Military Engineer Services-MES has published Repair And Replacement Of Ac Sheet At Prc Area Temple Lane Ge Office And Mes Md Area At Ramgarh Cantt Under Ge Ramgarh. Submission Date for this Tender is 13-07-2020. Roofing Materials Tenders in GE RAMGARH Jharkhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Jul-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-07-2020 |
Name of Work : Repair and replacement of AC sheet at PRC area, Temple lane, GE office and MES MD area at Ramgarh Cantt under GE Ramgarh. | |||||
---|---|---|---|---|---|
Sl. No. | Description of Items | Item Code / Make | Quantity/ Nos of Units | Units | |
1 | 1 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges as in roof covering, complete all as specified and directed. | 1 | 1975 | SQM |
2 | 2 | S & F 6mm cement corrugated sheet fixed with 'L' type or 'J' type or cranked hook bolts, complete all as specified and as directed. | 2 | 1775 | SQM |
3 | 3 | All as per item No.2, here-in-before but except sheeting, complete all as specified and as directed. | 3 | 200 | SQM |
4 | 4 | S & F two piece adjustable serrated cement sheet ridge 6mm thick for corrugated or semi corrugated sheet, complete all as specified and as directed. | 4 | 175 | RM |
5 | 5 | Labour only for cleaning of old AC sheet with wire brush and repair to hole with M-Seal, rubber, washer etc., and fixed with L type or J type or cranked hook bolts if required, complete all as specified and as directed. | 5 | 200 | SQM |
6 | 6 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and directed. | 6 | 250 | SQM |
7 | 7 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. | 7 | 225 | SQM |
8 | 8 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. | 8 | 25 | SQM |
9 | 9 | Dismantling wrought or mild steel work of any description and in any position complete all as specified and directed. | 9 | 2.5 | QTL |
10 | 10 | M & L for roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., and welding counter sunk for holes and necessary gusset plates etc and similar work conforming to Fe-410W (Gde E-250 quality A) complete all as specified and directed by Engr-in-Charge. | 10 | 250 | KG |
11 | 11 | M & L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of aluminium red oxide primer, complete all as specified and directed by Engr-in-Charge. | 11 | 95 | SQM |
12 | 12 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) including cover fillet, complete all as specified and directed. | 12 | 250 | SQM |
13 | 13 | Dismantling of wooden scantling 40 Sqm and over in section fixed in any position as in unframed work, complete all as specified and as directed. | 13 | 0.5 | CUM |
14 | 14 | S & F second class hardwood scantling, clean sawn in any position and any description, complete all as specified and directed. | 14 | 0.5 | CUM |
15 | 15 | S & F for second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails sectional area exc. 6 sqcm but not exc. 13 sqcm complete all as specified and directed. | 15 | 85 | RM |
16 | 16 | M & L for anodised GI snap grid frame work of grid size 605x605 mm for false ceiling, complete all as specified and as directed. | 16 | 210 | SQM |
17 | 17 | M & L for non asbestos fibre cement building board (designer) 4 mm thick in ceiling fixed or laid/inserted to timber/GI/Aluminium frame work with screw, complete all as specified and as directed. | 17 | 210 | SQM |
18 | 18 | S & F hanger of 6mm dia G.I (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40x3mm size 60mm long and expansion hold fasteners 12.5 dia 40 mm long, complete all as specified and as directed. | 18 | 210 | SQM |
19 | 19 | M & L for 4 mm thick asbestos cement building board fixed to timber framed work with screws, complete all as specified and as directed. | 19 | 40 | SQM |
20 | 20 | M & L preparation or new asbestos cement plain building board on ceiling surfaces and applying two coats of oil bound distemper, complete all as specified and as directed. | 20 | 40 | SQM |
21 | 21 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and as directed. | 21 | 3 | CUM |
22 | 22 | Demolition of brick work or stone / boulder or concrete block masonry including all quoins, arches, pillars, etc. built in cement mortar complete all as specified and directed. | 22 | 3 | CUM |
23 | 23 | M & L for brick work with sub class 'B' bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 Kg/Sqcm) old size bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and as directed. | 23 | 3 | CUM |
24 | 24 | M & L for plastering 15mm thick on brick surfaces other than fair face of brickwork in CM 1:4, finishing surfaces even and fair without using extra cement complete all as specified. | 24 | 65 | SQM |
25 | 25 | M & L preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified & directed. | 25 | 65 | SQM |
26 | 26 | M & L for plain cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in coping etc., complete all as specified and directed. | 26 | 1.5 | CUM |
27 | 27 | M & L for 25 mm thick Cement concrete type B0 1:2:4 (12.5 mm graded aggregate) as in roof padding of RCC roof including finishing cement concrete surface even and smooth without using extra cement, complete all as specified and directed. | 27 | 75 | SQM |
28 | 28 | Supply only liquid integral water proofing compound of an approved make. | 28 | 20 | LTRS |
29 | 29 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | 29 | 175 | SQM |
30 | 30 | Material and labour for rendering 15mm thick in CM(1:4) finishing surface even and smooth without using extra cement, on surfaces of brick or concrete surfaces, complete all as specified and as directed. | 30 | 175 | SQM |
31 | 31 | M & L for preparation of new surfaces on wall of any description using sand paper and applying two coats of cement base paint, complete all as specified and as directed. \n | 31 | 175 | SQM |
32 | 32 | S & F in repair 150 mm PVC (SWR) pipes half rounded single socketed in any length for collecting rain water, including pipe joints for fixing on wall, complete all as specified and as directed. | 32 | 40 | RM |
33 | 33 | S & F in repairs for 150 mm PVC(SWR) reducer 150 mm to 110 mm half rounded single socketed in any length for collecting rain water, including pipe joint for fixing on wall, complete all as specified and as directed. | 33 | 6 | EACH |
34 | 34 | S & F in repair for 110 mm PVC(SWR) pipes single socketed, in any length with rubber ring joints fixed on wall, complete all as specified and as directed.\n | 34 | 30 | RM |
35 | 35 | S & F in repairs 110 mm PVC(SWR) bends, complete all as specified and as directed. | 35 | 10 | EACH |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy