Repair/Replacement Of Pipelines Of Various Sizes , Sluice Valve , Nrv , Pump Sets , Motors , Lt Panels And Allied Works In Tawi Area Under Ge Utilities Udhampur, UDHAMPUR-Jammu And Kashmir

Military Engineer Services-MES has published Repair/Replacement Of Pipelines Of Various Sizes , Sluice Valve , Nrv , Pump Sets , Motors , Lt Panels And Allied Works In Tawi Area Under Ge Utilities Udhampur. Submission Date for this Tender is 31-08-2020. Electrical Panel Tenders in UDHAMPUR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

24795810
Corrigendum : Repair/Replacement Of Pipelines Of Various Sizes , Sluice Valve , Nrv , Pump Sets , Motors , Lt Panels And Allied Works In Tawi Area Under Ge Utilities Udhampur
Open Tender
Indian
Jammu And Kashmir
UDHAMPUR
31-08-2020

Tender Details

Repair/Replacement Of Pipelines Of Various Sizes , Sluice Valve , Nrv , Pump Sets , Motors , Lt Panels And Allied Works In Tawi Area Under Ge Utilities Udhampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jul-2020 REVISED BOQ BOQ 27-07-2020
2 23-Jul-2020 RE-REVISED DATES Date 31-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 63000.0 /-
Tender Value
INR 31.50 Lakhs /-

BOQ Items

Name of Work: Repair/Replacement of pipelines of various sizes, sluice valve, NRV, pump sets, motors, LT panels and allied works in Tawi area under GE Utilities Udhampur
Ser. No. Item Description Item Code / Make Quantity Units
1 1 M&L for repair to leaking flanged joints of MS/GI pipe line of size 300mm bore by providing rubber or fiber board gasket properly in position for flanged ends pipes at any depth and replacing the unserviceable nut and bolts including necessary excavation and earth work in any type of soil, returning filling, bailing out water, cutting & welding wk where required of pipe complete all as specefied and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001132 20 Each\n Job
2 2 Description all as per serial item No 1.00 here-in-before but 250 mm bore pipe. BI01010001010000000000000515BI0100001133 10 Each Job
3 3 Description all as per serial item No 1.00 here-in-before but 200 mm bore pipe. BI01010001010000000000000515BI0100001134 10 Each Job
4 4 M&L for repair to leaking spigot & socketed joints of CI/DI pipe line of size 450 mm bore by providing lead joints using fresh lead & spun yarn in position for spigot & socketed pipes at any depth and retrieving old lead including necessary excavation & earth work in any type of soil, returning filling ,bailing out water, cutting & welding where required of pipe complete all as specefied and directed by Engr-in-Charge.\nNote for item No 1.00 to 4.00: - \n(a) Contractor fully responsible for necessary excavation for jointing work required T&P equipment , JCB work and man power at site requirment with making good disturbed surfaces of road/walls/floor etc and matching with existing surface include quoted rate. \n(b) Required extra fittings/pipe will be measured and paid seprate. BI01010001010000000000000515BI0100001135 5 Each\n Job
5 5 Description all as per serial item No 4.00 here-in-before but 300 mm bore pipe. BI01010001010000000000000515BI0100001136 20 Each\n Job
6 6 Description all as per serial item No 4.00 here-in-before but 250 mm bore pipe. BI01010001010000000000000515BI0100001137 20 Each\n Job
7 7 Description all as per serial item No 4.00 here-in-before but 200 mm bore pipe. BI01010001010000000000000515BI0100001138 15 Each\n Job
8 8 M&L for cutting existing CI/DI/MS pipe of bore 450/300/250 mm and jointing with proper welding and testing of all fittings complete with all welding/threading works and jointing material laid in trenches/ on surface / slopes/ pillars/ culverts complete all as specefied and directed by Engr-in-Charge.\nNote:- Excavation, earthwork & fittings will be measured and paid separately. BI01010001010000000000000515BI0100001139 10 Each\n Job
9 9 S&F in repair cast iron fittings for spigot and socket ends for pressure pipe for water mains such as bends, tapers tee pieces single branch, cross collar, caps and plugs suitable for 200 to 300 mm bore, all specifications as per IS-1538 (Pt-1 to 23)-1976 complete all as specefied and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001140 250 Kg
10 10 Description all as per serial item No 9.00 here-in-before but upto 150mm bore. BI01010001010000000000000515BI0100001141 150 Kg
11 11 M&L for run lead joints for CI/DI of spigot socketed ends pipes of size 300mm bore in position providing new lead ,using good quality spun yarn at any depth complete all as specefied and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001142 2 Each Job
12 12 Description all as per serial item No 11.00 here-in-before but 250mm bore. BI01010001010000000000000515BI0100001143 2 Each Job
13 13 Description all as per serial item No 11.00 here-in-before but 200mm bore. BI01010001010000000000000515BI0100001144 2 Each Job
14 14 Description all as per serial item No 11.00 here-in-before but 150mm bore. BI01010001010000000000000515BI0100001145 2 Each Job
15 15 Taking out old cracked/old unserviceable CI/DI/MS/GI pipe ,300 mm bore with all fittings after removing lead/tyton joints complete all as specefied and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001146 120 RM
16 16 Supply, laying, jointing and testing ERW MS pipe class 'B' pipe 300 mm bore of thickness 6 mm with permissible tolerance + 10% confirming to IS-3589 with all fittings such as bends (any type, radius or angle), Tapers any type (straight, bend, increasing, decreasing or double socket etc) TEE pieces single branch, 'Y' JUNCTION, double branch, cross collars, cap and plugs complete with all welding / threading works and jointing material laid in trenches/along road/ on surface/slopes/pillars/culverts/causways, (Excavation and earthwork will be measured and paid seperately) all as specified and directed. \nNote:- \n(i) All standard fittings such as bends, Tee pieces, collars, elbow, tail piece etc jointing are deemed to be included in the qouted item rate. \n(ii) Jointing of pipe line will be done through welding only. Payment of welding paid separately. BI01010001010000000000000515BI0100001147 120 RM
17 17 M&L for circular welding of 300 mm ERW pipe at site including surface preparation and all necessary T&P required for welding at site with electric supply through generator set and welding at site including testing of joints after completion of the welding, complete all as specified. BI01010001010000000000000515BI0100001148 24 Each
18 18 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001149 56 Cum
19 19 Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001150 49 Cum
20 20 Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001151 7 Cum
21 21 M&L for replacement of Cast Iron Non return valve, conforming to IS-5312, suitable for 300 mm bore pipe, heavy duty ,both end flanged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket with nuts, bolts and washers, welding wk including taking down old unsv complete all as specified and directed by Engr-in-charge.\nMake: Kirloskar/LeaderL&T BI01010001010000000000000515BI0100001152 1 Each
22 22 M&L for replacement of Cast Iron Non return valve, conforming to IS-5312, suitable for 250 mm bore pipe, heavy duty ,both end flanged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket with nuts, bolts and washers, welding wk including taking down old unsv complete all as specified and directed by Engr-in-charge.\nMake: Kirloskar/Leader/L&T/Zoloto BI01010001010000000000000515BI0100001153 1 Each
23 23 M&L for replacement of Cast Iron Non return valve, conforming to IS-5312, suitable for 200 mm bore pipe, heavy duty ,both end flanged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket with nuts, bolts and washers, welding wk including taking down old unsv complete all as specified and directed by Engr-in-charge.\nMake: Kirloskar/Leader/L&T/Zoloto BI01010001010000000000000515BI0100001154 1 Each
24 24 M&L for replacement of Cast Iron Non return valve, conforming to IS-5312, suitable for 150 mm bore pipe, heavy duty ,both end flanged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket with nuts, bolts and washers, welding wk including taking down old unsv complete all as specified and directed by Engr-in-charge.\nMake: Kirloskar/Leader/L&T/Zoloto BI01010001010000000000000515BI0100001155 1 Each
25 25 S&F in replacement Cast Iron sluice valve of size 300 mm (PN 1.6) (ISI Marked) with iron wheel head, both end flanged, stainless steel spindle, non rising type complete with Neoprene rubber gasket, nuts, bolts and washers, necessary welding wk etc.including taking down old unsv complete all as specified and directed by Engr-in-charge.\nMake: Kirloskar/Leader/L&T/Zoloto BI01010001010000000000000515BI0100001156 1 Each
26 26 Description all as per serial item No 25.00 here-in-before but sluice valve of size 250 mm. BI01010001010000000000000515BI0100001157 1 Each
27 27 Description all as per serial item No 25.00 here-in-before but sluice valve of size 200 mm. BI01010001010000000000000515BI0100001158 1 Each
28 28 Description all as per serial item No 25.00 here-in-before but sluice valve of size 150 mm. BI01010001010000000000000515BI0100001159 2 Each
29 29 Description all as per serial item No 25.00 here-in-before but sluice valve of size 100 mm. BI01010001010000000000000515BI0100001160 2 Each
30 30 Description all as per serial item No 25.00 here-in-before but sluice valve of size 80 mm. BI01010001010000000000000515BI0100001161 2 Each
31 31 S&F in replacement of CI foot valve flanged type 250 mm size with nut bolts and washer etc complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001162 1 Each
32 32 S&F in replacement of CI foot valve flanged type 200 mm size with nut bolts and washer etc complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001163 1 Each
33 33 S&F in replacement of CI foot valve flanged type 150 mm size with nut bolts and washer etc complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001164 1 Each
34 34 M&L for replacement of cast iron air release valve of size 100mm dia with two air outlets including all jointing materials like high pressure rubber gasket, nuts, bolts, washers and for boring 150mm dia to 300mm dia pipe with arrangement for fixing complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001165 1 Each
35 35 M&L for replacement of cast iron air release valve of size 80mm dia with two air outlets including all jointing materials like high pressure rubber gasket, nuts, bolts, washers and for boring 80mm dia to 150mm dia pipe with arrangement for fixing complete all as specified and directed by Engr-in-charge. BI01010001010000000000000515BI0100001166 1 Each
36 36 M&L for cutting of existing road for crossing of underground MS/CI/DI/GI tubing of any size including necessary excavation and earth work, repairing/making goods the disturbed surfaces as per existing with pre mix bituminous carpet complete all as specified and directed . BI01010001010000000000000515BI0100001167 10 Sqm
37 37 Decoupling, disconnecting suction line and discharge line taking down from foundation bolts, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity 200 to 270 HP complete all as specified and directed by Engr-in-charge.\nNotes: -\n(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates.\n(ii) S&F of parts shall be measured and paid separately under respective item of sch A. BI01010001010000000000000515BI0100001168 5 Each Job
38 38 Description all as per serial item No 37.00 here-in-before but capacity 170 HP. BI01010001010000000000000515BI0100001169 3 Each Job
39 39 Description all as per serial item No 37.00 here-in-before but capacity 75/100 HP. BI01010001010000000000000515BI0100001170 4 Each Job
40 40 Supply only Pump impeller made out of Bronze in repair for single/double/multistage pumps of capacity 200-270 HP as per manufacturer's composition of existing make of pump all as specified and directed by engr-in-Charge. \nMake: Kirloskar BI01010001010000000000000515BI0100001171 4 Each
41 41 Description all as per serial item No 40.00 here-in-before but Pump shaft stainless steel shaft complete with check nut and keys BI01010001010000000000000515BI0100001172 3 Each
42 42 Description all as per serial item No 40.00 here-in-before but Tyre coupling/star coupling BI01010001010000000000000515BI0100001173 6 Each
43 43 Description all as per serial item No 40.00 here-in-before but Gland cup with nuts and bolts BI01010001010000000000000515BI0100001174 6 Each
44 44 Description all as per serial item No 40.00 here-in-before but Shaft sleeves BI01010001010000000000000515BI0100001175 6 Each
45 45 Description all as per serial item No 40.00 here-in-before but Welding remelting and turning finishing cutting of key ways in respect of pump shaft BI01010001010000000000000515BI0100001176 4 Each
46 46 Description all as per serial item No 40.00 here-in-before but Bearing housing BI01010001010000000000000515BI0100001177 3 Each
47 47 Supply only Pump impeller made out of Bronze in repair for single/double/multistage pump of capacity 170 HP as per manufacturer's composition of existing make of pump all as specified and directed by engr-in-Charge. \nMake: Kirloskar BI01010001010000000000000515BI0100001178 3 Each
48 48 Description all as per serial item No 47.00 here-in-before but Pump shaft stainless steel shaft complete with check nut and keys BI01010001010000000000000515BI0100001179 2 Each
49 49 Description all as per serial item No 47.00 here-in-before but Shaft sleeves BI01010001010000000000000515BI0100001180 2 Each
50 50 Description all as per serial item No 47.00 here-in-before but Casing bearing BI01010001010000000000000515BI0100001181 2 Each
51 51 Description all as per serial item No 47.00 here-in-before but Bearing housing BI01010001010000000000000515BI0100001182 2 Each
52 52 Description all as per serial item No 47.00 here-in-before but Tyre coupling/star coupling BI01010001010000000000000515BI0100001183 6 Each
53 53 Description all as per serial item No 47.00 here-in-before but Gland cup with nut and bolts BI01010001010000000000000515BI0100001184 3 Each
54 54 Description all as per serial item No 47.00 here-in-before but Welding remelting and turning finishing cutting of key ways in respect of pump shaft BI01010001010000000000000515BI0100001185 2 Each
55 55 Supply only Pump impeller made out of Bronze in repair for single/double/multistage stage pump of capacity 75/100 HP as per manufacturer's composition of existing make of pump complete all as specified and directed by Engr-in-charge.\nMake: Kirloskar BI01010001010000000000000515BI0100001186 4 Each
56 56 Description all as per serial item No 55.00 here-in-before but Pump shaft stainless steel shaft complete with check nut and keys BI01010001010000000000000515BI0100001187 2 Each
57 57 Description all as per serial item No 55.00 here-in-before but Shaft sleeves BI01010001010000000000000515BI0100001188 3 Each
58 58 Description all as per serial item No 55.00 here-in-before but Casing bearing BI01010001010000000000000515BI0100001189 2 Each
59 59 Description all as per serial item No 55.00 here-in-before but Bearing housing BI01010001010000000000000515BI0100001190 2 Each
60 60 Description all as per serial item No 55.00 here-in-before but Tyre coupling/star coupling BI01010001010000000000000515BI0100001191 3 Each
61 61 Description all as per serial item No 55.00 here-in-before but Gland cup with nut and bolts BI01010001010000000000000515BI0100001192 3 Each
62 62 Description all as per serial item No 55.00 here-in-before but Welding remelting and turning finishing cutting of key ways in respect of pump shaft BI01010001010000000000000515BI0100001193 1 Each
63 63 Disconnecting electric connection of 200-270 HP motor, removing the UNSV motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots, transporting back after repair/winding & re-assembling the same. Cost of loading, unloading & transportation shall be deemed included in the quoted rates complete all as specified and directed by Engr-in-charge.\nNote: - Winding of motor stator & rotor shall be measured & paid separately.\n(a) Rewinding of motor will be measured and paid separately under relevent item\n(b) The motor shall be squirrel cage/slip ring induction motor.\n(c) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed.\n(d) Replacement of u/s bearings and grease completely. BI01010001010000000000000515BI0100001194 4 Each Job
64 64 Description all as per serial item No 63.00 here-in-before but capacity 170 HP. BI01010001010000000000000515BI0100001195 3 Each Job
65 65 Description all as per serial item No 63.00 here-in-before but capacity 75/100 HP. BI01010001010000000000000515BI0100001196 2 Each Job
66 66 S&F in replacement of slipring made of copper suitable for as per existing model 200/250HP motor complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001197 2 Each Set
67 67 S&F in replacement of slipring made of copper suitable for as per existing model 170HP motor complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001198 1 Each Set
68 68 S&F in replacement of slipring made of copper suitable for as per existing model 75/100 HP motor complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001199 1 Each Set
69 69 S&F in replacement of Microprocessor based Power card for soft starter of capacity 270/250HP motor,Model-ATS-22, \nMake: Schneider all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001200 2 Each
70 70 Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of various capacity with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time complete all as specified and directed by Engr-in-Charge. \nNote: - Cost of labour for winding deemed to be included in the rate quoted. BI01010001010000000000000515BI0100001201 470 Kg
71 71 S&F in repair of Pump bearing No. 6307 C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001202 8 Each
72 72 S&F in repair of Pump bearing No. 6313 M/C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001203 8 Each
73 73 S&F in repair of Pump bearing No. 6314 2RS1/C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001204 7 Each
74 74 S&F in repair of Pump bearing No. 6309 M/C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001205 4 Each
75 75 S&F in repair of Motor bearing No. 6310 M/C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001206 4 Each
76 76 S&F in repair of Motor bearing No. 6311 C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001207 4 Each
77 77 S&F in repair of Motor bearing No. 6312 C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001208 4 Each
78 78 S&F in repair of Motor bearing No. 6314 C4 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001209 4 Each
79 79 S&F in repair of Motor bearing No. 6011 C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001210 4 Each
80 80 S&F in repair of Motor bearing No. 7308 BECBJ \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001211 4 Each
81 81 S&F in repair of Pump bearing No. 6408 C3 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001212 8 Each
82 82 S&F in repair of Pump bearing No. 22312 E \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001213 2 Each
83 83 S&F in repair of Pump bearing No. 3307 ATN9 \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001214 4 Each
84 84 S&F in repair of Pump bearing No. 7310 BECBJ \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001215 5 Each
85 85 S&F in repair of Motor bearing No. 7311 BECBJ \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001216 6 Each
86 86 S&F in repair of Motor bearing No. NU 304 ECP \nMake: SKF/NBC or equivalent BI01010001010000000000000515BI0100001217 4 Each
87 87 Disconnecting the electric connection of Battery charger 12 volt 200AH,20Amps and tranportation civil workshop for repair. Rewinding of primary and secondary winding of battery charger complete with existing gauge of superior quality copper winding wire, insulating material,varnish binding of winding, replacement of Selector switch, Print circuit board complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001218 3 Each Job
88 88 M&L in replacement of PVC insulated heavy duty industrial cables single core copper conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 95 sqmm inculding taking down existing old unserviceable cable complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001219 50 RM
89 89 M&L in replacement of PVC insulated heavy duty industrial cables single core copper conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 150 sqmm inculding taking down existing old unserviceable cable complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001220 50 RM
90 90 S&F in replacement of OFF load change over switch 400 Amps, 415 volts 4 pole side handle operated with stainless steel enclosure inculding taking down the old existing change over switch complete all as specified and directed by Engr-in-Charge. \nMake: Havells Cat part No.IHCFFE0400 or eqivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001221 1 Each
91 91 S&F in replacement of OFF load change over switch 800 Amps, 415 volts 4 pole side handle operated with stainless steel enclosure inculding taking down the old existing change over switch complete all as specified and directed by Engr-in-Charge. \nMake: Havells Cat part No.IHCFFE0800 or eqivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001222 1 Each
92 92 M&L for replacement of MCCB 400 Amps breaking capacity 36KA, 415 Volt, Ics 100 % of Icu 50 HZ conforming to IS-13947, 4 pole with adjustable thermal and fixed magnetic including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. \nMake: Havells cat part No IHLLSEBF0400 or eqivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001223 1 Each
93 93 M&L for replacement of MCCB 400 Amps breaking capacity 36KA, 415 Volt, Ics 100 % of Icu 50 HZ conforming to IS-13947, 3 pole with adjustable thermal and fixed magnetic setting including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.\nMake: Havells cat part No IHLLSEBT0400 or eqivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001224 1 Each
94 94 M&L for replacement of MCCB 630Amps breaking capacity 36 KA, 415 Volt, Ics 100% of Icu 50 HZ conforming to IS-13947, 3 pole with adjustable thermal and fixed magnetic setting including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.\nMake: Havells cat part No IHLLSEBT0630 or eqivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001225 1 Each
95 95 M&L for replacement of MCCB 800 Amps breaking capacity 35/36 KA, 415 Volt, Ics 75% of Icu 50 HZ conforming to IS-13947, 4 pole with adjustable thermal and fixed magnetic setting including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.\nMake: Havells cat part No IHLCNF0800 or eqivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001226 1 Each
96 96 S&F in replacement of power contactor 3 pole AC control conformance to IEC 60947-4-1, CE marking, current rating 115 Amp AC-3, suitable for 75 HP capacity complete all as specified and directed by Engr-in-Charge. \nMake: Havells cat part No IHPAA115100 or equivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001227 1 Each Set
97 97 S&F in replacement of power contactor 3 pole AC control conformance to IEC 60947-4-1, CE marking, current rating 265 Amp AC-3, suitable for 180 HP capacity complete all as specified and directed by Engr-in-Charge. \nMake: Havells cat part No IHPAA265300 or equivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001228 1 Each Set
98 98 S&F in replacement of power contactor 3 pole AC control conformance to IEC 60947-4-1, CE marking, current rating 400 Amp AC-3, suitable for 270 HP capacity complete all as specified and directed by Engr-in-Charge. \nMake: Havells cat part No IHPAA400500 or equivalent make in Schneider/Legrand BI01010001010000000000000515BI0100001229 1 Each Set
99 99 S&F in replacement of Fully automatic star delta motor starter in sheet steel enclosure type MN 65 with single phase protection feature motor rating AC 3 phase 415 volts, 50 Hz for motor of capacity 75 HP as per cat part No IHPASDYF* complete all as specified and directed by Engr-in-Charge. \nMake: Havells complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001230 2 Each
100 100 S&F in replacement of MS stud bolts of existing size with nuts suitable for pumps and motors of various capacity complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001231 35 Kg
101 101 Repair to micro processor based power card, control card of soft starter of 250/270 HP motors complete all as specified and directed by Engr-in-Charge. \nMake: Schneider Model ATS 22 all as specified and as directed by Engr-in-Charge. BI01010001010000000000000515BI0100001232 5 Nos
102 102 S&F in repair of 1KVA control transformer with output rating 220 volts for protection of soft starters against surges complete all as specified and directed by Engr-in-Charge. \nMake: SKC or equivalent as directed by Engr-in-Charge. BI01010001010000000000000515BI0100001233 10 Nos
103 103 S&F of Lead for joints complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001234 65 Kg
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail