Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal

Issued by Statutory Bodies & Commissions/Committees · GE Dronachal, Madhya Pradesh
Tender Value
10 Lakhs
Estimated cost
Bid Submission
07 Aug 2020
0 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE Dronachal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal , Taking Down And Dismantling Of Street Light Fittings Of Any Type Size And Model ( Ftl , Es , Hpsv , Mvl , Mh , Floodlight Fittings , Solar Light , ) , Removing Of Unserviceable Spares / Accessories For Repair / Replacement Of The Same Including Refixing Of Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) And Testing Complete All As Directed . Note : ( Spare / Parts Required For Repairing Of Fitting Will Be Issued / Paid Under Respective Items Of This Schedule ) , Taking Down , Dismantling And Necessary Repairing Of Led Street Light Fittings To Make Functional By Replacing Unserviceable Part Such As Pcb , Lens , Holder , Insulation Pad , Heatsink , Wire Connecting Terminal Etc As Existing Including Refixing Of Led Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) Including Supply And Fixing Of Pvc Sheathed Aluminium Conductor Mutistranded Cable Of 2 Single Core Of 2 . 5 Sqmm Of Min Length 8 Metre From Fitting To Electric Supply Source And Testing Complete All As Directed . , M&L For Taking Down Mh Light Fittings Mounting On Cage From High Mast Pole Of 12 . 5 / 16 / 20 Mtrs Height For Repairing Of Mh Light Fitting Of Any Size / Type And Reinstalling The Fitting / Cage Back To Its Position After Carrying Out Repairs All As Directed By Eic ( Cost Of Choke , Bulb , Igniter Will Be Measure Seprately ) , S&F In Repair Mh Lamp Only Single Ended Clear Tubular To Be Fixed In Mh / High Mast Light Fitting All As Directed By Eic . Make :- Havells / Philips / Cg / Wipro / Halonex / Bajaj , ( A ) 400 Watt , ( B ) 250 Watt , ( C ) 150 Watt , S&F In Repair For Open Constructed Copper Ballast For Mh Lamp 400 Watt Suitable For Hpsv / Mh / High Mast Fittings All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 250 Watts ( In Repairs ) , 240V All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 150 Watts ( In Repairs ) , 240V All As Specified And Directed . , S&F In Repair Ignitor ( Super Imposed Pluse Ignitor ) Suitable 70 To 400 W For Mh Lamp All As Specified And Directed . , Supply In Repairs Lamp Holder For Lamp Base E-27 Suitable For 70 / / 150 / 250 Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 10 Mfd , 250 V For 70 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 20 Mfd , 250 V For 150 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 33 Mfd , 250V For 250 Watt Hpsv / Mh Luminaries . , Excavation In Trenches Not Exceeding 1 . 5M Wide And Not Exceeding 1 . 5 M In Depth For Laying Of Caste And Getting Out In Hard / Dense Soil Disintegrated Rock . , Returning , Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 25 Cm In Soft / Hard Dense Soil , Removing Excavated Material Not Exc 50 Mtr And Depositing Where Directed At Level Not Exc 1 . 5 M Above The Starting Point Complete All As Specified And Directed , M&L For Clean , Dry , Unwashed Sand Filled In Trenches For Cushioning To Cable Complete All As Specified And As Directed At Site . Note:- The Depth Of Cushion After Punning Shall Be Measured . , Supply And Laying Burnt Brick Sub Class B Modular Size , For Cable Protection Laid Length Wise Perpendicular To The Axis Of Cable Complete All As Specified And Directed . , Taking Out Old Unserviceable Lt Under Ground Cable Of Any Size And Rating . , Supply And Laying In Repair Pvc Insulated Armoured Heavy Duty Electric Under Ground Cable Aluminum Conductor 1100 Volts Grade In Trenches / On Pole Through Sleeves Etc . Of 10 Sqmm 4 Core Complete All As Specified And Directed , M&L Cutting Pcc / Floor / Road And Taking Out Cable And Making Good , Including Material As Per Existing After Laying Of Pipe For Cable Protection All As Specified And Directed Size Of Trench Not More Than 0 . 30 X 0 . 30 Cm . , S&F In Replacement Of Gi Pipe Medium Grade On Road / Pole / Wall / Floor For Cable Protection With Fixing Arrangement Size 50Mm Dia . , M&L For Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate For Coping Around Poles , Including Necessary Form Work Finishing Even And Smooth Without Using Extra Cement , All As Specified And Directed . , M&L For Scratching Out Old Bubbled Paint , Finishing The Surface With One Coat Of Primer ( Red Oxide ) & Two Coats Of Aluminium Paint Of 1St Quality To Street Light Steel Tubuler Poles Of Any Height 7 / 9 Mtr , Any Type ( Double Swan , Single Swan ) All As Per Site Including Two Strips Of 30 Cm Wide To Be Painted Red Synthetic Enamele Above Embedded Level , Including Pole Number Writting With White Colour Enamel Paint On Black Colour Circular Base ) With Two Coat Of Lime Wash On Pole Coping All As Directed By Engr-In-Charge . , Supply & Fixing Factory Made Ip-65 ( Dust And Power Jet Proof According To Iec 60529 ) Opaque Street Light Junction Box Of Size 200 Mm X 160 Mmx98 Mm Made Of High Quality Polycarbonate ( Shock Proof , Rust Free , Corrosion Free Acid And Chemical Resistant , Fire Retardant Having High Impact ( Ik 08 ) Totally Insulated Made Of Halogen And Silica Free Recyclable Material , Uv Resistant Having High Grade Gasket Made Of Polyurethane With Copper Terminal , Mcb Sp 6 Amps Rating 10 Ka With Locking Arrangement And 2 Nos M40 Size Cable Gland And One M32 Size Gland Suitable Up To 16 Sqmm Cable Etc Complete All As Specified And Directed . Make: Hensel Cat No K-9255 Or Equivalent In Sintex . , M & L For Repair Of Solar Lights Likes Battery Boxes , Frame Etc . Including Replacing Of Following Accessories Complete All As Specified And Directed , Cfl 9 Watt ( Pin Type ) , Cfl 11 Watt ( Pin Type ) , Charge Controllar , Pcb , Distil Water For Battery , Battery 12 V 100 Ah Complete , Supplying And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor , Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed Wire , One Twin Core Cable Flat 6 Sqmm Complete All As Specified And Directed , S&F In Repair Of Automatic Street Light Switch Three Phase With Nature Switch-03 ( Dual Output ) As The Controlling Unit For Automatic Switching Of Street Lights Based On Lux Level Of Natural Light . The Sensor ( Nature Switch ) Along With Suitable Power Contractor , Mcb And Support Terminals Should Be Enclosed In Pole / Wall Mountable Enclosure Made Of Rust Proof , Electric Shock Proof , Termite Proof And Fr Grade Special Moulding Compound ( Sintex Make Smc Junction Box ) Confirming To Ip54 . The Contractor , Mcb And Circuit Wiring Should Suitable Enough To Take Load 5 Kw Equally Distributed Over 3 Phase ( 4 Kw / Phase ) . The Contractor Rating 25 Amps ( 4-Pole ) And Mcb ( Single Pole ) Rating : 20-25 Amps ( Sp-03 Nos ) , Complete All As Specified And Directed . , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 72 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 60 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 150 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Jul-2020 Corrigendum No 1 BOQ 20-Jul-2020
2 20-Jul-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-Jul-2020
3 27-Jul-2020 Corrigendum No 3 Date 07-Aug-2020

BOQ

Name of Work: REPAIR / MAINT OF STREET LIGHT, HIGH MAST LIGHT AND SOLAR LIGHT AT DRONACHAL BHOPAL
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Taking down and dismantling of street light fittings of any type size and model (FTL,ES, HPSV,MVL,MH, floodlight Fittings, solar light,), removing of unserviceable spares / accessories for repair/replacement of the same including refixing of street light fittings of any size , type and model on GI tubing bracket to existing pole of any type and any size(like single/double swan neck,straight,PCC/Steel tubular poles of 9/11 mts height) and testing complete all as directed. Note : (spare/parts required for repairing of fitting will be issued/paid under respective items of this schedule)70Each Job
22Taking down,dismantling and necessary repairing of LED street light fittings to make functional by replacing unserviceable part such as PCB, Lens, holder, insulation pad,heatsink, wire connecting terminal etc as existing including refixing of LED street light fittings of any size , type and model on GI tubing bracket to existing pole of any type and any size(like single/double swan neck,straight,PCC/Steel tubular poles of 9/11 mts height) including supply and fixing of PVC sheathed aluminium conductor mutistranded cable of 2 single core of 2.5 sqmm of min length 8 metre from fitting to electric supply source and testing complete all as directed.40Each Job
33M&L for taking down MH light fittings mounting on cage from High mast pole of 12.5/16/20 mtrs height for repairing of MH light fitting of any size/type and reinstalling the fitting/cage back to its position after carrying out repairs all as directed by EIC (Cost of choke, bulb,igniter will be measure seprately)15Each Job
44S&F in repair MH Lamp only single ended clear tubular to be fixed in MH/High Mast light fitting all as directed by EIC.Make :- Havells/Philips/CG/Wipro/Halonex/Bajaj
54.1(a) 400 Watt10Each
64.2(b) 250 Watt10Each
74.3(c) 150 Watt50Each
85S&F in repair for open constructed copper Ballast for MH lamp 400 watt suitable for HPSV/MH/High Mast fittings all as specified and directed.10Each
96Supply and fixing in repair copper wound open constructed ballast suitable for HPSV/MH light fitting 250 watts (in repairs) ,240V all as specified and directed.\n10Each
107Supply and fixing in repair copper wound open constructed ballast suitable for HPSV/MH light fitting 150 watts (in repairs) ,240V all as specified and directed. \n50Each
118S&F in repair Ignitor (super imposed pluse ignitor) suitable 70 to 400 W for MH lamp all as specified and directed.\n50Each
129Supply in repairs Lamp Holder for lamp base E-27 suitable for 70//150/250 HPSV /MH luminaries.10Each
1310Supply in repairs Capacitor 10 MFD, 250 V for 70 watt HPSV/MH luminaries.25Each
1411Supply in repairs Capacitor 20 MFD, 250 V for 150 watt HPSV/MH luminaries.25Each
1512Supply in repairs Capacitor 33 MFD, 250V for 250 watt HPSV/MH luminaries.20Each
1613Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of caste and getting out in Hard / dense soil disintegrated rock.50Cum
1714Returning , filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft/ hard dense soil30Cum
1815Removing excavated material not exc 50 mtr and depositing where directed at level not exc 1.5 m above the starting point complete all as specified and directed20Cum
1916M&L for clean, dry, unwashed sand filled in trenches for cushioning to cable complete all as specified and as directed at site. \nNOTE:- The depth of cushion after punning shall be measured.11Cum
2017Supply and laying burnt brick sub class 'B' modular size, for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed.1740Each
2118Taking out old unserviceable LT under ground cable of any size and rating.300RM
2219Supply and Laying in repair PVC insulated armoured heavy duty electric under ground cable aluminum conductor 1100 volts grade in trenches/on pole through sleeves etc. of 10 Sqmm 4 Core complete all as specified and directed300RM
2320M&L cutting PCC/floor/road and taking out cable and making good, including material as per existing after laying of pipe for cable protection all as specified and directed size of trench not more than 0.30 x 0.30 cm.12RM
2421S&F in replacement of GI Pipe medium grade on road/pole/wall/floor for cable protection with fixing arrangement size 50mm dia.12RM
2522M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.2Cum
2623M&L for scratching out old bubbled paint, finishing the surface with one coat of primer (red oxide) & two coats of aluminium paint of 1st quality to street light steel tubuler poles of any height 7/9 mtr , any type (double swan, single swan) all as per site including two strips of 30 cm wide to be painted red synthetic enamele above embedded level, including pole number writting with white colour enamel paint on black colour circular base) with two coat of lime wash on pole coping all as directed by Engr-in-charge.170Each
2724Supply & fixing factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 200 mm x 160 mmx98 mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated made of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to 16 Sqmm cable etc complete all as specified and directed.Make: HENSEL Cat No K-9255 or equivalent in Sintex.40Each
2825M & L for repair of solar lights likes battery boxes, frame etc. including replacing of following accessories complete all as specified and directed
2925.1CFL 9 watt (pin type)5Each
3025.2CFL 11 watt (pin type)5Each
3125.3Charge controllar5Each
3225.4PCB2Each
3325.5Distil water for battery15Ltr
3425.6Battery 12 V 100 AH complete3Each
3526Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable flat 6 Sqmm complete all as specified and directed500RM
3627S&F in repair of Automatic Street Light Switch Three phase with Nature Switch-03 (Dual Output) as the controlling unit for automatic switching of street lights based on LUX level of Natural light. The Sensor (Nature switch) along with suitable power contractor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust proof, Electric Shock proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) confirming to IP54. The contractor, MCB and circuit Wiring should suitable enough to take load 5 KW equally distributed over 3 phase (4 KW/Phase). The contractor rating 25 Amps (4-pole) and MCB(single pole) rating : 20-25 Amps(SP-03 Nos), complete all as specified and directed.\n6Each
3728Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 72 W LED street light fitting including testing complete10Each
3829Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 60 W LED street light fitting including testing complete11Each
3930Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 150 W LED street light fitting including testing complete15Each
4031Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 35 W LED street light fitting including testing complete20Each
4132Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 25/20 W LED street light fitting including testing complete15Each
4233Taking down high mast MH light fitting of 18 Mtr hight and repair to existing motor with replacement steel rope etc and refixing the same including electrical connection and testing complete all as directed by Engr-in-charge. Steel rope will be measured sepertely2Each Job
4334Supply and replacement of High mast panel front/back door with existing thickness MS sheet not less than 1.5 mm powder coating paint including locking arrangement , Panel internal wiring and one coat existing paint complete all as per directed by Engr-in-charge6Each Job
4435Fixing only 40 W LED street light complete all as specified and directed \nNote:- LED light will be issued under schedule 'B' free for fixing only.110Each
4536Fixing only 100 W LED street light complete all as specified and directed \nNote:- LED light will be issued under schedule 'B' free for fixing only.40Each
4637Fixing only 60 W LED street light complete all as specified and directed \nNote:- LED light will be issued under schedule 'B' free for fixing only.65Each
4738S&F LED Street light fitting 1x 150 W energy saving and environmental friendly long life LED street light made up of Aluminium die-cast housing luminaire with unique lens system for enhanced uniform illumination and toughened glass with silicon gasket for IP66 protection.10Each
4839S&F LED Street light fitting 1x 60 W energy saving and environmental friendly long life LED street light made up of Aluminium die-cast housing luminaire with unique lens system for enhanced uniform illumination and toughened glass with silicon gasket for IP66 protection.20Each
4940S and F Post top 20 W LED light pure polyster UV resistant powder coated die cast aluminium housing with PMMA clear diffuser for uniform illumination.6Each
5041S&F outdoor panel board suitable size for incoming MCCB four pole 63 Amps 415 Volt and outgoing MCB DP 32 Amps -03 Nos including ,internal wiring with copper wire and fixed on PCC foundation complete all as specified and directed..5Each

AI Tender Summary

OUR REF NO 24741959
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10 Lakhs
LAST DATE 07-08-2020
Authority
Authority Name Military Engineer Services
Work Description Repair / Maintenance Of Street Light , High Mast Light And Solar Light At Dronachal Bhopal , Taking Down And Dismantling Of Street Light Fittings Of Any Type Size And Model ( Ftl , Es , Hpsv , Mvl , Mh , Floodlight Fittings , Solar Light , ) , Removing Of Unserviceable Spares / Accessories For Repair / Replacement Of The Same Including Refixing Of Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) And Testing Complete All As Directed . Note : ( Spare / Parts Required For Repairing Of Fitting Will Be Issued / Paid Under Respective Items Of This Schedule ) , Taking Down , Dismantling And Necessary Repairing Of Led Street Light Fittings To Make Functional By Replacing Unserviceable Part Such As Pcb , Lens , Holder , Insulation Pad , Heatsink , Wire Connecting Terminal Etc As Existing Including Refixing Of Led Street Light Fittings Of Any Size , Type And Model On Gi Tubing Bracket To Existing Pole Of Any Type And Any Size ( Like Single / Double Swan Neck , Straight , Pcc / Steel Tubular Poles Of 9 / 11 Mts Height ) Including Supply And Fixing Of Pvc Sheathed Aluminium Conductor Mutistranded Cable Of 2 Single Core Of 2 . 5 Sqmm Of Min Length 8 Metre From Fitting To Electric Supply Source And Testing Complete All As Directed . , M&L For Taking Down Mh Light Fittings Mounting On Cage From High Mast Pole Of 12 . 5 / 16 / 20 Mtrs Height For Repairing Of Mh Light Fitting Of Any Size / Type And Reinstalling The Fitting / Cage Back To Its Position After Carrying Out Repairs All As Directed By Eic ( Cost Of Choke , Bulb , Igniter Will Be Measure Seprately ) , S&F In Repair Mh Lamp Only Single Ended Clear Tubular To Be Fixed In Mh / High Mast Light Fitting All As Directed By Eic . Make :- Havells / Philips / Cg / Wipro / Halonex / Bajaj , ( A ) 400 Watt , ( B ) 250 Watt , ( C ) 150 Watt , S&F In Repair For Open Constructed Copper Ballast For Mh Lamp 400 Watt Suitable For Hpsv / Mh / High Mast Fittings All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 250 Watts ( In Repairs ) , 240V All As Specified And Directed . , Supply And Fixing In Repair Copper Wound Open Constructed Ballast Suitable For Hpsv / Mh Light Fitting 150 Watts ( In Repairs ) , 240V All As Specified And Directed . , S&F In Repair Ignitor ( Super Imposed Pluse Ignitor ) Suitable 70 To 400 W For Mh Lamp All As Specified And Directed . , Supply In Repairs Lamp Holder For Lamp Base E-27 Suitable For 70 / / 150 / 250 Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 10 Mfd , 250 V For 70 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 20 Mfd , 250 V For 150 Watt Hpsv / Mh Luminaries . , Supply In Repairs Capacitor 33 Mfd , 250V For 250 Watt Hpsv / Mh Luminaries . , Excavation In Trenches Not Exceeding 1 . 5M Wide And Not Exceeding 1 . 5 M In Depth For Laying Of Caste And Getting Out In Hard / Dense Soil Disintegrated Rock . , Returning , Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc 25 Cm In Soft / Hard Dense Soil , Removing Excavated Material Not Exc 50 Mtr And Depositing Where Directed At Level Not Exc 1 . 5 M Above The Starting Point Complete All As Specified And Directed , M&L For Clean , Dry , Unwashed Sand Filled In Trenches For Cushioning To Cable Complete All As Specified And As Directed At Site . Note:- The Depth Of Cushion After Punning Shall Be Measured . , Supply And Laying Burnt Brick Sub Class B Modular Size , For Cable Protection Laid Length Wise Perpendicular To The Axis Of Cable Complete All As Specified And Directed . , Taking Out Old Unserviceable Lt Under Ground Cable Of Any Size And Rating . , Supply And Laying In Repair Pvc Insulated Armoured Heavy Duty Electric Under Ground Cable Aluminum Conductor 1100 Volts Grade In Trenches / On Pole Through Sleeves Etc . Of 10 Sqmm 4 Core Complete All As Specified And Directed , M&L Cutting Pcc / Floor / Road And Taking Out Cable And Making Good , Including Material As Per Existing After Laying Of Pipe For Cable Protection All As Specified And Directed Size Of Trench Not More Than 0 . 30 X 0 . 30 Cm . , S&F In Replacement Of Gi Pipe Medium Grade On Road / Pole / Wall / Floor For Cable Protection With Fixing Arrangement Size 50Mm Dia . , M&L For Plain Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate For Coping Around Poles , Including Necessary Form Work Finishing Even And Smooth Without Using Extra Cement , All As Specified And Directed . , M&L For Scratching Out Old Bubbled Paint , Finishing The Surface With One Coat Of Primer ( Red Oxide ) & Two Coats Of Aluminium Paint Of 1St Quality To Street Light Steel Tubuler Poles Of Any Height 7 / 9 Mtr , Any Type ( Double Swan , Single Swan ) All As Per Site Including Two Strips Of 30 Cm Wide To Be Painted Red Synthetic Enamele Above Embedded Level , Including Pole Number Writting With White Colour Enamel Paint On Black Colour Circular Base ) With Two Coat Of Lime Wash On Pole Coping All As Directed By Engr-In-Charge . , Supply & Fixing Factory Made Ip-65 ( Dust And Power Jet Proof According To Iec 60529 ) Opaque Street Light Junction Box Of Size 200 Mm X 160 Mmx98 Mm Made Of High Quality Polycarbonate ( Shock Proof , Rust Free , Corrosion Free Acid And Chemical Resistant , Fire Retardant Having High Impact ( Ik 08 ) Totally Insulated Made Of Halogen And Silica Free Recyclable Material , Uv Resistant Having High Grade Gasket Made Of Polyurethane With Copper Terminal , Mcb Sp 6 Amps Rating 10 Ka With Locking Arrangement And 2 Nos M40 Size Cable Gland And One M32 Size Gland Suitable Up To 16 Sqmm Cable Etc Complete All As Specified And Directed . Make: Hensel Cat No K-9255 Or Equivalent In Sintex . , M & L For Repair Of Solar Lights Likes Battery Boxes , Frame Etc . Including Replacing Of Following Accessories Complete All As Specified And Directed , Cfl 9 Watt ( Pin Type ) , Cfl 11 Watt ( Pin Type ) , Charge Controllar , Pcb , Distil Water For Battery , Battery 12 V 100 Ah Complete , Supplying And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor , Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed Wire , One Twin Core Cable Flat 6 Sqmm Complete All As Specified And Directed , S&F In Repair Of Automatic Street Light Switch Three Phase With Nature Switch-03 ( Dual Output ) As The Controlling Unit For Automatic Switching Of Street Lights Based On Lux Level Of Natural Light . The Sensor ( Nature Switch ) Along With Suitable Power Contractor , Mcb And Support Terminals Should Be Enclosed In Pole / Wall Mountable Enclosure Made Of Rust Proof , Electric Shock Proof , Termite Proof And Fr Grade Special Moulding Compound ( Sintex Make Smc Junction Box ) Confirming To Ip54 . The Contractor , Mcb And Circuit Wiring Should Suitable Enough To Take Load 5 Kw Equally Distributed Over 3 Phase ( 4 Kw / Phase ) . The Contractor Rating 25 Amps ( 4-Pole ) And Mcb ( Single Pole ) Rating : 20-25 Amps ( Sp-03 Nos ) , Complete All As Specified And Directed . , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 72 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 60 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix Led Driver 240 Volts 50 Hz Suitable For 150 W Led Street Light Fitting Including Testing Complete , Taking Down Defective Led Driver And Supply And Fix
Basic Detail
Tender No 8544/E8
Bidding Type Tender
Location
City GE Dronachal
State Madhya Pradesh
Key Dates
Publish Date 27 Jul 2020
Submission Date 07 Aug 2020
Open Date 14 Aug 2020
Finance
Tender Value 10 Lakhs
Tender Fee 500
EMD 20000
Exemption Not Available
Document List
BOQ_398240.xls
C752FCBB-C0F7-4C23-B659-AD37372B75DF.html
Tendernotice_1.pdf
Generalpages8544.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 27, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2020
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 27, 2020
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 07, 2020
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 07, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 14, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_398240.xls

html

C752FCBB-C0F7-4C23-B659-AD37372B75DF.html

pdf

Tendernotice_1.pdf

pdf

Generalpages8544.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders