Communications and Information Technology  Government Departments Closing in 0 days TDR #24823178

Maintenance Of Dg Sets On Call Basis In Ssa Nanded .

Issued by Government Departments · Nanded SSA, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Jul 2020
0 days left
EMD
9555
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nanded SSA → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

20E / Eee / Bsnl / Ngp / 2020-21 Maintenance Of Dg Sets On Call Basis In Ssa Nanded . , Dg Sets Upto 30 Kva , Attending Complaint And Checking Of Faults Of Ea Set By Skilled Technician , Rectification Of Minor Faults / Wiring / Lubricating Etc . As Reqd For The Following Distance Of One Side From Sub Divisional Office . This Item Shall Be Paid Once In 4 Months Period . Any Subsequent Visit Required Shall Be Borne By The Firm Within Stipulated Period Of 4 Months . ( I ) Up To 50 Kms , Ii ) Above 50 To 100 Kms , Iii ) Above 100 To 150 Kms , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Ea Set Complete With Cleaning Of Air Filter Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , If Required Replacement Of Radiator Coolant With Distilled Water & Addition Of Coolant Additive Concentrate , Checking & Reset Injector Pressure , Injector Pump Timing , Tightening Of Cylinder Head Studs / Nuts , Adjustment Of Engine Valve Clearance , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Air Piping , Belt Tensions I / C Cleaning & De-Dusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc . Actual Load Testing Of Ea Set After Servicing As Directed . [ B Check Once In 12 Months ] I ) Up To & Including 20 Kva Ea , Ii ) More Than 20 Kva To 30 Kva Ea , Supplying & Fixing Of Fully Charged 12 Volt 88Ah Battery For Starting Of Ea Set Complete With Lugs ( I / C Credit Of Old Battery ) Of Following Types:- ( I ) Lead Acid Maintenance Free Battery , ( Ii ) Super Capacitors 120F Battery Suitable Upto 25Kva Dg Cranking System , Replacement Of Following By New Components Of Ea Sets Below 30 Kva I / C Fixing / Connections , Testing Etc . I / C Credit For Old Material As Reqd . , Up To 32 Kva Dg ( I ) Oil Top Up ( With Recommeded Grade & Make ) , ( Ii ) Pump Caliberation From Authorised Dealer ( With Out Nozzle Replacement ) , ( Iii ) Starter Repair I / C Replacement Of Spares , ( Iv ) Charging Alternator Repair I / C Replacement Of Spares , ( V ) Fuel Inlet / Outlet Pipe , ( Vi ) Gasket Kit Excluding Sump Kit , ( Vii ) Automatic Voltage Regulator ( Avr ) , ( Viii ) Mains / Dg Contactor , ( Ix ) 32 A Tpn Mcb C Curve , ( X ) 63 A Fp Isolator , ( Xi ) Led Lamp Indication Lamp , ( Xii ) Stop Solenoid , ( Xiii ) Push Button , ( Xiv ) Voltmeter , ( Xv ) Ampere Meter , ( Xvi ) Oil Pressure Meter , ( Xvii ) Water Temp Meter , ( Xviii ) Oil Temp Meter , ( Xix ) Oil Pressure Pipe , ( Xx ) Smps 12 Volt , 10 Amp Battery Charger , ( Xxi ) Hose Kit , ( Xxii ) Fan Belt , ( Xxiii ) Water Pump Assembly , ( Xxiv ) Llop Switch , ( Xxv ) Water Temperature Switch 96 Deg . , ( Xxvi ) Exhaust Below , ( Xxvii ) Door Hinges , ( Xxviii ) Relay Card ( Start & Stop ) , ( Xxix ) Key Switch , ( Xxx ) Air Filter

BOQ

Name of Work:- Maintenance of DG sets on call basis in SSA Nanded.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11DG sets upto 30 KVASHI
22.01Attending complaint and checking of faults of EA set by skilled technician, rectification of minor faults/wiring/lubricating etc. as reqd for the following distance of one side from Sub Divisional Office. This item shall be paid once in 4 months period. Any subsequent visit required shall be borne by the firm within stipulated period of 4 months. (i) Up to 50 KmsSH1_120Job
32.02ii) Above 50 to 100 kmsSHI_215Job
42.03iii) Above 100 to 150 kmsSHI_310Job
53.01Servicing & Routine maintenance (B check) of following capacity of EA set complete with cleaning of Air Filter element, replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, if required replacement of radiator coolant with distilled water & addition of coolant additive concentrate, Checking & reset injector pressure, injector pump timing, tightening of cylinder head studs/nuts, adjustment of engine valve clearance, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, air piping, belt tensions i/c cleaning & de-dusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc. Actual load testing of EA set after servicing as directed.\n[\"B\" check once in 12 months] i) Up to & including 20 KVA EASHII-430Job
63.02ii) More than 20 kVA to 30 kVA EASHII-55Job
74.01Supplying & fixing of fully charged 12 volt 88AH battery for starting of EA set complete with lugs (i/c credit of old battery) of following types:- (i) Lead acid Maintenance Free batterySHII-65Each
84.02(ii) Super Capacitors 120F battery suitable upto 25kVA DG cranking systemSHII-75Each
95.01Replacement of following by new components of EA sets below 30 kVA i/c fixing/connections, testing etc. i/c credit for old material as reqd.SHII-8
105.02Up to 32 kVA DG (i) Oil top up ( with recommeded grade & make)SHII-920Ltrs
115.03(ii) Pump caliberation from authorised dealer (with out nozzle replacement)SHII-105Each
125.04(iii)Starter repair i/c replacement of sparesSHII-115Each
135.05(iv) Charging alternator repair i/c replacement of sparesSHII-125Each
145.06(v)Fuel inlet / outlet pipeSHII-135Each
155.07(vi)Gasket kit excluding sump kitSHII-145Each
165.08(vii)Automatic voltage regulator (AVR)SHII-154Each
175.09(viii)Mains / DG contactorSHII-164Each
185.1(ix)32 A TPN MCB 'C' curveSHII-174Each
195.11(x)63 A FP isolatorSHII-184Each
205.12(xi)LED Lamp indication lampSHII-195Each
215.13(xii)Stop solenoidSHII-205Each
225.14(xiii)Push buttonSHII-215Each
235.15(xiv)VoltmeterSHII-225Each
245.16(xv) Ampere MeterSHII-235Each
255.17(xvi)Oil pressure meterSHII-243Each
265.18(xvii)Water temp meterSHII-253Each
275.19(xviii) Oil temp meterSHII-263Each
285.2(xix) Oil pressure pipeSHII-273Each
295.21(xx)SMPS 12 volt, 10 Amp Battery ChargerSHII-283Each
305.22(xxi)Hose kitSHII-293Each
315.23(xxii)Fan beltSHII-303Each
325.24(xxiii)Water pump assemblySHII-313Each
335.25(xxiv)LLOP switchSHII-323Each
345.26(xxv)Water Temperature Switch 96 Deg.SHII-333Each
355.27(xxvi)Exhaust BelowSHII-343Each
365.28(xxvii)Door HingesSHII-353Each
375.29(xxviii)Relay Card (Start & Stop)SHII-363Each
385.3(xxix)Key SwitchSHII-373Each
395.31(xxx)Air FilterSHII-383Each

AI Tender Summary

OUR REF NO 24823178
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-07-2020
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description 20E / Eee / Bsnl / Ngp / 2020-21 Maintenance Of Dg Sets On Call Basis In Ssa Nanded . , Dg Sets Upto 30 Kva , Attending Complaint And Checking Of Faults Of Ea Set By Skilled Technician , Rectification Of Minor Faults / Wiring / Lubricating Etc . As Reqd For The Following Distance Of One Side From Sub Divisional Office . This Item Shall Be Paid Once In 4 Months Period . Any Subsequent Visit Required Shall Be Borne By The Firm Within Stipulated Period Of 4 Months . ( I ) Up To 50 Kms , Ii ) Above 50 To 100 Kms , Iii ) Above 100 To 150 Kms , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Ea Set Complete With Cleaning Of Air Filter Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , If Required Replacement Of Radiator Coolant With Distilled Water & Addition Of Coolant Additive Concentrate , Checking & Reset Injector Pressure , Injector Pump Timing , Tightening Of Cylinder Head Studs / Nuts , Adjustment Of Engine Valve Clearance , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Air Piping , Belt Tensions I / C Cleaning & De-Dusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc . Actual Load Testing Of Ea Set After Servicing As Directed . [ B Check Once In 12 Months ] I ) Up To & Including 20 Kva Ea , Ii ) More Than 20 Kva To 30 Kva Ea , Supplying & Fixing Of Fully Charged 12 Volt 88Ah Battery For Starting Of Ea Set Complete With Lugs ( I / C Credit Of Old Battery ) Of Following Types:- ( I ) Lead Acid Maintenance Free Battery , ( Ii ) Super Capacitors 120F Battery Suitable Upto 25Kva Dg Cranking System , Replacement Of Following By New Components Of Ea Sets Below 30 Kva I / C Fixing / Connections , Testing Etc . I / C Credit For Old Material As Reqd . , Up To 32 Kva Dg ( I ) Oil Top Up ( With Recommeded Grade & Make ) , ( Ii ) Pump Caliberation From Authorised Dealer ( With Out Nozzle Replacement ) , ( Iii ) Starter Repair I / C Replacement Of Spares , ( Iv ) Charging Alternator Repair I / C Replacement Of Spares , ( V ) Fuel Inlet / Outlet Pipe , ( Vi ) Gasket Kit Excluding Sump Kit , ( Vii ) Automatic Voltage Regulator ( Avr ) , ( Viii ) Mains / Dg Contactor , ( Ix ) 32 A Tpn Mcb C Curve , ( X ) 63 A Fp Isolator , ( Xi ) Led Lamp Indication Lamp , ( Xii ) Stop Solenoid , ( Xiii ) Push Button , ( Xiv ) Voltmeter , ( Xv ) Ampere Meter , ( Xvi ) Oil Pressure Meter , ( Xvii ) Water Temp Meter , ( Xviii ) Oil Temp Meter , ( Xix ) Oil Pressure Pipe , ( Xx ) Smps 12 Volt , 10 Amp Battery Charger , ( Xxi ) Hose Kit , ( Xxii ) Fan Belt , ( Xxiii ) Water Pump Assembly , ( Xxiv ) Llop Switch , ( Xxv ) Water Temperature Switch 96 Deg . , ( Xxvi ) Exhaust Below , ( Xxvii ) Door Hinges , ( Xxviii ) Relay Card ( Start & Stop ) , ( Xxix ) Key Switch , ( Xxx ) Air Filter
Basic Detail
Tender No 20e/EEE/BSNL/NGP/2020-21
Bidding Type Tender
Location
City Nanded SSA
State Maharashtra
Key Dates
Publish Date 07 Jul 2020
Submission Date 31 Jul 2020
Open Date 03 Aug 2020
Finance
Tender Value Ref. Documents
Tender Fee 590
EMD 9555
Exemption Not Available
Document List
34EBB683-A617-4463-A830-5FC8F05E50D0.html
Tendernotice_1.pdf
BOQ_597733.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 03, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

34EBB683-A617-4463-A830-5FC8F05E50D0.html

pdf

Tendernotice_1.pdf

xls

BOQ_597733.xls

TenderDetail