Military Engineer Services-MES has published Repair / Replacement Of Apfc Panels , Servo Stabilizers And Allied Works At Mil Stn Pithoragarh Under Ge Pithoragarh. Submission Date for this Tender is 25-07-2020. Servo Stabilizer Tenders in GE Pithoragarh Uttarakhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Jul-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-07-2020 |
Name of Work: REPAIR / REPLACEMENT OF APFC PANELS, SERVO STABILIZERS AND ALLIED WORKS AT MIL STN PITHORAGARH UNDER GE PITHORAGARH. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 0.05 | DESCRIPTION OF ITEMS | |||
2 | 1 | M & L for earthing complete with using galvanized mild steel earth plate (Electrode) 600 mm x 600 mm x 6.0 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 50 mm dia GI pipe ‘light grade’ from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone agg) complete all as specified and directed. | 11 | Each | |
3 | 2 | Supply, installation, commissioning and testing in replacement of APFC panel of CPRI approved with IP 66 protection, capacity 100 KVAR powder coated factory made outdoor type of suitable size made of Robust steel sheet construction made from min 2.1 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:-\n | 1 | Each | |
4 | 2.01 | (a) Incoming MCCB 4 pole 200 Amp 35 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos | |||
5 | 2.02 | b) Multi functional 4 in 1 meter like Amp, Voltage, frequency, power factor as per capacity of panel = 01 No. | |||
6 | 2.03 | (c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three | |||
7 | 2.04 | (d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity. Size of capacitor is 5 KVAR = 3 Nos, 10 KVAR=2 No., 15 KVAR= 01 No. 25 KVAR=2 No. including indication lamp of each capacitor complete.\nMake of MCCB’s / Relay MCB / Power contactor : Legrand / L&T / Schneider / Havells \nMake of Capacitor : L&T / Schneider / Havells \n | |||
8 | 2.05 | (e) Microprocessor based 3 phase current transformer sencing relay 8 stage = 01 No( for operating of capacitor bank) | |||
9 | 2.06 | (f) Auto / Manually switch of capacitor bank | |||
10 | 2.07 | (g) PCC 1:2:4 type C-1 using 20 mm graded stone aggegate for installation / grouted of panel complete | |||
11 | 3 | Supply, installation, commissioning and testing in replacement of APFC panel of CPRI approved with IP 66 protection, capacity 50 KVAR powder coated factory made outdoor type of suitable size made of Robust steel sheet construction made not less than 2.10 mm thick steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate panel comprising with following:-\n | 1 | Each | |
12 | 3.01 | (a) Incoming MCCB 4 pole 100 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting – 01 Nos | |||
13 | 3.02 | b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No. | |||
14 | 3.03 | (c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three | |||
15 | 3.04 | (d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity. Size of capacitor is 5 KVAR = 3 Nos, 10 KVAR=2 No., 15 KVAR= 01 No. including indication lamp of each capacitor complete.\nMake of MCCB’s/Relay MCB/power contactor :- Legrand / L&T / Schneider / Havells \nMake of Capacitor : L&T / Schneider / Havells | |||
16 | 3.05 | (e) Microprocessor based 3 phase current transformer sencing relay 6 stage = 01 No( for operating of capacitor bank) | |||
17 | 3.06 | (f) Auto/Manually switch of capacitor bank | |||
18 | 3.07 | (g) PCC 1:2:4 type C-1 using 20 mm graded stone aggegate for installation / grouted of panel complete | |||
19 | 4 | S & F in replacement of standard duty resin filled capacitor for 5 KVAR, 440 V, 3 phase complete all as specified and directed. \nMake:- Legrand / L&T/ Schneider\nNote:- Necessary addition / altration required to adjust Capacitors in the panel shall be done by the contractor and no extra payment will be made to the contractor. | 12 | Each | |
20 | 5 | ~ Ditto~ all as per Item No.4 above but of 7.5 KVAR | 8 | Each | |
21 | 6 | ~ Ditto~ all as per Item No.4 above but of 10 KVAR | 8 | Each | |
22 | 7 | ~ Ditto~ all as per Item No.4 above but of 15 KVAR | 6 | Each | |
23 | 8 | S & F in replacement of contactor suitable upto 7.5 KVAR, 440 V, 3 phase, complete all as specified and directed. \nMake:- Legrand/L&T/Schneider\nNote : Necessary addition /altration required to adjust Capacitors in the panel shall be done by the contractor and no extra payment will be made to the contractor. | 6 | Each | |
24 | 9 | ~ Ditto~ all as per Item No.8 above but of 10 KVAR | 4 | Each | |
25 | 10 | ~ Ditto~ all as per Item No.8 above but of 15 KVAR | 4 | Each | |
26 | 11 | Supply, laying & testing in replacement for XLPE Cable size 120 Sqmm nominal cross section x 3.5 core insulated, screened, PVC bedded, galvanized steel strip or armoured, heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors / road / path / drains / culverts complete all as specified and directed . \nNote:- Excavation & eartwork shall be measured and paid separately under respective items, \nMake- Havells / Gloster / Polycab / Finolex / Grandlay / Paragon / Plaza | 100 | RM | |
27 | 12 | ~ Ditto~ all as per Item No. 12 above but of size 95 Sqmm 3.5 core. | 150 | RM | |
28 | 13 | ~ Ditto~ all as per Item No. 12 above but of size 70 Sqmm 3.5 core. | 100 | RM | |
29 | 14 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundations of poles / stay / struts etc, or for laying of cables and the like such work but not exc 10 Sqm on plan and n exc. 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed. | 56 | Cum | |
30 | 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. | 33 | Cum | |
31 | 16 | Removing excavated material (soil) at a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. | 20 | Cum | |
32 | 17 | M & L for brick protection cover of UG cable by using old size sub class 'B'' common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed. | 1.8 | Per \n1000 Nos. | |
33 | 18 | M & L for dry sand cushioning to underground cables in layer (8 cm thick before laying of cables and 15 cm thick after laying and stretching of cable) as in trenches for cable protection or under floor or in foundation and gentally hand ramming and consolidation complete all as specified and directed. \nNote:- Sand thickness shall be measured only 18 cm after punning . | 17 | Cum | |
34 | 19 | S&F in repair of galvanized iron pipe of 80 mm nominal dia light grade fixed to poles / road crossing / wall with clamps nuts, bolts and washers complete all as specified and directed. \nNote : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the unit item rate. | 18 | RM | |
35 | 20 | M & L for making horizontal bore hole under path / road of 80 mm bore size at the depth not less than 1.0 mtr below ground level for passing of LT underground cable complete all as specified and directed. | 3 | RM | |
36 | 21 | Supply, installation, commissioning and testing in replacement powder coated factory made panel board outdoor type confirming to IP 66 protaction, of suitable size made of Robust steel sheet construction made not less than 2.10 mm thick steel sheet with counter sunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate complete all as specified.\nThe panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- | 1 | Each \nJob | |
37 | 21.01 | (a) Aluminium bus bar of capacity 300 Amp for phase and 150 Amps for neutral. | |||
38 | 21.02 | (b) Incoming MCCB 4 pole 250 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos | |||
39 | 21.03 | (c) Outgoing MCCB 4 pole 200 Amp 25KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 02 Nos | |||
40 | 21.04 | (c) Outgoing MCCB 4 pole 63 Amp 16KA alongwith Spreader terminals with adjustable thermal setting ( ICS= 100% ICU) – 01 Nos .Make of MCCB’s : Legrand /Schenider/L&T/Havells | |||
41 | 21.05 | (d) Off load change over switch of capacity 250 Amp – 01 Nos | |||
42 | 21.06 | (e) Digital volt meter 0 to 500 volt with selector switch – 01 No | |||
43 | 21.07 | (f) Digital Amp meter 0 to 400 Amp with CT of suitable ratio and selector switch – 01 No | |||
44 | 21.08 | (g) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three | |||
45 | 22 | M & L for preparation of old painted surface of panel board by cleaning removing of the old paint by scracthing with wire bursh/sand paper etc and including denting/patching of broken/rusted surfaces etc and apply two coat of synthetic enamel paint by spray painting on inside/outside surface of panel, complete all as specified and directed. | 600 | Sqm | |
46 | 23 | M & L for fabrication of door surfaces of LT panel indoor/outdoor as per existing size / thickness/shape and fitted in the panel with door handle, formed gasket around doors, lock insets, earthing strips, door stay, hinges,rivets etc. including two coat of synthetic enamel paint by spray painting on inside/outside surface of panel, complete all as specified and directed. | 150 | KG | |
47 | 24 | Supply and fix in replacement of copper bus bar in the panel of exsiting size and capacity for phase and neutral with heat shrinkable including PVC sleeves in different colour codes for phase indication complete all as specified and directed. | 1 | KG | |
48 | 25 | ~Ditto~ all as per item No 24 above but aluminium bus bar | 6 | KG | |
49 | 26 | S & F in replacement of LED type phase indication lamp of Red / Blue / Green colour for phase indication in existing panels complete all as specified and directed . \nMake C&S/Converse /Salzer/Schneider Elect. | 24 | Each | |
50 | 27 | S & F in replacement of selector 3 way for checking of Amps in 3 phase at different position in existing panels complete all as specified and directed .\nMake C&S/Converse /Salzer/Schneider Elect. | 15 | Each | |
51 | 28 | ~Ditto~ all as per item No 27 above but for checking of voltage . | 15 | Each | |
52 | 29 | Supply and fix in repair Air circuit brakers (ACB) 4 pole 415 volts with micro processor release breaking capacity 50 KA manual fixed type of capacity 800 Amps 50 KA in existing panel including making incoming and outgoing connection and required necessary addition /altration to provide new ACBs complete all as specified and directed .\nMake : ABB / L&T / / Schinder / Siemens / Havells | 1 | Each | |
53 | 30 | S & F in replacement MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA of existing make model and type alonwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed .\nMake :- L&T / Legrand / Schinder / Indo asian / Leader\nNote : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. | 1 | Each | |
54 | 30.01 | ~Ditto~ all as per Item No.30 above but of MCCB 400 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA | 2 | Each | |
55 | 30.02 | ~Ditto~ all as per Item No.30 above but of MCCB 315 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA | 1 | Each | |
56 | 30.03 | ~Ditto~ all as per Item No.30 above but of MCCB 250 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA | 4 | Each | |
57 | 30.04 | ~Ditto~ all as per Item No.30 above but of MCCB 200 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA | 3 | Each | |
58 | 30.05 | ~Ditto~ all as per Item No.30 above but of MCCB 100 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA | 4 | Each | |
59 | 31 | Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance soft/loose soil and getting out including spreading of anti vegitation chemical on complete area etc. complete all as specified and directed . | 400 | Sqm | |
60 | 32 | S & F Digital volt meter 0 to 500 volt with selector switch complete all as specified and directed . | 10 | Each | |
61 | 33 | S & F Digital Amp meter 0 to 800 Amp with CT of suitable ratio and selector switch complete all as specified and directed . | 10 | Each | |
62 | 34 | Maintenance and complete overhauling of servo stablizer of capacity 200 KVA including disassmbling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing wornout parts re-assembling of parts including disconnection, connection, well cleaning the complete stablizer, oil tank, connection plate, de-carbonizing all joints, metal parts and making servo stablizer operating in manual and electric mode including all routine testing and calibration etc. and writing of SM / MES No. complete all as specified and directed . Note: (a) Spray painting of complete servo stablizer is included in the quoted rates. ' ( b) Any re-wiring / changing of cable required for funtioning of stablizer is included in the quoted rate.(c) Major Spares to be paid separately as given Below. | 2 | Each\nJob | |
63 | 34.01 | (a) Electronic cards including replacement of all worn - out parts like IC's , regulators, condensers, Triac, Transistors etc. | 1 | Each | |
64 | 34.02 | (b) Servo motor of 10 Kg. cm torque | 1 | Each | |
65 | 34.03 | (c) Micro switch. | 1 | Each | |
66 | 34.04 | (d) R.C. Network for motor | 1 | Each | |
67 | 34.05 | (e) Carbon Brushes | 2 | Each | |
68 | 34.06 | (f) New Transhformer Oil of 50 KV Die electric Strength. | 50 | Ltr | |
69 | 34.07 | (g) Dimmer as per existing capacity | 1 | Each | |
70 | 34.08 | (h) Gears as per existing capacity | 1 | Each | |
71 | 35 | Maintenance and complete overhauling of servo stablizer of capacity 5 KVA to 50 KVA including disassmbling of operating mechanism parts, well cleaning with petrol & CRC-226 and replacing wornout parts reassembling of parts including disconnection,connection, well cleaning the complete stablizer, oil tank, connection plate,de-carbonizing all joints, metal parts and making servo stablizer operating in manual and electric mode including all routine testing ,calibration complete as well as writing of SM/MES No. complete all as specified and directed . Note: (a) Spray painting of complete servo stablizer is included in the quoted rates. ' ( b) Any rewiring/changing of cable required for funtioning of stablizer is included in the quoted rate. (c) Major Spares to be paid separately as given Below. | 5 | Each\n Job | |
72 | 35.01 | (a) Electronic cards including replacement of all worn - out parts like IC's , regulators, condensers, Triac, Transistors Etc.- | 2 | Each | |
73 | 35.02 | (b) Servo motor of 10 Kg. cm torque | 1 | Each | |
74 | 35.03 | (c) Micro switch. | 1 | Each | |
75 | 35.04 | (d) R.C. Network for motor | 1 | Each | |
76 | 35.05 | (e) Carbon Brushes | 2 | Each | |
77 | 35.06 | (f) New Transhformer Oil of 50 KV Die electric Strength. | 60 | Ltr | |
78 | 35.07 | (g) Dimmer as per existing capacity | 1 | Each | |
79 | 35.08 | (h) Gears as per existing capacity | 1 | Each | |
80 | 36 | S&F in repair Aluminium Lugs / connectors of size 50 sqmm complete all as specified and directed | 10 | Each | |
81 | 37 | S&F in repair Aluminium Lugs / connectors of size 70 sqmm complete all as specified and directed | 10 | Each | |
82 | 38 | S&F in repair Aluminium Lugs / connectors of size 95 sqmm complete all as specified and directed | 10 | Each | |
83 | 39 | S&F in repair Aluminium Lugs / connectors of size 120 sqmm complete all as specified and directed | 10 | Each | |
84 | 40 | M & L Repairs & overhauling to LT ACBs of any capacity (400 A to 1000 A) of any make by removing out the breaker from the respective panels after taking proper electric shut down & disconnecting the breaker, checking it thoroughly for the defects & tripping system of the ACB and rectifing them, lubrication of moving contacts, overhauling of the ACB, replacement of wornout minor spares like springs, washers, levers, nuts & bolts etc reassembling , re-installation ,testing & commissioning of ACB complete all as specified and directed .\nNote :(i) Cost of lubricants, cleaning agents, testing tools and minor spares shall be deemed to be including in quoted rates.\n | 15 | Each\n Job | |
85 | 41 | Supply and fixing in repair of Moving Arcing contacts and adjust the contact pressure of LT ACB of any make any capacity complete all as specified and directed \n | 2 | Each | |
86 | 42 | Supply and fixing in repair of fixed Arcing contact and adjust the contact pressure of LT ACB of any make any capacity complete all as specified and directed \n | 2 | Each | |
87 | 43 | M & L for in replacement of main shaft assembly with crank & cam spacer of existing capacity (630/800 Amp) LT ACB of existing make & model and testing for proper operation complete all as specified and directed | 1 | Each | |
88 | 44 | M & L for replacement of Trip coil of LT ACB of any make any capacity complete all as specified and directed | 2 | Each | |
89 | 45 | Supply ,fixing ,commisioning and testing in replacement of Digital 24 Hr timer street light control panel of Max load 12 KW complete with contractor rating 65 / TP, MCB rating 63 Amp SPN complete all as specified and directed.\nNote :- CA No & date of installations shall be marked by paint on all timer switch provided by the contractor \nMake;- Havells / Indo asian / Legrand / L & T\n | 1 | Each | |
90 | 46 | M & L for glow sign board (box type) LED of required size 1200 X 900 mm made out of MS sheet of suitable size with flex sheet of suitable size with flex sheet fixed on front end quality marked with details of electric substation on front and rear with different colours including provision of LED power fittings & fixtures in equal distance to illuminate board including connections with 2.5 sqmm single core stranded copper conductor cable in conduit and wiring and fixing of MCB with weather proof box with 10 mm size letters complete all as specified and directed. | 2 | Each\n Job | |
91 | 47 | Material and Labour for Servicing the existing solar street light by checking the wire connection, and replace the worn out / UNSV tubular C 20 type rechargeble battery of Capacity 12 V, 150 AH, including replacement of existing MS battery box at entire satisfication of Engr in charge complete all as specified and directed. Make- Exide / Amaron / Wipro / Panasonic | 4 | Each | |
92 | 48 | M & L for in replacement of existing solar street light with 30 W LED street Light with in-built SCC suitable for solar panel including replacement of old burnt wiring of existing size for making funtional complete all as specified and directed by Engr-in-charge. | 4 | Each | |
93 | 49 | Supply and fix AC/DC charge controller unit suitable for 12 volts AC/DC solar street light fitted as per site requirement all as specified and directed. | 4 | Each | |
94 | 50 | M & L for replacement of solar burn out panel (SPV panel) suitable for solar street light SPV Panel of 30 W capacity including replacement of old burnt wiring of existing size complete all as specified and directed b. | 2 | Each | |
95 | 51 | M & L for grouting of LT/ APFC Panel by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate including shifting of existing LT/APFC panel with disconeection of existing cables and reconnecting after shifting and grouting of panel complete all as specified and directed | 3 | Each\n Job | |
96 | 52 | S & F in replacement MCB Tripple pole of capacity 20 Amp for suitable for existing APFC Panel contactor/capacitor complete all as specified and directed\nMake:- Legrand / L&T / ABB / Schinder\nNote : Necessary addition /altration required to adjust MCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. | 4 | Each | |
97 | 53 | S & F in replacement APFC Panel Relay micro processor based of 6/8/10 stage suitable for switching of APFC Panel contactor/capacitor complete all as specified and directed \nMake:- Legrand / L&T / ABB / Schinder\nNote : Necessary addition /altration required to adjust MCB in the panel shall be done by the contractor and no extra payment will be made to the contractor. | 1 | Each | |
98 | 54 | S&F in repair of galvanized iron pipe of 40 mm nominal dia light grade complete all as specified and directed. \nNote : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. | 12 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy