Public Works Department-PWD has published Construction Of Circular Rcc Water Reservoir In/C Pump House. Submission Date for this Tender is 07-08-2020. Reservoir Tenders in Dharmanagar Tripura. Bidders can get complete Tender details and download the document.
Name of Work: JJM Scheme in North Tripura District during the year 2020-21/ Construction of Innovative water supply scheme by amalgamations of 4 nos SBDTW followed by clear water reservoir (20,000 gallon)/ SH. Construction of Circular RCC Water Reservoir in/c Pump House, providing & installation of Pump Motor with all accessories and commissioning of the scheme and allied works within the jurisdiction of DWS DIVISION, DHARMANAGAR/ Gr-VI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001170 | 500 | sqm |
2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. \n - All kinds of soil | BI01010001010000000000000515BI0100001171 | 300 | cum |
3 | 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. \n-All kinds of soil | BI01010001010000000000000515BI0100001172 | 61.67 | cum |
4 | 4 | Supplying and filling in plinth, under floor, foundations etc. With sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. | BI01010001010000000000000515BI0100001173 | 6.8 | cum |
5 | 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering –\n-All work upto plinth level:\ni) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001174 | 6.8 | cum |
6 | 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-\n-All work upto plinth level:\ni) 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001175 | 16.34 | cum |
7 | 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-\ni) 1:1:2 ( 1 Cement: 1fine sand : 2 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001176 | 13.39 | cum |
8 | 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-\n1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001177 | 13.55 | cum |
9 | 9 | Centering shuttering including struttings, propping etc. and removal of form work for: | BI01010001010000000000000515BI0100001178 | ||
10 | 9.01 | Foundations, footings, bases for columns etc. for mass\nconcrete with steel formwork | BI01010001010000000000000515BI0100001179 | 8.16 | sqm |
11 | 9.02 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply | BI01010001010000000000000515BI0100001180 | 118.55 | sqm |
12 | 9.03 | Suspended floors, roofs, landings, balconies and access\nplatform with 12 mm thick shuttering ply | BI01010001010000000000000515BI0100001181 | 47.49 | sqm |
13 | 9.04 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply | BI01010001010000000000000515BI0100001182 | 58.86 | sqm |
14 | 10 | Reinforcement for R.C.C. work including straightening,\ncutting, bending, placing in position and binding all\ncomplete upto plinth level.\ni) Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars | BI01010001010000000000000515BI0100001183 | 6491.4 | kg |
15 | 11 | Half brick masonry work with first class bricks in\nsuperstructure upto floor five level including cost of\nall materials as required complete:-\ni) In cement mortar 1:4 ( 1 cement : 4 fine sand ). | BI01010001010000000000000515BI0100001184 | 42.45 | sqm |
16 | 12 | 6 mm cement plaster of mix :\nCement mortar 1 : 4 (1 cement : 4 fine sand)\n | BI01010001010000000000000515BI0100001185 | 323.84 | sqm |
17 | 13 | 12 mm cement plaster of mix\nCement mortar 1 : 4 (1 cement : 4 fine sand)\n | BI01010001010000000000000515BI0100001186 | 42.45 | sqm |
18 | 14 | 15 mm cement plaster on the rough side of single or\nhalf brick wall of mix:\nCement mortar 1 : 4 (1 cement : 4 fine sand)\n | BI01010001010000000000000515BI0100001187 | 42.45 | sqm |
19 | 15 | Neat cement punning. | BI01010001010000000000000515BI0100001188 | 294.18 | sqm |
20 | 16 | Providing and fixing 1mm thick M.S. sheet door with\nframe of 40x40x6mm angle iron and 3mm M.S. gusset\nplates at the junctions and corners, & with cleats with\nbolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-\ni) Using M.S. angels 40x40x6 mm for diagonal braces. | BI01010001010000000000000515BI0100001189 | 5.55 | sqm |
21 | 17 | Painting with synthetic enamel paint of approved brand\nand manufacture to give an even shade [Payment shall\nbe made after submission of Test Certificate issued by\nthe Manufacturer]:\n12.47.1 Two or more coats on new work | BI01010001010000000000000515BI0100001190 | 23.45 | sqm |
22 | 18 | Providing structural steel work riveted, bolted or welded\nin built up sections, trusses and framed work, including\ncutting, hoisting, fixing in position and applying a\npriming coat of approved steel primer all complete as\nrequired. | BI01010001010000000000000515BI0100001191 | 910 | sqm |
23 | 19 | Providing and placing of G.I. pipe over the pump house on top portion of the R.C.C. column as per specification and the direction of the Engineer-in-charge.\ni. 150 mm dia | BI01010001010000000000000515BI0100001192 | 5.55 | mtr. |
24 | 20 | Applying one coat of water thinnable cement primer of\napproved brand and manufacturer on wall surface\ncomplete.\nWater thinnable cement primer | BI01010001010000000000000515BI0100001193 | 112.93 | sqm |
25 | 21 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] | BI01010001010000000000000515BI0100001194 | 112.93 | sqm |
26 | 22 | Making plinth protection 50mm thick of cement\nconcrete 1:3:6 (1 cement : 3 fine sand : 6 graded well\nburnt brick aggregate 20 mm nominal size) over\n75mm bed of dry brick ballast 40mm nominal size\nwell rammed and consolidated and grouted with fine\nsand including finishing the top smooth.\n | BI01010001010000000000000515BI0100001195 | 12.71 | sqm |
27 | 23 | Lettering with black Japan paint of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. | BI01010001010000000000000515BI0100001196 | 1000 | per letter per cm height |
28 | 24 | Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge.. | BI01010001010000000000000515BI0100001197 | 1 | Nos |
29 | 25 | Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge.\ni) 16 sqmm | BI01010001010000000000000515BI0100001198 | 30 | mtr. |
30 | 26 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.\nii) 35 HP/26 kw Relay range within 20-32 + 10% | BI01010001010000000000000515BI0100001199 | 1 | Nos |
31 | 27 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge.\ni) 100 amps | BI01010001010000000000000515BI0100001200 | 1 | No. |
32 | 28 | Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge.\nIv) 63-80 Amps | BI01010001010000000000000515BI0100001201 | 1 | No. |
33 | 29 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001202 | 3 | Nos |
34 | 30 | Providing and fitting fixing of moving iron type, Range 0-100/0200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001203 | 3 | Nos |
35 | 31 | Providing and fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001204 | 1 | Job |
36 | 32 | Providing and fitting fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge.\n i). 5-15 kVAr 440 V | BI01010001010000000000000515BI0100001205 | 1 | Job |
37 | 33 | Providing earthing with perforated 40 mm dia G.I. pipe (Medium class) ( 12 mm dia perforation ) , laying of 4 mm dia GI wire from earth electrode to panel, including excavating hole of 600 mm dia and refilling with Salt and Charcoal / coke in alternate layers of 300 mm , as per standard specification and direction of the Engineer-in-charge.\nii) for 3-phase connection with 4.00 mtr. Long G.I. pipe | BI01010001010000000000000515BI0100001206 | 1 | Nos |
38 | 34 | Providing & installation of 76.00 mtr head water lubricated submerssible pump with 3 Ph , 415 VAC motor with star delta connection along with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required upto the depth of 6.10 mtr (maximum) by GI pipe ( conforming to IS : 1239 medium class ) with tailpiece as required welded with GI flange in/c providing fitting fixing by necessary rubber washer, nuts & bolts, MS safety clamp etc. as per required size and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run as per direction of the Engineer-in-charge (each pump with motor shall consist of stainless steel impeller conforming to relevant BIS code. pump make : Duke/KSB/WPIL/Texmo/CRI ) (Pumpset, cable, G.I. pipe of medium class for column assembly etc. will be supplied by the agency at his cost and for main switch / starter payment will be done separately).\n\nii) 5000 / 7500 GPH capacity with 80 mm dia G.I. pipe and 10 mm thick GI flange | BI01010001010000000000000515BI0100001207 | 2 | Nos |
39 | 35 | Providing and fitting fixing Digital 3 Phase FASD controller (L&T /BCH/HAVELS/Siemens make or as per relevant IS specification) with suitable relay range 9-14A/11-18A/20- 32A/30-50A. With auto start switch and single phase preventer in built, LED indicator for motor off-on, amps meter, voltmeter with selector switch, controller having k-curve 3 pole MCB, iprotector to protect from dry run, under voltage fault, over voltage fault, phase reversal fault etc. complete with successful trial run as per specification and direction of the\ni) For 10/12 HP submerssible motor | BI01010001010000000000000515BI0100001208 | 1 | No |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail