heads. species and requirements are given in technical specification read with the drawings, the sucessfull contrcator has to seek quantities approval as per the design confirmation by the cleint.\n\nBattery Limits:\nPower Evacuation to the substation within 200 meters from CHP HT Panel/ LT Panel. Cabling to be done by the vendor.\nHot water at distance of 200 meters from CHP Unit. Necessary Storage and Pumping to be provided by Vendor.\n Detail BOQ shall be prepred as per the site requirement confirming to the NIT read with drawings and TS\n 3 1 Set
4 4 Providing and supplying of Bio- gas having minimum methane content of 55% and H2s content less than 1% and having minimum calorific value of 5000 Kcal/ m3 at minimum pressure as required for the CHP engine including required piping and sourcing of waste required as feed for the Bio gas plant including cow dung, Poultry Waste, kitchen waste, Agriculture waste or any other waste capable of generating the required quality of Bio Gas, to be collected from the nearby villages, vegetable markets, agricultural lands, dairys etc in the radius of 150 Kms around the campus initialy for a period of 60 months from the date of commissioning and handing over of the Bio Gas plant including operation and maintenance of the plant with required manpower, vehicle maintenance, Feed Transportation to site, safety equipments for plant and for workers, project staff, to ensure entire system functionality etc as per the requirement and as directed by the Engineer In Charge. \n(THOUGH IN THE SEBSEQUENT YEAR EXPECTED ANNUAL DEMAND IS FORECASTED TO BE 832200 SCM BIOGAS WHICH MAY INCREASE OR DECREASE AS PER THE UNIVERSITY REQUIREMENT. FOR 1ST YEAR- THE EXPECTED BIOGAS REQUIREMENT IS FORECASTED HARDLY 75 % OF THE FULL CAPACITY AS THE UNIVERSITY WILL TAKE TIME TO GROWNUP AND CAMPUS MAY FUNCTION AT 50 OF LOAD. HOWEVER, THE CONTRACTOR HAS TO ENSURE THE GENERATION OF BIOGAS INCLUDING ALL ASSOCITED JOB, FEED COLLECTIONS , SAFETY ETC AS PER THE ACTUAL REQUIREMENT. THIS SERVICE SHALL BE EXTENDED INITIALLY FOR FIVE YEARS CONFIRMING TO THE SERVICE LEVEL MATRIXAGREEMENT GIVEN IN THE TS. THE GAS DEMAND MAY INCREAE OR DECREASE AS PER THE UNIVERSITY REQUIREMENT WHICH MAY BE CONFIRMED IN A MONTH ADVANCE OR /AND MUTUALLY AGREED UPON AND DIRECTION OF THE IN-CHARGE. 5% OF ANNUAL ESCLATION WILL BE GIVEN ) 4 624150 SCM
5 5 For NU Campus - Waste container dust bins 12 ltr with handle and lid confirming IS: 12402, HDPE, Bin Capacity (Volume) (Ltrs) 10 Litres, Weight of Dustbin (Complete unit) (Grams) 414 per container, Colour green/YELLOW/RED, Load carrying Capacity (Kgs) 12, No. of Compartments in the Bin- single, Lid removable, UV Resistant yes, For REF- https://mkp.gem.gov.in/waste-containers-rigid-liners-dust-bin-garbage-bin/prince-waste-container-dust-bins-12-ltr-with/p-5116877-83358878012-cat.html#variant_id=5116877-83358878012. Before supply, client permission will be required. \n\n\n 5 21 Set
6 6 For NU Campus -Office Twin bins twin bins foot pedal operated, CM/L No (If ISI Marked Yes) (If No write NA) CML 614, confirming IS: 12402, HDPE, Bin Capacity (Volume) (Ltrs) 10 Litres, Weight of Dustbin (Complete unit) (Grams) 9500 per container, Colour green/YELLOW/RED, Load carrying Capacity (Kgs) 20, No. of Compartments in the Bin- twin, Lid removable, UV Resistant yes, Wall Non- Perforated, Lid foot pedal operated, with Handle, For Ref - https://mkp.gem.gov.in/waste-containers-rigid-liners-dust-bin-garbage-bin/twin-bins-twin-bins/p-5116877-40135621349-cat.html#variant_id=5116877-40135621349 OR https://mkp.gem.gov.in/waste-containers-rigid-liners-dust-bin-garbage-bin/dry-waste-wet-waste-dustbin-dry-waste-wet/p-5116877-92212111681-cat.html#variant_id=5116877-92212111681\n 6 51 Set
7 7 For NU Campus -Office Waste Bins- WASTE BIN TWIN TYPE , Material LLDPE, Bin capacity (in Litres) 30, Container shall be supply with Lid Foot Pedal Operated, Weight of Dustbin (Complete unit) (in Grams) - Must be declare" 7500 Color of the container Other than Green/Blue Wheel Lock No Load carrying Capacity (Kgs) - Must be declare 60 Wall Non- Gripping provision Frontal . No. of compartments in the Bin Twin Bin Dust Bin Stand With stand UV Resistant. \n 7 25 Set
8 8 Canteen Waste Bins - Four Bin Waste Segregation System SS 60 Ltr, Public (Mobile containers confirming IS: 12402), C (For Public Dustbins) Type B (with 4 pivoting castors), Bin Capacity (Volume) (Ltrs) 60 Litres, Wheel Dimension in (mm) (Diameter x Thickness ) (mm x mm)- 310X410X190, Weight of Dustbin (Complete unit) (Grams) 1280, Wall Non- Perforated, Lid foot pedal operated, with handle and wheel. Towage Provision yes, Gripping Provision Both Frontal &Ventral, UV Resistant yes, IOT/QR/sensor based GIS Integrated system for auto tracking system 8 10 Set
9 9 Canteen Waste Bins- Four Bin Set Waste Segregation System with Stainless Steel Trolley Capacity 22 Ltr. Each Four Bin Set, Public (Mobile containers confirming IS: 12402), C (For Public Dustbins) Type B (with 4 pivoting castors), \nBin Capacity (Volume) (Ltrs) 20 Litres, Wheel Dimension in (mm) (Diameter x Thickness ) (mm x mm)- 280X390X170, Weight of Dustbin (Complete unit) (Grams) 37000, Wall Non- Perforated, Lid foot pedal operated, with handle and wheel. Towage Provision yes, Gripping Provision Both Frontal &Ventral, UV Resistant yes, IOT/QR/sensor based GIS Integrated system for auto tracking system . Material Stainless steel, Lid removable. 9 10 Set
10 10 Out-Door Waste Bins- OUTDOOR DUST BIN 50 LTR TWIN BIN DUST BIN 50 LTR TWIN BIN, Material LLDPE, Weight of Dustbin (Complete unit) (Grams) 16000, Colour green, Wheel Lock, Load carrying Capacity (Kgs) 100\nWall Non- Perforated, Lid Swing type, Gripping Provision Both Frontal &Ventral, UV Resistant yes Dust Bin stand, No. of Compartments in the Bin Twin Bin, IOT/QR/sensor based GIS Integrated system for auto tracking system . Material Stainless steel, Lid removable. 10 50 Set
11 11 For NU Campus -Outdoor 1100 Ltr DUSTBIN , UtilityPublic (Mobile containers confirming IS: 12402), Class confirming to IS:12402 (For Public Dustbins)Type B (with 4 pivoting castors),MaterialHDPE,CAPACITYBin Capacity (Volume) (Ltrs)1100 Litres, DIMENSIONSWheel Dimension in (mm) (Diameter x Thickness ) (mm x mm)200X60, Weight of Dustbin (Complete unit) Grams)50000, CONSTRUCTIONALColourgreen & OTHERS AS PER DESIGN,  Load carrying Capacity (Kgs)1100, Wall-Non- Perforated, Lid-hinged, with handle & wheel ,  Wheel Material-PVC, Towage Provision-yesGripping ProvisionBoth Frontal &Ventral\nUV Resistant-yes,  No. of Compartments in the Bin single,  IOT/QR/sensor based GIS Integrated system for auto tracking system . Material Stainless steel, Lid removable. \n 11 10 Set
12 12 For NU Campus -Garbage container 2 cubic meters (Pragati Engineering /equivalent, (container for tipper) Material-Corrosion free sheet metal, CAPACITYBin Capacity (Volume) (Ltrs)-500 Litres (as per IS: 12402 Pt1 and 2),  Weight of Dustbin (Complete unit) (Grams)-20000, CONSTRUCTIONALColouras per design approval  ,Load carrying Capacity -Kgs)- 2000, Wall-Non- Perforated, Lid-removable,  Gripping Provision-Frontal, Plugged outlet for washing & draining-Without,  No. of Compartments in the Bin- Twin Bin,  Vehicle /tipper for its carriage from waste collection point inside campus to waste dispossal and segrigation station will be in the scope of the contrcator as a part of gas supply including loading unloading all. This job is conditional and part of the system without any additional charge for carriage of the waste container from vaious part of the campus to /fro waste disposal & segrigation station. IOT/QR/sensor based GIS Integrated system for auto tracking system . Material Stainless steel, Lid removable. \n 12 8 Set
13 13 For NU Campus -Support for the campus waste collection - Colour of E CartGREEN and BLUE as per the University approval. The E Cart Must Fabricated From Good Quality Steel properly Painted to avoid Rusting for more than 5 Years,YES, Name and Grade of Steel from which E Cart Body FramedMS, Kerb Weight of E- Cart (kg)342 kilogram or equivalent, Garbage Carrying Capacity (kg)309 kilogram, minimum -300KG, Run Distance (for a Full Charge of Battery , to be tested with full load at maximum AIS-040 )) (km)80, Number of Bins2, Capacity of Individual Bins in litres (Ltrs)750 liter, Type of Chassis for E cartMT, Ground Clearance as per IS : 9435 (mm)2100, Wheel Base (mm) &Turning Radius (mm)2.88 millimeter or standard as per design, Power Transmission from Motor Shaft to WheelsOther Mechanical Mechanisms,  Type of Battery as per AIS-048Lead Acid , EV Grade , Tubular Deep Discharge, Capacity of the Battery approved by ICAT/ARAI (Ah)100, Battery Voltage ,Nominal (Volts)48V, Average  Dimensions of the Battery ( L x Wx H ) mm3)410*176*234, Nominal Filled Weight of the Battery (kg)118 kilogram, Motor Controller ( Must Suitable for starting, accelerating, decelerating, driving , and stopping of E CartAVAILABLE, Battery Charger-220/230 V Nominal Input Voltage , High Efficiency Type, Charging Current (A)-12, Type of Motor-Brushless DC Motor, Motor Output Power ,48V/60V at Full Load (watt)-1660, Overall Efficiency of the E Cart ( to be tested at Full Load with maximum speed as per Concerned AIS standards (%)- 88, Gradeability of E-cart , ( to be tested at full procedure as per AIS -003 Load (Degree)-75, Certification:Vehicle CertificationICAT, If Vehicle Certification from Others Agency ,Name of the Agency otherwise put NAICAT,  ConstructionalSeating Facility-For Driver only, Length of E -cart as per Gazette Notification by Ministry of Road and Transport Oct , 2014 (meters)-2.8, Width of E -Cart as per Gazette Notification by Ministry of Road and Transport Oct, 2014 (meters)-1, Height of E -Cart as per Gazette Notification by Ministry of Road and Transport Oct , 2014 (meters)-1.8, Dimensions of the cabin Provided for Bins (mm x mm x mm) (mm3)-1300*900*900, Size of Front Tyre (mm)-3.00-12, Size of Rear Tyre-3.00-12, Brake Type (Front)-DRUM, Brake Type ( Rear )-DRUM, Suspension System (Front)-HYDRULICSHOCKABSORBE, Suspension System ( Rear )-LEAF SPRING, Reverse Gear Facility-YesThe Mounting of Batteries-Yes, Vehicle lighting System-Filament Type, Instrument Panel Containing Speedometer and Battery Charging Indicator-Yes,Glass Windshield with wiper motor as approved by ICAT/ARAI-Yes, Equipped with Start and Stop Button, parking Lights , Back lights with Reverse Gear Facility-Yes, Equipped with Fire ExtinguisherYes, Equipped with First Aid Box-Yes, Yellow Color reflective tape on Front and Rear Side of the E Cart-Yes, E Cart Integration -Yes, Performance Parameters:Speed of the E- Rickshaw as per CMVR -2014 with latest amndmt (to be tested with Full Load ) (kmph)-20, Battery Warranty-1 year, No. Of Free Service-5, Compliance of Centre of Gravity of E Cart as Compulsory Norms for Safety-Yes, Confirming to Applicable Environmental Test-Yes, Noise level must be Low during Operation-Yes, Including vehicle registration act as per applicable rule.  The driver and labor support will be extended by the contractor. IOT/QR/sensor based GIS Integrated system for auto tracking system . Material Stainless steel, Lid removable. 13 1 Set
14 14 AMC (Manpower Support to undertake the operation of the CHP and related accessories installed at site) \nProviding following manpower support to undertake the operation and maintenance of the machinaries installed at site :\nMin 1 nos driver for Ecart, 2 nos labor for loading & unloading-if labor required, 3 Nos. certified Technician and 2 Nos. helper. However contractor may deploy more man power to ensure the smooth operation and pro rata calculation shall be performed on the basis of 1 No. Technician and 1 No. helper. The contractor has to maintain the service level agreement as stipulated in NIT.\nAMC for 1st year\n\n 14 1 Job
15 15 AMC for 2nd year 15 1 Job
16 16 AMC for 3rd year 16 1 Job
17 17 AMC for 4th year 17 1 Job
18 18 AMC for 5th year 18 1 Job