Repair/ Maintenance / Replacement Of Cables , Mccbs , Apfc Panel And Other Misc Work At Saibaba Complex , Ch Complex , Cmdc , 4 Rmc , Rf Line Area Under Age Em South Pune, GE SOUTH PUNE-Maharashtra

Military Engineer Services-MES has published Repair/ Maintenance / Replacement Of Cables , Mccbs , Apfc Panel And Other Misc Work At Saibaba Complex , Ch Complex , Cmdc , 4 Rmc , Rf Line Area Under Age Em South Pune. Submission Date for this Tender is 10-08-2020. MCCB Tenders in GE SOUTH PUNE Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

24857335
Corrigendum : Repair/ Maintenance / Replacement Of Cables , Mccbs , Apfc Panel And Other Misc Work At Saibaba Complex , Ch Complex , Cmdc , 4 Rmc , Rf Line Area Under Age Em South Pune
National Competitive Bid
Indian
Maharashtra
GE SOUTH PUNE
10-08-2020

Tender Details

Repair / Maintenance / Replacement Of Cables , Mccbs , Apfc Panel And Other Misc Work At Saibaba Complex , Ch Complex , Cmdc , 4 Rmc , Rf Line Area Under Age Em South Pune

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jul-2020 8873 Corrigendum No 1 BOQ BOQ 03-08-2020
2 03-Aug-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Name of Work : REPAIR/ MAINTENANCE / REPLACEMENT OF CABLES, MCCBs, APFC PANEL AND OTHER MISC WORK AT SAIBABA COMPLEX, CH COMPLEX, CMDC , 4 RMC, RF LINE AREA UNDER AGE EM SOUTH PUNE
Sl. No. Item Description Item Code / Make Quantity Unit
1 1 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in the following type of strata complete all as specified and as directed by the Engineer-in-Charge :-
2 1.01 Soft/Loose soil 75 Cum
3 1.02 Hard/ Dense soil 125 Cum
4 1.03 Soft/disintegrated Rock 45 Cum
5 2 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. 141 Cum
6 3 Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed by the Engineer - in - Charge. 104 Cum
7 4 Supply and spread clean dry river sand in trenches for sand cushion for laying of cables to the full width of excavated trench, gently punned down etc all as specified and as directed. 92 Cum
8 5 Supply and lay Un- reinforced precast concrete cable cover class LV type -I flat size 250 mm x 150 mmx 40 mm cmplete all as specified and as directed. 6600 Each
9 6 M & L for Earthing complete (Generator, Transformer, lightning arrestor and feeder pillar box) with galvanised steel earth plate electrode '60cm × 60cm × 6mm thick, buried 'directly in ground (earth pit not less 'than 2.25 metres deep below normal ground 'level) with top edge of the plate not 'less than 1.5 metres below normal ground level', connected to 'galvanised iron strip 32x6mm by means of bolts, nuts, check 'nuts and washers of galvanised iron or steel earth strip protected by provision of GI 'medium grade' pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with 40mm thick cover in RCC (1:2:4) type B-1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, \nContd.... 20 Each Job
10 6.01 ITEM No. 06.00 Contd...\nincluding GI 'medium grade' 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of phosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point all as specified or indicated 'including testing on completion.\n[NOTE :- GI strip and GI pipe 40mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to be included in the unit rate.]
11 7 M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32 x 6mm galvanized iron strip, complete all as specified and directed. 100 RM
12 8 Supply and fix in repair 4 Pole Power Contactors - Type MCX 13 AC-1 80 Amps Confirms to IS / IEC 60947-4-1 & IEC 60947-4-1 CAT NO- CS97015 complete all as directed by Engineer-in-Charge\n[Make: L&T/Havells/HPL] 9 Each
13 9 Supply, laying, testing and commissionnig of UG LT cables 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminium conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimping type cable lugs in LT panel/MCCB in bldg etc to suit the cable laid in trenches/fixed to poles/drawn through pipes complete of sizes 300 Sqmm 3.5 core complete all as specified and as directed. 50 RM
14 10 All as item No. 9.00 but 240 sq mm 3.5 core complete all as specified and as directed. 150 RM
15 11 All as item No. 9.00 but 185 sq mm 3.5 core complete all as specified and as directed. 100 RM
16 12 All as item No. 9.00 but 120 sq mm 3.5 core complete all as specified and as directed. 250 RM
17 13 All as item No. 9.00 but 70 sq mm 3.5 core complete all as specified and as directed. 200 RM
18 14 All as item No. 9.00 but 50 sq mm 3.5 core complete all as specified and as directed. 300 RM
19 15 All as item No. 9.00 but 25 sq mm 3.5 core complete all as specified and as directed. 250 RM
20 16 All as item No. 9.00 but 16 sq mm 4 core complete all as specified and as directed. 200 RM
21 17 All as item No. 9.00 but 6 sq mm 2 core complete all as specified and as directed. 200 RM
22 18 Supply and laying 40mm bore light grade GI pipe fixed to walls / poles or laid in trenches, road crossing etc, for protection of under ground cable including sealing ends with hessian cloth impregnated with bituminous compound in ground and with suitable clamps, bolt/nuts etc for fixing on walls, poles etc. complete all as specified and directed. 40 RM
23 19 All as item No. 18.00 but 50 mm bore complete all as specified and as directed. 30 RM
24 20 All as item No. 18.00 but 80 mm bore complete all as specified and as directed. 10 RM
25 21 M&L for bringing Cable testing van (Fault Finder) for detecting the location of fault in the LT UG cable 1.1 KV / HT cable 11 KV of any size complete all as specified and as directed 15 Each Job
26 22 M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 185 to 300 Sqmm 3.5 core including all accessories required. \n[Make :- Denson/M Seal/Siemens.] 24 Each
27 23 M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 70 to 120 Sqmm 3.5 core including all accessories required. \n[Make :- Denson/M Seal/Siemens.] 26 Each
28 24 M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 25 to 50 Sqmm 3.5 core including all accessories required. \n[Make :- Denson/M Seal/Siemens.] 30 Each
29 25 M&L in replacement for heat shrinkable Straight through jointing kit for LT 1.1 KV XLPE cables 6 to 16 Sqmm 2/4 core including all accessories required. \n[Make :- Denson/M Seal/Siemens.] 22 Each
30 26 M&L in replacement of outdoor end termination joint cable jointing kit out door heat shrink type suitable for 11 KV / 22 KV HT cable 95 sq mm 3 core with jointing material including all accessories required. \n[Make :- Denson/M Seal/Siemens.] 9 Each
31 27 Design, supply,install, test and comissioning of free standing floor mounted, dust and vermin proof LT Panel of suitable size for out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted duly powder coated after 7 tank process. The panel shall consist of 1600 ,Amps rating TPN bus bars of high conductivity aluminium alloy and half neutral with aluminium bus bar RYB insulated complete and shall be provided with colour coded heat shrinkaable sleeves,with sufficient depth of the panel for accommodating all switchgears in the panel. 1 Each Job
32 27.01 ITEM NO. 27.00 Contd...\nThe panel shall be modular/cubical type with bus chamber cable ally and provided with separate fully compartmentalised construction for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged and double door, front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm, embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate, 600 mm above ground level and comprising the following including taking out any type of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc\n[Note- (i) Incoming ACBs and Outgoing ACBs & MCCBs will be measured and paid seprately. \n(ii) All incomming & outgoing MCCBs will be connected with spreader link.]
33 27.02 ITEM NO. 27.00 Contd...\nINCOMING :-\n(a) LT ACB 4 pole 1250 Amps capacity rup cap 50 KA at 415 volt 50 Hz AC EDO type - 01 No incoming \nOUTGOING :-\n(a) LT ACB 4 pole 630 Amps capacity rup cap 50 KA at 415 volt 50 Hz AC EDO type - 02 Nos Out going \n(b) MCCB 4 pole 125 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed with electronic protection unit type with rotary handle - 02 Nos \n(Make for MCCB / ACB : Legrand / L&T / ABB)\n(c) MCCB 4 pole 100 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed with electronic protection unit type with rotary handle - 04 Nos Out going \n(d) LT Danger notice plate -01 No\n(e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables\n
34 28 Design, supply,install, test and comissioning of free standing floor mounted type, dust and vermin proof LT Panel of suitable size for out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted duly powder coated after 7 tank process. The panel shall consist of 1200 ,Amps rating TPN bus bars of high conductivity aluminium alloy and half neutral with aluminium bus bar RYB insulated complete and shall be provided with colour coded heat shrinkaable sleeves,with with sufficient depth of the panel for accommodating all switchgears in the panel. 1 Each Job
35 28.01 ITEM NO. 28.00 Contd...\nThe panel shall be modular/cubical trype with bus chamber cable allyand provided with separate fully compartmentalised construction for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged and double door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out any type of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc \n[Note :- (i)Incoming ACBs and Outgoing MCCBs will be measured and paid seprately\n(ii) All incomming and outgoing MCCBs will be connected with spreader link.]
36 28.02 ITEM NO. 28.00 Contd...\nINCOMING :-\n(a) LT ACB 4 pole 800 Amps capacity rup cap 50 KA at 415 volt 50 Hz AC EDO type - 01 No incoming \nOUTGOING :-\n(a) MCCB 4 pole 250 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed with electronic protection unit type with rotary handle - 02 Nos Out going \n(b) MCCB 4 pole 200 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed with electronic protection unit type with rotary handle - 02 Nos \n[Make for ACB/MCCBs : Legrand / L&T / ABB]\n(c) MCCB 4 pole 100 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed with electronic protection unit type with rotary handle - 02 Nos Out going \n(d) LT Danger notice plate -01 No\n(e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables\n
37 29 Supply & Fix 1250 Amps Air Circuit Breaker main chasis ( Electrically Draw Out) EDO type with ACB truck carriage with microprocessor release,Earth fault protection , 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KA fixed in panel complete including relay wiring with copper conductor of suitable size and connecting bus bar with ACB ,LT UG cable connection with main incoming ACB with lugs and connected materials and complete connection all as directed by Engr in charge. \n[Make- Legrand Cat No- 669569 or equivalent in L&T/ABB.] 1 Each
38 30 Supply & Fix 800 Amps Air Circuit Breaker main chasis ( Electrically Draw Out) EDO type with ACB truck carriage with microprocessor release,Earth fault protection , 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KA fixed in panel complete including relay wiring with copper conductor of suitable size and connecting bus bar with ACB ,LT UG cable connection with main incoming ACB with lugs and connected materials and complete connection all as directed by Engr in charge. \n[Make- Legrand Cat No- 669567 or equivalent in L&T/ABB.] 1 Each
39 31 Supply & Fix 630 Amps Air Circuit Breaker main chasis (Electrically Draw Out) EDO type with ACB truck carriage with microprocessor release, Earth fault protection, 4 pole, 50 KA breaking capacity 415 volts with all draw out type mechanism, advanced self powered electronic protection units, neutral overload protection, automatic earth fault relay / over current relay , automatic safety shutter, inbuilt temperature protection, icu=ics=icw(1s)=50 KA fixed in panel complete including relay wiring with copper conductor of suitable size and connecting bus bar with ACB ,LT UG cable connection with main incoming ACB with lugs and connected materials and complete connection all as directed by Engr in charge. \n[Make- Legrand Cat No- 669566 or equivalent in L&T/ABB.] 2 Each
40 32 Supply and Fix in replacement of MCCB 63 Amps to 100 Amps,16 KA,3 Pole,415V complete all as specified and directed by Engr-in-Charge. \n[Make - Legrand /L&T/ABB] 22 Each
41 33 Supply and Fix in replacement of MCCB 63 Amps to 100 Amps, 16 KA, 4 Pole, 415V with electronic protection unit complete all as specified and directed by Engr-in-Charge. [Make - Legrand /L&T/ABB] 7 Each
42 34 Supply and Fix in replacement of MCCB 125 Amps,16KA, 3 Pole, 415V complete all as specified and directed by Engr-in-Charge. \n[Make - Legrand/L&T/Siemens] 12 Each
43 35 Supply and Fix in replacement of MCCB 125 Amps,16KA, 4 Pole, 415V with electronic protection unit complete all as specified and directed by Engr-in-Charge. \n[Make - Legrand /L&T/ABB] 5 Each
44 36 Supply and Fix in replacement of MCCB 200 Amps,25 KA,3 Pole,415Vcomplete all as specified and directed by Engr-in-Charge. \n[Make - Legrand /L&T/ABB] 10 Each
45 37 Supply and Fix in replacement of MCCB 200 Amps,25 KA,4 Pole,415V with electronic protection unit complete all as specified and directed by Engr-in-Charge. \n[Make - Legrand /L&T/ABB] 4 Each
46 38 Supply and Fix in replacement of MCCB 250 Amps,25 KA,3 Pole,415Vcomplete all as specified and directed by Engr-in-Charge.\n[Make - Legrand /L&T/ABB] 7 Each
47 39 Supply and Fix in replacement of MCCB 250 Amps,25 KA,4 Pole,415V with electronic protection unit complete all as specified and directed by Engr-in-Charge. \n[Make - Legrand /L&T/ABB] 4 Each
48 40 Supply and Fix in replacement of MCCB 400 Amps,36 KA,3 Pole,415Vcomplete all as specified and directed by Engr-in-Charge. \n[Make - Legrand /L&T/ABB] 5 Each
49 41 Supply and Fix in replacement of MCCB 400 Amps,36 KA,4 Pole,415V with electronic protection unit complete all as specified and directed by Engr-in-Charge. \n[Make - Legrand /L&T/ABB] 3 Each
50 42 S&F IP-54, protection metal door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 12 way, 36 modules with 250 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed / surface mounted on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make - Legrand cat no-5077 63 / ABB/L&T. \n[Note - MCCB 250 Amps 4 pole 25 KA with electronic protection unit as incomer is included in the rate.] 5 Each
51 43 S&F IP-54, protection metal door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 8 way, 24 modules with 160 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed / surface mounted on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make - Legrand cat no-5077 52 / ABB/L&T. \n[Note - MCCB 160 Amps 4 pole 25 KA with electronic protection unit as incomer is included in the rate.] 12 Each
52 44 S&F IP-54, protection metal door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules with 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed / surface mounted on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make - Legrand cat no-5077 50 / ABB/L&T. \n[Note :- MCCB 100 Amps 4 pole 16 KA with electronic protection unit as incomer is included in the rate.] 20 Each
53 45 S&F MCB SPN DB 12 way ,double door, with 200 amp rated busbar 240 V, SPN recess mounted/wall mounted all as directed and specified by engineer in charge. 12 Each
54 46 S&F MCB SPN DB 8 way ,double door, with 200 amp rated busbar 240 V, SPN recess mounted/wall mounted all as directed and specified by engineer in charge. 25 Each
55 47 S&F MCB SPN DB 4 way ,double door, with 200 amp rated busbar 240 V, SPN recess mounted/wall mounted all as directed and specified by engineer in charge. 30 Each
56 48 S&F MCB SP 6-32amps,10KA,'C' series complete all as specified and as directed. 250 Each
57 49 S&F MCB SPN 10-40 amps,10KA, 240V,'C' series complete all as specified and as directed. 75 Each
58 50 S&F MCB TP 40 amps,10KA, 240V,'C' series complete all as specified and as directed. 25 Each
59 51 S&F MCB TP 63 amps,10KA, 240V,'C' series complete all as specified and as directed. 15 Each
60 52 S&F MCB TPN 32 amps,10KA, 240V,'C' series complete all as specified and as directed. 20 Each
61 53 S&F MCB TPN 63 amps,10KA, 240V,'C' series complete all as specified and as directed.\n[Make for Sl. No. 45 to 53 above : Legrand / L&T / ABB] 10 Each
62 54 S & F Sheet metal, 20 amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps,10 KA breaking capacity, 'C' series, 240 V complete all as specified and as directed. 15 Each
63 55 M & L for Sub main wiring complete with two single core 2.5 sqmm ,1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 1.5 sqmm in and including PVC conduit / casing caping for consealed/ surface wiring as per site requirement including cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc.complete all as specified and as directed by the Engineer-in-Charge. 100 RM
64 56 M & L for Sub main wiring complete with two single core 4 sqmm ,1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 2.5 sqmm in and including PVC conduit / casing caping for consealed/ surface wiring as per site requirement including cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc.complete all as specified and as directed by the Engineer-in-Charge. 250 RM
65 57 M & L for Sub main wiring complete with two single core 6 sqmm ,1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 4 sqmm in and including PVC conduit / casing caping for consealed/ surface wiring as per site requirement including cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc.complete all as specified and as directed by the Engineer-in-Charge. 200 RM
66 58 M & L for Sub main wiring complete with four single core 4 sqmm ,1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 2x2.5 sqmm in and including PVC conduit / casing caping for consealed/ surface wiring as per site requirement including cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc.complete all as specified and as directed by the Engineer-in-Charge. 200 RM
67 59 M & L for Sub main wiring complete with four single core 6 sqmm ,1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 2x4 sqmm in and including PVC conduit / casing caping for consealed/ surface wiring as per site requirement including cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc.complete all as specified and as directed by the Engineer-in-Charge. 100 RM
68 60 S&F in repair post top lantern pure polyster UV resistant powder coated die cast aluminium housing with PMMA opal diffuser for uniform illumination type 45 W high power LEDs at light source and symetrical light distribution. CAT Part No LP02-501-XXX-57-XX of WIPRO or of equivalent in Bajaj/ Wipro/phillips/HPL specified here-in-after. 12 Each
69 61 S&F In repair driver suitable for LED POST TOP light fitting of 20 to 30 wattage as per the existing make of the fitting and testing lights complete all as directed by Engineer-in-Charge 10 Each
70 62 M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate etc including necessary form work complete all as specified and directed by Engr-in-charge 1 Cum
71 63 M&L for Reinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 100 mm ,full round as specified by Engr-in-charge. 100 RM
72 64 M&L for Reinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 100 mm ,half round (02 Nos for top & bottom) as specified by Engr-in-charge. 100 RM
73 65 S&F Timelite distribution boards of Indo Asian Cat no-TL032ABO, 32 A 3 pole/230V- with Analog Time Switch or of equivalent make in L&T / Legrand including connecting with street light and testing complete all as directed 2 Each
74 66 M & L for earthing with galvanised steel earth plate electrode 600 x 600 x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to a depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil / strata and testing on completion etc complete all as specified and directed by Engr-in-Charge. 23 Each
75 67 Supply and fix earth continuity conductor or main earthing GI lead fixed to wall or pole on floor of size 4mm dia steel wire. 125 RM
76 68 S&F LED Fantasy Bollard LB14 of 11 Watt IP 65 protection, corrosion resistance better optics for uniform distribution all as specified and directed by Engn-in-charge. \n[Make :- WIPRO cat part no LB14-131-XXX-65-05 or equivalent in Crompton/Bjajaj/ HPL] 20 Each
77 69 Supplying and fixing LED light fitting,1X20 Watt surface mounted Trim LED high efficiency LED luminaire aluminum linear batten ingress protection : IP66 with white acrylic cover comprises pre-wired with high efficiency electronic driver, high translucent frosted diffuser gets glare free, smooth light distribution complete all as specified and as directed.\n[Make -Wipro cat No- LL20-281-XXX-65AL1 OR equivalent in Havells/HPL.] 50 Each
78 70 Supply & fix GI tubing 50 mm bore ''light grade'' for post top lantern of 2.25 mtr length including PCC foundation and fixing of post toplantern, nut bolts and washer etc and connecting with electrical supply complete all as specified and as directed by Engineer-in-Charge 12 Each Job
79 71 Design, supply,install, test and comissioning of free standing floor mounted, dust and vermin proof APFC panel 100 KVAR out door type installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and duly powder coated after 7 tank process. The panel shall consist of 400 ,Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkaable sleeves,with more depth for accomodating Capacitor bank 08 Nos inside of the panel. 1 Each
80 71.01 ITEM NO. 71.00 Contd...\nThe panel shall be modular/cubical type with bus chamber cable allyand provided with separate fully compartmentalised construction for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged and double door , front and rear openable with locking arrangement and suitable for 1100 Volts grade, 3 phase 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm, embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out any type of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc
81 71.02 ITEM NO. 71.00 Contd...\nINCOMING :-\n(a) MCCB 4 pole 200 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming \nOUTGOING :-\n100 KVAR L&T Cat No. LTBCH box type heavy duty capacitor bank in following steps :- \n(a) 1x5 KVAR-03 Nos\n(b) 1x10 KVAR-02 Nos\n(c) 1x20 KVAR-02 Nos\n(d) 1x25 KVAR-01 No\n(e) MCB TP of suitable size on each capacitor \n(f) Capacitor Contractor of suitable size for each capacitor bank\n(g) 8 Stage APFC relay microprocessor based-01 No\n(h) Auto/Mannual selector switch -01 No\n(j) Digital type Ammeter/ Voltmeter , selector switch, CTs etc\n(k) Thermostat Control Axial Fan of suitable size -01 No\n(l) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables included all required CTs for APFC panels.\n(m) ON/OFF switch for each capacitor with LED lamp\n(n) 3 KVAR fixed compensate with capacitor duty contactor MCB TP, ON / OFF switch and LED Lamp.\n[Make for MCCB/Capacitor Bank : L&T / Siemens / ABB]
82 72 Design, supply,install, test and comissioning of free standing floor mounted type, dust and vermin proof LT Panel of suitable size for out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted duly powder coated after 7 tank process. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkaable sleeves,with 600 mm depth of the panel. 1 Each Job
83 72.01 ITEM NO. 72.00 Contd...\nThe panel shall be modular/cubical type with bus chamber cable allyand provided with separate fully compartmentalised construction for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged and double door, front and rear openable with locking arrangement and suitable for 1100 Volts grade, 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out any type of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc\n(Make for MCCBs :- Legrand / L&T / ABB)\n[Note : All incomming & outgoing MCCBs will be connected with spreader link]
84 72.02 ITEM NO. 72.00 Contd...\nINCOMING :-\n(a) MCCB 4 pole 400 Amps capacity rup cap 36 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming \nOUTGOING :-\n(a) MCCB 4 pole 200 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release typewith rotary handle - 01 Nos Out going \n(b) MCCB 3 pole100 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going \n(c) MCCB 3 pole 63 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going \n(d) LT Danger notice plate -01 No\n(e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables
85 73 Design, supply, install, test and comissioning of free standing floor mounted type, dust and vermin proof LT Panel of suitable size for out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted duly powder coated after 7 tank process. The panel shall consist of 600 Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkaable sleeves, with 600 mm depth of the panel. 1 Each Job
86 73.01 ITEM NO. 73.00 Contd...\nThe panel shall be modular/cubical type with bus chamber cable allyand provided with separate fully compartmentalised construction for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged and double door, front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out any type of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc \n(Make for MCCB : Legrand / L&T / ABB]\n[Note :- (i) Incoming and outgoing mccbs with connected accessories are included in same item\n(ii) All incomming & outgoing MCCBs will be connected with spreader link]
87 73.02 ITEM NO. 73.00 Contd...\nINCOMING :-\n(a) MCCB 4 pole 400 Amps capacity rup cap 36 KA at 415 volt 50 Hz AC fixed thermal magnetic release type and earth leakage protection ICS =100% ICU with rotary handle - 01 No incoming \nOUTGOING :-\n(a) MCCB 4 pole 250 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release typewith rotary handle - 01 Nos Out going \n(b) MCCB 3 pole 125 Amps capacity rup cap 25 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 01 Nos Out going \n(c) MCCB 3 pole 63 Amps capacity rup cap 16 KA at 415 volt 50 Hz AC fixed thermal magnetic release type with rotary handle - 02 Nos Out going \n(d) LT Danger notice plate -01 No\n(e) Panel Control wiring complete with suitable size copper conductor cable and suitable size gland for LT cables\n(Make for MCCBs :- Legrand / L&T / ABB)