National Agri-Food Biotechnology Institute-NABI has published Supply, Installation, Testing & Commissioning Of Vrv Ac System With Ahu At Glass House, National Agri-Food Biotechnology Institute (Nabi), Knowledge City, Sector-81, Mohali-Punjab, India. Submission Date for this Tender is 06-08-2020. Air Handling Unit Tenders in NABI CAMPUS Punjab. Bidders can get complete Tender details and download the document.
Name of Work: <Supply, Installation, Testing & Commissioning of VRV AC system with AHU at Glass House, National Agri-Food Biotechnology Institute (NABI), Knowledge City, sector-81, Mohali-Punjab, India> | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1.1 | Supply, Installation, Testing and commissioning of factory built Floor Mounted double skin air handling units with existing VRV outdoor condensing units of suitable capacities to cater air load as mentioned below and suitable AHU kit. The units shall be of thermal break profile made of 40±2 mm thick panels miminum 4 rows deep cooling coil section suitable for DX Application with aluminium finned copper tubes (tubes thickness not less than 0.5 mm), filter section with 50 mm thick metal viscous/ washable synthetic type air pre filters, belt drive package with TEFC drive motor (IE-3 ) suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply compatible for drain connections, stainless steel (18G) drain pan with nitrile rubber insulation, auto purge valve wherever required, necessary vibration isolation arrangement, with metallic flange inside AHU, gravity louver complete as required and as per specifications, drawings and of following capacities.(Air Qty : 12000 CFM, Static Pressure : 65 mm). The coil tonnage shall be as per the heat load calculations and as per the site requirement. | ITEM1 | 1 | set |
2 | 1.2 | Lifting, shifting, positioning, vaccumization, installation, testing & commissioning of existing outdoor VRV units of rating 14.83Tr (18HP) | ITEM2 | 2 | Nos |
3 | 1.3 | Supply & Filling of Refrigerant R410A in Outdoor VRV units of rating 14.83Tr (18HP) | ITEM3 | 2 | Nos |
4 | 1.4 | Supply and Installation of Expansion kit suitable as per the site requirement | ITEM4 | 2 | Nos |
5 | 1.5 | Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (41.27 mm dia(OD)/Hard drawn with tube thickness minimum 1.62mm with 19mm thick insulation) | ITEM5 | 10 | metre |
6 | 1.6 | Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (28.58 mm dia(OD)/Hard drawn with tube thickness minimum 1.2mm with 19mm thick insulation) | ITEM6 | 10 | metre |
7 | 1.7 | Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (19 mm dia (OD)/Hard drawn with tube thickness minimum 1.2mm with 19mm thick insulation) | ITEM7 | 10 | metre |
8 | 1.8 | Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (15.86 mm dia (OD)/Soft drawn with tube thickness minimum 1.2mm with 19mm thick insulation) | ITEM8 | 10 | metre |
9 | 1.9 | Supply and Installation of Refnet Unit of suitable size as per the site requirement | ITEM9 | 1 | Nos |
10 | 2.1 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required(Thickness 24 Gauge sheet) | ITEM10 | 25 | sq.mtr |
11 | 2.2 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required(Thickness 22 Gauge sheet) | ITEM11 | 160 | sq.mtr |
12 | 2.3 | Supplying and fixing of 19mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. | ITEM12 | 185 | sq.mtr |
13 | 2.4 | Supply & Fixing of Acoustic lining of ducting with 10mm thick open cell Nitrile rubber having density 144-180 kg/m3 | ITEM13 | 25 | sq.mtr |
14 | 2.5 | Supply & Fixing of Canvas Connection for Supply & return Air ducts | ITEM14 | 2 | Nos |
15 | 2.6 | Supply & Fixing of GI drain piping with 6mm thick Closed cell elastomeric type Insulation of following size with clamps/supports etc. complete as per the site requirement (32 mm dia) | ITEM15 | 20 | metre |
16 | 2.7 | Supply, Laying, connecting, testing and commissioning of new control cum transmission copper flexible cable of size 2 core x 1.0 sq mm in suitable size existing PVC conduits between AHU & VRV outdoor units and to central remote, if applicable | ITEM16 | 30 | metre |
17 | 2.8 | Supply & Fixing of MS Heavy duty VRV Outdoor Units Frames | ITEM17 | 2 | Nos |
18 | 2.9 | Supply, Installation, Testing & Commissioning of AHU control and starter Panel with suitable rating VFD. Panel will contain Starter for AHU and ELCB for Outddor units. Panel will have the protection from Over voltage and under voltage etc. complete as per the site requirement | ITEM18 | 1 | set |
19 | 3.1 | Supply, Laying and fixing of one number XLPE insulated and PVC\nsheathed, Aluminium conductor power cable of 1.1 KV grade of following size\non existing cable tray as required- 4core x 16sq. mm (clamped with 1mm thick saddle) | ITEM19 | 30 | metre |
20 | 3.2 | Supply, Laying and fixing of one number XLPE insulated and PVC\nsheathed, Aluminium conductor power cable of 1.1 KV grade of following size\non existing cable tray as required- 4core x 10sq. mm (clamped with 1mm thick saddle) | ITEM20 | 15 | metre |
21 | 3.3 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, with GI cover, joined with connectors, fixed on the floor with painted MS Angular supports including G.I. bolts & nuts, etc. as required. (225 mm width X 50 mm depth X 1.6 mm thickness) | ITEM21 | 30 | metre |
22 | 3.4 | Providing and fixing 4.00 mm dia copper wire on surface or in\nrecess for loop earthing along with existing surface/ recessed\nconduit/ submain wiring/ cable as required. | ITEM22 | 60 | metre |
23 | 3.5 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. | ITEM23 | 20 | metre |
24 | 3.6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(4C X 10 sq. mm) | ITEM24 | 2 | Nos |
25 | 3.7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(4C X 16 sq. mm) | ITEM25 | 4 | Nos |
26 | 3.8 | Dismantling & Shifting of Existing duct to NABI stores as per the site requirement | ITEM26 | 1 | Lot |
27 | 3.9 | Supply & Installation of Duct Heaters of suitable capacity in supply air duct of AHU as per the site requirement | ITEM27 | 1 | set |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy