Supplying Erection Testing And Commissioning Medical Equipments And Operation Theatre Light In Connection With The Modernization Of Gynec Block-Emergency Ot And Labour Room As Per Laqshya At Taluk Hospital , Kadakkal . Supplying Erection Testing And Comm, Kadakkal, Kollam-Kerala

Kerala State Nirmithi Kendra has published Supplying Erection Testing And Commissioning Medical Equipments And Operation Theatre Light In Connection With The Modernization Of Gynec Block-Emergency Ot And Labour Room As Per Laqshya At Taluk Hospital , Kadakkal . Supplying Erection Testing And Comm. Submission Date for this Tender is 07-07-2020. Medical Equipment Tenders in Kadakkal, Kollam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

24744480
Supplying Erection Testing And Commissioning Medical Equipments And Operation Theatre Light In Connection With The Modernization Of Gynec Block-Emergency Ot And Labour Room As Per Laqshya At Taluk Hospital , Kadakkal . Supplying Erection Testing And Comm
Open Tender
Indian
Kerala
Kadakkal, Kollam
07-07-2020

Tender Details

Supplying Erection Testing And Commissioning Medical Equipments And Operation Theatre Light In Connection With The Modernization Of Gynec Block-Emergency Ot And Labour Room As Per Laqshya At Taluk Hospital , Kadakkal . Supplying Erection Testing And Commissioning Medical Equipments And Operation Theatre Light As PerLaqshya Standards .

Key Value

Document Fees
INR 1250 /-
EMD
INR 15700.0 /-
Tender Value
INR 6.24 Lakhs /-

BOQ Items

Name of Work:Supply and installation 1 No. of 10m height 6x150W High Mast Light at Kottakkadav Junction in Kadalundi Grama Panchayath and 6 Nos. of 8m height 4x150W Mini mast light at Kallampara and Kothorthod in Feroke Municipality and Kottamangalam in Ramanattukara Municipality in Beypore Legislative Assembly Constituency
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and installation of 10m High Mast system BI01010001010000000000000515BI0100001113
2 1.001 90.15.2.2\nSupply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and\nincluding round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters BI01010001010000000000000515BI0100001114 1 each
3 1.002 90.15.4.9\nSupply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) BI01010001010000000000000515BI0100001115 6 each
4 1.003 od194394/2019_2020\nSupply and installation of Twin unit aviation LED obstruction light with stand yellow-painted die-cast aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LED lamp\n BI01010001010000000000000515BI0100001116 1 each
5 1.004 90.14.1.2\nFabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using\n1.6mm CRCA sheet, powder coated (excluding base frame) BI01010001010000000000000515BI0100001117 2.5 sqm
6 1.005 90.14.3.2\nSupply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet BI01010001010000000000000515BI0100001118 10 m
7 1.006 od194395/2019_2020\nSupply and fixing of 2 nos.of 25A 3 Pole AC 1 rated power contactor, Selector switch for motor control, supply and fixing flush head push button NO-NC, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. BI01010001010000000000000515BI0100001119 1 each
8 1.007 od194396/2019_2020\nSupply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, Suitable\nCopper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, OBO Bettermann makes V25- B+ C/1+ NPE (switching/lightning protection) for single-phase protection. BI01010001010000000000000515BI0100001120 1 each
9 1.008 od194397/2019_2020\nSupply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. BI01010001010000000000000515BI0100001121 1 each
10 1.009 90.14.5\nSupply and fabrication conveyance and installation of angle iron frame work for wall mounting panel\nboard BI01010001010000000000000515BI0100001122 15 kg
11 1.01 2.14.2\nSupplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001123 1 each
12 1.011 2.10.3\nSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole BI01010001010000000000000515BI0100001124 2 each
13 1.012 2.10.1\nSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole BI01010001010000000000000515BI0100001125 1 each
14 1.013 2.12.1\nSupplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections testing and commissioning etc as required BI01010001010000000000000515BI0100001126 1 each
15 1.014 90.6.5.11\nSupply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm BI01010001010000000000000515BI0100001127 18 m
16 1.015 5.3\nEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. BI01010001010000000000000515BI0100001128 2 set
17 1.016 90.16.4.2\nSupply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip BI01010001010000000000000515BI0100001129 9 m
18 1.017 90.16.1.3\nSupply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG) BI01010001010000000000000515BI0100001130 16 m
19 1.018 90.16.5.3\nSupply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) BI01010001010000000000000515BI0100001131 8 each
20 1.019 90.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm 8 BI01010001010000000000000515BI0100001132 8 m
21 1.02 90.12.9.2\nSupplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size BI01010001010000000000000515BI0100001133 8 m
22 1.021 9.1.2\nSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq.mm (19mm) BI01010001010000000000000515BI0100001134 8 set
23 2 Civil works BI01010001010000000000000515BI0100001135
24 2.01 2.6.1\nEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas\n(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil BI01010001010000000000000515BI0100001136 2.734 cum
25 2.02 4.1.8\nProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001137 0.3 cum
26 2.03 5.9.1\nCentering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001138 5.4 sqm
27 2.04 5.22.6\nSteel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001139 100 kg
28 2.05 5.1.2\nProviding and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001140 1.3 cum
29 2.06 13.1.1\n12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) BI01010001010000000000000515BI0100001141 1.7 sqm
30 2.07 2.25\nFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. BI01010001010000000000000515BI0100001142 1.48 cum
31 2.08 Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt). BI01010001010000000000000515BI0100001143 1 LS
32 2.09 Fabrication ,supply, conveyance and installation of Granite name board indicating the cost\ninvolved, the commencement, completion and inauguration date etc. BI01010001010000000000000515BI0100001144 1 LS
33 2.1 Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut\n&amp; Bolt BI01010001010000000000000515BI0100001145 1 LS
34 3 Supply and installation of 8m High Mast system BI01010001010000000000000515BI0100001146
35 3.01 90.15.1.1\nSupply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mmsuitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters BI01010001010000000000000515BI0100001147 6 each
36 3.02 90.15.4.9\nSupply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) BI01010001010000000000000515BI0100001148 24 each
37 3.03 90.14.1.2\nFabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used for\npanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)\n2 2.000 BI01010001010000000000000515BI0100001149 12 each
38 3.04 90.14.3.2\nSupply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet BI01010001010000000000000515BI0100001150 42 sqm
39 3.05 90.14.5\nSupply and fabrication conveyance and installation of angle iron frame work for wall mounting panel\nboard BI01010001010000000000000515BI0100001151 60 kg
40 3.06 od194185/2019_2020\nSupply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, Suitable\nCopper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, OBO Bettermann makes V25- B+ C/1+ NPE (switching/lightning protection) for single-phase protection. BI01010001010000000000000515BI0100001152 6 each
41 3.07 od194186/2019_2020\nSupply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable BI01010001010000000000000515BI0100001153 6 each
42 3.08 2.14.2\nSupplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001154 6 each
43 3.09 2.10.3\nSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole BI01010001010000000000000515BI0100001155 6 each
44 3.1 2.10.1\nSupplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole BI01010001010000000000000515BI0100001156 6 each
45 3.11 2.12.1\nSupplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections testing and commissioning etc as required BI01010001010000000000000515BI0100001157 6 each
46 3.12 90.6.5.11\nSupply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm BI01010001010000000000000515BI0100001158 240 m
47 3.13 5.3\nEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. BI01010001010000000000000515BI0100001159 6 set
48 3.14 90.16.4.2\nSupply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip BI01010001010000000000000515BI0100001160 27 m
49 3.15 90.16.1.3\nSupply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG) BI01010001010000000000000515BI0100001161 48 m
50 3.16 90.16.5.3\nSupply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) BI01010001010000000000000515BI0100001162 36 each
51 3.17 90.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm 8 BI01010001010000000000000515BI0100001163 36 m
52 3.18 90.12.9.2\nSupplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size BI01010001010000000000000515BI0100001164 36 m
53 3.19 9.1.2\nSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq.mm (19mm) BI01010001010000000000000515BI0100001165 12 set
54 4 Civil works BI01010001010000000000000515BI0100001166
55 4.01 2.6.1\nEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas\n(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil BI01010001010000000000000515BI0100001167 8.4 cum
56 4.02 4.1.8\nProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001168 0.6 cum
57 4.03 5.9.1\nCentering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001169 22.2 sqm
58 4.04 5.22.6\nSteel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001170 180 kg
59 4.05 5.1.2\nProviding and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001171 3.6 cum
60 4.06 13.1.1\n12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) BI01010001010000000000000515BI0100001172 6 sqm
61 4.07 2.25\nFilling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. BI01010001010000000000000515BI0100001173 5.226 cum
62 4.08 Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt). BI01010001010000000000000515BI0100001174 6 LS
63 4.09 Fabrication ,supply, conveyance and installation of Granite name board indicating the cost\ninvolved, the commencement, completion and inauguration date etc. BI01010001010000000000000515BI0100001175 6 LS
64 4.1 Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut\n&amp; Bolt BI01010001010000000000000515BI0100001176 6 LS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy