Repair/Maintenance Of Security Repair/Maintenance Of SecurityPerimeter/Road Lights Including AlliedWorks Under Age E/M At Bb Cantt , Srinagar, BB Cantt Srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Repair/Maintenance Of Security Repair/Maintenance Of SecurityPerimeter/Road Lights Including AlliedWorks Under Age E/M At Bb Cantt , Srinagar. Submission Date for this Tender is 19-08-2020. Street Lighting Tenders in BB Cantt Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

24973544
Corrigendum : Repair/Maintenance Of Security Repair/Maintenance Of SecurityPerimeter/Road Lights Including AlliedWorks Under Age E/M At Bb Cantt , Srinagar
Open Tender
Indian
Jammu And Kashmir
BB Cantt Srinagar
19-08-2020

Tender Details

Repair / Maintenance Of Security Repair / Maintenance Of Security Perimeter / Road Lights Including Allied Works Under Age E / M At Bb Cantt , Srinagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Aug-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 36000.0 /-
Tender Value
INR 18 Lakhs /-

BOQ Items

Name of Work:REPAIR/MAINTENANCE OF SECURITY PERIMETER/ROAD LIGHTS INCLUDING ALLIED WORKS UNDER AGE E/M AT BB CANTT, SRINAGAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and directed. 225 Cum
2 2 M&L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete all as specified and directed. 135 Cum
3 3 M&L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and directed. 90 Cum
4 4 M&L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and directed. 60 Cum
5 5 S&L sub class burnt bricks for cable protection complete all as specified and directed. 5 Per 1000
6 6 S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts sgrade, cross sectional area 10 Sqmm, 2 core laid in trenches complete all as specified and directed. 700 RM
7 7 M&L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles complete all as specified and directed. 0.5 Cum
8 8 M&L for PCC 1:3:6 type C1 with 20mm graded stone aggregate in foundation of poles/stays incl necessary form work complete all as specified and directed. 5 Cum
9 9 S&F in replacemet of MCCBs TP / FP 415 Volts 50HZ adjustable incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under:- Makes :- LEGRAND, SIEMENS, HPL, SCHNEIDER\n(a) MCCB 100 Amps TP, 415 volts 25 KA with thermal setting 4 Each
10 10 (b) MCCB 200 Amps 4 pole, 415 volts 35 KA with thermal and megnatic setting 3 Each
11 11 (c) MCCB 400 Amps 4 pole 415 volts 35 KA with thermal Each and megnatic setting 2 Each
12 12 (d) MCCB 160 Amps 4 poles, 415 volts 35 KA with thermal and megnatic setting 6 Each
13 13 M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and directed 6 Each
14 14 S&F GI pipe light grade 50 mm dia in trenches for cable protection/on pole/on wall complete all as specified and diretced. 12 RM
15 15 S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screw and single swan neck as specified type 410 SP - 31 (9 Mtr long) incl removing existing unserviceable poles of any type complete all as specified and as directed. (earth work and PCC will be measured and paid separately under relevant item of schedule 'A') 1 Each
16 16 S&F of FRP cable looping boxes with PVC sheet finish inside including MCB SP 1 No,heavy duty PVC connector 4 way Terminal strip 01 no & fixed to pole with suitable size clamp with nuts, bolts complete all as specified and as directed. 14 Each
17 17 S&F Timeline distribution board of 32 Amps 3 pole/230 volts-Digital time switch of Cat Pt No TL032DBO of Indoasian/L&T/Indoasian/Legrand complete all as specified and directed. 2 Each
18 18 S&F Bracket made out of GI tubing medium grade 40 mm bore , 90 cm long including MS clamps made out of MS flat iron 25 x 10 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed. 15 Each
19 19 S&F LED Street light fitting 70/ 72W, pressue die-cast aluminum complete fixing arragement complete all as specified and directed. 69 Each
20 20 S&F LED Street light fitting 120W, pressue die-cast aluminum complete fixing arragement complete all as specified and directed. 38 Each
21 21 S&F ON load change over switch 415 Volts 3 phase 4 pole 50Hz with metal encloseure of capacity 100 Amps including dimantling the existing complete all as specified and directed. 1 Each
22 22 S&F ON load change over switch 415 Volts 3 phase 4 pole 50Hz with metal encloseure of capacity 63 Amps including dimantling the existing complete all as specified and directed. 1 Each
23 23 S&F ON load change over switch 415 Volts 3 phase 4 pole 50Hz with metal encloseure of capacity 200 Amps including dimantling the existing complete all as specified and directed. 1 Each
24 24 LED light driver unit suitable for LED light fitting of capacity 45/48 watt complete all as specified and directed. 20 Each
25 25 LED light driver unit suitable for LED light fitting of capacity 60/66 watt complete all as specified and directed. \n 18 Each
26 26 LED light driver unit suitable for LED light fitting of capacity 72/80/90 watt complete all as specified and as directed. \nMake:- Bajaj / Philips / Havells / Surya/Gold win. 20 Each
27 27 S&F LED light driver unit suitable for LED light fitting of capacity 120/150/170 watt complete all as specified and directed. \n 15 Each
28 28 S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armoured power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm, 3.5 core laid in trenches complete all as specified and directed. 100 RM
29 29 S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armoured power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core laid in trenches complete all as specified and directed. 120 RM
30 30 S&F Energy saving sleek 40W LED Post top luminaire made of pressure die cast aluminum IP 65 housing & opal diffuser including, PVC flexible wire complete all as specified and diretced. 8 Each
31 31 M&L for PCC (1:2:4) type B1, using 20 mm graded stone aggregate as in roof kerbs /coping /bed plate and the like including weathering slightly or chamfered angle with necessary form work complete all as specified and directed. 3 Cum
32 32 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and directed. 235 RM
33 33 S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armoured power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 4 core laid in trenches complete all as specified and directed. 175 RM
34 34 Repairs/servicing of LT panel board incl welding of doors, painting, cleaning connecting with new copper wires of various sizes complete all as specified and directed. 2 Each job
35 35 Supply and fixing landscape lights / garden light fittings elegent yet minimalstic design acts as silent observer and giving lights, diffuser at the upper portion acts as beacon of path guidence in a landscape environment suitable for 240 volts 50 Hz AC Supply of capacity 8 watt LED including making connections and construction of foundation of size 150mm x 150mm x 200mm with PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) and fixing PVC pipes suitable dia inside concrete for fixing of incomming and outgoing cables etc complete all as specified and directed.\n 14 Each
36 36 S&F in replacement service cable 10 Sqmm twin core 1100 volts grade heavy duty cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular fiixed on poles/walls & connecting up complete all as specified and directed. 450 RM
37 37 S&F in replacement service cable 6 Sqmm twin core 1100 volts grade heavy duty cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular fiixed on poles/walls & connecting up complete all as specified and directed. 380 RM
38 38 S&F in replacement of 2 runs of PVC insulated 1.5 sqmm single core multistranded aluminium conductor cable and one run of 1 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length complete all as specified and directed. 450 RM
39 39 Cutting existing road/hardstand of any type by using crow bar chisel etc not exceeding 30 cm wide and not exceeding 60cm depth for laying GI pipe including making goo the surface by returning, filling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. \n 40 RM
40 40 Cutting and trimming of tree branches to clear the over head lines in the arc of HT/ LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site complete all as specified and directed by Engr-in-Charge. NOTE : All tools required for the job should be arranged by the contractor with in the overall cost quoted in the item. 200 Each Span
41 41 S&F in replacement LED lamp 7 Watts capacity B-22 base complete all as specified and directed. 145 Each
42 42 S&F in replacement LED lamp 40/45/50 Watts capacity B-22 base complete all as specified and directed. 120 Each
43 43 M&L for pin type insulator 100 mm height, 65 mm dia porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut, suitable for 1100 volt grade complete all as specified and as directed. 40 Each
44 44 Labour only for restringing of ACSR conductor any size/type complete all as specified and directed 5 Qtl
45 45 M&L for cross arm bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed 1 Qtl
46 46 Supply and Fixing ACSR conductor of any size on existing LT pole including copper binding or aluminium tap complete all as specified and directed. 1 Qtl
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail