Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal
Tender Overview
Project Description
Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal , Taking Down And Dismantling Of Street Light Fittings Of Any Type Size And Model ( Ftl , Es , Hpsv , Mvl , Mh , Floodlight Fittings , Solar Light , ) , Removing Of Unserviceable Spares / Accessories For Repair / Replacement Of The Same Including Refixing Of Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) And Testing Complete All As Directed . Note : ( Spare / Parts Required For Repairing Of Fitting Will Be Issued / Paid Under Respective Items Of This Schedule ) , Taking Down , Dismantling And Necessary Repairing Of Led Street Light Fittings To Make Functional By Replacing Unserviceable Part Such As Pcb , Lens , Holder , Insulation Pad , Heatsink , Wire Connecting Terminal Etc As Existing Including Refixing Of Led Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) Including Supply And Fixing Of Pvc Sheathed Aluminium Conductor Mutistranded Cable Of 2 Single Core Of 2 . 5 Sqmm Of Min Length 8 Metre From Fitting To Electric Supply Source And Testing Complete All As Directed . , M&L For Taking Down Mh Light Fittings Mounting On Cage From High Mast Pole Of 12 . 5 / 16 / 20 Mtrs Height For Repairing Of Mh Light Fitting Of Any Size / Type And Reinstalling The Fitting / Cage Back To Its Position After Carrying Out Repairs All As Directed By Eic ( Cost Of Choke , Bulb , Igniter Will Be Measure Seprately ) , S&F In Repair Mh Lamp Only Single Ended Clear Tubular To Be Fixed In Mh / High Mast Light Fitting All As Directed By Eic . Make :- Havells / Philips / Cg / Wipro / Halonex / Bajaj , ( A ) 400 Watt , ( B ) 250 Watt , ( C ) 150 Watt , S&F In Repair For Open Constructed Copper Ballast For Mh Lamp 400 Watt Suitable For Hpsv / Mh / High Mast Fittings All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 250 Watts ( In Repairs ) , 240V All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 150 Watts ( In Repairs ) , 240V All As Specified And Directed . , S&F In Repair Ignitor ( Super Imposed Pluse Ignitor ) Suitable 70 To 400 W For Mh Lamp All As Specified And Directed . , Supply In Repairs Lamp Holder For Lamp Base E-27 Suitable For 70 / / 150 / 250 Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 10 Mfd , 250 V For 70 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 20 Mfd , 250 V For 150 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 33 Mfd , 250V For 250 Watt Hpsv / Mh Luminaries . , Excavation In Trenches Not Exceeding 1 . 5M Wide And Not Exceeding 1 . 5 M In Depth For Laying Of Caste And Getting Out In Hard / Dense Soil Disintegrated Rock . , Returning , Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 25 Cm In Soft / Hard Dense Soil , Removing Excavated Material Not Exc 50 Mtr And Depositing Where Directed At Level Not Exc 1 . 5 M Above The Starting Point Complete All As Specified And Directed , M&L For Clean , Dry , Unwashed Sand Filled In Trenches For Cushioning To Cable Complete All As Specified And As Directed At Site . Note:- The Depth Of Cushion After Punning Shall Be Measured . , Supply And Laying Burnt Brick Sub Class B Modular Size , For Cable Protection Laid Length Wise Perpendicular To The Axis Of Cable Complete All As Specified And Directed . , Taking Out Old Unserviceable Lt Under Ground Cable Of Any Size And Rating . , Supply And Laying In Repair Pvc Insulated Armoured Heavy Duty Electric Under Ground Cable Aluminum Conductor 1100 Volts Grade In Trenches / On Pole Through Sleeves Etc . Of 10 Sqmm 4 Core Complete All As Specified And Directed , M&L Cutting Pcc / Floor / Road And Taking Out Cable And Making Good , Including Material As Per Existing After Laying Of Pipe For Cable Protection All As Specified And Directed Size Of Trench Not More Than 0 . 30 X 0 . 30 Cm . , S&F In Replacement Of Gi Pipe Medium Grade On Road / Pole / Wall / Floor For Cable Protection With Fixing Arrangement Size 50Mm Dia . , M&L For Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate For Coping Around Poles , Including Necessary Form Work Finishing Even And Smooth Without Using Extra Cement , All As Specified And Directed . , M&L For Scratching Out Old Bubbled Paint , Finishing The Surface With One Coat Of Primer ( Red Oxide ) & Two Coats Of Aluminium Paint Of 1St Quality To Street Light Steel Tubuler Poles Of Any Height 7 / 9 Mtr , Any Type ( Double Swan , Single Swan ) All As Per Site Including Two Strips Of 30 Cm Wide To Be Painted Red Synthetic Enamele Above Embedded Level , Including Pole Number Writting With White Colour Enamel Paint On Black Colour Circular Base ) With Two Coat Of Lime Wash On Pole Coping All As Directed By Engr-In-Charge . , Supply & Fixing Factory Made Ip-65 ( Dust And Power Jet Proof According To Iec 60529 ) Opaque Street Light Junction Box Of Size 200 Mm X 160 Mmx98 Mm Made Of High Quality Polycarbonate ( Shock Proof , Rust Free , Corrosion Free Acid And Chemical Resistant , Fire Retardant Having High Impact ( Ik 08 ) Totally Insulated Made Of Halogen And Silica Free Recyclable Material , Uv Resistant Having High Grade Gasket Made Of Polyurethane With Copper Terminal , Mcb Sp 6 Amps Rating 10 Ka With Locking Arrangement And 2 Nos M40 Size Cable Gland And One M32 Size Gland Suitable Up To 16 Sqmm Cable Etc Complete All As Specified And Directed . Make: Hensel Cat No K-9255 Or Equivalent In Sintex . , M & L For Repair Of Solar Lights Likes Battery Boxes , Frame Etc . Including Replacing Of Following Accessories Complete All As Specified And Directed , Cfl 9 Watt ( Pin Type ) , Cfl 11 Watt ( Pin Type ) , Charge Controllar , Pcb , Distil Water For Battery , Battery 12 V 100 Ah Complete , Supplying And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor , Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed Wire , One Twin Core Cable Flat 6 Sqmm Complete All As Specified And Directed , S&F In Repair Of Automatic Street Light Switch Three Phase With Nature Switch-03 ( Dual Output ) As The Controlling Unit For Automatic Switching Of Street Lights Based On Lux Level Of Natural Light . The Sensor ( Nature Switch ) Along With Suitable Power Contractor , Mcb And Support Terminals Should Be Enclosed In Pole / Wall Mountable Enclosure Made Of Rust Proof , Electric Shock Proof , Termite Proof And Fr Grade Special Moulding Compound ( Sintex Make Smc Junction Box ) Confirming To Ip54 . The Contractor , Mcb And Circuit Wiring Should Suitable Enough To Take Load 5 Kw Equally Distributed Over 3 Phase ( 4 Kw / Phase ) . The Contractor Rating 25 Amps ( 4-Pole ) And Mcb ( Single Pole ) Rating : 20-25 Amps ( Sp-03 Nos ) , Complete All As Specified And Directed . , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 72 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 60 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 150 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-Jul-2020 | Corrigendum No 1 | BOQ | 20-Jul-2020 |
| 2 | 20-Jul-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-Jul-2020 |
| 3 | 27-Jul-2020 | Corrigendum No 3 | Date | 07-Aug-2020 |
BOQ
| Name of Work: REPAIR / MAINT OF STREET LIGHT, HIGH MAST LIGHT AND SOLAR LIGHT AT DRONACHAL BHOPAL | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Taking down and dismantling of street light fittings of any type size and model (FTL,ES, HPSV,MVL,MH, floodlight Fittings, solar light,), removing of unserviceable spares / accessories for repair/replacement of the same including refixing of street light fittings of any size , type and model on GI tubing bracket to existing pole of any type and any size(like single/double swan neck,straight,PCC/Steel tubular poles of 9/11 mts height) and testing complete all as directed. Note : (spare/parts required for repairing of fitting will be issued/paid under respective items of this schedule) | 70 | Each Job | |
| 2 | 2 | Taking down,dismantling and necessary repairing of LED street light fittings to make functional by replacing unserviceable part such as PCB, Lens, holder, insulation pad,heatsink, wire connecting terminal etc as existing including refixing of LED street light fittings of any size , type and model on GI tubing bracket to existing pole of any type and any size(like single/double swan neck,straight,PCC/Steel tubular poles of 9/11 mts height) including supply and fixing of PVC sheathed aluminium conductor mutistranded cable of 2 single core of 2.5 sqmm of min length 8 metre from fitting to electric supply source and testing complete all as directed. | 40 | Each Job | |
| 3 | 3 | M&L for taking down MH light fittings mounting on cage from High mast pole of 12.5/16/20 mtrs height for repairing of MH light fitting of any size/type and reinstalling the fitting/cage back to its position after carrying out repairs all as directed by EIC (Cost of choke, bulb,igniter will be measure seprately) | 15 | Each Job | |
| 4 | 4 | S&F in repair MH Lamp only single ended clear tubular to be fixed in MH/High Mast light fitting all as directed by EIC.Make :- Havells/Philips/CG/Wipro/Halonex/Bajaj | |||
| 5 | 4.1 | (a) 400 Watt | 10 | Each | |
| 6 | 4.2 | (b) 250 Watt | 10 | Each | |
| 7 | 4.3 | (c) 150 Watt | 50 | Each | |
| 8 | 5 | S&F in repair for open constructed copper Ballast for MH lamp 400 watt suitable for HPSV/MH/High Mast fittings all as specified and directed. | 10 | Each | |
| 9 | 6 | Supply and fixing in repair copper wound open constructed ballast suitable for HPSV/MH light fitting 250 watts (in repairs) ,240V all as specified and directed.\n | 10 | Each | |
| 10 | 7 | Supply and fixing in repair copper wound open constructed ballast suitable for HPSV/MH light fitting 150 watts (in repairs) ,240V all as specified and directed. \n | 50 | Each | |
| 11 | 8 | S&F in repair Ignitor (super imposed pluse ignitor) suitable 70 to 400 W for MH lamp all as specified and directed.\n | 50 | Each | |
| 12 | 9 | Supply in repairs Lamp Holder for lamp base E-27 suitable for 70//150/250 HPSV /MH luminaries. | 10 | Each | |
| 13 | 10 | Supply in repairs Capacitor 10 MFD, 250 V for 70 watt HPSV/MH luminaries. | 25 | Each | |
| 14 | 11 | Supply in repairs Capacitor 20 MFD, 250 V for 150 watt HPSV/MH luminaries. | 25 | Each | |
| 15 | 12 | Supply in repairs Capacitor 33 MFD, 250V for 250 watt HPSV/MH luminaries. | 20 | Each | |
| 16 | 13 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of caste and getting out in Hard / dense soil disintegrated rock. | 50 | Cum | |
| 17 | 14 | Returning , filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft/ hard dense soil | 30 | Cum | |
| 18 | 15 | Removing excavated material not exc 50 mtr and depositing where directed at level not exc 1.5 m above the starting point complete all as specified and directed | 20 | Cum | |
| 19 | 16 | M&L for clean, dry, unwashed sand filled in trenches for cushioning to cable complete all as specified and as directed at site. \nNOTE:- The depth of cushion after punning shall be measured. | 11 | Cum | |
| 20 | 17 | Supply and laying burnt brick sub class 'B' modular size, for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed. | 1740 | Each | |
| 21 | 18 | Taking out old unserviceable LT under ground cable of any size and rating. | 300 | RM | |
| 22 | 19 | Supply and Laying in repair PVC insulated armoured heavy duty electric under ground cable aluminum conductor 1100 volts grade in trenches/on pole through sleeves etc. of 10 Sqmm 4 Core complete all as specified and directed | 300 | RM | |
| 23 | 20 | M&L cutting PCC/floor/road and taking out cable and making good, including material as per existing after laying of pipe for cable protection all as specified and directed size of trench not more than 0.30 x 0.30 cm. | 12 | RM | |
| 24 | 21 | S&F in replacement of GI Pipe medium grade on road/pole/wall/floor for cable protection with fixing arrangement size 50mm dia. | 12 | RM | |
| 25 | 22 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. | 2 | Cum | |
| 26 | 23 | M&L for scratching out old bubbled paint, finishing the surface with one coat of primer (red oxide) & two coats of aluminium paint of 1st quality to street light steel tubuler poles of any height 7/9 mtr , any type (double swan, single swan) all as per site including two strips of 30 cm wide to be painted red synthetic enamele above embedded level, including pole number writting with white colour enamel paint on black colour circular base) with two coat of lime wash on pole coping all as directed by Engr-in-charge. | 170 | Each | |
| 27 | 24 | Supply & fixing factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 200 mm x 160 mmx98 mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated made of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to 16 Sqmm cable etc complete all as specified and directed.Make: HENSEL Cat No K-9255 or equivalent in Sintex. | 40 | Each | |
| 28 | 25 | M & L for repair of solar lights likes battery boxes, frame etc. including replacing of following accessories complete all as specified and directed | |||
| 29 | 25.1 | CFL 9 watt (pin type) | 5 | Each | |
| 30 | 25.2 | CFL 11 watt (pin type) | 5 | Each | |
| 31 | 25.3 | Charge controllar | 5 | Each | |
| 32 | 25.4 | PCB | 2 | Each | |
| 33 | 25.5 | Distil water for battery | 15 | Ltr | |
| 34 | 25.6 | Battery 12 V 100 AH complete | 3 | Each | |
| 35 | 26 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable flat 6 Sqmm complete all as specified and directed | 500 | RM | |
| 36 | 27 | S&F in repair of Automatic Street Light Switch Three phase with Nature Switch-03 (Dual Output) as the controlling unit for automatic switching of street lights based on LUX level of Natural light. The Sensor (Nature switch) along with suitable power contractor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust proof, Electric Shock proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) confirming to IP54. The contractor, MCB and circuit Wiring should suitable enough to take load 5 KW equally distributed over 3 phase (4 KW/Phase). The contractor rating 25 Amps (4-pole) and MCB(single pole) rating : 20-25 Amps(SP-03 Nos), complete all as specified and directed.\n | 6 | Each | |
| 37 | 28 | Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 72 W LED street light fitting including testing complete | 10 | Each | |
| 38 | 29 | Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 60 W LED street light fitting including testing complete | 11 | Each | |
| 39 | 30 | Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 150 W LED street light fitting including testing complete | 15 | Each | |
| 40 | 31 | Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 35 W LED street light fitting including testing complete | 20 | Each | |
| 41 | 32 | Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 25/20 W LED street light fitting including testing complete | 15 | Each | |
| 42 | 33 | Taking down high mast MH light fitting of 18 Mtr hight and repair to existing motor with replacement steel rope etc and refixing the same including electrical connection and testing complete all as directed by Engr-in-charge. Steel rope will be measured sepertely | 2 | Each Job | |
| 43 | 34 | Supply and replacement of High mast panel front/back door with existing thickness MS sheet not less than 1.5 mm powder coating paint including locking arrangement , Panel internal wiring and one coat existing paint complete all as per directed by Engr-in-charge | 6 | Each Job | |
| 44 | 35 | Fixing only 40 W LED street light complete all as specified and directed \nNote:- LED light will be issued under schedule 'B' free for fixing only. | 110 | Each | |
| 45 | 36 | Fixing only 100 W LED street light complete all as specified and directed \nNote:- LED light will be issued under schedule 'B' free for fixing only. | 40 | Each | |
| 46 | 37 | Fixing only 60 W LED street light complete all as specified and directed \nNote:- LED light will be issued under schedule 'B' free for fixing only. | 65 | Each | |
| 47 | 38 | S&F LED Street light fitting 1x 150 W energy saving and environmental friendly long life LED street light made up of Aluminium die-cast housing luminaire with unique lens system for enhanced uniform illumination and toughened glass with silicon gasket for IP66 protection. | 10 | Each | |
| 48 | 39 | S&F LED Street light fitting 1x 60 W energy saving and environmental friendly long life LED street light made up of Aluminium die-cast housing luminaire with unique lens system for enhanced uniform illumination and toughened glass with silicon gasket for IP66 protection. | 20 | Each | |
| 49 | 40 | S and F Post top 20 W LED light pure polyster UV resistant powder coated die cast aluminium housing with PMMA clear diffuser for uniform illumination. | 6 | Each | |
| 50 | 41 | S&F outdoor panel board suitable size for incoming MCCB four pole 63 Amps 415 Volt and outgoing MCB DP 32 Amps -03 Nos including ,internal wiring with copper wire and fixed on PCC foundation complete all as specified and directed.. | 5 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender