Dairy Statutory Bodies & Commissions/Committees Closing in 0 days TDR #24691235

Amm. Screw Compressor, High Stage ( 5 Sst / +36 Sdt ) With Economizer, Oil Separator, Oil Filters, Thermossyphon Oil Cooler, Drive Motor And Vfd Complete With All Associated Accessories Minimum 6, 96, 000 Kcals /

Issued by Statutory Bodies & Commissions/Committees · , Multi State
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Jul 2020
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Multi State
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Amm. Screw Compressor, High Stage ( 5 Sst / +36 Sdt ) With Economizer, Oil Separator, Oil Filters, Thermossyphon Oil Cooler, Drive Motor And Vfd Complete With All Associated Accessories Minimum 6, 96, 000 Kcals / Hr For Each Compressor, Operating At 5° C Sst / 36°C Sdt ( Excluding Economizer Capacity ) Oil Loading & Unloading System Suitable For New Refrigeration Plant Thermosiphon Oil Cooling System Vessel Including Piping, Control, Instruments And Fittings Suitable For All High Stage & Low Stage Screw Compressors ( Considering Provision In Piping For Connecting 1 Additional Compressor In Each Stage In Future ) Amm .Reciprocating Compressor ( 5 Sst / +36 Sdt ) With Oil Separator, Oil Filters, Thermossyphon Oil Cooler, Drive Motor And Vfd Complete With All Associated Accessories Minimum 55, 000 Kcals / Hr Operating At 30° C Sst / 5° C Sdt Evaporative Condenser With Pump, Fans And All Accessories Capacity Of Each Condenser Shall Be Minimum 11, 20, 000 Kcals / Hr. Design Wet Bulb Temperature Is 28.7°C And Condensing Temperature 36°C Selection Of Condenser Shall Be Done With Extralarge Heat Transfer Surface Area To Facilitate Reduction In Power Consumption By Fan Motor And Pump. The Total Fan + Pump Motor Rating Shall Not Exceed 20.5 Kw. Evaporative Condenser With Pump, Fans And All Accessories ( To Be Installed In Place Of Existing Atmospheric Condenser For Existing Refri. System ) Capacity Of Each Condenser Shall Be Minimum 4, 20, 000 Kcals / Hr. Design Wet Bulb Temperature Is 28.7°C And Condensing Temperature 36°C Selection Of Condenser Shall Be Done With Extralarge Heat Transfer Surface Area To Facilitate Reduction In Power Consumption By Fan Motor And Pump. The Total Fan + Pump Motor Rating Shall Not Exceed 7.5 Kw. Liquid Ammonia Pump For 5 Deg C Liquid Accumulator Suitable For 5 ºc ( Sst ) Liquid Ammonia Pumping Of Flow Rate Minimum 12 Cu.Mt / Hr At 55 Mwc

AI Tender Summary

OUR REF NO 24691235
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 15-07-2020
Authority
Authority Name National Dairy Development Board
Work Description Amm. Screw Compressor, High Stage ( 5 Sst / +36 Sdt ) With Economizer, Oil Separator, Oil Filters, Thermossyphon Oil Cooler, Drive Motor And Vfd Complete With All Associated Accessories Minimum 6, 96, 000 Kcals / Hr For Each Compressor, Operating At 5° C Sst / 36°C Sdt ( Excluding Economizer Capacity ) Oil Loading & Unloading System Suitable For New Refrigeration Plant Thermosiphon Oil Cooling System Vessel Including Piping, Control, Instruments And Fittings Suitable For All High Stage & Low Stage Screw Compressors ( Considering Provision In Piping For Connecting 1 Additional Compressor In Each Stage In Future ) Amm .Reciprocating Compressor ( 5 Sst / +36 Sdt ) With Oil Separator, Oil Filters, Thermossyphon Oil Cooler, Drive Motor And Vfd Complete With All Associated Accessories Minimum 55, 000 Kcals / Hr Operating At 30° C Sst / 5° C Sdt Evaporative Condenser With Pump, Fans And All Accessories Capacity Of Each Condenser Shall Be Minimum 11, 20, 000 Kcals / Hr. Design Wet Bulb Temperature Is 28.7°C And Condensing Temperature 36°C Selection Of Condenser Shall Be Done With Extralarge Heat Transfer Surface Area To Facilitate Reduction In Power Consumption By Fan Motor And Pump. The Total Fan + Pump Motor Rating Shall Not Exceed 20.5 Kw. Evaporative Condenser With Pump, Fans And All Accessories ( To Be Installed In Place Of Existing Atmospheric Condenser For Existing Refri. System ) Capacity Of Each Condenser Shall Be Minimum 4, 20, 000 Kcals / Hr. Design Wet Bulb Temperature Is 28.7°C And Condensing Temperature 36°C Selection Of Condenser Shall Be Done With Extralarge Heat Transfer Surface Area To Facilitate Reduction In Power Consumption By Fan Motor And Pump. The Total Fan + Pump Motor Rating Shall Not Exceed 7.5 Kw. Liquid Ammonia Pump For 5 Deg C Liquid Accumulator Suitable For 5 ºc ( Sst ) Liquid Ammonia Pumping Of Flow Rate Minimum 12 Cu.Mt / Hr At 55 Mwc
Basic Detail
Tender No NDDB//20-21/ET/14
Bidding Type Tender
Location
City
State Multi State
Key Dates
Publish Date 25 Jun 2020
Submission Date 15 Jul 2020
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
c692f456-d6fc-48f5-a108-4d2d253d3e01.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 01, 1900
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

c692f456-d6fc-48f5-a108-4d2d253d3e01.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail