| 1 | 1 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required.\n20 mm | | 500 | R. mtr. |
|---|
| 2 | 2 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required.\n25 mm | | 1200 | R. mtr. |
|---|
| 3 | 3 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required.\n32 mm | | 300 | R. mtr. |
|---|
| 4 | 4 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required.Gp-I\nShort point (up to 3 mtr.) | | 55 | P. point |
|---|
| 5 | 5 | Medium point (up to 6 mtr.) | | 90 | P. point |
|---|
| 6 | 6 | Long point (up to 10 mtr..) | | 150 | P. point |
|---|
| 7 | 7 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tles, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal,6 A two way Modular switch, Modular plate with grid plate, screws, making connections, testing etc. as required. Gp 1\nLong point (up to 10 mtr..) | | 4 | P. point |
|---|
| 8 | 8 | Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required.Gp-AI\nOn board | | 75 | P. point |
|---|
| 9 | 9 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.\n1 x 1.5 sq.mm | | 700 | Mtr. |
|---|
| 10 | 10 | 2 x 2.5 sq. mm. + 1x1.5sqmm | | 1450 | Mtr. |
|---|
| 11 | 11 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. | | 1300 | Mtr. |
|---|
| 12 | 12 | 4 x 6.0 sq.mm | | 250 | Mtr. |
|---|
| 13 | 13 | 1 x 4.0 sq.mm | | 200 | Mtr. |
|---|
| 14 | 14 | 4 x 10.0 sq.mm | | 250 | Mtr. |
|---|
| 15 | 15 | 1 x 6.0 sq.mm | | 200 | Mtr. |
|---|
| 16 | 16 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.Gp-A1\nDouble door (Three phase)\n6 Way | | 4 | Each |
|---|
| 17 | 17 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.Gp-A1\nDouble door (Three phase)\n8 Way | | 6 | Each |
|---|
| 18 | 18 | P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing , phophatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.\nDouble door with Provision of Incomer MCCB 200/ 250 A Rating\n8 Way | | 1 | Each |
|---|
| 19 | 19 | P&F recessed mounting heavy duty sheet steel End Box for distribution board duly phophatised powder coated complete as required.\nFor TPN 6 way DB | | 4 | Each |
|---|
| 20 | 20 | For TPN 12 way DB / all VTPN DB | | 1 | Each |
|---|
| 21 | 21 | Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost of modular 16 amp. Switch and socket outlet , making connection , testing , etc. as required. | | 50 | Each |
|---|
| 22 | 22 | P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required.Gp-I\n5 step fan regulator 2 Module | | 65 | Each |
|---|
| 23 | 23 | P & F IS:371 marked 6 amp surface type ceiling rose including making connection testing etc. as required. Gp 1 | | 75 | Each |
|---|
| 24 | 24 | P & F ISI marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. Gp 1 | | 35 | Each |
|---|
| 25 | 25 | P & F ISI marked single tone electronic call bell including making connection testing etc. as required. Gp-I | | 10 | Each |
|---|
| 26 | 26 | Making of hole in wall of required size for housing exhaust fan and making good the same, with cement plaster as required of following size:\nUp to 457 mm size | | 10 | Each |
|---|
| 27 | 27 | P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . | | 65 | Each |
|---|
| 28 | 28 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. (Group-I)\n9.0 mm thick | | 6 | Sqm |
|---|
| 29 | 29 | P & F following size hot dip galvanized M.S. box of 20 SWG with earthing terminal in recess/ surface suitable for modular accessories as required.\n1-2 Module | | 4 | Each |
|---|
| 30 | 30 | P & F following size mounting grid plates with cover plates Gp-I\n1/2 Module | | 4 | Each |
|---|
| 31 | 31 | P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required.Gp-I\nT.V. coaxial socket | | 4 | Each |
|---|
| 32 | 32 | Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required Gp 1. | | 1000 | Mtr. |
|---|
| 33 | 33 | Supply and Installation of Information outlets made of high impact plastic body ABS FR Grade with spring loaded collapsible shutters in jack Recess, suitable for Cat 6 application complying to latest ammendments EIA/ TIA 568 B.2-1 Specifications in existing modular /MS Boxes along with necessory connections as required | | 24 | Each |
|---|
| 34 | 34 | Supply & fixing of Faceplate for Flush / Surface Mount Information Outlets Single Aperture with screw hole covers & Icon Tree Size 86mmX86mm\nSingle Aperture | | 24 | Each |
|---|
| 35 | 35 | Supply , Installation, Testing and Comissioning of Rack mounted 19\", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps.\n24 Ports | | 1 | Each |
|---|
| 36 | 36 | Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG , Cat 6 UTP, flexible , Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief transparent boots as per TIA /EIA 568 B.2-1 Specifications.\n1 Mtr/3 ft | | 20 | Each |
|---|
| 37 | 37 | Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG , Cat 6 UTP, flexible , Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief transparent boots as per TIA /EIA 568 B.2-1 Specifications.\n2 Mtr / 7 ft | | 4 | Each |
|---|
| 38 | 38 | Supply , Installation, Testing and Comissioning of Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable\n12 U(44 mm ) wall mounted | | 1 | Each |
|---|
| 39 | 39 | P & F of IP 20 LED tube light 20 watt with external batten made from CRCA sheet steel suitable to replace T-B/T-12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 Lm/ watt minimum expected life time of 25000 burning hours, CCT 5700 I( ANSI, CRI 80, driver efficiency >850%, Life expectancy of driver min 30000 hrs. PF 0,95 at full load/ 230 volt AC | | 75 | Each |
|---|
| 40 | 40 | P & F of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external BIS certified 2.5 KV surge protected driver having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of = 100 lm / watt and life time of minimum 35000 Burning Hours with 70% of intial Lumen maintaned, CCT 3000°K / 4000°K / 6000°K , maximum power consumption should not more than the specified rating and Fixture shall be of CE complianed.\nSurface Mounting\nLED Downlight 18/20W | | 40 | Each |
|---|
| 41 | 41 | LED Downlight 12 W | | 15 | Each |
|---|
| 42 | 42 | LED Downlight 6 W | | 20 | Each |
|---|
| 43 | 43 | P & F 1200mm sweep BEE 5 star rated double ball bearing capacitor start Aluminium body & blade ceiling fan complying to IS 374:L979, t/p 50 watt at max speed &z3ovolt, air delivery > 210 cMM, speed > 330 RPM with down rod upto 30 cm with 3 x 1.s sqmm pvc insulated flexible copper conductor making connection testing etc as required.G-1 | | 65 | Each |
|---|
| 44 | 44 | P & F 9/11/13/ Watt CFL mirror light with CRCA powder coated housing, diffuser, end covers, copper ballast, holder prewired upto terminal block including making connection testing etc. as required(without tube) (Group-I) | | 4 | Each |
|---|
| 45 | 45 | P&F of Double ball bearing, capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible copper conductor ,making connections, testing etc. as required. GP 1\n300 mm sweep | | 5 | Each |
|---|
| 46 | 46 | P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. \nUp to 380 mm size | | 10 | Each |
|---|
| 47 | 47 | P&F of Heavy duty capacitor start, Double ball bearing 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required.\n300 mm sweep(900/1400 RPM) | | 5 | Each |
|---|
| 48 | 48 | SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required.\nWith Thermal Magnetic release\n250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu | | 1 | Each |
|---|
| 49 | 49 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Gp- A1\nsingle pole MCB. : \n 6 A to 32 A rating | | 82 | Each |
|---|
| 50 | 50 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Gp- A1\nFour pole MCB \n 40 A 63 A rating | | 4 | Each |
|---|
| 51 | 51 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Gp- A1\nTriple pole MCB\n 40 A 63 A rating | | 10 | Each |
|---|
| 52 | 52 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Gp- A1\nDouble pole MCB\n 40 A 63 A rating | | 6 | Each |
|---|
| 53 | 53 | P&F of RCBO with overload, short-circuit and earth leakage protection ISI marked (IS12640)/ conforming to IEC 61009/1 complete in all respect including making connections, testing etc. as required.\nTwo pole 100/300mA sensitivity\n40 A rating | | 6 | Each |
|---|
| 54 | 54 | P&F of RCBO with overload, short-circuit and earth leakage protection ISI marked (IS12640)/ conforming to IEC 61009/1 complete in all respect including making connections, testing etc. as required.\nFour pole 100/300 mA sensitivity\n63 A rating | | 4 | Each |
|---|
| 55 | 55 | P&F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming etc. as required (Group-II)\nOne day reserve (mechanical type ) | | 1 | Each |
|---|
| 56 | 56 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.\n6.0 Sq.mm\n4 core | | 150 | Mtr. |
|---|
| 57 | 57 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.\n10.0 Sq.mm\n4 core | | 150 | p.MTR |
|---|
| 58 | 58 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.\n50.0 Sq.mm\n3.5 core | | 150 | Mtr. |
|---|
| 59 | 59 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.\n4 x 6.0 sq.mm | | 20 | Set |
|---|
| 60 | 60 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.\n4 x 10.0 sq.mm | | 24 | Set |
|---|
| 61 | 61 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia.\n120 / 103.5 mm | | 150 | Mtr. |
|---|
| 62 | 62 | Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes.\nWith Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating\nGI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip | | 2 | Each |
|---|
| 63 | 63 | S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.\n32mm x6mm G.I. ( Hot Dipped ) Strip | | 15 | P.mtr |
|---|
| 64 | 64 | Supply & Fixing ISI marked ( IS : 15683 ) Portable fire Extinguisher, Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia. min. 600 mm long & complete in all respects including initial fill with C02 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667and wall suspension bracket. Capacity 4.5 Kg. | | 4 | Each |
|---|
| 65 | 65 | Supply & Fixing ISI marked ( IS : 15683 ) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity.\n4 kg | | 4 | Each |
|---|
| 66 | 66 | Supply and erection of GI Octagonal / Conical pole of following length and dimension as per table E-10 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning.\nOctagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table E - 10 for specs.)\n8 Mtr. | | 4 | Each |
|---|
| 67 | 67 | Supply, Erection and Fixing of hot dipped galvanised Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles\nSingle arm overhang | | 4 | Mtr. |
|---|
| 68 | 68 | P&F of IP65 protected LED Street Light Luminaire on existing bracket. Fixture made of powder coated single piece pressure die cast aluminum with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover ( from 45W onwards ) and should be secondary lens on each LED . The System level Luminaire efficacy >=100 with High Power LEDs of CREE/NICHIA/OSRAM/PHILIPS/SEOUL make is to be used .The LED Driver shall be BIS certified and Input Voltage AC 110 to 270 V AC with Input Frequency 50Hz±3% Power Factor >0.95 Driver Efficiency >85% , THD(I) <10% Humidity 10% to 90% RH Working Temp -20C to 50C . Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% initial lumens maintained ,Rendering Index >75% .Surge protection shall be min = 5 KV internal and min 10 KV external. Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixtures shall be CE complianed.\nLED Street Light fixture 60 Watt | | 6 | Each |
|---|
| 69 | 69 | S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required.\n32 mm Dia. | | 6 | Each |
|---|
| 70 | 70 | P & F energy efficient / energy saving 9 Watt IP 20 LED Bulb cool white, in existing holder / fixture as required, minimum 900 Lumen output, 25000 burning hours, CCT 5700 I( or 6500 I( [ as per direction of Engineer incharge), ANSI, Lamp efficacy minimum 100 lumen/Watt, CRI 80, Driver efficiency >850/0, PF 0.95 at full load/ 230 volt AC. | | 30 | Each |
|---|
| 71 | 71 | P & F of capacitor start, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required.\n400 mm sweep(Oscillating type) | | 6 | Each |
|---|
| 72 | 72 | SITC of RO water system with Filtration stage Particilate filter-Membrane life\nenhancer filter - sediment filter - Pre carbon filter -RO Membrane filter - Post carbon filter, Input power Rating - 230 v AC , 50 HZ, Percentage of Rejection TDS - 9oo/o or better having following features)Double purification by RO with ESS or latest technology with TDS indicator.Spin welded RO Membrane Housing to preventtempering. Push fit components for leak proof performance Fully automatic operation with auto start and auto off.SS/ABS construction for corrosion free\nlifespan. Equally suitable for water from all bore wells, overhead storage tanks, water\ntankers and even municipal taps.R0 Membrane Flushing - Auto Flush @ Every Start Every Stop and every One Hour of working for one minute. complete in all respect\nwith following capacity\nPurification capacity- 50 LPH, Duty Cycle 270-500liters/day | | 2 | Each |
|---|
| 73 | 73 | SITC of self contained drinking water cooler with energy efficient hermetic sealed type compressor, non cFC refrigerant suitable for operation on230v/LpH/50H2 ac supply, Full stainless steel [S30a)body and tank, stainless steel water tray, minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity\ncooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs | | 2 | Each |
|---|
| 74 | 74 | Supply, installation, Testing and Commissioning of IP-65/ROHS/CE compliant Integrated Solar Street Light fixture having die cast Aluminium body CNCASCS with integrated monocrystaline solar PV panel with lithiumILiFePO4) ferro Phosphate battery and comPliant to MNRE specifications / BIS approved .luminaire should be with secondary optic lenses for better distribution with delivered efficacy of > L00 Lumens per Watt,with minimum 40000 hrs. rated LamP Iife with LED's brand of Philips/Osram/Nichia/CreelSeoul and driver efficiency should be >B5o/o , CRI Microcontroller based high efficiency controller cum driver designed with automatic dimming function with PIR motion sensor ( full power lighting when a human move in the sensor range and only 300/o lighting when a human move out ) , Dusk to Down operation, working temperature t-l LOoC to [*) 55oC, with adjustable clamp suitable for pole/wall mounting complete in all respect with protection like short circuit, overload, reverse\npolarity and battery protections. Light coverage must be LZ} Degree or greater\ncomplete as required.\nCompact Solar LED Street Light-40 Wp(mono)18V /12.8 V 18 AH/25 W | | 4 | Each |
|---|
| 75 | 75 | Supply. Installation, Testing and Commissioning of 1.8 I(VA Pure Sinewave horne UPS \n/ Inverter with 2 numbers 150 AH tubular Battery for bacl<up. with following specifications :- SpecificationRating- 1.8 KVA Technology-DSP Pure Sinewave Technology-DSP Pure Sinewavel/P V- 120-2BOVAC (lnverter Model, 1B0V-250VAC\n[UPS Mode)O/P voltage-220VACVoltage Regulation:- +/- 50/o [0n Batt. Mode) Technology-DSP Pure Sinewavel/P V- 120-2B0VAC (lnverter Model, 1B0V-250VAC (UPS Mode)O/P voltage-Z20VACVoltage Regulation:- +/- 5o/o [0n Batt. Mode)O/Pfrequency:- 50 Hz +/- 1 Hz (Battery Model Over load capacity:- 11-0 o/o for 5 min. on mains mode Efficiency:- Better than 921/oCharging current :-7 A/10A/12A/15A/20A/25A (Programmable) D.C. Voltage:- 24V AH capacity:-3600VAHlndications:-Mains 0n, Inverter On, OfL, Low Battery, Battery ChargingProtections:- Rev Phase, S Ckt, Over Temp, O/L, Battery Loose Relative Humidity:- 95o/o\nRH Non-condensing operating Temperature:-0-50deg.c Safety Standards:-lEC/EN 60950EMC Std:-lEC-EN62040-1,, EN62040-2, EN62040-3, EN61000-4, EN60146 Certificates:- IS0 9001,1S0 14001,1S0 1B001,ROHS & CE | | 2 | Each |
|---|
| 76 | 76 | SITC of Air Cooled split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 4 Mtr (IDU to ODU), R-22/R-410 Refrigerant, Remote, suitable for 400/230V +10% of 50 Hz ,1 /3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / reciprocating / rotary compressor as specified.\n1.5 TR with 5 star rating of BEE | | 2 | Each |
|---|
| 77 | 77 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. | | 2 | Each |
|---|
| 78 | 78 | P&F metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without MCB) including making connections, testing etc.as required\nSingle / Double Pole (Three pin)\n20 A | | 2 | Each |
|---|
| 79 | 79 | Supply, Fixing and testing of following capacity wall mounted stablisers having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect\n4 kVA | | 2 | Each |
|---|
| 80 | 80 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , Painting etc. as required. | | 20 | Kg |
|---|