Annual Repair Maintenance Of Various E And M Installations I/C Water Coolers , Unitary Ac Units , Fire System Etc Of Operational Area Including Technical Building And Nav-Aids Sites At Jaipur International Airport ( 2020-2021 ) ., Jaipur Airport-Rajasthan

Airports Authority Of India has published Annual Repair Maintenance Of Various E And M Installations I/C Water Coolers , Unitary Ac Units , Fire System Etc Of Operational Area Including Technical Building And Nav-Aids Sites At Jaipur International Airport ( 2020-2021 ) .. Submission Date for this Tender is 13-07-2020. Tanks and Cylinders Tenders in Jaipur Airport Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

24743620
Annual Repair Maintenance Of Various E And M Installations I/C Water Coolers , Unitary Ac Units , Fire System Etc Of Operational Area Including Technical Building And Nav-Aids Sites At Jaipur International Airport ( 2020-2021 ) .
Open Tender
NCB
Rajasthan
Jaipur Airport
13-07-2020

Tender Details

Armo Of Various E And M Installations I / C Water Coolers , Unitary Ac Units , Fire System Etc Of Operational Area Including Technical Building And Nav-Aids Sites At Jaipur International Airport ( 2020-2021 ) ., Sh 1 : Supply Of Manpower ( Item No . 1 To 4 ) Providing One Number High-Skilled Manpower In One Shift Of 8 Hour On All Days Including Sundays & Holidays ( Excluding Weekly Off Day ) For One Month For Operation & Maintenance Of Electrical Installations . , Providing Fifteen Number Skilled Manpower In One Shift Of 8 Hour On All Days Including Sundays & Holidays ( Excluding Weekly Off Day ) For One Month For Operation & Maintenance Of Electrical Installations . , Providing Four Number Semi-Skilled Manpower In One Shift Of 8 Hour On All Days Including Sundays & Holidays ( Excluding Weekly Off Day ) For One Month For Operation & Maintenance Of Electrical Installations . , Providing Thirteen Number Un-Skilled Manpower In One Shift Of 8 Hour On All Days Including Sundays & Holidays ( Excluding Weekly Off Day ) For One Month For Operation & Maintenance Of Electrical Installations . , Sh 2 : Cmc Of Fire Fighting System ( Item No . 5 To 16 ) Comprehensive Maintenance Of Fire Fighting System At New Technical Block Includes Main Fire Fighting Pump , Jockey Pump , Main Control Panel , Diesel Engine Pumpset , Hose Cabinet , Hose Couplings , Yard Hydrants , Piping , All Type Of Valves , Wet Riser / Sprinklers System Etc . As Per Inventory Shown In Annexure-C . , Comprehensive Maintenance Of Fire Detection And Alarm System At New Technical Block Includes Main Control Panel , Local Control Panel , All Zone Cards , Smoke Detectors , Electric Hooters , Response Indicators , Manual Call Points , Repeater Panels , Fire Dampers , Pa System Etc . As Per Inventory Shown In Annexure-D . , Comprehensive Maintenance Of Fire Detection And Alarm System At Nav-Aids Sites Includes Alarm Panel With Inbuilt Auto Dialer , Optical Smoke Detector , Sounder , Response Indicators As Per Inventory Shown In Annexure-E . , Comprehensive Maintenance Of Fire Fighting System At Atc Tower & Equipment Room Includes 2 Zone Panel , Novec 1230 Filled Gas Cylinder , Discharge & Actuation Hoses , Nozzles , Detectors Piping , All Valves Etc . Including Filling Of Gas As And When Required As Per Inventory Shown In Annexure-F . , Supply Of 02 Zone Loop Fire Detection And Alarm Panel Including Autodialer , Built-In Charger And Battery Backup Requirements Etc . Complete As Required . , Installation , Testing And Commissioning Of 02 Zone Loop Fire Detecton And Alarm Panel At Different Locations Complete As Required . , Supply Of Conventional Type Photo Electric Fire Detectors With All Accessories Like Base , Box Compatible To 02 Zone Loop Fire Detecton And Alarm Panel Complete As Required . , Installation , Testing And Commissioning Of Fire Detectors At Different Locations Complete As Required . , Supply Of Conventional Type Hooter / Sounder Compatible To 02 Zone Loop Fire Detector And Alarm Panel Complete As Required . , Installation , Testing And Commissioning Of Hooter / Sounder At Different Locations Complete As Required . , Supply Of 1 . 1 Kv Grade , Pvc / Xlpe Insulated , Frls Copper Conductor Armoured Cable Of Size 2 X 1 . 5 Sqmm Conforming To Is:7098 ( Part-I ) With Uptodate Ammendments Complete As Required . , Laying Of 1 . 1 Kv Grade , Pvc / Xlpe Insulated , Frls Copper Conductor Armoured Cable Of Size 2 X 1 . 5 Sqmm On Surface / Existing Pipes Etc Complete As Required . , Sh 3 : Cmc Of Different Type Of Acs And Water Cooler ( Item No . 17 To 31 ) Comprehensive Maintenance Of Different Make 1 . 5 Tr Window Type Airconditioner Including Filling Of Gas & Comprehensive Maintenance Of Voltage Stablizer For One Unit Per Month . , Comprehensive Maintenance Of Different Make 1 . 5 Tr Split Type Airconditioner Including Filling Of Gas & Comprehensive Maintenance Of Voltage Stablizer For One Unit Per Month . , Comprehensive Maintenance Of Different Make 2 . 0 Tr Split Type Airconditioner Including Filling Of Gas & Comprehensive Maintenance Of Voltage Stablizer For One Unit Per Month . , Comprehensive Maintenance Of Different Make 3 . 0 / 3 . 5 / 4 . 0 Tr Tower-Split Type Airconditioner Including Filling Of Gas For One Unit Per Month . , Comprehensive Maintenance Of 17 . 0 Tr Ductable Split-Type Airconditioner Including Filling Of Gas For One Unit Per Month . , Comprehensive Maintenance Of Different Make Water Cooler Of Different Capacity ( Upto 150 Ltr / 150 Ltr Capacity ) Including Filling Of Gas For One Unit Per Month . , Dismantling Of 1 . 5Tr Window Ac Complete In All Respect As Required And Depositing To Aai Store With Inventary ( Transportation Will Be Provided By Aai ) . , Dismantling Of 1 . 5Tr / 2 . 0Tr Split Ac Complete In All Respect As Required And Depositing To Aai Store With Inventary ( Transportation Will Be Provided By Aai ) . , Dismantling Of 3 . 0Tr / 3 . 5 Tr Single / Three Phase Split Ac Complete In All Respect As Required And Depositing To Aai Store With Inventary ( Transportation Will Be Provided By Aai ) . , Supply And Fixing Of Suitable Size Suction And Discharge Copper Reffigerant Piping Including Insulation Suitable For 1 . 5Tr / 2 . 0Tr Split Ac Units . , Supply And Fixing Of Suitable Size Suction And Discharge Copper Reffigerant Piping Including Insulation Suitable For 3 . 0 Tr / 3 . 5 Tr Split Tower Ac Units . , Supply And Fixing Of Suitable Size Pvc Drain Piping For 1 . 5Tr / 2 . 0Tr / 3 . 0Tr / 3 . 0Tr / 3 . 5Tr Split Ac Units . , Installation , Testing And Commissioning Of 1 . 5Tr Window Ac Including Minor Civil Work Complete In All Respect As Required Including Charging , Pressure Testing Of Gas Etc . , Installation , Testing And Commissioning Of 1 . 5Tr / 2 . 0 Tr Split Ac Including Minor Civil Work Complete In All Respect As Required Including Charging , Pressure Testing Of Gas Etc . , Installation , Testing And Commissioning Of 3 . 0Tr / 3 . 5 Tr Vertical Tower Split Ac Including Minor Civil Work Complete In All Respect As Required Including Charging , Pressure Testing Of Gas Etc . , Sh 4 : Ist Of Ht Equipments ( Item No . 32 To 37 ) Inspection , Servicing And Testing Of Crompton Make Vacuum Circuit Breaker ( 11Kv , 800 Amps Capacity ) From The Manufacturer From The Authorised Service Dealer Of Manufacturer . Cost Of Spares ( If Required ) Shall Be Paid Extra By Aai . , Inspection , Servicing And Testing Of Kirloskar Make Sf6 Breaker ( 33Kv , 1250 Amp Capacity ) From The Manufacturer From The Authorised Service Dealer Of Manufacturer . Cost Of Spares ( If Required ) Shall Be Paid Extra By Aai . , Supply And Refilling Of Sf6 Gas In 33 Kv Circuit Breaker Per Pole I / C Testing , Rectification Of Leakage Complete As Per Site Requirement . , Inspection , Servicing Of On Load Tapchanger ( Oltc ) Ctr Make Type En16 Fitted With 5Mva 33 / 11 Kv Kirlosker Make Transformer From Oem Or Authorised Service Center Of Oem Including Inspection And Testing Of Remote Tap Change Circuit ( Rtcc ) Panel Complete In All Respect As Required ( Cost Of Spare , If Required Shall Be Paid Extra By Aai ) . , Checking , Servicing Callibratiion & Testing Of Following Protecion Relays Provided On 33 Kv Sf6 Breaker Panel Complete As Per Site Requirement- A ) Numerical O / C & Earth Fault Relays ( 3 Oc + 1 Ef ) - 04 Nos . B ) Master Trip Relay - 04 Nos . C ) Trip Ckt Supervision Relay - 04 Nos D ) Aux Relay For Tx Protection - 04 Nos . E ) Earth Fault Relay For Tx Neutral - 02 Nos . F ) Bulchhoz Relay Trip / Alarm , Winding Temp . Trip / Alarm , Oil Temp . Trip / Alarm , Osr Trip / Alarm , Mog Alarm - 02 Set , Checking , Servicing , Callibration & Testing Of Following Protection Relays Provided On 11 Kv Vcb Breaker Panel Complete As Per Site Requirement . A ) Numerical O / C & Earth Fault Relays ( 3 0C + 1

Key Value

Document Fees
INR 1120 /-
EMD
INR 215223.0 /-
Tender Value
INR 1.07 Crore /-