Repairs , Maintenance And Servicing , Cleaning Of Different Types Of Ac Plant Ahu Units , Ducting Unit , Filter Unit Including All Type Of Electric Panels Under Ge ( U ) Bathinda At Bathinda Mil Stn, Bathinda Mil Station-Punjab

Military Engineer Services-MES has published Repairs , Maintenance And Servicing , Cleaning Of Different Types Of Ac Plant Ahu Units , Ducting Unit , Filter Unit Including All Type Of Electric Panels Under Ge ( U ) Bathinda At Bathinda Mil Stn. Submission Date for this Tender is 20-08-2020. Air Handling Unit Tenders in Bathinda Mil Station Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

24971414
Repairs , Maintenance And Servicing , Cleaning Of Different Types Of Ac Plant Ahu Units , Ducting Unit , Filter Unit Including All Type Of Electric Panels Under Ge ( U ) Bathinda At Bathinda Mil Stn
Open Tender
Indian
Punjab
Bathinda Mil Station
20-08-2020

Tender Details

Repairs , Maintenance And Servicing , Cleaning Of Different Types Of Ac Plant Ahu Units , Ducting Unit , Filter Unit Including All Type Of Electric Panels Under Ge ( U ) Bathinda At Bathinda Mil Stn

Key Value

Document Fees
INR 500 /-
EMD
INR 39400.0 /-
Tender Value
INR 19.70 Lakhs /-

BOQ Items

Name of Work : REPAIRS, MAINT AND SERVICING, CLEANING OF DIFFERENT TYPES OF AC PLANT AHU UNITS, DUCTING UNIT, FILTER UNIT INCLUDING ALL TYPE OF ELECTRIC PANELS UNDER GE (U) BATHINDA AT BATHINDA MIL STN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for dismantling of existing Air Handling Unit of any capacity , cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding / brazing wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 guage thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nuts, bolts, washers and other packing materials etc, with and including testing, commissioning of Air handling Unit at optimum efficiency complete all as directed. (Work lies in Restricted Area) 20 Each Job
2 2 M&L for cleaning inside surface of Air supply return/exhaust ducts all grills, dampers & diffusers of HVAC system by (NADCA certified Duct Cleaning Agency) using high power vacuum air compressor, robotic camera air hammer, special nozzle, air sweep with other required accessories giving/showing inspection of dust before and after cleaning of duct using colour video inspection all as directed by Engr-in-Charge. Note :- (a) The contractor shall make video recording of before and after cleaning and will submit for the purpose of payment. For the purpose of payment duct surface area only will be measured.\n(b) The contractor is responsible for any damage/breakage caused at the time of cleaning and the contractor will repair/replace the same without any extra cost to the Govt.\n(c) CD of cleaning process of duct shall be submitted by contractor before claiming of payment as an evidence. 30000 Sqft
3 3 Taking down old unserviceable air filter from AHU and S&F air filter of size 508mm X 508mm X 25.4mm HDPC of 5 micron complete all as specified and directed. 24 Each
4 4 Taking down old unserviceable Hepa air filter from AHU and S&F Hepa air filter of size 605mm X 605mm X 305 mm HDPC of 5 micron 99.97% complete all as specified and directed. 16 Each
5 5 Taking down old unserviceable Hepa air filter from AHU and S&F Hepa air filter of size 610mm X 210mm X 311 mm HDPC of 5 micron 99.97% complete all as specified and directed. 12 Each
6 6 Taking down old unserviceable pre air filter from AHU and S&F pre air filter of size 610mm X 508mm X 25.4 mm HDPC of 5 micron 99.97% complete all as specified and directed. 30 Each
7 7 Taking down old unserviceable pre air filter from AHU and S&F pre air filter of size 580mmX 465mm X 45 mm HDPC of 5 micron 99.97% complete all as specified and directed . 12 Each
8 8 Taking down old unserviceable pre air filter from AHU and S&F pre air filter of size 590mmX 570mm X 47 mm HDPC of 5 micron 99.97% complete all as specified and directed . 6 Each
9 9 Taking down old unserviceable pre air filter from AHU and S&F pre air filter of size 590mmX 410mm X 47 mm HDPC of 5 micron 99.97% complete all as specified and directed. 2 Each
10 10 Taking down old unserviceable pre air filter from AHU and S&F pre air filter of size 610mm X 610mm X 50 mm HDPC of 5 micron 99.97% complete all as specified and directed. 24 Each
11 11 Taking down old unserviceable pre air filter from AHU and S&F pre air filter of size 305mmX 610mm X 50 mm HDPC of 5 micron 99.97% complete all as specified and directed. 18 Each
12 12 Disconnecting the water sensor from chiller unit and S&F water sensor as per sample for chiller unit. 14 Each
13 13 M&L for Insulation of 20 mm dia MS pipe with PUF slab 30 mm thick with and including applying bituminous compound and GI cladding with 26 guage GI sheet complete. 30 RM
14 14 All per item No 13 above but of 32 mm dia. 40 RM
15 15 All per item No 13 above but of 40 mm dia. 80 RM
16 16 All per item No 13 above but of 50 mm dia. 40 RM
17 17 M&L in resplacement of insulation of 80 mm bore MS pipe with PUF slab 40 mm thick with and including applying bituminous compound and GI cladding with 26 guage GI sheet complete all as directed. 50 RM
18 18 All per item No 17 above but of 100 mm dia. 50 RM
19 19 All per item No 17 above but of 125 mm dia. 50 RM
20 20 All per item No 17 above but of 150 mm dia. 50 RM
21 21 All per item No 17 above but of 200 mm dia. 50 RM
22 22 S&F CI butterfly valve, ISI marked, PN - 1.6 pressure grade, having Nitrile/EPDM rubber lining, SS stem,CS/SS disc, lever operated type, of size 50 mm dia bore with hand wheel including all jointing material i.e, nuts, bolts, washers, packing materials etc, duly insulated and taking out of old unserviceable valve complete all as directed. 2 Each
23 23 All as per item No.22 above but bore size of 65 mm. 2 Each
24 24 All as per item No.22 above but bore size of 80 mm. 4 Each
25 25 All as per item No.22 above but bore size of 125 mm. 1 Each
26 26 All as per item No.22 above but bore size of 150 mm. 1 Each
27 27 S&F 150 mm bore dia CI non return valve, ISI marked, PN- 1.6, conforming to IS 5312 Part -I, both ends flanged, heavy duty, including packing materials, nuts, bolts, washer etc and testing complete including taking out of old U/S non return valve all as directed. Body Cover CI IS : 210, Gr. FG260. Body Rings - Bronge : IS 318 Gr. LTB2. Hinge Pin-SS ASTM A276 Type 410. Flange Drilling - IS 1538, Table 4 & 6. 1 Each
28 28 All as per item No.27 above but bore size of 200 mm. 2 Each
29 29 S&F replacement Poly-F Plus PB classical Belts of size B-29. Make Fenner/Dunlop. 15 Each
30 30 All as per item No. 29 above but B-41. 8 Each
31 31 All as per item No. 29 above but B-42. 4 Each
32 32 All as per item No. 29 above but B-56. 6 Each
33 33 All as per item No. 29 above but B-62. 8 Each
34 34 All as per item No. 29 above but B-66. 12 Each
35 35 All as per item No. 29 above but B-68. 30 Each
36 36 All as per item No. 29 above but B-69. 15 Each
37 37 All as per item No. 29 above but B-70. 15 Each
38 38 All as per item No. 29 above but B-77. 4 Each
39 39 All as per item No. 29 above but B-83. 18 Each
40 40 All as per item No. 29 above but B-102. 6 Each
41 41 All as per item No. 29 above but B-107. 6 Each
42 42 All as per item No. 29 above but B-117. 6 Each
43 43 S&F in replacement Poly-F Plus PB classical Belts of size A-26. Make Fenner/Dunlop 12 Each
44 44 All as per item No. 43 above but A-28. 12 Each
45 45 All as per item No. 43 above but A-31. 4 Each
46 46 All as per item No. 43 above but A-38. 4 Each
47 47 All as per item No. 43 above but A-51. 4 Each
48 48 All as per item No. 43 above but A-53. 4 Each
49 49 M&L for 50 mm bore gate valve cast copper alloy screwed down high pressure with crutch handle, screwed both ends, for Iron pipe including taking out of old unserviceable gate valve complete all as directed. 8 Each
50 50 All as per item No 49 here-in-above but size 40 mm bore. 8 Each
51 51 All as per item No 49 here-in-above but size 32 mm bore. 10 Each
52 52 All as per item No 49 here-in-above but size 25 mm bore. 11 Each
53 53 All as per item No 49 here-in-above but size 20 mm bore. 12 Each
54 54 M&L for CI pipe of 100 mm bore with spigot and socket end, centrifugally cast, class LA, ISI marked, laid in trenches/ on surface/ over masonry pillar and connection to old or new position complete all as directed. 12 RM
55 55 All as per item No 54 here-in-above but size 80 mm bore. 12 RM
56 56 M&L for dismantling of blower shaft of AHU of up to 10000 CFM capacity, by removing the belt and pulley, blower drum, and re-mentling the shaft and filling of metal at decayed portions including all welding, turning, polishing and other machine works required to make the shaft of required shape and size, as original, balancing the shaft and refitting in AHU including re-assembling the blower, pulley etc with and including replacement of new bearing of existing size, testing the AHU for satisfactory operation, complete all as directed. 5 Each Job
57 57 All as per item No. 56 here-in-before but for AHU above 10000 CFM but upto and including 20000 CFM capacity. 3 Each Job
58 58 M& L for superior quality canvas cloth with Zip, Max cross sectional area 1 sqm having depth not more than 50 cm with GI frame suitable to connect both AHU and duct including taking down old material all as per directed. 2 Each Job
59 59 M& L for superior quality canvas cloth with Zip, Max cross sectional area 4 sqm having depth not more than 75 cm with GI frame suitable to connect both AHU and duct including taking down of old material all as per directed. 2 Each Job
60 60 M&L for applying one coat of red oxide primer over steel/iron surfaces of pipes after preparing surface with help of emery paper etc removing rust, dust and old paints and making surfaces smooth for achieving better grip between surface and primer all as specified. 200 Sqm
61 61 M&L for applying one coat of synthetic enamelled paint as desired colour over a coat of red oxide primer on steel/iron surfaces of pipes after preparing surfaces with help of emery paper etc removing rust, dust and old paints and making surfaces smooth for achieving better grip between surface and primer all as specified. 200 Sqm
62 62 M&L for applying one coat of aluminium paint on steel/iron cable trays, Aquastic protection surfaces , aluminium pipe insulations etc after preparing surfaces with help of emery paper etc removing rust, dust and old paints and making surfaces smooth for achieving better grip between surface and primer all as specified. 500 Sqm
63 63 S&F in replacement of temperature gauge bottom connected, direct mounted type, of temperature range of 0 - 100°C or 32 - 212°F, including necessary welding complete all as directed.\nMake : H Guru/Fiebig/Anergy/Emerald 8 Each
64 64 S&F in repalcement of Pressure gauge dial type range between 0 to 12 kg/cm2 with siphon assembly with on/off knob including necessary welding cutting all as per directed. Make : H Guru/Fiebig/Anergy/Emerald 8 Each
65 65 S&F power contactor of 25 Amp, AC3 rating, 03 pole, with 2NO+2NC Aux Contacts, 415V, ML 1.5 including taking down unserviceable contactor and making all electric connection, complete all as directed. 2 Each
66 66 All as per srl item No 65 here-in-above but 32 Amps capacity ML 2. 2 Each
67 67 All as per srl item No 65 here-in-above but 40 Amps capacity ML 3. 2 Each
68 68 All as per srl item No 65 here-in-above but 32 Amps capacity MNX 32. 4 Each
69 69 All as per srl item No 65 here-in-above but 25 Amps capacity MNX 25. 5 Each
70 70 S&F over load relay range 17-25.5 Amps, with built in single phase preventer, direct / separate mounting on contactors, as required including taking down old relay and making all electric connection, complete all as directed.\nMake : L&T cat part No CS96356OODO/ Schneider Elect / Siemens / C&S / Legrand 2 Each
71 71 All as per srl item No 70 here-in-above but 8.5 to 12.5 Amps capacity.\nMake : L&T cat part No CS96355OOAO/ Schneider Elect / Siemens / C&S / Legrand 2 Each
72 72 All as per srl item No 70 here-in-above but 3.5 to 5.2 Amps capacity.\nMake : L&T cat part No CS96355OOSO/ Schneider Elect / Siemens / C&S / Legrand 2 Each
73 73 S&F over load relay MN2 range 20-33 Amps, with built in single phase preventer, direct / separate mounting on contactors, as required including taking down unserviceable relay and making all electric connection, complete all as directed.\nMake : L&T / Schneider Elect / Siemens / C&S / Legrand 2 Each
74 74 All as per srl item No 73 here-in-above but 14-23 Amps capacity. 2 Each
75 75 All as per srl item No 73 here-in-above but 4.5-7.5 Amps capacity. 2 Each
76 76 S&F in replacement of Digital volt meter of size 96mm x 96mm, three phase, class I, with inbuilt selector switch, complete all as directed. Make : Schneider Elect / Seimens / Conserve / L&T / Socomec 4 Each
77 77 S&F in replacement of Digital ammeter of size 96mm x 96mm, three phase, 5A, class I, with inbuilt selector switch, complete all as directed. Make : Schneider Elect / Seimens / Conserve / L&T / Socomec 4 Each
78 78 S&F in replacement of LED type indicator lamp of red/blue/green colour for phase indication, complete all as directed.\nMake : Siemens / Schneider Elect / L&T / Essbee / C&S 25 Each
79 79 S&F in replacement of push button, projecting head (push function) type, complete all as directed. Make : C&S / Converse / Salzer / Schneider Elect / BCH 5 Each
80 80 S&F in replacement, of MCB 63 Amp, TPN, 16 KA, 'C' Curve, complete all as directed. 3 Each
81 81 S&F in replacement, of MCCB 125 Amp, 3 pole, 16 KA, ICS = 100% ICU, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed. 3 Each
82 82 S&F in replacement, of MCCB 160-200 Amp, 3 pole, 36 KA, ICS = 100% ICU, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed. 3 Each
83 83 S&F in replacement, of MCCB 200-250 Amp, 3 pole, 36 KA, ICS = 100% ICU, with adjustable thermal magnetic setting alongwith Spreader terminals and phase barriers, complete all as directed. 2 Each
84 84 M&L in replacement, of PVC fins Box suitable for cooling tower from 05 to 40 TR capacity, FRP induced draft type (Model : CM-12), complete all as directed. Make : Mihir/Paharpur 100 Each
85 85 S&F Rotational moulded polyethylene, minimum three layers, water storage tanks (cylinderical vertical with closed top) 5000 litres capacity, hoisted and fixed in position with and including suitable size float valve and including all fittings and fixtures complete all as specified and directed. 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy