Construction of solar powered MDTW 2(two) pts at Halikuchi and 3 (Three) pts at jayantipur package 4

Corrigendum Details

Sr No CorrigendumDate Description Submission Date
1 26-06-2020 Corrigendum on BOQ 15-07-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 296234.00 /-
Tender Value
INR 1.48 Crore /-

Attachment

FileName File Description File Size
Bid4.pdf Tender Document-BID 1687.38
Drawings.PDF Tender Document-Drawings 4043.66
C287AC4F-D77A-45ED-A5DF-9DB9EC6097E3.html Tender Notice-Tender Notice 0
BOQ_27851.xls Tender Document-BOQ 342.50
Tendernotice_1.pdf Tender Document-NIT 1157.14

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work: Construction of solar powered MDTW 2(two) pts at Halikuchi and 3 (Three) pts at jayantipur package 4
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Construction Approach Road for 4 pts
2 1.01 Item No. 1: Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed.\nA) Ordinary soil 3237.5 m3
3 1.02 Item No. 2 : Collection and supply of sand and gravel (40% sand and 60% gravel) of size 13mm to 38mm from approved quarry including loading, unloading and stacking in measurable stacks at work site up to a height of 1.00m including payment of forest royality etc. 144 m3
4 1.03 Item No. 3 : Labour charges for spreading hard river shingles / sand gravels to required thickness over approach subway etc. including ramming, dressing the seat before laying the materials lead upto 30.00 M and lift 1.50 M. Complete as directed. 144 m3
5 2 Boring and Installation of Tube Well for 6 pts
6 2.01 Item No. 1 : Movement of drilling Rig , Tools & Plants, Accessories including drill pipes, casing pipes etc. to drilling site and back. 232.5 km
7 2.02 Item No. 2 : Boring of DTW of bore hole up to 450mm dia and up to a depth of 70 M or up to required depth by RC/DR Drilling Rig including supply and transportation of all required tools & Plants, materials & labour to site to perform the job in complete as directed in alluvium areas ( means areas where the strata comprises of loose, unconsiolidated materials like clays, silts, sands gravels, pebbles, cobbles and boulders) as per IS:2800 (part-1) of 1991. ( soil sample must be collected & keep properly at every 3.00 M interval of depth in boring. The job also include movement of rig by making temporary approach road etc. to the field up to distance of 1000M) 350 RM
8 2.03 Item No. 3 : Supply, lowering & installation in tube well 200mm PVC housing pipe / blind pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1997 of length 3.00 M of repute brand like Oriplast / Jindal / Prince etc. and as directed.\n\n( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation) 150 RM
9 2.04 Item No. 4 : Supply, lowering & installation in tube well 150mm PVC housing pipe / blind pipe of wall thickness of 6.5 mm to 8.5 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1997 of length 3.00 M of repute brand like Oriplast / Jindal / Prince etc. and as directed.\n\n( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation) 135 RM
10 2.05 Item No. 5 : Supply, lowering & installation in tube well 150mm PVC Ribbed Screen Filter pipe of wall thickness of 6.5 mm to 8.5mm for casing assembly including supply of sockets, reducer etc. as required as per IS : 12818-1997 of length 3.00 M/2.00 M of repute brand like Oriplast / Jindal / Prince etc. and as directed.\n( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation) 75 RM
11 2.06 Item No. 6 : Shrouding the DTW assembly by river pea gravel of size 4 mm to 8 mm free from sand / dust and any other foreign materials after screening / stacking at site including supply, transportation, labour etc. complete as directed. 82.5 Cum
12 2.07 Item No. 7 : Developing the tube well assembly by Air-Compressor of capacity 8-12 kg/cm2 and CFM=450 M3/min so as to get sand free discharge of water with supply of all required materials at site complete as directed including furnishing of litho-log / draw down data etc. as per IS : 11185 of 1999. ( For new DTW minimum 72 hours development is compulsory. Additional pea gravel required if any, during development would be extra )\nThe following data should be reflected in the report of development\n1. Static water level\n2. Drawdown at various discharge\n3. Available average discharge\n 360 Hrs
13 2.08 Item No. 8 : Supply, fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation need of water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10 , Part-I, Table-D. All materials construction and components should strickly conform to IS : 14846-2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe joining materials and painting in complete as directed.\n(i) 150mm dia 10 No
14 2.09 Item No. 9 : Supply, fitting-fixing of Heavy duty CIDF Reflex valve, swing check type with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table-D and the material, construction and all components should strictly conform to IS : 5312 (Part-I)-2004 and having arked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed.\n(i) 150mm dia 5 No
15 2.1 Item No. 10 : Supply, fitting-fixing of delivery pipes of 150 mm dia GI / fabricated GI pipes ( HD of repute brand with ISI marked) with flange at both end / wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed. 40 RM
16 2.11 Item No. 11 : Ftting-fixing of MS / GI bend of 150mm dia x 450 / 900 / 1200 with GI / fabricated GI pipes with flange at both end and pipe jointing sets, including painting as per drawing / specification as directed. 15 No
17 2.12 Item No. 12 : Supply, fitting-fixing of surge tank of size 900m dia x 1250mm long made of 4mm MS plate with raiser assembly of size 75mm dia x 6.0m long and S-band of size 200mm x 1600mm long made of 4mm MS plate including painting the above with one coat of synthetic enamel primer fllowed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified foundation by nuts & bolts of suitable size as per drawing & specification as directed. 5 No
18 3 Installation and commissioning of Solar PV Modules including Mounting Structure for 6 pts
19 3.01 Item No. 1 : Earth work in excavation of foundation trenches including filling up sides of trenches and removal of spoils after completion of foundation , dressing, ramming, shoring etc. complete including bailing out water where necessary in ordinary soil. 26.6 m3
20 3.02 Item No. 2 : Soling in foundation in floor at all level septic tank etc. including filling interstices ramming etc. complete as directed and as specified thickness \n(i) 9 cm brick on flat including sand packing. 25.2 m2
21 3.03 Item No. 3 : CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately). 2.25 m2
22 3.04 Item No. 4 : Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.\ni)Base:8mm\nii)Post:8mm\n 7.635 qntl
23 3.05 Item No. 5 : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).\n(C) Shuttering (Column) \ni)Base\nii)Post 84 m2
24 3.06 Item No. 6 : RCC work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including curing etc. with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately).\ni)Base\nii)Post 5 m3
25 3.07 Item No. 7 : Earthwork in back filling of structures, obtained from outside borrow pits filling in 15 cm layers, ramming, dressing, watering, including paying compensation of land if any (with lead up to 30 M and lift 1.5 M).\n\n 8.85 m3
26 3.08 Item No. 8:Supply, fitting, fixing and testing & commissioning of solar powered 7.5 HP oil / water cooled submersible pump set of reputed brand of discharge not less than 900 LPM at 10 metre Head ( total dynamic head of 20 M, pump should work upto 25 M head & shut off head 30 M ) of delivery size 80mm/100mm and drive rating 415 V, 50 Hz, 3-Phase Induction motor. 37.5 HP
27 4 Construction of Control Room for 6 pts
28 4.01 Item No. 1 : Earth work in excavation for foundation trenches including filling up sides of trenches and removal of spoils after completion of foundation , dressing, ramming, shoring etc. complete including bailing out water where necessary in ordinary soil. i) Long wall ii) Short wall 8.5 m3
29 4.02 Item No. 2 : CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately). i) Long wall ii) Short wall 2.15 m3
30 4.03 Item No. 3 : Brick work in cement mortar with 1st class brick as directde in foundation, retaining walls, plinth & steps including recking out joints & curing . i) Long wall ii) Short wall III) Less for post iv) step 11.95 m3
31 4.04 Item No. 4 : Providing 2 cm thick damp proof Course (D.P.C.) with cement motor in prop 1:2 with approved damp proofing compound. i) Below wall 10.75 m2
32 4.05 Item No. 5 : Earthwork in filing in plinth layer not more than 15 cm thick including necessary carriage, watering and ramming etc complete as directed and specified .Head load. (Lead up to 90 M and lift 2 M). i) Room ii) Veranda 15.5 m3
33 4.06 Item No. 6 : Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed. i) post 3.5 Qnl
34 4.07 Item No. 7 : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). i)shuttering (column) 31.15 m2
35 4.08 Item No. 8 : RCC work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including curing etc. with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately). i) post 2.85 m3
36 4.09 Item No. 9 : 125 mm thick 1st class brick nogged wall in cement mortar in prop 1:4 including racking out joints curing etc. complete as directed. 72.75 m2
37 4.1 Item No. 10 : 12 mm cement plastering including clearing surface and curing complete as directed. i) wall ii)plinth wall iii)post iv) step 230.3 m2
38 4.11 Item No. 11 : Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. \n(b) Using other ISI marked approved circular hollow section 2.45 Qntl
39 4.12 Item No. 12 : Providing galvanized C.I. sheet roofing including supplying fitting and fixing necessary galved, screws / iron "J" hooks bolts and nuts and washers etc. complete as directed including cost of roof truss (measurement on net roof area) 0.63 mm thickness (24 B.W.G). 62.9 sqm
40 4.13 Item No. 13: Providing 0.63 mm thick glaved ridging including suplying and fixing with necessary glaved. Screw washer etc. (23 cm lapping). 15 m2
41 4.14 Item No. 14 : Providing, fitting and fixing steel windows/ ventilators (openable) of standard rolled steel sections as per relevant I.S. Code-1038 joints mitred and welded with 15mmx3mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device and steel handles, peg stays of 300mm long etc. complete as per drawing including applying a priming coat of red-lead paint. \ni) Door\nii) window 14.4 sqm
42 4.15 Item No. 15 : Distempering two coats including painting two coats to batten with approved paint complete as directed. \ni) wall 145.5 m2
43 4.16 Item No. 16 : Soling in foundation in floor at all level septic tank etc. including filling interstices ramming etc. complete as directed and as specified thickness .\n(i) 9 cm brick on flat including sand packing. \na) room \nb) veranda 28.15 m2
44 4.17 Item No. 17 : Plain cement concrete floor base of thickness 63 mm thick in prop 1:3:6 with coarse aggregate of size 13 mm to 38 mm including curing etc. complete as specified.\na) Floor\nb) veranda 28.45 m2
45 4.18 Item No. 18 : 65 mm thick traced flooring with cement concrete in prop 1:2:4 with broken stone agg. of size 6 mm to 20 mm over one 1st class brick flat soling including sand packing of the voids in between the bricks, watering, ramming properly where necessary etc. complete and 12 mm thick cement plastering. Finishing on top trowelling altering curing complete as directed. (Brick soling to be paid seperately).\na)Floor\nb) veranda 28.45 m2
46 4.19 Item No. 19 : Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layers not exceeding 15 cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat of embankment and borrow pit area, breaking clods not more than 10 mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M, complete as directed. 220 m3
47 5 Underground PVC Pipe Distribution System for 4 pts
48 5.01 Item No. 1: Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. 2193.85 m3
49 5.02 Item No. 2 : Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).\na) Main line\n160 mm dia \n 2150 Rm
50 5.03 b)Branch line\n 110mm dia 1750 Rm
51 5.04 Item No. 3 : Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement, testing leakages etc. complete as directed.\nSize 160 mm x 160 mm x 110 mm\n 30 no
52 5.05 Item No. 4 : Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed.\nSize 160 mm x 110 mm 5 no
53 5.06 Item No. 5 : Supplying, fitting, fixing, joining of PVC end cap fitting with solvent cement as per specification including local carriage, testing leakage etc. complete as directed.\nSize : 110mm 35 no
54 6 Construction of ( 7 Nos.)Spout Chamber for (4 pts)
55 6.01 Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. 30.85 Cum
56 6.02 Item No. 2 : C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately). 10.3 Cum
57 6.03 Item No. 3 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4) 18.35 Cum
58 6.04 Item No. 4 : 12 mm cement plastering including clearing surface and curing complete as directed. \nIn prop. 1: 4 138.75 sqm
59 6.05 Item No. 5 : Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed. 35 No
60 6.06 Item No. 6 : Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed.\n110 mm / 900 35 No
61 6.07 Item No. 7 : Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).\n110mm dia 42 RM
62 7 Construction of Boundary Wall for (4 pts)
63 7.01 Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. 90 Cum
64 7.02 Item No. 2 : Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing. \nFlat brick soling\n 81 sqm
65 7.03 Item No. 3 : C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid.separately).\ni) wall post \nii) Gate post 7.3 Cum
66 7.04 Item No. 4 : R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).\ni) wall post \nii) Gate post\niii) Tie beam 31.6 Cum
67 7.05 Item No. 5 : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).\n(a) Shuttering (Column)\n 257.2 sqm
68 7.06 (b) Shuttering (Beams) with out props ,Tie beam 129.25 sqm
69 7.07 Item No. 6 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete.\n(a) In proportion 1:4\ni)Tie beam 30.3 Cum
70 7.08 Item No. 7 : 12 mm cement plastering including clearing surface and curing complete as directed. \nIn proportion 1:4\ni)Gate post\nii)Wall\n 532.8 sqm
71 7.09 Item No. 8 : Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.\n10mm dia\na) wall post footing (16 nos)\nb) Gate post footing ( 2nos)\n12mm dia\na) wall post footing (16 nos)\nb) Gate post footing ( 2nos)\nc) Tie beam (4)\n6 mm dia\na) wall post footing (16 nos)\nb) Gate post footing ( 2nos)\nc) Tie beam (1) 30 Qntl
72 7.1 Item No. 9 : Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts). 21.4 Qntl
73 7.11 Item No. 10 : Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed. 532.8 sqm
74 8 Construction of Supporting Pillar for (4 pts)
75 8.01 Item No. 1: Earth work in excavation of foundation of canal structures in all types of soil as per design and drawing dressing the foundation, shoring, etc. removing the surplus spoils by head load to a safe distance from the working place and depositing required spoils in uniform layers dressing, watering, breaking clods to not more than 10mm cube with compaction complete as directed at site (including bailing out stagnant water where necessary). \na. All type of soil except soil mixed with gravel and boulders\nFor normal lead of 30m and lift of 1.50m\n 22.05 Cum
76 8.02 Item No. 2 : Soiling in foundation floor at all levels including filling interstices,ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing. 12.15 sqm
77 8.03 Item No. 3: C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately). 1.2 Cum
78 8.04 Item No. 4 : R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately). 4.2 Cum
79 8.05 Item No. 5: Centering and shuttering including propping etc. where necessary and removal of forms after completion of C.C. and R.C.C. works as directed complete (measurement to be taken on the face area timbered). \ni)Column 40.1 sqm
80 8.06 Item No. 6 : Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. \n10mm dia\n12mm dia\n6mm dia 2.825 Qntl
81 8.07 Item No. 7: 12 mm thick cement plastering including clearing surface and curing complete as directed in prop. 1:4 33.35 sqm
82 9 Construction of Sign Board for (4 pts)
83 9.01 Item No. 1 : Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed. 5 No
Disclaimer :