| 1 | 1 | Extra for cleaning the old surface with complete job | | 1036.81 | M2 |
|---|
| 2 | 2 | Providing 12mm cement plaster(1:6)with complete job(5.7.3) | | 142.25 | M2 |
|---|
| 3 | 3 | Providing 6mm cement plaster (1:4)in celling with complete job(5.7.6) | | 56.32 | M2 |
|---|
| 4 | 4 | Providing and applying white cement based putty of thickness 1.0mmof approved brand and manufacture over the plastered wall surface to prepare the surface even and smooth with complete job(13.8) | | 281.07 | M2 |
|---|
| 5 | 5 | Finishing walls with premium arylic smooth exterior paint with silicone additives of required shade new work (two or more coats applied @1.43 kg/10 sqm over priming coat of exterior primer applied @2.20 kg/10 sqm(13.4) | | 281.07 | M2 |
|---|
| 6 | 6 | Providing and applying plaster of perish putty of 2mm thickness over plastered surface to prepare the surface even and smooth with complete job(13.2) | | 755.74 | M2 |
|---|
| 7 | 7 | Providing two coat of oil bound distemper over a primer coat of cement primer over new surface with complete job(5.8.1) | | 755.74 | M2 |
|---|
| 8 | 8 | Providing primer and coat of red lead paint over steel surface with complete job(8.41) | | 35.55 | M2 |
|---|
| 9 | 9 | Prokiding two coat of synthetic enamel point over steel surface with complete job(8.45) | | 35.55 | M2 |
|---|
| 10 | 10 | Providing 19 mm thick water proof cement plaster (1:3)with complete job(5.7.15) | | 320.08 | M2 |
|---|
| 11 | 11 | Providing & laying APP(ATACTIC POLYPROPYLENE POLYMER) modified prefareable five layer 3 mm thick water proofing membrane,black finished reinforced with non –woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @0.40 litre/sqm(14.89) | | 352 | M2 |
|---|
| 12 | 12 | Providing 250 mm wide brick drain in cement mort(1:6) with av.150 mm clear depth and 250mm apron with complete job(5.10.35) | | 30 | Mtr |
|---|
| 13 | 13 | Making plinth protection 50 mm thick of cement concrete (1:3:6)over 75 mm bed by dry bricks ballast 40 mm nominal size well rammed and consolidatedand grounted with fine and including the top smooth.(4.1) | | 38.33 | M2 |
|---|
| 14 | 14 | Supplying,fitting and fixing 20 gaugeG.C.I sheet gate fitted on m.s.angle frame with complete job(5.29) | | 16.66 | M2 |
|---|
| 15 | 15 | Supplying,fitting and fixing 250x20x6mm | | 25 | Each |
|---|
| 16 | 16 | Dismanting patent stone flooring including stacking serviceable materials in countable stacks with complete job(5.10.4) | | 281.59 | M3 |
|---|
| 17 | 17 | Providing P.C.C(1:2:3) In foundation and plinth with complete job(5.32) | | 26.75 | M3 |
|---|
| 18 | 18 | Providing and laying double charge vitrified tiles in different size with water absorption less than 0.08% with complete job.600x600mm size(5.6.28) | | 394.22 | M2 |
|---|
| 19 | 19 | 80 mm thick C.C paver block of M-30 grade with approved color designcomplete job (91.2) | | 96.02 | M2 |
|---|
| 20 | 20 | Providing coarse clean sand in filling in foundation trenches or in plinth with complete job(5.1.10) | | 9.65 | M3 |
|---|
| 21 | 21 | 80 mm thick C.C paver block of M-30 grade with approved color design complete job(16.91.2) | | 92.94 | M2 |
|---|
| 22 | 22 | Providing coarse clean sand in filling in foundation trenches or in plinth with complete job | | 14.16 | M3 |
|---|
| 23 | 23 | Providing P.C.C (1:2:4)in foundation and plinth with complete job | | 2.14 | M3 |
|---|
| 24 | 24 | Add cost of RFT in paver block | | 1 | L.S |
|---|
| 25 | 25 | Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm FRPVC insulated copper conductor single core cable in surface /recessed PVC conduct,with plano type switch,phenolic laminelateed sheet , suitable size PVC/G.I. box as requIred | | 60 | p/p |
|---|
| 26 | 26 | Wiring for light /power plug with 2x4 sq.mm FRPVC insulated copper conductor single core cable in surface /recessed PVC conductor single core cable for loop earthing as required | | 45 | p/mtr |
|---|
| 27 | 27 | Supplying and fixing following piano tyoe switch/socket on the existing switch box/cover including connection required (1.24.1)+(1.24.4) | | 25 | p/each |
|---|
| 28 | 28 | Wiring for circuit /submain wiring along with the/ following size mPVC/ insulated copper conductor single core cable in surface/recessed PVC conductor single core cable fot lopp earthing as required (1.7.2) | | 90 | p/mtr |
|---|
| 29 | 29 | Wiring for circuit | | 80 | p/mtr |
|---|
| 30 | 30 | Electronic step fan regulator ,mini(1.23.10) | | 70 | p/each |
|---|
| 31 | 31 | Supplying and fixing suitable size G.I/PVC-box surface or in recess with phenalic liminated sheet cover in front including providing and and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch in connection painting etc as required(1.30) | | 5 | p/each |
|---|
| 32 | 32 | Supplying and fixing 3 pin 5 ams ceiling rose on the existing junction box/wooen including connection etc as required(1.34) | | 20 | p/each |
|---|
| 33 | 33 | Supplying of fixing batten/angle holder including connection etc as required (1.34) | | 25 | p/each |
|---|
| 34 | 34 | Supplying of ceiling fan48”(1200mm) bajaj/cg or any other approved make (p(64)of (2101) | | 20 | p/each |
|---|
| 35 | 35 | Installation testing and commissioning of ceolling fan including wiring the down rods of standard length (upto 30cm) with 1.559mm FR PVC insulated copper conductor single care cable etc as required (1.44) | | 20 | p/each |
|---|
| 36 | 36 | Supplying and fixing following way single pole neutral sheet MCB distriibution board 240 volts on surface/ recess complete with linned copper busbar neutral busbar earth bar din bar detachable gland plate with complete job (2.8.3) | | 3 | p/each |
|---|
| 37 | 37 | Supplying and fixing 6amps to 32 amps rating 240 volts “B” SERIES miniature circuit breaker suitable for lighting and other loads od following poles in the existing MCBDB complete with connection and commission etc(2.11.1) | | 10 | p/each |
|---|
| 38 | 38 | Supplying and fixing following rating double pole 240 volts in the existing MCBDB complete with connection testing and commission etc.(2.14.1) | | 3 | p/each |
|---|
| 39 | 39 | Providing and fixing following capacity double pole /TP/N sheet metal switch disconnector fuse unit in | | 4 | p/each |
|---|
| 40 | 40 | Laying of one number PVC insulated and PVC sheated/XLPE power cable of 1.1 kv grade of size not exceeding 25sq.mm direct in ground including excavation sand cushioning protective covering and refiffing the trench etc as required | | 30 | p/m |
|---|
| 41 | 41 | S/F 4x40 watt single box type tube light fitting[P(67)]226 | | 25 | P/each |
|---|
| 42 | 42 | S/F 36x40 watt tube light[p(66)]225 | | 25 | p/each |
|---|
| 43 | 43 | Earthing with G.I earth pipe 4.5 mtr long 40 mm dia including accessories and providing masonary enclose with cover plate having locking arrangement and watering pipe etc with charcoal and salt as require | | 2 | p/set |
|---|
| 44 | 44 | Supplying and fixing 85WG copper wire at 0.50 mtr below ground level for conductor earth electrode including soldering etc as required | | 25 | p/mtr |
|---|
| 45 | 45 | Carriage of material | | | |
|---|
| 46 | 46 | Bricks(1K+7P)km lead | | 1.98 | % |
|---|
| 47 | 47 | Sand (8km lead) | | 126.28 | M3 |
|---|
| 48 | 48 | Stone chips(22km lead) | | 85.35 | M3 |
|---|
| 49 | 49 | Stone metal (20 km lead) | | 1.71 | M3 |
|---|
| 50 | 50 | G.S.T | | 1.7164e+06 | % |
|---|
| 51 | 51 | Labour Cess | | 1.92237e+06 | % |
|---|