Providing Services For Attending Breakdowns And Shutdowns At 220Kv Substations And Lines Under Dgm T O And M-South For Two Years . , New Delhi-Delhi

Delhi Transco Limited has published Providing Services For Attending Breakdowns And Shutdowns At 220Kv Substations And Lines Under Dgm T O And M-South For Two Years . . Submission Date for this Tender is 10-08-2020. Machine Tools Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

24939939
Providing Services For Attending Breakdowns And Shutdowns At 220Kv Substations And Lines Under Dgm T O And M-South For Two Years .
Open Tender
Indian
Delhi
New Delhi
10-08-2020

Tender Details

Providing Services For Attending Breakdowns And Shutdowns At 220Kv Substations And Lines Under Dgm T O And M-South For Two Years . , Charges To Attend The B/Down & Emergency Work At A Particular Site By Providing Skilled B/Down Gang , Not Less Than Six Persons ( All T&P , & Vehicle To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv Circuit Breaker ( 3 Poles ) Including Removing Of Connected Jumpers/Clamps/Earth Connection Control Wiring Cables/Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv Ct/Pt/Cvt ( 1 Pole ) Including Removing Of Connected Jumpers/Clamps/Earth Connection Control Wiring Cables/Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv Isolator Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv La ( 1 Pole ) Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 66Kv/ 33 Kv Ct / Pt / Cvt Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 66Kv/ 33 Kv Cb Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 66 / 33 Kv Isolator Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv Circuit Breaker ( 3 Poles ) Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv Ct/Pt/Cvt ( 1 Pole ) Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv Isolator Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv La ( 1 Pole ) Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 66Kv/ 33 Kv Ct / Pt / Cvt Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 66Kv/ 33 Kv Cb Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 66 / 33 Kv Isolator Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Providing Gas Cutter With Operator For Attending Various Jobs At 220Kv S/Stn . / Linesp Incl . To & Fro Charges . , Providing Welding Machine With Welder For Attending Various Jobs At 220Kv S/Stn . / Lines Incl . To & Fro Charges . , Replace Main Top Bus-Bar , 220Kv/66Kv/33Kv Yard . , Hoisting Of Single/Double Tension Insulators String & Hardware Fitting And Fixing In Position Including Tightening Of Bolts & Nuts , Complete After Dismantling And Lowering Of Damaged Conductor/Disc Insulator String By Taking Tension Of Conductor On A Separate Arrangement Including Opening & Providing Of Jumpers . ( 220Kv Tension Tower ) . , Making Of Dead End ( Tension H/W ) Compression Joint . ( Zebra Conductor ) , Replacement Of Damaged Single/Double Suspension Insulator String By Re-Arranging With Good/New Disc Insulators/Polymer String , After Taking The Load Of Conductor On Alternate Arrangement Including Proper Clamping , Armouring Etc . As Per Site Requirement . ( 220Kv Tower ) , Replacement/Providing Dropper String On Angle Tower Including Fixing Of Suspension Clamp . ( 220Kv Tower ) . , Stringing Of Acsr Zebra Conductor Including Fixing Of Conductor Accessories , Such As Arcing Horn , Vibration Dampers Armour Rods , Tightening Of Clamps And Spacers Etc . , As Per Site Condition . , Re-Sagging Of Acsr Zebra Conductor Including Re-Fixing Of Proper Clamps & Hardware , Wherever Required . , Dismantling Of Acsr Zebra Conductor /Earth Wire Including Proper Rolling & Transportation Of Material Back To Store/Site . , Dismantling Of Earth Wire Including Proper Rolling & Transportation Of Material Back To Store/Site . Earth Wire 19/2 . 5 Mm ( Or 7/3 . 66Mm ) . , Jointing Of Acsr Zebra Conductor With Mid Span Joint Through Compression Joint Machine . , Jointing Of Earth Wire Mid Span Joint Through Compression Joint Machine . Earth Wire 19/2 . 5Mm ( Or 7/3 . 66 Mm ) . , Fixing Of Repair Sleeve On Acsr Zebra Conductor By Using Compression Machine . , Stringing Of 220 Kv Tower Earth Wire 19/2 . 5 Mm ( Or 7/3 . 66Mm ) Or Any Other Size Including Fixing Of Accessories & Necessary Hardware & Connection With Running Earth Wire , Earthing Arrangement For Continuity . ( 220Kv Lines ) , Re-Sagging Of 220 Kv Tower Earth Wire Including Tightening Of Suspension Clamps 19/2 . 5 Mm ( Or 7/3 . 66 Mm ) Or Any Other Size . ( 220Kv Lines ) . , Repairing Of Jumper / Replacing Of Conductor And Pg Clamps/ C Fire Wedge Connectors/ Compression Joint Or Providing Parallel Conductor On Acsr Zebra/Bersimis With Pg Clamps Etc . ( 220Kv Lines ) .

Key Value

Document Fees
Refer document
EMD
INR 11744679.0 /-
Tender Value
INR 1.17 Crore /-

BOQ Items

Name of Work: PROVIDING SERVICES FOR ATTENDING BREAKDOWNS AND SHUTDOWNS AT 220KV SUBSTATIONS & LINES UNDER DGM(T)O&M-SOUTH FOR TWO YEARS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Charges to attend the B/Down & Emergency work at a particular site by providing skilled B/Down gang, not less than six persons (all T&P, & vehicle to be arranged by contractor at his cost). item1 550 EA
2 2 Dismantling of 220 KV Circuit breaker (3 Poles) including removing of connected jumpers/clamps/earth connection control wiring cables/glands. etc.(All T&P & man power to be arranged by contractor at his cost). item2 40 EA
3 3 Dismantling of 220 KV CT/PT/CVT (1 Pole) including removing of connected jumpers/clamps/earth connection control wiring cables/glands. etc.(All T&P & man power to be arranged by contractor at his cost). item3 40 EA
4 4 Dismantling of 220 KV Isolator including removing of connected jumpers/ clamps/ earth connection control wiring cables/ glands. etc.(All T&P & man power to be arranged by contractor at his cost). item4 40 EA
5 5 Dismantling of 220 KV LA (1 Pole) including removing of connected jumpers/ clamps/ earth connection control wiring cables/ glands. etc.(All T&P & man power to be arranged by contractor at his cost). item5 40 EA
6 6 Dismantling of 66KV/ 33 KV CT / PT / CVT including removing of connected jumpers/ clamps/ earth connection control wiring cables/ glands. etc.(All T&P & man power to be arranged by contractor at his cost). item6 40 EA
7 7 Dismantling of 66KV/ 33 KV CB including removing of connected jumpers/ clamps/ earth connection control wiring cables/ glands. etc.(All T&P & man power to be arranged by contractor at his cost). item7 40 EA
8 8 Dismantling of 66 / 33 KV Isolator including removing of connected jumpers/ clamps/ earth connection control wiring cables/ glands. etc.(All T&P & man power to be arranged by contractor at his cost). item8 40 EA
9 9 Erection of the 220 KV Circuit breaker (3 Poles) including proper alignment operational check, replacement of control cable and gland requiring of control cable and gland requiring of control wire, re-fixing of earth connection required jumpering of the equipment to complete the job:(All T&P & man power to be arranged by contractor at his cost). item9 40 EA
10 10 Erection of the 220 KV CT/PT/CVT (1 Pole) including proper alignment operational check, replacement of control cable and gland requiring of control cable and gland requiring of control wire, re-fixing of earth connection required jumpering of the equipment to complete the job:(All T&P & man power to be arranged by contractor at his cost). item10 40 EA
11 11 Erection of the 220 KV Isolator including proper alignment operational check, replacement of control cable and gland requiring of control cable and gland requiring of control wire, re-fixing of earth connection required jumpering of the equipment to complete the job:(All T&P & man power to be arranged by contractor at his cost). item11 40 EA
12 12 Erection of the 220 KV LA (1 Pole) including proper alignment operational check, replacement of control cable and gland requiring of control cable and gland requiring of control wire, re-fixing of earth connection required jumpering of the equipment to complete the job:(All T&P & man power to be arranged by contractor at his cost). item12 40 EA
13 13 Erection of the 66KV/ 33 KV CT / PT / CVT including proper alignment operational check, replacement of control cable and gland requiring of control cable and gland requiring of control wire, re-fixing of earth connection required jumpering of the equipment to complete the job:(All T&P & man power to be arranged by contractor at his cost). item13 40 EA
14 14 Erection of the 66KV/ 33 KV CB including proper alignment operational check, replacement of control cable and gland requiring of control cable and gland requiring of control wire, re-fixing of earth connection required jumpering of the equipment to complete the job:(All T&P & man power to be arranged by contractor at his cost). item14 40 EA
15 15 Erection of the 66 / 33 KV Isolator including proper alignment operational check, replacement of control cable and gland requiring of control cable and gland requiring of control wire, re-fixing of earth connection required jumpering of the equipment to complete the job:(All T&P & man power to be arranged by contractor at his cost). item15 40 EA
16 16 Providing gas cutter with operator for attending various jobs at 220KV S/Stn. / Linesp incl. to & fro charges. item16 40 Day
17 17 Providing welding machine with welder for attending various jobs at 220KV S/Stn. / Lines incl. to & fro charges. item17 40 Day
18 18 Replace Main Top Bus-Bar, 220KV/66KV/33KV Yard. item18 4000 Mtr
19 19 Hoisting of Single/Double Tension insulators string & hardware fitting and fixing in position including tightening of bolts & nuts, complete after dismantling and lowering of damaged conductor/disc insulator string by taking tension of conductor on a separate arrangement including opening & providing of jumpers. (220KV tension tower). item19 100 EA
20 20 Making of dead end (Tension H/W) compression joint. (Zebra Conductor) item20 100 EA
21 21 Replacement of damaged Single/Double suspension insulator string by re-arranging with good/new disc insulators/Polymer string, after taking the load of conductor on alternate arrangement including proper clamping, armouring etc. as per site requirement. (220kV Tower) item21 100 EA
22 22 Replacement/providing dropper string on angle tower including fixing of suspension clamp. (220kV Tower). item22 40 EA
23 23 Stringing of ACSR Zebra Conductor including fixing of conductor accessories, such as arcing horn, vibration dampers armour rods, tightening of clamps and spacers etc., as per site condition. item23 20 KM
24 24 Re-sagging of ACSR Zebra Conductor including re-fixing of proper clamps & hardware, wherever required. item24 20 KM
25 25 Dismantling of ACSR Zebra Conductor /Earth wire including proper rolling & transportation of material back to store/site. item25 20 KM
26 26 Dismantling of Earth wire including proper rolling & transportation of material back to store/site. Earth wire 19/2.5 mm (or 7/3. 66mm). item26 10 KM
27 27 Jointing of ACSR Zebra Conductor with mid span joint through compression joint machine. item27 100 EA
28 28 Jointing of Earth wire mid span joint through compression joint machine. Earth wire 19/2.5mm (or 7/3.66 mm). item28 50 EA
29 29 Fixing of repair sleeve on ACSR Zebra Conductor by using compression machine. item29 50 EA
30 30 Stringing of 220 kV Tower Earth Wire 19/2.5 mm (or 7/3. 66mm) or any other size including fixing of accessories & necessary hardware & connection with running earth wire, earthing arrangement for continuity. (220KV Lines) item30 10 KM
31 31 Re-sagging of 220 kV Tower Earth Wire including tightening of suspension clamps 19/2.5 mm (or 7/3.66 mm) or any other size. (220KV Lines). item31 10 KM
32 32 Repairing of jumper / replacing of conductor and PG clamps/ C Fire wedge connectors/ compression joint or providing parallel conductor on ACSR zebra/Bersimis with PG clamps etc. (220kV lines). item32 100 EA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail