| 1 | 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting for all leads and lifts excetra complete.\nItem / Page No : 2 / 197\nSpecification No : Bd.A.1\nSpec. Page No : 259\n | BI01010001010000000000000515BI0100001112 | 48.01 | Cubic Metre |
|---|
| 2 | 2 | Providing dry trap rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, excetra complete.\nItem / Page No : 38 / 201\nSpecification No : Bd.A.12\nSpec. Page No : 264\n | BI01010001010000000000000515BI0100001113 | 5.41 | Cubic Metre |
|---|
| 3 | 3 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork,laying/pumping, compacting and curing excetra complete, with fully automatic micro processor based Programmable Logic Control with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer. - With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)\nItem / Page No : 1 / 226\nSpecification No : Bd.E.1\nSpec. Page No : 287-288\nAdditional Specifications : With additional specifications for controlled concrete. | BI01010001010000000000000515BI0100001114 | 4.06 | Cubic Metre |
|---|
| 4 | 4 | Providing and laying in situ/Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)\nItem / Page No : 11 / 230\nSpecification No : Bd.F.3, B-7\nSpec. Page No : 298, 38-40\nAdditional Specifications : With additional specification for controlled concrete. | BI01010001010000000000000515BI0100001115 | 6.08 | Cubic Metre |
|---|
| 5 | 5 | Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor)\nItem / Page No : 31 / 232\nSpecification No : Bd.F.5, B-7\nSpec. Page No : 300, 38-40\nAdditional Specifications : With additional specification for controlled concrete. | BI01010001010000000000000515BI0100001116 | 4.66 | Cubic Metre |
|---|
| 6 | 6 | Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor)\nItem / Page No : 50 / 234\nSpecification No : Bd.F.6, B-7\nSpec. Page No : 300-301, 38-40\nAdditional Specifications : With additional specification for controlled concrete. | BI01010001010000000000000515BI0100001117 | 5.77 | Cubic Metre |
|---|
| 7 | 7 | Providing and fixing in position thermo mechnically treated FE-500 bar reinforcements of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)\nItem / Page No : 33 / 245\nSpecification No : Bd.F.17\nSpec. Page No : 306\n | BI01010001010000000000000515BI0100001118 | 1.204 | Metric Ton |
|---|
| 8 | 8 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor)\nItem / Page No : 5 / 254\nSpecification No : Bd.G.5\nSpec. Page No : 315\n | BI01010001010000000000000515BI0100001119 | 16.93 | Cubic Metre |
|---|
| 9 | 9 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor)\nItem / Page No : 11 / 269\nSpecification No : Bd.L.7\nSpec. Page No : 369\n | BI01010001010000000000000515BI0100001120 | 201.03 | Square Metre |
|---|
| 10 | 10 | Providing and applying two coats of waterproof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surfaces, watering for two days, excetra complete. (For Ground Floor)\nItem / Page No : 13 / 287\nSpecification No : Bd.O.8\nSpec. Page No : 406\n | BI01010001010000000000000515BI0100001121 | 201.03 | Square Metre |
|---|
| 11 | 11 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)\nItem / Page No : 1 / 338\nSpecification No : Bd.U.1\nSpec. Page No : 537\n | BI01010001010000000000000515BI0100001122 | 27 | Square Metre |
|---|
| 12 | 12 | Providing and fixing 50 milimetre diameter medium class Galvanised Iron Pipe gate with wicked gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in cement concrete block at top and bottom with locking arrangement incluing cutting, bending, making holes and with one coat of primer excetra complete.\nItem / Page No : 5 / 223\nAdditional Specifications : The work shall be done as per instructions of Engineer in charge. | BI01010001010000000000000515BI0100001123 | 11.2 | Square Metre |
|---|
| 13 | 13 | Providing and fixing heavy duty inter locking concrete coloured paving blocks of 60 milimetre thickness of having a strength of 300 kilogramme per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning, excetra complete.\nItem / Page No : 51 / 280\nAdditional Specifications : The work shall be carried out as per instructions of Engineer in charge. | BI01010001010000000000000515BI0100001124 | 50 | Square Metre |
|---|
| 14 | 14 | Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor.\nItem / Page No : 3 / 0\nAdditional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 67 Dated 15-5-2015 and Government of Maharashtra Public Works Department State Schedule of Rates 2017-18 General Note Number 4.3. 2. Above / below percentage quoted by the contractor will not be applicable for this item. | BI01010001010000000000000515BI0100001125 | 23.01 | Cubic Metre |
|---|
| 15 | 15 | Contribution towards District Mineral Foundation at the rate of 10 percent of prevailing rate of Royalty for various building construction bonafied materials which are used for government bonafied works and for which Royalty is to be paid by the contractor.\nItem / Page No : 10 / 0\nAdditional Specifications : 1. Government of Maharashtra, Industries, Energy and Labour Department Government Resolution Number MDF/0615/CR-34/IND-9 Dated 1-9-2016 and Section 2 thereof. 2. Above / below percentage quoted by the contractor will not be applicable for this item. | BI01010001010000000000000515BI0100001126 | 23.01 | Cubic Metre |
|---|
| 16 | 16.01 | Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.\nItem / Page No : 4 / 0\nAdditional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it.Compressive Strength of Cement Concrete Cube\n1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre | BI01010001010000000000000515BI0100001127 | 1 | Number |
|---|
| 17 | 16.02 | Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks\n1 Test per 50000.00 Number | BI01010001010000000000000515BI0100001128 | 1 | Number |
|---|
| 18 | 16.03 | Compressive Strength of Cement Mortar\n1 Test per Day | BI01010001010000000000000515BI0100001129 | 2 | Number |
|---|
| 19 | 16.04 | Compressive Strength, Water Absorption, Flexural Test, Resitance to wear Test for Paving Blocks - 60 milimetre thick, 300 Kilogram per Square Centimetre Strength\n1 Test per Square Metre | BI01010001010000000000000515BI0100001130 | 1 | Number |
|---|
| 20 | 17 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m X 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols excetra with approved colour shade paint complete, on M.S.angle of size 35 X 35 X 3 milimetre frame with properly cross braced mild steel angles of size 35mmx35mmx3mm duly painted including Two mild steel angle iron posts of size 65 milimetre X 65 milimetre X 6 milimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 centimetre X 60 centimetre X 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. number As directed by Engineer in Charge\nItem / Page No : 36 / 73\nSpecification No : MoRTH-801\nSpec. Page No : ---\nAdditional Specifications : The work shall be carried out as per instructions of Engineer in charge. | BI01010001010000000000000515BI0100001131 | 1 | Number |
|---|