Public Works Department-PWD has published Drilling And Development Of 4 ( Four ) Nos . Small Bore Deep Tube Wells ( Sbdtw ) By Manual Means. Submission Date for this Tender is 05-08-2020. Drilling Work Tenders in Panisagar Tripura. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Jul-2020 | Date Corrigendum | Date | 31-07-2020 |
2 | 30-Jul-2020 | Extension of Date | Date | 05-08-2020 |
Name of Work: RURBAN Schemes in North Tripura District during the year 2020-21 / Drilling & Development of 04 (Three) nos. Small Bore Deep Tube Wells (SBDTW) by Manual means in/c installation of pump set, electrical panel board to be install in M.S. (18 SWG) 'KIOSK', commissioning of the tube well in/c domestic connection under Atal Jaldhara Mission within the jurisdiction of Panisagar RD Block under DWS Sub-Division, Panisagar/ Gr.I | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | SH: 4 Nos SBDTW | BI01010001010000000000000515BI0100001169 | ||
2 | 1.01 | Drilling and boring pilot hole in any soil strata by manual means, collection of soil samples of different strata met with during drilling at various suitable levels, preservation of samples in polythene bags / sample boxes and disposal of excess soil or mud, including the cost for water etc. as required to maintain the pilot hole properly as per specification and direction of the Engineer - in - charge.\ni) 100 mm dia | BI01010001010000000000000515BI0100001170 | 426.8 | Mtr |
3 | 1.02 | Reaming of pilot hole to an enlarged bore hole in any soil strata by manual means, disposal of excess soil or mud, including the cost for water etc. as required to maintain the bore hole properly as per specification and direction of the Engineer - in - charge.\ni. from 100 mm dia pilot hole to 250 mm bore hole | BI01010001010000000000000515BI0100001171 | 426.8 | Mtr |
4 | 1.03 | Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer - in - charge.\nA.'CM' Casing pipe | BI01010001010000000000000515BI0100001172 | ||
5 | 1.031 | i) 150 mm | BI01010001010000000000000515BI0100001173 | 146.4 | Mtr |
6 | 1.032 | ii) 100 mm | BI01010001010000000000000515BI0100001174 | 134 | Mtr |
7 | 1.033 | B.'RS' pipe i) 100 mm dia | BI01010001010000000000000515BI0100001175 | 146.4 | Mtr |
8 | 1.04 | Providing and fixing of UPVC end cap / well cap suitable for UPVC 'CM' casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer - in - charge. | BI01010001010000000000000515BI0100001176 | ||
9 | 1.041 | i. 100 mm dia | BI01010001010000000000000515BI0100001177 | 4 | No. |
10 | 1.042 | ii. 150 mm dia | BI01010001010000000000000515BI0100001178 | 4 | No. |
11 | 1.05 | Providing and fixing of UPVC reducer suitable for UPVC 'CM' casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer - in - charge.\ni. 150 x 100 mm dia | BI01010001010000000000000515BI0100001179 | 4 | No. |
12 | 1.06 | Providing and shrouding of the deep tube well assembly with washed pea gravels ( 2.0 - 4.75 mm effective size ) as per specification ( IS : 4097) and direction of the Engineer - in charge\ni) with pea gravels obtained from Golaghat Assam. | BI01010001010000000000000515BI0100001180 | 16 | Cum |
13 | 1.07 | Providing and fixing of housing clamp(made with 12 mm thick MS sheet)by welding with blind pipe including applying of anti-corrusive bitumastic paint as per specification and direction of the Engineer-in- charge.\ni)150 mm dia | BI01010001010000000000000515BI0100001181 | 8 | No. |
14 | 1.08 | Washing and development of tube well by using hand pump or by\nany suitable method and testing of the well as per specification and\ndirection of the Engineer - in - charge. | BI01010001010000000000000515BI0100001182 | 426.8 | Mtr |
15 | 1.09 | Providing & Lowering of submerssible pump of 45 mtr. head with suitable single phase submerssible motor in/c additional 32 mtr. submerssible 3 core copper flat cable (2.5 mm size) along with 40 mm gi pipe ( medium class) both end welded with each column pipe in 3 mtrertion 900 G.I single end flange bend G.I flange short pice G.I. tailpice and 100 mm dia C.I. non-returnvalve etc complete in respect as per direction of the engineer in charge.\na) 2000 GPH capacity submerssible pump with 3 HP submerssible Motor. | BI01010001010000000000000515BI0100001183 | 4 | No. |
16 | 1.1 | Supplying and fitting fixing of B 13 ( size width 450mmXlength 1200mmX height 850mm) fitted with 4 nos suportt of 75 mm X 75mm( 6mm thick) M.S. angle for embedding in 1:2:4 cement concrete base ( size 300 mm X 300 mm dia X600 mm) with proper locking arrangement and coated with anti corrosive main switch energy metter etc complete in all respect as per derection of the Engineer in charge. | BI01010001010000000000000515BI0100001184 | 4 | No. |
17 | 1.11 | Supplying and fitting fixing single phase motor starter unit( with 2 pole contactor, overload relay , volty metre& amps metter) 32 amps main switch(| 220 volt) of hecvels/BCH/L&T make in KILOSK in/c necessary elctric wiring and G.I. pipe earthing etc complete as per direction of the Engineer in charge i).For 3 Hp Submersible motor. | BI01010001010000000000000515BI0100001185 | 4 | No. |
18 | 1.12 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge.\ni. 2.50 sqmm | BI01010001010000000000000515BI0100001186 | 120 | Mtr. |
19 | 1.13 | Trial run and commissioning of the same in all respect as per direction of the engineeri-in - Charge. | BI01010001010000000000000515BI0100001187 | 4 | Job |
20 | 2 | SH: Pipe Line | BI01010001010000000000000515BI0100001188 | ||
21 | 2.01 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm(slope-1 in 200) including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge.\nA). For UPVC pipes in new work\na). In all kinds of soil | BI01010001010000000000000515BI0100001189 | ||
22 | 2.011 | i). For pipes not exceeding 90 mm dia | BI01010001010000000000000515BI0100001190 | 1225 | Mtr |
23 | 2.012 | ii). For pipes exceeding 90 mm dia but not exceeding 300 mm dia | BI01010001010000000000000515BI0100001191 | 1200 | Mtr |
24 | 2.02 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in charge.\nA) External work. | BI01010001010000000000000515BI0100001192 | ||
25 | 2.021 | i. 40 mm dia. nominal bore\n | BI01010001010000000000000515BI0100001193 | 6 | Mtr |
26 | 2.022 | ii. 80 mm dia. nominal bore\n | BI01010001010000000000000515BI0100001194 | 6 | Mtr |
27 | 2.03 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. \nA.Class - 3 ( working pressure 6.0 kg / cm2) | BI01010001010000000000000515BI0100001195 | ||
28 | 2.031 | i)40 mm OD | BI01010001010000000000000515BI0100001196 | 25 | Mtr |
29 | 2.032 | ii)50 mm OD | BI01010001010000000000000515BI0100001197 | 50 | Mtr |
30 | 2.033 | iii) 90 mm OD\n | BI01010001010000000000000515BI0100001198 | 1000 | Mtr |
31 | 2.034 | iii) 110 mm OD\n | BI01010001010000000000000515BI0100001199 | 800 | Mtr |
32 | 2.035 | iii) 140 mm OD\n | BI01010001010000000000000515BI0100001200 | 400 | Mtr |
33 | 2.04 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. | BI01010001010000000000000515BI0100001201 | ||
34 | 2.041 | i)50 mm dia \nA. PN - 1.0 | BI01010001010000000000000515BI0100001202 | 2 | No. |
35 | 2.042 | ii) 80 mm dia.\nA. PN - 1.6 | BI01010001010000000000000515BI0100001203 | 3 | No. |
36 | 2.043 | iii) 150 mm dia.\nA. PN - 1.6 | BI01010001010000000000000515BI0100001204 | 2 | No. |
37 | 2.05 | Providing and fixing in position Precast RCC hydrant post of size 200 x 200 mm at the bottom & 150 x 150 mm at the top and 1300 mm high ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 brick aggregate 1st class 20 mm nominal size) and steel reinforcement ( TMT bars ) 8 mm dia 1200 mm long 4 nos and 8 mm dia stirrup 9 Nos ), 500 mm shall be kept below ground level , embedding the same with in 500 x 500 x 500 mm cement concrete 1 : 5 : 10 ( 1 cement : 5 sand : 10 brick aggregate 1st class 40 mm nominal size ) including plastering the exposed surface with 12 mm thick cement mortar 1 : 3 ( 1 cement: 3 sand ) finished with a floating coat of neat cement ) including providing & embedding 15 mm dia G.I. pipe (medium class) 1250 mm long with necessary GI fittings like elbow 2 Nos, socket 1 no, nipple 300 mm long 1 no, union 1 no etc. and fitting fixing of CI long handle bib cock by welding with GI socket complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001205 | 1 | nos |
38 | 2.06 | Providing and fixing in position Precast RCC platform of size 1100 x 1100 mm x 100 mm with curb of size 50 x 50 mm keeping an opening of 100 mm long in a suitable place for draining out of water ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 brick aggregate 1st class 20 mm nominal size) and steel reinforcement ( TMT bars ) 8 Nos, 8 mm dia in both direction including plastering the exposed surface with 12 mm thick cement mortar 1 : 3 ( 1 cement: 3 sand ) finished with a floating coat of neat cement ) complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001206 | 1 | nos |
39 | 2.07 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. | BI01010001010000000000000515BI0100001207 | ||
40 | 2.071 | a) 15 mm dia. | BI01010001010000000000000515BI0100001208 | 300 | No. |
41 | 2.072 | b) 40 mm dia | BI01010001010000000000000515BI0100001209 | 2 | No. |
42 | 2.073 | c) 50 mm dia. | BI01010001010000000000000515BI0100001210 | 2 | No. |
43 | 2.074 | b) 80 mm dia. | BI01010001010000000000000515BI0100001211 | 1 | No. |
44 | 2.08 | Providing and fixing G.I. equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.\n | BI01010001010000000000000515BI0100001212 | ||
45 | 2.081 | a) 40 x 40 x 40 mm dia. | BI01010001010000000000000515BI0100001213 | 5 | No. |
46 | 2.082 | b) 50 x 50 x 50 mm dia. | BI01010001010000000000000515BI0100001214 | 5 | No. |
47 | 2.083 | c) 80 x 80 x 80 mm dia\n | BI01010001010000000000000515BI0100001215 | 2 | No. |
48 | 2.09 | Providing and fixing G.I. Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.\n | BI01010001010000000000000515BI0100001216 | ||
49 | 2.091 | ii) 50x50x15 mm dia | BI01010001010000000000000515BI0100001217 | 5 | No. |
50 | 2.092 | iii) 40x40x15 mm dia | BI01010001010000000000000515BI0100001218 | 5 | No. |
51 | 2.093 | iv) 80 x 80 x15 mm dia\n | BI01010001010000000000000515BI0100001219 | 5 | No. |
52 | 2.1 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.\n | BI01010001010000000000000515BI0100001220 | ||
53 | 2.101 | a) 50 x 40 mm dia. | BI01010001010000000000000515BI0100001221 | 5 | No. |
54 | 2.102 | b) 80 x 50 mm dia\n | BI01010001010000000000000515BI0100001222 | 2 | No. |
55 | 2.103 | c) 125 x 80 mm dia | BI01010001010000000000000515BI0100001223 | 1 | No. |
56 | 2.11 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.\n | BI01010001010000000000000515BI0100001224 | ||
57 | 2.111 | iii) 15 mm dia\n | BI01010001010000000000000515BI0100001225 | 300 | No. |
58 | 2.112 | i) 40 mm dia | BI01010001010000000000000515BI0100001226 | 2 | No. |
59 | 2.113 | ii) 50 mm dia | BI01010001010000000000000515BI0100001227 | 2 | No. |
60 | 2.12 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.\ni) 15 mm dia\n | BI01010001010000000000000515BI0100001228 | 150 | No. |
61 | 2.13 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.\na). by manual means | BI01010001010000000000000515BI0100001229 | 20 | Mtr. |
62 | 2.14 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the Engineer - in - charge (cost of earth work and fittings will be paid separately). \na) 15mm dia | BI01010001010000000000000515BI0100001230 | 750 | Mtr. |
63 | 2.15 | Providing and fixing brass ferrule with C.I. cover conforming to IS :2692 including boring and tapping the main as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.\nii.15 mm nominal bore | BI01010001010000000000000515BI0100001231 | 150 | No. |
64 | 2.16 | Providing and fixing in position Precast RCC hydrant post of size 200 x 200 mm at the bottom & 150 x 150 mm at the top and 1300 mm high ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 brick aggregate 1st class 20 mm nominal size) and steel reinforcement ( TMT bars ) 8 mm dia 1200 mm long 4 nos and 8 mm dia stirrup 9 Nos ), 500 mm shall be kept below ground level , embedding the same with in 500 x 500 x 500 mm cement concrete 1 : 5 : 10 ( 1 cement : 5 sand : 10 brick aggregate 1st class 40 mm nominal size ) including plastering the exposed surface with 12 mm thick cement mortar 1 : 3 ( 1 cement: 3 sand ) finished with a floating coat of neat cement ) including providing & embedding 15 mm dia G.I. pipe (medium class) 1250 mm long with necessary GI fittings like elbow 2 Nos, socket 1 no, nipple 300 mm long 1 no, union 1 no etc. and fitting fixing of CI long handle bib cock by welding with GI socket complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge.\n | BI01010001010000000000000515BI0100001232 | 1 | No. |
65 | 2.17 | Providing and fixing in position Precast RCC platform of size 1100 x 1100 mm x 100 mm with curb of size 50 x 50 mm keeping an opening of 100 mm long in a suitable place for draining out of water ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 brick aggregate 1st class 20 mm nominal size) and steel reinforcement ( TMT bars ) 8 Nos, 8 mm dia in both direction including plastering the exposed surface with 12 mm thick cement mortar 1 : 3 ( 1 cement: 3 sand ) finished with a floating coat of neat cement ) complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001233 | 1 | No. |
66 | 2.18 | Constructing masonry Chamber 90 x 90 x 100 cm, inside with brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design, CPWD specification and direction of the Engineer - in - charge.\nA). With First class bricks\n | BI01010001010000000000000515BI0100001234 | 2 | No |
67 | 2.19 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge\ni. 15 mm dia PVC /plastic bib cock \n | BI01010001010000000000000515BI0100001237 | 150 | No. |
68 | 2.2 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in charge\n | BI01010001010000000000000515BI0100001238 | ||
69 | 2.201 | i. 40 mm dia\n | BI01010001010000000000000515BI0100001239 | 1 | No. |
70 | 2.202 | ii. 50 mm dia \n | BI01010001010000000000000515BI0100001240 | 1 | No. |
71 | 2.203 | iii) 90 mm dia | BI01010001010000000000000515BI0100001241 | 4 | No. |
72 | 2.204 | iv) 110 mm dia | BI01010001010000000000000515BI0100001242 | 2 | No. |
73 | 3 | SH: Fenching Work Arround SBDTW | BI01010001010000000000000515BI0100001243 | ||
74 | 3.01 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. \n-All kinds of soil | BI01010001010000000000000515BI0100001244 | 82 | Cum |
75 | 3.02 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. | BI01010001010000000000000515BI0100001245 | 1 | Cum |
76 | 3.03 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: | BI01010001010000000000000515BI0100001246 | ||
77 | 3.031 | i) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001247 | 1 | Cum |
78 | 3.04 | Providing structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required | BI01010001010000000000000515BI0100001248 | 79.2 | Kg |
79 | 3.05 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or weight not less than 7.75 Kg per sqm including 25X5mm Flat beading | BI01010001010000000000000515BI0100001249 | 70.9 | Sqm |
80 | 3.06 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: \n12.47.1 Two or more coats on new work \n | BI01010001010000000000000515BI0100001250 | 72.5 | Sqm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail