Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #24970112

Work Of Providing , Laying And Jointing Of Hdpe Pipe Line , Construction And Commissioning Of 1 No Tw In Village Khejrawas Under Jal Jeevan Mission With Material And 2 Years Of Defect Liability Period In Tehsil Phulera , District Jaipur .

Issued by Government Departments · Phulera, Rajasthan
Tender Value
18.03 Lakhs
Estimated cost
Bid Submission
30 Jul 2020
0 days left
EMD
36060
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Phulera → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Work Of Providing , Laying And Jointing Of Hdpe Pipe Line , Construction And Commissioning Of 1 No Tw In Village Khejrawas Under Jal Jeevan Mission With Material And 2 Years Of Defect Liability Period In Tehsil Phulera , District Jaipur .

BOQ

Name of Work: Work of Providing, Laying and Jointing of HDPE pipe line, Construction and Commissioning of 1 No TW in village Khejrawas under Jal Jeevan Mission with material and 2 years of defect liability period in Tehsil Phulera, District Jaipur.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soilsitem11035Cum
22Providing , laying and jointing of HDPE pipes with fusion joints in assorted length with specials etc and inter connection with existing /new pipe line including fixing of sluice valves and specials as per specifications including fixing of sluice valves and specials as per specification including preparation of bed properly, carting to site with all lead, cutting to pipe, sectional testing of pipe line as perBIS specification submitting completion drawing as per specification(excluding earthwork)item2
32.01110mm HDPE Pipe lineitem32500Mtr.
43P&F soft seated gate valve of DI D/F (Class PN-1,soft seated)resilient seated soft sealing gate valves (Sluice valve) with body bonnet of ductive cast iron of grade GGG40 SG 400/12 orGGG 50 SG 500/07 or equivalent grade as per IS 3896 part-I part-II1985 and subs net revision wedge fully rubber lined with EPDM and seals of NBR and the valves should be of vacum tight and 100% lead proofwith face dimensions as per BSS 5163-89/IS14846-2000/DIN 3202 F4 or equivalent including cost of joining material. All the valves should be with electrostatics power coating both inside and out side pocket less body passages should be drilled as per IS 1538 or as per specifications.item4
53.0180mmitem53Each
63.02100mmitem62Each
74Providing and Fixing of cast iran special including tail piece ( class 10 ) as per IS 5531:1988 specification as required. Upto size 300mm dia.item7400Kg
85Providing and fixing of cast iron double Non Returns valves IS 14846/2000 specifications (ISI marked) of PN-1 rating including cost of rubber flange gaskit and nut bolts complete as required for following sizes :item8
95.0180mmitem95Each
105.02100mmitem104Each
116Construction of tube-well 200 mm dia from ground levels and upto 100 mtr. Depth and above to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc., by percussion/ rotary, drilling method having minimum bore size of 445 mm and with gravel and packing as per IS:2800 (part 1 & 2), 1979 as amended up to date (the work includes the cost of gravel and its primary packing and packing during development, lowering of housing, strainer assembly pipes, with supply and wrapping of coir rope, wherever necessary, for arresting fine sand particles & Development of tubewell as per IS specifications using suitable compressor to give sand free water (minimum capacity 600 cfm and pressure 10.50 Kg./Sqcm). The work will include the development of tube well by specific Air Compressor but will not include cost of casing & strainer ppe. Work will be completed after obtaining sand free water.item1180Mtr
127Construction of tube well 200 mm dia upto 100 meter. depth in all types of rock by DTH System as per IS : 2800 (Part I & II) 1979 specification. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal bore of casing pipe.item12100Mtr
138Supply of ERW M.S. black casing pipe ISI marked (IS:4270/2001) of grade Fe 410 of following sizes at site of work. NB of pipe OD Thickness Mass kgs/mtr 200 219.00 5.4 28.46item1381Mtr
149Labour charges for making slots on blank pipes made of ERW M.S. Black pipe ISI marked of 200mm dia nominal bore of 5.4 mm thickness, size of slotting as per IS: 8110-1985.item1412Mtr
1510Supply & installation of 3 phase submersible motor pump sets five star rating (Make KSB/ KALAMA/ KRILOSKAR/ TEXMO OR B20 ISI marked (IS: 8034-2002) of approved make with required accessories including making connection suitable for tube well/DCB/ open well. The job includes lowering of riser pipe, GI pipe with rope, cables, installation of complete fitting & accessories, jointing of electrical cables up to switch board (excluding the cost of riser pipe, cables & rope). All labour for testing of submersible pump set and supply of water mains, complete in all respect. 142mm diameter submersible pump set shall have following HP rating, Phase, Head, minimum discharge respectively 7.5KW(10HP) and head above 120 mtritem1515KW
1611Providing and lowering in tube well ISI marked of GI pipe 'B' class (IS:1239 make) threaded and double flanged/ welded) on both ends and two number 25x3 mm flat welded on both ends between pipe and flange, rubber washer & nut, bolts etc. complete in all respect.50 mm diaitem16120RM
1712S&F tube well cover (for 200 mmdia pipe) of MS sheet 8 at top & 5 mm thick 100 mm wide around the edge so as to form a cap on the top end of casing pipe with GI nipple 45 cm long & two GI flange at both end in 80 mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be weld over top plate . Gi nipple having outside thread of size 1/2\"(for installation of pressure gauge) shall be provided & welded with GI 80 mm nipple near top plate nipple shall be provided with end plug) 200mm dia.item171Each
1813Supplying & fixing of finolax/Havells/L&T/plycab or approved by TC time to time, submersible cable(copper cable) suitable to run submersible pump set including making connection etc.item18
1913.01a) 3 core 4.0 mm2item19280RM
2014Providing and laying PVC insulated and PVC sheathed cables of 1.1 KV grade with aluminum conductor of IS 1554 category-l and approved mako of including excavation of 30 cm x 75 cm side trench as per IS-1255 15 cm thick under layer of sand II class brick covering, refilling earth In the remaining portion making necessary connection including testing etc. of required size 4 core (category-l). This includes all required Hardware material, termination end with suitable crimping lugs.item20
2114.01a) 4 core 16 Sqmmitem2130RM
2215Supply of electric control feeder panel comprising rewirable type 3 no. fuses, MCB (Make- L&T / SIEMENS/ GEC/CGL/C&S/ HAVELL or any any other make approved by technical committee RWSSMB time to time),fully automatic star delta stater (Make- L&T / SIEMENS/BSH/jyoti/ HAVELL / Crompton/ C&S or any any other make approved by technical committee RWSSMB time to time),, ampere meter, volt meter(Make- AE/ IMP/RISHABH/E&H or any any other make approved by technical committee RWSSMB time to time), phase preventer, suitable starting(L&T/NAPTUNEEDUCATE(NSL-10)/WEPCORE/UNITOR or any any other make approved by technical committee RWSSMB time to time),and running capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by JVVNL). a bakelite sheet of 12 mm thick shall be provided for installation of energy meter. All these equipments shall be housed by panel box made of 18 SWG ms sheet powder coating. Panel should be of minimum size 900 x 600 x 450 , with stand (made od angle iron of size 35x35x5 mm duly bolted / screwed with enclosure box having 4legs each leg's length 18\" and double door including inbuilt locking system. legsrunning with locking system. The legs should be embedded in M-15 cement concrete plateform . The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level . The operation of panel should be suitable for on 240 volt. AC Supply. The panel should have opening of suitable size infront of space for energy meter with glass for meter reading . Above 5 HP and up to 10 HP.item221Each
2316Supplying & installing 100 mm dia mtr sealed diaphragm bourdon type pressure gauge along with including all jointing materials range 0 to 10 Kg as per specification with safety cover.item231Each
2417Testing vertically of tube well by plumbing system and yield test and draw down test by pumping system as per IS:2800(Part-II)-1979 as amended upto date.item241Each
2518Supplying & packing P gravel suitable for slot sizes/mesh sizes as suggested in IS 2800 (part-I) 1991 with latest amendment.item2510Cum
2619Providing and laying GI Pipe A Class IS 1239 make for submersible cable external work 40 mm dia complete in all respectitem2612Mtr
2720Providing,installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box(sheet 16 SWG suitable with locking arrangement of lollowing diaitem27
2820.0150 mm diaitem281Each
2921Providing & fixing pump safety cage as per specifications or as directed by Engineer in chargeitem291Each
3022Providing & fixing of double flanged, CI body, ISI marked NRV of approved make of following sizesitem30
3122.0180mmitem311Each

AI Tender Summary

OUR REF NO 24970112
AUTHORITY Government Departments
TENDER VALUE 18.03 Lakhs
LAST DATE 30-07-2020
Authority
Authority Name Public Health Engineering Department
Work Description Work Of Providing , Laying And Jointing Of Hdpe Pipe Line , Construction And Commissioning Of 1 No Tw In Village Khejrawas Under Jal Jeevan Mission With Material And 2 Years Of Defect Liability Period In Tehsil Phulera , District Jaipur .
Basic Detail
Tender No NIT No 73-88/2020-21 DRD-3
Bidding Type Tender
Location
City Phulera
State Rajasthan
Key Dates
Publish Date 22 Jul 2020
Submission Date 30 Jul 2020
Open Date 31 Jul 2020
Finance
Tender Value 18.03 Lakhs
Tender Fee 500
EMD 36060
Exemption Not Available
Document List
TD74.pdf
Tendernotice_1.pdf
BOQ_339758.xls
A6BA65B0-662E-434C-BDCE-3A965A15E722.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 31, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

TD74.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_339758.xls

html

A6BA65B0-662E-434C-BDCE-3A965A15E722.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders