| 1 | 1 | Material and Labour for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for the following capacity of water cooler / refrigerator :- | 1 | | |
|---|
| 2 | 1.01 | (a) Water coolers 40 to 150 ltrs cooling capacity. | 2 | 22 | Job |
|---|
| 3 | 1.02 | (b) Refrigerator of any capacity. | 3 | 7 | Job |
|---|
| 4 | 1.03 | (c) Deep Freezers any capacity | 4 | 5 | Job |
|---|
| 5 | 2 | Supply and charging refrigerant gas F-12/R-22 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any complete all as specified and directed by Engr-in-Charge | 5 | | |
|---|
| 6 | 2.01 | (a) Water cooler 40 ltr cooling cap. | 6 | 15 | Each |
|---|
| 7 | 2.02 | (b) Water cooler 80 ltr cooling cap. | 7 | 5 | Each |
|---|
| 8 | 2.03 | (c) Water cooler 150 ltrs cooling cap | 8 | 5 | Each |
|---|
| 9 | 3 | Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. Make :Emerson,Kirloskar,Voltas | 9 | | |
|---|
| 10 | 3.01 | (a) Water coolers of capacity 165/185 liters. | 10 | 5 | Each |
|---|
| 11 | 3.02 | (b) Refrigerators of capacity 210 to 310 ltrs. | 11 | 5 | Each |
|---|
| 12 | 3.03 | (c) Deep freezers 200 to 300 ltrs capacity. | 12 | 1 | Each |
|---|
| 13 | 4 | Supply and replace starting relay suitable for :- Make : as per exiting make | 13 | | |
|---|
| 14 | 4.01 | (a) Water coolers any capacity | 14 | 10 | Each |
|---|
| 15 | 4.02 | (b) Refrigerator of any capacity. | 15 | 4 | Each |
|---|
| 16 | 4.03 | (c) Deep freezers of any capacity. | 16 | 3 | Each |
|---|
| 17 | 5 | Supply and replace thermostats of :-Make : as per exiting make | 17 | | |
|---|
| 18 | 5.01 | (a) Water coolers any capacity. | 18 | 10 | Each |
|---|
| 19 | 5.02 | (b) Refrigerator of any capacity. | 19 | 6 | Each |
|---|
| 20 | 5.03 | (c) Deep freezers of 200 to 425 ltrs capacity. | 20 | 3 | Each |
|---|
| 21 | 6 | Preparation of old painted surfaces of the following appliances and spray painting with two coats of synthetic enamel paint all as directed by Engr-in-Charge for :- | 21 | | |
|---|
| 22 | 6.01 | (a) Water coolers any capacity. | 22 | 10 | Job |
|---|
| 23 | 6.02 | (b) Refrigerators of any capacity. | 23 | 4 | Job |
|---|
| 24 | 7 | Supply and replace condenser unit of the following appliances including making of all connections as specified and directed by Engr-in-Charge. Make : as per exiting make | 24 | | |
|---|
| 25 | 7.01 | (a) Water coolers 40/60 ltrs capacity. | 25 | 8 | Each |
|---|
| 26 | 7.02 | (b) Refrigerator of 165 to 195 ltrs capacity. | 26 | 3 | Each |
|---|
| 27 | 7.03 | (c) Deep freezers of 200 to 300 ltrs capacity. | 27 | 1 | Each |
|---|
| 28 | 8 | Supply and replace cooling coil of :- | 28 | | |
|---|
| 29 | 8.01 | (a) Water coolers 40/60 ltrs capacity. | 29 | 3 | Job |
|---|
| 30 | 8.02 | (b) Refrigerator of 165 to 185 ltrs capacity. | 30 | 2 | Job |
|---|
| 31 | 9 | Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity. | 31 | 4 | Each |
|---|
| 32 | 10 | Supply and replace overload protector of :-Make : as per exiting make | 32 | | |
|---|
| 33 | 10.01 | (a) Water coolers/ Refrigarator upto 150 ltrs cooling capacity. | 33 | 10 | Each |
|---|
| 34 | 10.02 | (b) Deep freezers of upto 425 ltrs capacity. | 34 | 2 | Each |
|---|
| 35 | 11 | Supply and replace ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule Make : Leader, Jindal | 35 | | |
|---|
| 36 | 11.01 | (a) 15mm dia | 36 | 4 | Each |
|---|
| 37 | 11.02 | (b) 20mm dia | 37 | 2 | Each |
|---|
| 38 | 12 | Supply and fix PVC insulated and overall PVC sheathed circuler flexible 3 core 4 sqmm copper conductor cable including disconnecting and removal of old cable . Make: Flasa / Findese | 38 | 25 | RM |
|---|
| 39 | 13 | Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for :-Make : as per exiting make | 39 | | |
|---|
| 40 | 13.01 | (a) Water coolers of any make and cap 40 to 150 ltrs capacity. | 40 | 4 | Each |
|---|
| 41 | 13.02 | (b) Deep freezers of any make & cap 200 to 300 ltrs capacity. | 41 | 2 | Each |
|---|
| 42 | 14 | Dismantling and removing of defective burnt motor from unit and rewinding the motor with super enamel copper winding wire including replacement of worn out motor bearing, refixing and testing all as deirceted by Engr-in-Charge for the following appliances:-:-Make : as per exiting make | 42 | | |
|---|
| 43 | 14.01 | (a) Water coolers any make and cap 40 to 150 ltrs capacity. | 43 | 6 | job |
|---|
| 44 | 14.02 | (b) Deep freezer of any make of 200 to 425 ltrs capacity. | 44 | 2 | job |
|---|
| 45 | 15 | M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-(Note : Above second floor contractor will arrange crain / scaffolding with safety device) | 45 | | |
|---|
| 46 | 15.01 | (a) Window type room air conditioners of capacity 1.5 Ton cap. | 46 | 9 | Job |
|---|
| 47 | 15.02 | (b) Split type AC 1.5/2 Ton capacity. | 47 | 110 | Job |
|---|
| 48 | 16 | Supply and charging refrigerant gas R-22/R-32 up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed by Engr-in-Charge. Make Paragon,Mefron (Note: Above second floor contractor will arrange crain / scaffolding with safety device) | 48 | | |
|---|
| 49 | 16.01 | (a) Window type room air conditioners of capacity 1.5 Ton. | 49 | 7 | Each |
|---|
| 50 | 16.02 | (b) Split type AC 1.5/2.0 Ton capacity | 50 | 92 | Each |
|---|
| 51 | 17 | Preparation of old painted surfaces of the following appliances, painting with two coats of synthetic enamel paint by spraying as directed by Engr-in-Charge for :- (Note: Above second floor contractor will arrange crain / scaffolding with safety device)\nMake : Asian Paint,Berger,Asian Paint | 51 | | |
|---|
| 52 | 17.01 | (a) Window type room air conditioners of capacity 1/1.5 Ton cap. | 52 | 5 | Job |
|---|
| 53 | 17.02 | (b) Split type AC 1.5/2 Ton Capacity. | 53 | 58 | Job |
|---|
| 54 | 18 | Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. (Note : Above second floor contractor will arrange crain / scaffolding with safety device)\nMake : Emerson,Kirloskar,LG | 54 | | |
|---|
| 55 | 18.01 | (a) Window type air conditioners of capacity 1.5 Ton. | 55 | 3 | Each |
|---|
| 56 | 18.02 | (b) Split type AC 1.5/2.0 Ton capacity. | 56 | 28 | Each |
|---|
| 57 | 19 | Supply and replace capacitors of the following capacities for ACs Make :Siemens,epcos | 57 | | |
|---|
| 58 | 19.01 | (a) 4/6 Mfd | 58 | 90 | Each |
|---|
| 59 | 19.02 | (b) 10 Mfd | 59 | 80 | Each |
|---|
| 60 | 19.03 | (c) 36 Mfd | 60 | 70 | Each |
|---|
| 61 | 19.04 | (d) 80/100 Mfd | 61 | 70 | Each |
|---|
| 62 | 19.05 | (f) 45+6 Mfd Seven Pin | 62 | 65 | Each |
|---|
| 63 | 20 | Supply and replace selector switch complete with knob of compatible size and model for window type Acs. Make Siemens ,L&T,Annapooma | 63 | 40 | Each |
|---|
| 64 | 21 | Supply and replace starting relay suitable for :- | 64 | | |
|---|
| 65 | 21.01 | (a) Window type room air conditioners of capacity 1/1.5 Ton cap. | 65 | 4 | Each |
|---|
| 66 | 21.02 | (b) Split type AC 1.5/2 Ton capacity | 66 | 65 | Each |
|---|
| 67 | 22 | Supply and replace thermostats of :- Make Danfoss,Annapooma | 67 | | |
|---|
| 68 | 22.01 | (a) Window type room air conditioners of capacity 1/1.5 Ton cap. | 68 | 3 | Each |
|---|
| 69 | 22.02 | (b) Split type AC 1.5/2 Ton capacity. | 69 | 65 | Each |
|---|
| 70 | 23 | Supply and replace oeverload protector of :- Make Usha,Annapooma | 70 | | |
|---|
| 71 | 23.01 | (a) Window type room air conditioners of capacity 1/1.5 Ton cap. | 71 | 3 | Each |
|---|
| 72 | 23.02 | (b) Split type AC 1.5/2 Ton capacity. | 72 | 60 | Each |
|---|
| 73 | 24 | Supply and replace condenser unit make of copper of the following appliances including making of all connections as specified and directed by Engr-in-Charge Make :.LG,Voltas, Whirpool | 73 | | |
|---|
| 74 | 24.01 | (a) Window type room air conditioners of capacity 1/1.5 Ton capacity. | 74 | 3 | Each |
|---|
| 75 | 24.02 | (b) Split type AC 1.5/2 Ton capacity. | 75 | 32 | Each |
|---|
| 76 | 25 | Supply and replace of evaporator coil :- | 76 | | |
|---|
| 77 | 25.01 | (a) Window type room air conditioners of capacity 1.5 Ton cap. | 77 | 2 | Each |
|---|
| 78 | 25.02 | (b) Split type AC 1.5/2 Ton capacity. | 78 | 32 | Each |
|---|
| 79 | 26 | Supply and replace metal clad/sheet metal plug and socket with a 2 pin and earth plug and 20 Amps SP MCB complete including making all connections. Make :.Anchor,Schenider | 79 | 25 | Each |
|---|
| 80 | 27 | Supply and replace MCB SP 5 to 30 Amps 250 Volts. Make Legrand,L&T,C&S | 80 | 15 | Each |
|---|
| 81 | 28 | Supply and replace contact unit of split type air conditioning of 1.5/2 Ton cap model 3100-150-1961C or equivalent. | 81 | 36 | Each |
|---|
| 82 | 29 | Supply and replace internal wiring but complete suitable for :- | 82 | | |
|---|
| 83 | 29.01 | (a) Window type room air conditioners of capacity 1/1.5 Ton cap. | 83 | 3 | Job |
|---|
| 84 | 29.02 | (b) Split type AC of any make and capacity 1.5/2ton. | 84 | 28 | Job |
|---|
| 85 | 30 | Dismantling and removing of defective burnt motor from unit and rewinding the motor with enamel copper winding wire incl replacement of worn - out motor bearing ,refixing and testing all as directed for the following;- | 85 | | |
|---|
| 86 | 30.01 | (a) Window type AC of any make capacity 1/1.5 Ton cap. | 86 | 3 | Job |
|---|
| 87 | 30.02 | (b) Split type AC of any make and capacity 1.5/2 ton. | 87 | 34 | Job |
|---|
| 88 | 31 | Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for :- Make Crompton,Greaves | 88 | | |
|---|
| 89 | 31.01 | (a) Window type AC of any make capacity 1/1.5 Ton cap. | 89 | 2 | Each |
|---|
| 90 | 31.02 | (b) Split type AC of any make and capacity 1.5/2 ton. | 90 | 28 | Each |
|---|
| 91 | 32 | Supply and fix Air fillter suitable for 1.5/2.0 ton split type AC of any make | 91 | 48 | Each |
|---|
| 92 | 33 | Supply and fix insulation for copper tubes of split type AC units,insulation type superion of size 3/8\"diameter | 92 | 45 | RM |
|---|
| 93 | 34 | Supply and fix insulation for copper tubes of split type AC units,insulation type superion of size 5/8\"diameter | 93 | 45 | RM |
|---|
| 94 | 35 | Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8\" diameter | 94 | 45 | RM |
|---|
| 95 | 36 | Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8\" diameter | 95 | 45 | RM |
|---|
| 96 | 37 | Supply and fix PCB cercuit board complte suitable for 1.5/2.0 ton capacity split type air conditioner Make LG ,Voltas,Whirpool | 96 | 33 | Each |
|---|
| 97 | 38 | Supply and fix in repair indoor cooling unit with rotary fan suitable for 1.5 ton Split AC . Make LG ,Voltas,Samsung | 97 | 8 | Each |
|---|
| 98 | 39 | Supply and fix in repair indoor cooling unit with rotary fan suitable for 2 ton Split AC . Make LG ,Voltas,Samsung | 98 | 4 | Each |
|---|
| 99 | 40 | Supply and fix in repair outdoor unit with rotary fan suitable for 1.5 ton Split AC . Make LG ,Voltas,Samsung | 99 | 4 | Each |
|---|
| 100 | 41 | Supply and fix in repair outdoor unit with rotary fan suitable for 2 ton Split AC . Make LG ,Voltas,Samsung | 100 | 4 | Each |
|---|
| 101 | 42 | Supply and fix in repair remote of any size and capacity of split AC. Make: as per existing make. | 101 | 26 | Each |
|---|
| 102 | 43 | Supply and fix in repair Voltage stabilizer Capacity of 5KVA of range 130V to 180V suitable for up to 2Ton split AC. Make: V-Guard/Micro Tec. | 102 | 18 | Each |
|---|