Annual Maintenance And Repairs Of Water Supply Machineries For Year 2020-21 For Nagar Parishad , Risod Annual Maintenance And Repairs Of Water Supply Machineries For Year 2020-21 For Nagar Parishad , Risod Dist . Washim
Tender Overview
Project Description
Annual Maintenance And Repairs Of Water Supply Machineries For Year 2020-21 For Nagar Parishad , Risod Annual Maintenance And Repairs Of Water Supply Machineries For Year 2020-21 For Nagar Parishad , Risod Dist . Washim
BOQ
| Name of Work: Annual Maintenance and Repairs of Water supply machineries for year of 2020-2021 for Nagar Parishad, Risod Dist. Washim | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Labour charges for removing the pump set upto 15 m drop pipe etc complete. Submersible pumpset 150 mm dia 10.00 H.P | BI01010001010000000000000515BI0100001113 | 1 | No |
| 2 | 2 | Labour charges for removing the pump set upto 15 m drop pipe etc complete. Submersible pumpset 150 mm dia 20.00 H.P | BI01010001010000000000000515BI0100001114 | 1 | No |
| 3 | 3 | Labour charges for removing the pump set upto 15 m drop pipe etc complete. a) Submersible pumpset 150 mm dia 2. 15.00 H.P | BI01010001010000000000000515BI0100001115 | 1 | No |
| 4 | 4 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.b) Submersible monoblock ( vertical ) pumpset 1. 10.00 H.P | BI01010001010000000000000515BI0100001116 | 1 | No |
| 5 | 5 | Labour charges for removing the pump set upto 15 m drop pipe etc complete. b) Submersible monoblock ( vertical ) pumpset 2. 15.00 H.P | BI01010001010000000000000515BI0100001117 | 1 | No |
| 6 | 6 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.b) Submersible monoblock ( vertical ) pumpset 3. 20.00 H.P | BI01010001010000000000000515BI0100001118 | 1 | No |
| 7 | 7 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.c) Centrifugal monoblock pumpset 1. 5.00 H.P | BI01010001010000000000000515BI0100001119 | 1 | No |
| 8 | 8 | Labour charges for removing the pump set upto 15 m drop pipe etc complete. c) Centrifugal monoblock pumpset2. 7.5 H.P | BI01010001010000000000000515BI0100001120 | 1 | No |
| 9 | 9 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.c) Centrifugal monoblock pumpset 3. 10.00 H.P | BI01010001010000000000000515BI0100001121 | 1 | No |
| 10 | 10 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.c) Centrifugal monoblock pumpset 4. 50.00 H.P | BI01010001010000000000000515BI0100001122 | 1 | No |
| 11 | 11 | Labour charges for removing the pump set upto 15 m drop pipe etc complete. a) Submersible pumpset 150 mm Q.1. 10.00 H.P | BI01010001010000000000000515BI0100001123 | 1 | No |
| 12 | 12 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.a) Submersible pumpset 150 mm Q.2. 15.00 H.P | BI01010001010000000000000515BI0100001125 | 1 | No |
| 13 | 13 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.a) Submersible pumpset 150 mm Q.3. 3.20.00 H.P | BI01010001010000000000000515BI0100001126 | 1 | No |
| 14 | 14 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.a) Submersible monoblock ( vertical ) pumpset 1. 10.00 H.P | BI01010001010000000000000515BI0100001127 | 1 | No |
| 15 | 15 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.a) Submersible monoblock ( vertical ) pumpset 2. 15.00 H.P | BI01010001010000000000000515BI0100001128 | 1 | No |
| 16 | 16 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.a) Submersible monoblock ( vertical ) pumpset 3. 20.00 H.P | BI01010001010000000000000515BI0100001129 | 1 | No |
| 17 | 17 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.b) Centrifugal monoblock pumpset1. 5.00 H.P | BI01010001010000000000000515BI0100001130 | 1 | No |
| 18 | 18 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.b) Centrifugal monoblock pumpset 2. 7.5 H.P | BI01010001010000000000000515BI0100001131 | 1 | No |
| 19 | 19 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.b) Centrifugal monoblock pumpset3. 10.00H.P | BI01010001010000000000000515BI0100001132 | 1 | No |
| 20 | 20 | Labour charges for removing the pump set upto 15 m drop pipe etc complete.a) Submersible pumpset 150 mm Q.4. 50.00 H.P | BI01010001010000000000000515BI0100001133 | 1 | No |
| 21 | 21 | Labour charges for Assembling the pump set etc complete 150 mm .150 mm Q.. | BI01010001010000000000000515BI0100001134 | 1 | No |
| 22 | 22 | Labour charges for Assembling the pump set etc complete a) Submersible pumpset 150 mm dia.. 1. 10.00 H.P | BI01010001010000000000000515BI0100001135 | 1 | No |
| 23 | 23 | Labour charges for Assembling the pump set etc completea) Submersible pumpset 150 mm dia2. 15.00 H.P | BI01010001010000000000000515BI0100001136 | 1 | No |
| 24 | 24 | Labour charges for Assembling the pump set etc complete a) Submersible pumpset 150 mm dia 3. 20.00 H.P | BI01010001010000000000000515BI0100001137 | 1 | No |
| 25 | 25 | Labour charges for Assembling the pump set etc completeb) Submersible monoblock ( vertical ) pumpset 1. 10.00 H.P | BI01010001010000000000000515BI0100001138 | 1 | No |
| 26 | 26 | Labour charges for Assembling the pump set etc complete b) Submersible monoblock ( vertical ) pumpset 2. 15.00 H.P | BI01010001010000000000000515BI0100001139 | 1 | No |
| 27 | 27 | Labour charges for Assembling the pump set etc completeb) Submersible monoblock ( vertical ) pumpset 3. 20.00 H.P | BI01010001010000000000000515BI0100001140 | 1 | No |
| 28 | 28 | Labour charges for Assembling the pump set etc complete c) Centrifugal monoblock pumpset 1. 5.00 H.P | BI01010001010000000000000515BI0100001141 | 1 | No |
| 29 | 29 | Labour charges for Assembling the pump set etc complete c) Centrifugal monoblock pumpset 2. 7.5 H.P | BI01010001010000000000000515BI0100001142 | 1 | No |
| 30 | 30 | Labour charges for Assembling the pump set etc complete c) Centrifugal monoblock pumpset 3. 10.00 H.P | BI01010001010000000000000515BI0100001143 | 1 | No |
| 31 | 31 | Labour charges for Assembling the pump set etc complete c) Centrifugal monoblock pumpset 4. 50.00 H.P | BI01010001010000000000000515BI0100001144 | 1 | No |
| 32 | 32 | Labour charges for Rerection of pump set a) Submersible pumpset 150 mm Q. 1. 10.00 H.P | BI01010001010000000000000515BI0100001145 | 1 | No |
| 33 | 33 | Labour charges for Rerection of pump set a) Submersible pumpset 150 mm Q. 2. 15.00 H.P | BI01010001010000000000000515BI0100001146 | 1 | No |
| 34 | 34 | Labour charges for Rerection of pump set a) Submersible pumpset 150 mm Q.3. 20.00 H.P | BI01010001010000000000000515BI0100001147 | 1 | No |
| 35 | 35 | Labour charges for Rerection of pump set b) Submersible monoblock ( vertical ) pumpset 1. 10.00 H.P | BI01010001010000000000000515BI0100001148 | 1 | No |
| 36 | 36 | Labour charges for Rerection of pump set b) Submersible monoblock ( vertical ) pumpset 2. 15.00 H.P | BI01010001010000000000000515BI0100001149 | 1 | No |
| 37 | 37 | Labour charges for Rerection of pump set b) Submersible monoblock ( vertical ) pumpset 3. 20.00 H.P | BI01010001010000000000000515BI0100001150 | 1 | No |
| 38 | 38 | Labour charges for Rerection of pump set c) Centrifugal monoblock pumpset 1. 5.00 H.P | BI01010001010000000000000515BI0100001151 | 1 | No |
| 39 | 39 | Labour charges for Rerection of pump set c) Centrifugal monoblock pumpset 2. 7.5 H.P | BI01010001010000000000000515BI0100001152 | 1 | No |
| 40 | 40 | Labour charges for Rerection of pump set c) Centrifugal monoblock pumpset 3. 10.00H.P | BI01010001010000000000000515BI0100001153 | 1 | No |
| 41 | 41 | Labour charges for Rerection of pump set c) Centrifugal monoblock pumpset 4. 50.00 H.P | BI01010001010000000000000515BI0100001154 | 1 | No |
| 42 | 42 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) a) Centrifugal monoblock pumpset i) Single phase 1.00 H.P | BI01010001010000000000000515BI0100001155 | 1 | No |
| 43 | 43 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) a) Centrifugal monoblock pumpset ii) Three phase 5.00 H.P | BI01010001010000000000000515BI0100001156 | 1 | No |
| 44 | 44 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) a) Centrifugal monoblock pumpset 7.5. H.P | BI01010001010000000000000515BI0100001157 | 1 | No |
| 45 | 45 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) a) Centrifugal monoblock pumpset 10.00 H.P | BI01010001010000000000000515BI0100001158 | 1 | No |
| 46 | 46 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) a) Centrifugal monoblock pumpset 50.00 H.P | BI01010001010000000000000515BI0100001159 | 1 | No |
| 47 | 47 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) submersible motor pump of all types & makes with coated copper wire. i) Single phase 1.00 H.P | BI01010001010000000000000515BI0100001160 | 1 | No |
| 48 | 48 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) submersible motor pump of all types & makes with coated copper wire.ii) Three phase 3.00 H.P | BI01010001010000000000000515BI0100001161 | 1 | No |
| 49 | 49 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) submersible motor pump of all types & makes with coated copper wire Above 5.00 H.P, upto 10.00 H.p. | BI01010001010000000000000515BI0100001162 | 1 | No |
| 50 | 50 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) submersible motor pump of all types & makes with coated copper wire.Above 5.00 H.P, upto 10.00 H.p | BI01010001010000000000000515BI0100001163 | 1 | No |
| 51 | 51 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) submersible motor pump of all types & makes with coated copper wire.Above 1 5.00 H.P, upto 20.00 H.p | BI01010001010000000000000515BI0100001164 | 1 | No |
| 52 | 52 | Rewinding of electric motor of all types & remarks with copper wire, over halling with minior repairs, testing for the original speed & No. load consumption ( rate including scribed material ) submersible motor pump of all types & makes with coated copper wire. Above 20.00 H.P, upto 25.00 H.p | BI01010001010000000000000515BI0100001165 | 1 | No |
| 53 | 53 | Providing & fixing the new bush bearing | BI01010001010000000000000515BI0100001166 | 1 | No |
| 54 | 54 | Providing & fixing the new sleeve | BI01010001010000000000000515BI0100001167 | 1 | No |
| 55 | 55 | Truning the rotor for fixing sleeve & bush | BI01010001010000000000000515BI0100001168 | 1 | No |
| 56 | 56 | Providing & fixing thrust bearing for Upto & including 5.oo H.P Above 5.00 H.P, upto 10.00 H.p | BI01010001010000000000000515BI0100001169 | 1 | No |
| 57 | 57 | Providing & fixing thrust bearing for Upto & including 5.oo H.P Above 5.00 H.P, upto 10.00 H.p | BI01010001010000000000000515BI0100001170 | 1 | No |
| 58 | 58 | Providing & fixing thrust bearing for Upto & including 5.oo H.P Above 1 5.00 H.P, upto 20.00 H.p | BI01010001010000000000000515BI0100001171 | 1 | No |
| 59 | 59 | Providing & fixing thrust bearing for Upto & including 5.oo H.P Above 20.00 H.P, upto 25.00 H.p | BI01010001010000000000000515BI0100001172 | 1 | No |
| 60 | 60 | Providing and fixing new rotor of approved make for fallow a) Centrifugal pumpset Upto & including 5.oo H.P | BI01010001010000000000000515BI0100001173 | 1 | No |
| 61 | 61 | Providing and fixing new rotor of approved make for fallow a) Centrifugal pumpset Above 5.00 H.P, upto 10.00 H.p | BI01010001010000000000000515BI0100001174 | 1 | No |
| 62 | 62 | Providing and fixing new rotor of approved make for fallow a) Centrifugal pumpset Above 5.00 H.P, upto 10.00 H.p | BI01010001010000000000000515BI0100001175 | 1 | No |
| 63 | 63 | Providing and fixing new rotor of approved make for fallow a) Centrifugal pumpset Above 1 5.00 H.P, upto 20.00 H.p | BI01010001010000000000000515BI0100001176 | 1 | No |
| 64 | 64 | Providing and fixing new rotor of approved make for fallow a) Centrifugal pumpset Above 20.00 H.P, upto 25.00 H.p | BI01010001010000000000000515BI0100001177 | 1 | No |
| 65 | 65 | Providing and fixing bearing of approved make for electric motor Upto & including 5.oo H.P | BI01010001010000000000000515BI0100001178 | 1 | No |
| 66 | 66 | Providing and fixing bearing of approved make for electric motor Above 5.00 H.P, upto 10.00 H.p | BI01010001010000000000000515BI0100001179 | 1 | No |
| 67 | 67 | Providing and fixing bearing of approved make for electric motor Above 5.00 H.P, upto 10.00 H.p | BI01010001010000000000000515BI0100001180 | 1 | No |
| 68 | 68 | Providing and fixing bearing of approved make for electric motor Above 1 5.00 H.P, upto 20.00 H.p | BI01010001010000000000000515BI0100001181 | 1 | No |
| 69 | 69 | Providing and fixing bearing of approved make for electric motor Above 20.00 H.P, upto 25.00 H.p | BI01010001010000000000000515BI0100001182 | 1 | No |
| 70 | 70 | Providing and erecting voltmeter A.C 50 cycles /sec with 0 to 500 V of suitable range 144x144 ,sqm | BI01010001010000000000000515BI0100001183 | 1 | No |
| 71 | 71 | Providing and erecting voltmeter A.C 50 cycles /sec with 0 to 450 V of suitable range 144x144 sqm | BI01010001010000000000000515BI0100001184 | 1 | No |
| 72 | 72 | Providing and erecting power factor meter 150 mm diaflush or projection type suitable for 400 V , 50 c/s , 3 phase | BI01010001010000000000000515BI0100001185 | 1 | No |
| 73 | 73 | Supplying rubber matting of thickness are below with good insultor property | BI01010001010000000000000515BI0100001186 | 1 | No |
| 74 | 74 | Supplying flat flexible 3 core pvc shelthed submersible type copper cable. 3 core 1.5 sqm. | BI01010001010000000000000515BI0100001187 | 1 | No |
| 75 | 75 | Supplying flat flexible 3 core pvc shelthed submersible type copper cable. 3 core 1.5 sqm. | BI01010001010000000000000515BI0100001188 | 1 | No |
| 76 | 76 | Supplying flat flexible 3 core pvc shelthed submersible type copper cable. 3 core 1.5 sqm. | BI01010001010000000000000515BI0100001189 | 1 | No |
| 77 | 77 | Supplying flat flexible 3 core pvc shelthed submersible type copper cable. 3 core 1.5 sqm. | BI01010001010000000000000515BI0100001190 | 1 | No |
| 78 | 78 | Supplying flat flexible 3 core pvc shelthed submersible type copper cable. 3 core 1.5 sqm. | BI01010001010000000000000515BI0100001191 | 1 | No |
| 79 | 79 | Supplying & erecting bank of Mealisea polypropy lene condensers with the standard capacitor of 2,3,5,6,10,12,50 & 15 KVAR | BI01010001010000000000000515BI0100001192 | 1 | No |
| 80 | 80 | Providing & erecting contractor for following rating 1. Contractor rating 12 Amp | BI01010001010000000000000515BI0100001193 | 1 | No |
| 81 | 81 | Providing & erecting contractor for following rating 2. 10.00 H.P | BI01010001010000000000000515BI0100001194 | 1 | No |
| 82 | 82 | Providing & erecting contractor for following rating 3. 15.00 H.P | BI01010001010000000000000515BI0100001195 | 1 | No |
| 83 | 83 | Providing & erecting contractor for following rating 4. 20.00 H.P | BI01010001010000000000000515BI0100001196 | 1 | No |
| 84 | 84 | Providing & erecting contractor for following rating 5. Contractor rating 5. Contractor rating CM 150 Amp | BI01010001010000000000000515BI0100001197 | 1 | No |
| 85 | 85 | Providing & erecting contractor for following rating 6. Contractor rating CM 300 Amp | BI01010001010000000000000515BI0100001198 | 1 | No |
| 86 | 86 | Providing & erecting reply for following range. Upto & including 5.00 H,P | BI01010001010000000000000515BI0100001199 | 1 | No |
| 87 | 87 | Providing & erecting reply for following range. Above 5.00 H.P, to 10.00 H.p | BI01010001010000000000000515BI0100001200 | 1 | No |
| 88 | 88 | Providing & erecting reply for following range.Above 10.00 H.P, to 15.00 H.p | BI01010001010000000000000515BI0100001201 | 1 | No |
| 89 | 89 | Providing & erecting reply for following range.Above 15.00 H.P, to 20.00 H.p | BI01010001010000000000000515BI0100001202 | 1 | No |
| 90 | 90 | Providing & erecting reply for following range. Above 20.00 H.P, to 25.00 H.p | BI01010001010000000000000515BI0100001203 | 1 | No |
| 91 | 91 | Providing & erecting reply for following range.Above 25.00 H.P, to 50.00 H.p | BI01010001010000000000000515BI0100001204 | 1 | No |
| 92 | 92 | Providing & erecting reply for following range. Above 50.00 H.P, to 120.00 H.p | BI01010001010000000000000515BI0100001205 | 1 | No |
| 93 | 93 | Providing & erecting single phasing preventer unit for protection of pump | BI01010001010000000000000515BI0100001206 | 1 | No |
| 94 | 94 | Providing & supplying MCCB unit of following size 1. 16 Amp – 415 V | BI01010001010000000000000515BI0100001207 | 1 | No |
| 95 | 95 | Providing & supplying MCCB unit of following size 2. 32 Amp – 415 V | BI01010001010000000000000515BI0100001208 | 1 | No |
| 96 | 96 | Providing & supplying MCCB unit of following size 3. 64 Amp – 415 V | BI01010001010000000000000515BI0100001209 | 1 | No |
| 97 | 97 | Providing & supplying MCCB unit of following size 4. 100 Amp – 415 V | BI01010001010000000000000515BI0100001210 | 1 | No |
| 98 | 98 | Providing & supplying MCCB unit of following size 5. 200 Amp – 415 V | BI01010001010000000000000515BI0100001211 | 1 | No |
| 99 | 99 | Providing & supplying MCCB unit of following size 6. 300 Amp – 415 V | BI01010001010000000000000515BI0100001212 | 1 | No |
| 100 | 100 | Providing & supplying MCCB unit of following size 7. 400 Amp – 415 V | BI01010001010000000000000515BI0100001213 | 1 | No |
| 101 | 101 | Providing and erecting timer with coil for starter | BI01010001010000000000000515BI0100001214 | 1 | No |
| 102 | 102 | Providing supplying contact strip | BI01010001010000000000000515BI0100001215 | 1 | No |
| 103 | 103 | Labour charges for wiring of starter upto 5.00 H.P Above 10.00 H.P, to 15.00 H.p | BI01010001010000000000000515BI0100001216 | 1 | No |
| 104 | 104 | Labour charges for wiring of starter upto 5.00 H.P Above 15.00 H.P, to 20.00 H.p | BI01010001010000000000000515BI0100001217 | 1 | No |
| 105 | 105 | Labour charges for wiring of starter upto 5.00 H.P Above 20.00 H.P, to 25.00 H.p | BI01010001010000000000000515BI0100001218 | 1 | No |
| 106 | 106 | Labour charges for wiring of starter upto 5.00 H.P Above 25.00 H.P, to 50.00 H.p | BI01010001010000000000000515BI0100001219 | 1 | No |
| 107 | 107 | Labour charges for wiring of starter upto 5.00 H.P Above 50.00 H.P, to 120.00 H.p | BI01010001010000000000000515BI0100001220 | 1 | No |
| 108 | 108 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 80 mm Q | BI01010001010000000000000515BI0100001221 | 1 | No |
| 109 | 109 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 100 mm Q | BI01010001010000000000000515BI0100001222 | 1 | No |
| 110 | 110 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 150 mm Q | BI01010001010000000000000515BI0100001223 | 1 | No |
| 111 | 111 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 200 mm Q | BI01010001010000000000000515BI0100001224 | 1 | No |
| 112 | 112 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 250 mm Q | BI01010001010000000000000515BI0100001225 | 1 | No |
| 113 | 113 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 300 mm Q | BI01010001010000000000000515BI0100001226 | 1 | No |
| 114 | 114 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 350 mm Q | BI01010001010000000000000515BI0100001227 | 1 | No |
| 115 | 115 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 400 mm Q | BI01010001010000000000000515BI0100001228 | 1 | No |
| 116 | 116 | Providing and supplying spindle & gun metal check nut etc complete 1) Spindle 500 mm Q | BI01010001010000000000000515BI0100001229 | 1 | No |
| 117 | 117 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 80 mm Q | BI01010001010000000000000515BI0100001230 | 1 | No |
| 118 | 118 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 100 mm Q | BI01010001010000000000000515BI0100001231 | 1 | No |
| 119 | 119 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 150 mm Q | BI01010001010000000000000515BI0100001232 | 1 | No |
| 120 | 120 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 200 mm Q | BI01010001010000000000000515BI0100001233 | 1 | No |
| 121 | 121 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 250 mm Q | BI01010001010000000000000515BI0100001234 | 1 | No |
| 122 | 122 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 300 mm Q | BI01010001010000000000000515BI0100001235 | 1 | No |
| 123 | 123 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 350 mm Q | BI01010001010000000000000515BI0100001236 | 1 | No |
| 124 | 124 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 400 mm Q | BI01010001010000000000000515BI0100001237 | 1 | No |
| 125 | 125 | Providing and supplying spindle & gun metal check nut etc complete 2) Gun metal check nut 500 mm Q | BI01010001010000000000000515BI0100001238 | 1 | No |
| 126 | 126 | Providing and supplying startor of Make LT/LK 3.00 HP | BI01010001010000000000000515BI0100001239 | 1 | No |
| 127 | 127 | Providing and supplying startor of Make LT/LK 1.00 HP | BI01010001010000000000000515BI0100001240 | 1 | No |
| 128 | 128 | Providing and supplying startor of Make LT/LK 15.00 H.P | BI01010001010000000000000515BI0100001241 | 1 | No |
| 129 | 129 | Providing and supplying startor of Make LT/LK 20.00 H.P | BI01010001010000000000000515BI0100001242 | 1 | No |
| 130 | 130 | Providing and supply pipe wroach 30 | BI01010001010000000000000515BI0100001243 | 1 | No |
| 131 | 131 | Providing and supply pipe wroach 18 | BI01010001010000000000000515BI0100001244 | 1 | No |
| 132 | 132 | Providing and supply pipe wroach 14 | BI01010001010000000000000515BI0100001245 | 1 | No |
| 133 | 133 | Providing and supply pipe wroach 12 | BI01010001010000000000000515BI0100001246 | 1 | No |
| 134 | 134 | Providing and supply pipe wroach Diaset | BI01010001010000000000000515BI0100001247 | 1 | No |
| 135 | 135 | Providing and supply pipe wroach 1 | BI01010001010000000000000515BI0100001248 | 1 | No |
| 136 | 136 | Providing and supply pipe wroach ½ | BI01010001010000000000000515BI0100001249 | 1 | No |
| 137 | 137 | Providing electric supervisor for inspection & repair of minor fault. | BI01010001010000000000000515BI0100001250 | 1 | No |
| 138 | 138 | Providing and supplying meachanical gear griss | BI01010001010000000000000515BI0100001252 | 1 | No |
| 139 | 139 | Providing and fitting bearing no. 29324 | BI01010001010000000000000515BI0100001253 | 1 | No |
| 140 | 140 | Providing and fitting Vaccum pump for 50 HP centrifugal pump | BI01010001010000000000000515BI0100001254 | 1 | No |
| 141 | 141 | Dismelting charges | BI01010001010000000000000515BI0100001255 | 1 | No |
| 142 | 142 | Motor shaft new | BI01010001010000000000000515BI0100001256 | 1 | No |
| 143 | 143 | Guide shaft new | BI01010001010000000000000515BI0100001257 | 1 | No |
| 144 | 144 | Line shaft new | BI01010001010000000000000515BI0100001258 | 1 | No |
| 145 | 145 | Stainless steel sleeve | BI01010001010000000000000515BI0100001259 | 1 | No |
| 146 | 146 | Impellers shaft s.s. of pump | BI01010001010000000000000515BI0100001260 | 1 | No |
| 147 | 147 | Pump bowl bush | BI01010001010000000000000515BI0100001261 | 1 | No |
| 148 | 148 | Pump suction case bush | BI01010001010000000000000515BI0100001262 | 1 | No |
| 149 | 149 | Pump discharge case bush | BI01010001010000000000000515BI0100001263 | 1 | No |
| 150 | 150 | Pump stainer | BI01010001010000000000000515BI0100001264 | 1 | No |
| 151 | 151 | Pump tension tube | BI01010001010000000000000515BI0100001265 | 1 | No |
| 152 | 152 | Pump oil entry nut | BI01010001010000000000000515BI0100001266 | 1 | No |
| 153 | 153 | Sundry material | BI01010001010000000000000515BI0100001267 | 1 | No |
| 154 | 154 | Hydraulic testing & facing to oil tube | BI01010001010000000000000515BI0100001268 | 1 | No |
| 155 | 155 | Rewinding to 120 H.P. vertical hallow shaft motor.. | BI01010001010000000000000515BI0100001269 | 1 | No |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender