Scope Of Work:Supply, Warranty For 2 Years Including Warranty Maintenance And Comprehensive Annual Maintenance Contract For 6 Years After Completion Of Warranty. ( In Blocks Of 2 Years) Supply Of 2Kg Co2 Type Fire Extinguisherconfirming To Is 15683:2006 , Master Control Facility, Salagame Road, Hassan-Karnataka

Department Of Space has published Scope Of Work:Supply, Warranty For 2 Years Including Warranty Maintenance And Comprehensive Annual Maintenance Contract For 6 Years After Completion Of Warranty. ( In Blocks Of 2 Years) Supply Of 2Kg Co2 Type Fire Extinguisherconfirming To Is 15683:2006 . Submission Date for this Tender is 10-08-2020. Tool kit Tenders in Master Control Facility, Salagame Road, Hassan Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

24857779
Scope Of Work:Supply, Warranty For 2 Years Including Warranty Maintenance And Comprehensive Annual Maintenance Contract For 6 Years After Completion Of Warranty. ( In Blocks Of 2 Years) Supply Of 2Kg Co2 Type Fire Extinguisherconfirming To Is 15683:2006
Tender
Indian
Karnataka
Master Control Facility, Salagame Road, Hassan
10-08-2020

Tender Details

Scope Of Work:Supply, Warranty For 2 Years Including Warranty Maintenance And Comprehensive Annual Maintenance Contract For 6 Years After Completion Of Warranty. ( In Blocks Of 2 Years ) Supply Of 2Kg Co2 Type Fire Extinguisherconfirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Capacity: 2 Kg. Bis Marking Required With Cm / L No. Rechargeablefire Rating: 8B.Discharge Range – 1 Meter Or More For Class B Minimum Discharge Time: 8 Min. Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band: Black. Supply Of 3 Kg Co2 Type Fire Extinguisherconfirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Capacity: 3 Kg. Bis Marking Required With Cm / L No. Rechargeablefire Rating: 13B.Discharge Range – 1 Meter Or More For Class Minimum Discharge Time: 8 Min. Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Black. Supply Of 4.5 Kg Co2 Type Fire Extinguisherconfirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Capacity: 4.5 Kg. Bis Marking Required With Cm / L No. Rechargeablefire Rating: 21B.Discharge Range – 2 Meter Or More For Class B Minimum Discharge Time: 8 Min. Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Black. Supply Of 6.5 Kg Co2 Type Fire Extinguisherconfirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Capacity: 6.5 Kg. Bis Marking Required With Cm / L No. Rechargeablefire Rating: 21B.Discharge Range – 2 Meter Or More For Class B Minimum Discharge Time: 8 Min. Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Black. Supply Of 5 Kg Abc Type Fire Extinguisherconfirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Bis Marking Required With Cm / L No. Rechargeabletype: Stored Pressure.Operating Pressure : 15-19 Bar. Shall Have Integrated Pressure Gauge. Extinguishing Media: Powder Based Abccapacity: 5 Kg. Minimum Discharge Time: 8 Seconds. Expellant Media : N2 Based. Fire Rating: 21 B. Discharge Range – 2 Meter Or More For Class B Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Blue. Supply Of 5 Kg Dcp Type Fire Extinguisherconfirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Bis Marking Required With Cm / L No. Rechargeabletype: Stored Pressure.Operating Pressure : 15-19 Bar. Shall Have Integrated Pressure Gauge. Extinguishing Media: Powder Based Bccapacity: 5 Kg. Minimum Discharge Time: 8 Seconds. Expellant Media: N2 Based. Fire Rating: 21 B. Discharge Range – 2 Meter Or More For Class B Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Blue. Supply Of 9 Liter Stored Pressure Type Afff Foam Fire Extinguisherconfirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Bis Marking Required With Cm / L No. Rechargeablestored Pressureoperating Pressure : 15-19 Bar. Shall Have Integrated Pressure Gauge. Capacity: 9 Liters. Extinguishing Media: Afff ( Aqueous Film Forming Foam ) Expellant Media: N2 Based. Minimum Effective Discharge Time In Seconds: 8 Sec. Fire Rating: 21B.Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Yellow. Supply Of 9-Liter Gas Cartridge Type Afff Foam 09-Liter Extinguisher. Confirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Bis Marking Required With Cm / L No. Rechargeabletype: Gas Cartridge Type. Capacity: 9 Liters. Extinguishing Media: Afff ( Aqueous Film Forming Foam ) Expellant Media: Co2 Minimum Effective Discharge Time In Seconds: 8 Sec. Fire Rating: 21B.Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Yellow. Supply Of 45 / 50-Liter Gas Cartridge Type Afff Foam Extinguisher. Confirming To Is 15683:2006 With Latest Amendments Up To The Date Of Quote. Bis Marking Required With Cm / L No. Rechargeabletype: Gas Cartridge Type. Capacity: 45 / 50 Liters. Extinguishing Media: Afff ( Aqueous Film Forming Foam ) Expellant Media: Co2 Minimum Effective Discharge Time In Seconds: 40 Sec. Fire Rating: 34B.Operating Temperature :50 – 550 C Color Of Extinguisher Body: Red.Color Of Identification Band : Yellow. Supply Of Low Pressure Water Mist & Cafs Type: Portable Back Pack Suitable For: Class A, Class B And Electrical Fires Up To A Voltage Of 1000 V. Operating Pressure: 05 – 15 Bar ( For Low Pressure System ) , Capacity: 9 Liters. Fire Rating: 27 A, 233B.Expellant : Compressed Air.Extinguishing Media : Water And Afff.Water Cylinder Construction: Composite With Pet Liner / Aluminum / Stainless Steel Ss 316, Safety Valve: Shall Be Provided With Setting As 1.5 Times The Operating Pressure. Air Bottle Capacity: 4.7 Liters At 300 Bar. Air Bottle Construction: Peso Approved Carbon Composite ( Copy Of Peso Approval Certificate Shall Be Provided And Sl. No In The Marking And Certificate Shall Match ) . Air Bottle Test Pressure: 450 Bars. Weight Of The Complete Filled System With Gun Shall Not Be More Than 28 Kgs. Weight Of The Gun Shall Not Be More Than 2 Kgs. Nozzle Modes: Jet And Spray. Lancing Distance In Jet Mode: Minimum 9 Meters. Minimum Operating Time With Full Throttle: 18 Seconds. Life Of The Extinguisher Shall Not Be Less Than 10 Years. Operating Temperature : 50 – 550 Cshall Be Supplied Along With Following Spares: Spare Compressed Air Cylinder: 2 Nos. O – Rings Of Each Size : 2 Sets. Tool Kit ( Like Allen Key , Munkey Spanner, Measuring Mug, Funnel Etc., ) Supply Of Galvanized Mild Steel Buckets Mounted In Four Bucket Stand Fabricated From Angles / Square Tubes With Gi Sheet Hood For Rain Protection. ( Supply Shall Include Stand And Four Buckets ) Sand Bucket Shall Comply To Following Specifications. The Galvanized Mild Steel Buckets Shall Comply To The Is 2546 With Latest Amendments. Material Shall Confirm To Grade St. 34 Of Is 1069. Operational Test And Re-Filling Of Extinguisher To Be Quoted On Per Extinguisher Per Re-Filling For Extinguishers For 2Kg Co2 Type Fire Extinguisher ( Item No. 1 ) Applicable For First Four Years From Date Of Acceptance, Date Of Request From Mcf For Refilling Will Be Considered. ( Including Transportation To And Fro From Mcf, Bhopal ) Work Shall Be Carried Out As Per Is Operational Test And Re-Filling Of Extinguisher To Be Quoted On Per Extinguisher Per Re-Filling For Extinguishers For 2Kg Co2 Type Fire Extinguisher ( Item No. 1 ) Applicable For 5Th To 8Th Year From Date Of Acceptance, Date Of Request From Mcf For Refilling Will Be Considered. ( Including Transportation To And Fro From Mcf, Bhopal ) Work Shall Be Carried Out As Per Is Pressure Testing Of Extinguisher As Per Is And Issue Of Pressure Test Certificate For Extinguisher To Be Quoted On Per Extinguisher Per Pressure Testing Of Extinguishers For 2Kg Co2 Type Fire Extinguisher ( Item No. 1 ) Applicable For First Four Years From Date Of Acceptance, Date Of Request From Mcf For Pressure Testing Will Be Considered. ( Including Transportation To And Fro From Mcf, Bhopal ) Pressure Testing Of Extinguisher As Per Is And Issue Of Pressure Test Certificate For Extinguisher To Be Quoted On Per Extinguisher Per Pressure Testing Of Extinguishers For 2Kg Co2 Type Fire Extinguisher ( Item No. 1 ) Applicable For 5Th To 8Th Year From Date Of Acceptance, Date Of Request From Mcf For Pressure Testing Will Be Of Acceptance, Date Of Request From Mcf For Refilling Will Be Considered. ( Including Transportation To And Fro From Mcf, Bhopal ) Work Shall Be Carried Out As Per Is Pressure Testing Of Extinguisher As Per Is And Issue Of Pressure Test Certificate For Extinguisher To Be Quoted On Per Extinguisher Per Pressure Testing Of Extinguishers For 3Kg Co2 Type Fire Extinguisher ( Item No. 2 ) Applicable For First Four Years From Date Of Acceptance, Date Of Request From Mcf For Pressure Testing Will Be Considered. ( Including Transportation To And Fro From Mcf, Bhopal ) Work Shall Be Carried Out As Per Is Pressure Testing Of Extinguisher As Per Is And Issue Of Pressure Test Certificate For Extinguisher To Be Quoted On Per Extinguisher Per Pressure Testing Of Extinguishers For 3Kg Co2 Type Fire Extinguisher ( Item No. 2 ) Applicable For 5Th To 8Th Year From Date Of Acceptance, Date Of Request From Mcf For Pressure Testing Will Be Considered. ( Including Transportation To And Fro From Mcf, Bhopal )

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy