Tender For Undertaking Routines And Defect Rectification On Controls Onboard Ins Suvarna, NSRY,KARWAR-Karnataka

Indian Navy has published Tender For Undertaking Routines And Defect Rectification On Controls Onboard Ins Suvarna. Submission Date for this Tender is 07-08-2020. Tanks and Cylinders Tenders in NSRY,KARWAR Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

24930402
Tender For Undertaking Routines And Defect Rectification On Controls Onboard Ins Suvarna
Tender
Indian
Karnataka
Nsry,Karwar
07-08-2020

Tender Details

Tender For Undertaking Routines And Defect Rectification On Controls Onboard Ins Suvarna , Services , Following Instrumentation Of Both Main Engines Defective . To Be Repaired And Calibrated: - ( I ) Pressure Gauges ( 4 - 20 Ma ) Qty 10 Nos . ( Ii ) Temperature Gauges ( 4 - 20 Ma ) Qty 10 Nos . , Error - 20 Shaft Rpm Observed Between Both Main Engine Rpm To Its Designed Shaft Rpm Suspect Rpm Sensor And Associated Circuit Malfunctioning . Defect To Be Rectified And Synchronisation To Be Carried Out . , Engine Rpm On All Three Mode ( Local , Mcr Digital , Mcr Analog ) Showing Different Readings From One Another . Defect To Be Rectified . , Check And Calibrate Fuel Rack Indicators And Check Control Air Pressure With Fuel Rack Setting . Adjust Deviation If Any From Specified Curve , Check And Calibrate All Temperature Scanners , Check And Calibrate All Signal Conditioning Units ( Mss An Msa ) , Check Overload Curve On Engine With The Assistance Of Simulator , Recalibrate If Necessary . , Calibration Of Both Gear Box Temperature Scanner , Qty-02 Nos . , Stbd Gear Box Thrust Bearing No . 8 Temperature Nearing Alarm Limit ( 90 Deg C ) More Frequently Vis A Vis Port M / E On Same Regime . Sensor ( Rtd ) And Temperature Scanner To Be Calibrated And Defect To Be Rectified If Any . , Uncontrolled Roll Indication Observed While Deploying Stabilizer . Defect To Be Rectified . , Spares , Temperature Gauge 0-150C , Temperature Gauge 0-100C , Pressure Gauge 0-6 Bar , Pressure Gauge 0-10 Bar , Pressure Gauge 0-40 Bar , Pressure Gauge 0-60 Bar , Pressure Transmitter 0-6 Bar , Pressure Transmitter 0-10 Bar , Pressure Transmitter 0-40 Bar , Pressure Transmitter 0-60 Bar , Temperature Sensor For Tu Unit , Temperature Sensor For Tu Unit ( Pitch Setting Lot ) , Main Engine Exhaust Gas Temperature Sensor , Main Engine Exhaust Cold Junction Compensating Unit ( Cjcu ) , Main Engine Bearing Temp Sensor , Temperature Sensor For Gearbox Bearing Temperature , Gear Box Thrust Bearing Temp Sensor With 5 Way Junction Box , Plumber Block Bearing Temperature Sensor , Main Engine Speed Sensor , Shaft Speed Sensor , Fuel Rack Sensor , Gear Box Turning Gear Interlock Sensor , Main Engine Turning Gear Motor Pressure Engage / Disengage Indicator Switch , M / E Sump Lub Oil Switch , M / E Expansion Tank Level Switch , M / E Fuel Leak Off Switch , Fuel Control Handle Locked Switch , Micro Switch Belt For Engine Rpm Control ( Combinator Belt ) , Micro Switch Belt For Cpp Pitch Control ( Combinator Belt ) , Differential Pressure Switch For M / E , G / B & Cpp , Pressure Switch For M / E & Cpp , Pressure Switch For G / B , Pitch Angle Transmitter , Pitch Angle Indicator 10-0-10-Mcr , Pitch Angle Indicator 10-0-10-Bridge , Pitch Angle Indicator 10-0-10-Local , Bridge Wing Pitch Indicator 10-0-10 , Engine Rpm Indicator 0-1250 Rpm , Shaft Rpm Indicator 0-300 Rpm , Shaft Rpm Indicator Brige , Bridge Wing Shaft Rpm Indicator , Fuel Rack Indicator 0-40Mm , Temperature Indicator 0-150 C 4 , 5 Mtr . Capillary , Lcp-Fix Type Indicator Actuator , Mcr- Indicator Actuator - Fix Type , Mcr- Illuminated Push Button Actuator Maintained , Mcr- Illuminated Push Button Actuator Momentary , Mcr- Illuminated Push Button Actuator Transparent Cover , Pressure Regulator For Combination Actuator ( Control Air Valve ) , Logic Board- Logic Valve R301 , Logic Board- Logic Valve R501 , Logic Board- Logic Valve R502 , Logic Board- Logic Valve R461 , Logic Board- Logic Valve R231 , Logic Board-Solenoid Valve , Logic Board- Pressure Regulator , Logic Board- Pneumatic Pressure Switch , Lcp-Dcv Double Acting Valve , Lcp-Dcv Spring Loading Valve , Lcp-Solenoid Valve 3 / 2 Nc , Lcp-Solenoid Valve 3 / 2 No , , Lcp-Pneumatic Timer , Lcp-Closing Delay Valve , Lcp-3 / 2 Direction Control Valve ( Or Valve ) , Lcp-3 / 2 Direction Control Valve ( Not Valve ) , Glycerin Filled Pressure Gauges 2 1 / 2 Flush Mount , Ss Housing 0-10 Bar , Glycerin Filled Pressure Gauges 2 1 / 2 Flush Mount , Ss Housing 0-6 Bar , Glycerin Filled Pressure Gauges 2 1 / 2 Flush Mount , Ss Housing 0-60 Bar , Glycerin Filled Pressure Gauges 2 1 / 2 Flush Mount , Ss Housing 0-16 Bar , Glycerin Filled Pressure Gauges 4 Direct Mount , Ss Housing 0-10 Bar , Glycerin Filled Pressure Gauges 4 Direct Mount , Ss Housing 0-40 Bar , Glycerin Filled Pressure Gauges 4 Direct Mount , Ss Housing 0-6 Bar , Glycerin Filled Pressure Gauges 4 Surface Mount , Ss Housing 0-10Bar , Glycerin Filled Pressure Gauges 4 Surface Mount , Ss Housing 0-40 Bar , Glycerin Filled Pressure Gauges 4 Surface Mount , Ss Housing 0-4 Bar , Glycerin Filled Pressure Gauges 4 Surface Mount , Ss Housing 0-6 Bar

Key Value

Document Fees
Refer document
EMD
INR 190000.0 /-
Tender Value
Refer document
Disclaimer :