Annual Rate Contract For “Handling Of Material In Divisional Store Of Sub Transmission Division Kathua, For The Year 2020-21 Or Till The Next Contract-2 Installation, testing and Commissioning of Electronic Relay Overcurrent/Earth Fault by way of replacement of damaged/burnt of the same ratio,type , make and class already installed in the 11 KV panel conforming to IEC -61850 standard and operating voltage 30-36 V DC 3 Fabrication, testing and Commissioning of PVC insulated Copper Bus Bar (50 mm x 12 mm) Including nuts and Bolts. 4 Replacement of Damaged 11 KV spout Bushing for 11KV VCB Panels of following Make 5 Vijai 6 Stelmec 7 Easun Reyrolle 8 Alstom 9 Sudhir 10 Electric Field 11 Crompton 12 Siemens 13 Replacement of 11 KV Vacuum interupters 14 Vijai 15 Stelmec 16 Easun Reyrolle 17 Alstom 18 Sudhir 19 Electric Field 20 Crompton 21 Siemens 22 Replacement of 11KV vacuum Interrupters Housing Assembly 23 Vijai 24 Stelmec 25 Easun Reyrolle 26 Alstom 27 Sudhir 28 Electric Field 29 Crompton 30 Siemens 31 Installation, testing and Commissioning of Electronic Differential Relay of different Make in 66KV C&R Panel 32 Replacement of Tripping Coils 36 V DC 33 Vijai 34 Stelmec 35 Easun Reyrolle 36 Alstom 37 Sudhir 38 Electric Field 39 Crompton 40 Siemens 41 Replacement of Closing Coils 36 KV DC 42 Vijai 43 Stelmec 44 Easun Reyrolle 45 Alstom 46 Sudhir 47 Electric Field 48 Crompton 49 Siemens 50 Installation, testing and Commissioning of 11 KV CTs Set I/D type cast Resin by way of replacement of damaged one of same ratio amd make already installed in panel for various 11 KV Panel makes Vijai, Siemens, , Alstom, Sudhir, Stelmec, Easun Reyrolle, Crompton,Electric Field conforming to IEC 60044-1-2000 standard 51 750/375/5 -5A 52 600/300/150/5-5 A 53 400/200/5-5 A 54 300/150/5 -5A 55 100/50/5-5 A 56 Installation, testing and commissioning of 11 KV CTs I/D type of various types 57 Installation, testing and Commissioning of 11 KV PTs Set I/D (11KV/110 V) type cast Resin by way of replacement of damaged one of same ratio and make already installed in panel for various 11 KV Panel makes Vijai, Siemens, , Alstom, Sudhir, Stelmec, Easun Reyrolle, Crompton,Electric Field conforming to IEC 60044-1-2000 standard 58 66KV CT 59 Installation, testing and Commissioning of 66 KV CTs Set outdoor type conformong to IEC- 185 and IS 2705(Part 1 to 4) by way of replacement of damaged one of different Ratios 60 250/125/5-5 A 61 125/62.5/5-5 A 62 100/50/5-5A 63 100/50/1-1A 64 Installation, testing and Commissioning of various 66 KV CT 65 Checking of oil level, measurment of IR value, filling of oil (if required) and tightning of jumpers etc. 66 66 KV PT 67 Installation/Testing and Commissioning of 66 KV PT , 20 VA, 3P- 66KV/110Vv3 outdoor type conformong to IS 3156(Part 1 to 3) by way of replacement of damaged one 68 Installation/Testing and Commissioning of 66 KV PT , 20 VA, 3P- 66KV/110Vv3 outdoor type conformong to IS 3156 (Part 1 to 3) by way of replacement of damaged one 69 Checking of oil level, measurment of IR value, filling of oil (if required) and tightning of jumpers. 70 Repairing/Repalcement of 11 KV VCBs. 71 Tripping Mechanism 72 Modification of mechanism 73 Re-Setting Links 74 Replacement of operating shaft 75 Shower Contact 76 Isolating Sockets 77 Closing Mechanism (Replacement) 78 High Tension Spring 79 Tripping Shaft 80 Rollers 81 Latch Assembly 82 Overhauling of 11 KV VCB 83 Deco Spray painting 84 Rectification, re alignment andSetting right of 11 KV VCB (siemens, Easun Reyrolle, Vijai,Crompton,Stelmec,Sudhir,Electric Field, alstom) 85 Installation, Testing and Commissioning of 11 KV Panels equipments/items. 86 Digital 2 OC & 1 EF Relay (MakeEasun/L&T,Ashida,schnieder,C&S,siemen,micom,ABB) 87 Voltmeter 11KV/110V 88 Ampere meter 89 Selector Switch- 16Amps 90 LED panel Indicators 91 Push Button 92 Master Tripping Relay 93 HRC fuse with Base -16 Amps 94 Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc 95 Connecting Ribs 96 Auxilary Switch 97 Auxilary Relay -30 A 98 TNC Switch 99 Trip Circuit Supervision Relay 100 Electronic Hooter/bell (Replacement) 101 Annunciator 102 Antipumping device 103 Installation, Testing and Commissioning of 66 KV C &R Panel equipments/items. 104 Repairing of 66 KV C&R Panel 105 Replacement of Bucholz, Winding Temperature, Oil Temperature, Tripping Relay 106 Replacement of Bucholz, Winding Temperature, Oil Temperature, Alarm Relay 107 Replacement of Master Tripping Relay 108 Replacement of Closing Trip Switch 109 Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc 110 Deco Spray painting 111 MW Meter (Replacement) 112 Energy Meter (Replacement) 113 Electronic Hooter (Replacement) 114 Ampere meter with Selector switch 115 voltmeter with selector switch 116 Close/ Trip Switch 117 HRC fuse with Base -1 Amps 118 HRC fuse with Base -6 Amps 119 HRC fuse with Base -16 Amps 120 LED panel Indicators 121 Push Button 122 Annunciator 123 O/C and E/F relay 124 Restricted E/F relay 125 Installation, testing and Commissioning of various 66 KV C& R Panel 126 Repairing of 66 KV SF6 Breaker 127 SF6 Gas filling 128 66 KV Porcelain Insulator (Replacement) 129 Operating Rods (Replacement) 130 Closing Coils with Housing (Replacement) 131 Tripping Coils wih Housing (Replacement) 132 Motor Charging 240AC 133 Contactor (Replacement) 134 Gasket 135 Operating Shaft 136 Mechanism Housing 137 Gear Assembly 138 Auxillary Switch 139 Rollers 140 Charging Rod/Wheels 141 Replacement of SF6 gas meter 142 Installation, testing and Commissioning of 66KV SF6 breaker 143 Rectification, re alignment and Setting right of 66 KV SF6 breaker (ABB, crompton greaves etc) 144 66/11 KV Power Tranformer 145 Topping of oil including 146 Replacement of 66KV Bushing 147 Replacement of 66KV Bushing Rods 148 Replacement of 11 KV Bushing 149 Replacement of 11 KV Bushing Rods 150 Supply, installation and fixing of Bi-Metallic Clamps of Bush Rod 151 Tap Changer Contact replacement 152 Tap Changer Contact Repairs 153 Gasket Set of Bushing replacement 154 Gasket Set of Tap Changer/Radiators replacement 155 Male contact (Replacement) 156 Female contact (Replacement) 157 Dehydration/Filteration of Power Transformer Oil 158 Buchloz Relay replacement 159 Winding Temperature Meter with Probe replacement 160 Repairing of leakage of radiators by way of gas welding 161 Supply and Replacement/Repairing of damaged cooling fans of radiators 162 Oil Temperature meter With Probe replacement 163 Replacement of Silica gel 164 Transformer neutral Earthing complete with cu Strip replacement. 165 Installation & commissioning of Power Transformer including assembly fixing of bushes, radiator ,fans(if any), wiring of instrument 166 1MVA upto and including 2.5 MVA 167 Above 2.5MVA upto upto and including 6.3 MVA 168 Above 6.3 MVA upto upto and including 10MVA 169 Above 10 MVA upto upto and including 20MVA 170 Above 20MVA 171 Retrofitted 11KV VCB:- 172 Modification of Tripping Mechanism with Complete Assembly retrofitted from to new Mechanism of same make duly Modified in Order to Have reliable tripping mechanism as well as smooth operational functionalities. 173 Retrofitted 66KV Sf6 Breaker:- 174 Modification of Tripping Mechanism with Complete Assembly retrofitted from to new Mechanism of same make duly Modified in Order to Have reliable tripping mechanism as well as smooth operational functionalities. 175 66KV isolator 176 Installation/Testing and Commissioning of 66 KV Isolator without Earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60168 standard 177 Installation/Testing and Commissioning of 66 KV Isolator with Earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60168 standard 178 Checking of moving/fixed contacts, cleaning ,greasing of contacts,cleaning of post insulator,auxillary switches contacts ,tightning of clamps 179 Repair of damaged 66 kvisolator including replacement of mouth, post insulator, damaged blades,isolator pipe etc including supply of neccesary material. 180 66 KV Lightning Arrestor 181 Installation/Testing and Commissioning of 66 KV LA including levelling,assembling ,fixing,alignment,testing and making all connections by way of replacement of damaged one conforming to IEC 60099-4 standard 182 Measurement of IR value, leakage current and tightning of droppers 183 Eathing Mat 184 Measurement of earth resistivity, checking of electrical continuity of equipment earthing, tightning of earthing connectors,removal of rust from bolted earth connections and retightning 185 Installation/Testing and Commissioning of 11 KV Panel 186 Installation, testing and commissioning of 2 x 10 mm Copper Bus Bar 187 Installation, testing and commissioning of 100A MCCB with enclosure box 188 Installation of Enclosure Box for Bus Bar 189 Battery bank and Battery Charger of 36 V 190 Installation, Testing and Commissioning of 36 V automatic battery charger with Float cum Boost Charger 191 Installation, Testing and Commissioning of DC system 36 V, maintenance free VRLA batteries 200 AH 2 V x 18 no. including its mounting arrangement, wiring and battery terminal holders of required equipment conforming to IEC- 60896 standard 192 Installation, Testing and Commissioning of DC system 36 V, maintenance free VRLA batteries 100 AH 2 V x 18 no. including its mounting arrangement, wiring and battery terminal holders of required equipment conforming to IEC- 60896 standard 193 Repair of Battery Charger of 36 V 194 Repair/replacement of Battery cell of 2V 100AH/2V 200AH. 195 11 KV Power cables 196 laying, Testing and Commissioning of 11 KV armoured XLPE power cable conforming to IS 7089(Part-II)-1895 by way of replacement and dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench making roll to safer sideoutside and carriage of same to store and laying in the power cable trench, peeling the cable , fixing the earth clamps and fitting the HS cable kit to both ends, fixing to panel and outgoing structure including testing and commissioning. 197 120mm²(3-core) 198 185mm²(3-core) 199 240mm²(3-core) 200 300mm²(3-core) 201 400mm²(3-core) 202 630mm²(single-core) 203 Supply and replacement of 11 kv Damaged Cable kits 204 Installation, testing and Commissioning of 11 KV , heat shrinkable cable kit Indoor type conforming to IS 13573/1993 with latest ammmentments if any by way of replacement and dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench peeling the cable and removing/cutting damaged cable kit, roving PVC insulation, cleaning of XLPE Insulation, crimping of thimbles, fitting the HS cable kit,laying the power cable in trench ,fixing with nuts and bolts,connecting the earth point of the cable with existing earthing system ,fixing to panel and outgoing structure.complete job testing and commissioning. 205 120mm²(3-core) 206 185mm²(3-core) 207 240mm²(3-core) 208 300mm²(3-core) 209 400mm²(3-core) 210 630mm²(single-core) 211 Installation, testing and Commissioning of 11 KV , heat shrinkable cable kit outdoor type conforming to IS 13573/1993 with latest ammmentments if any by way of replacement and dismantling of damaged cable from the outgoing structure, taking out from cable trench peeling the cable and removing/cutting damaged cable kit, roving PVC insulation, cleaning of XLPE Insulation, crimping of thimbles, fitting the HS cable kit,laying the power cable in trench ,fixing with nuts and bolts,connecting the earth point of the cable with existing earthing system ,fixing to outgoing structure.complete job testing and commissioning. 212 120mm²(3-core) 213 185mm²(3-core) 214 240mm²(3-core) 215 300mm²(3-core) 216 400mm²(3-core) 217 630mm²(single-core) 218 Providing , laying and Fixing of 2-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 219 Providing , laying and Fixing of 4-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 220 Providing laying and Fixing of 8-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 221 Providing,laying and Fixing of 12-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS conforming to IS 1554(part 1), IS 8130,IS 5831 222 Replacement of damaged 11 kv Post Insulator or providing additional post insulator 223 Replacement of 66KV busbar of single condductor with size upto 0.4 sq. inch including replacement of disc insulators, tigtning of clamp, jumpers droppers if required. 224 Replacement of damaged LED bulbs of control room building and switchyard lighting 225 11KV Auxillary Transformer 226 Topping of oil including 227 Replacement of HT/LT bushing 228 Replacement of HT/LT bush rods including supply of material 229 Replacement of HT/LT bushing gaskets 230 Repair of Auxillary Transformer 231 25KVA 232 63KVA 233 100KVA 234 Installation of Auxillary Transformer 235 25KVA 236 63KVA 237 100KVA 238 Replacement of LT cable 3½ core 120mm² for auxillary transformer 239 Dragging (upto avg. 50 mtr) and rotation if required of Power transformer 66/11 kv 240 1MVA upto and including 2.5 MVA 241 Above 2.5MVA upto upto and including 6.3 MVA 242 Above 6.3 MVA upto upto and including 10MVA 243 Above 10 MVA upto upto and including 20MVA 244 Above 20MVA 245 Loading of Power Transformer to Sub Station Bed/Platform 246 1MVA upto and including 2.5 MVA 247 Above 2.5MVA upto upto and including 6.3 MVA 248 Above 6.3 MVA upto upto and including 10MVA 249 Above 10 MVA upto upto and including 20MVA 250 Above 20MVA 251 Unloading of Power Transformer to Sub Station Bed/Platform 252 1MVA upto and including 2.5 MVA 253 Above 2.5MVA upto upto and including 6.3 MVA 254 Above 6.3 MVA upto upto and including 10MVA 255 Above 10 MVA upto upto and including 20MVA 256 Above 20MVA 257 Installation of new outgoing structures on PCC poles 9m with DO set, LA and other accessories. 258 Installation of new outgoing structures on ST poles 9m with DO set, LA and other accessories. 259 Installation/Testing and Commissioning of 11 KV Isolator, 800 A (with/without Earthing blade)conforming to IS 9921/IEC -129 601 standard 260 Replacement of 11KV D.O set 261 Replacement of 11KV LA set 262 Earthing complete with GI pipe/flat 263 Fencing of Switchyard with Mesh fencing,angle iron post complete along with cement bottoming of angle posts 264 Providing/installation of damaged/broken windows panes with fibre sheet of control room 265 Deweeding of vegetation in outer yard 266 Removing of Stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation ,levelling of area with existing stone metal 267 Providing additional stone metal and its carriage and laying in outdoor yard 268 Repair and maintenance of AC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc including suppply of material. 269 Repair and maintenance of DC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc 270 Painting of internal/external walls and roof with approved brand of distemper , doors and window of control room buiding with paint of approved brand like asian paint,nerolac etc 271 Fencing of Receiving Station with barbed wire,angle iron post complete with 7 horizontal wires and 2 cross wires along with cement bottoming of angle posts 272 Repair/Replacement of ceiling fan of control room building