Description :DIGITAL ULTRA-VIOLET INTENSITY APPARTUS AS PER RDSO SPECIFICATION\rM&C/NDT/108(REV-1), REAFFIRMED, SEP2012 WITH FOLLOWING SPECIFICATION 1. ACCURACY: THE\rEQUIPMENT SHALL HAVE AN ACCURACY OF 75% WHEN MEASURED AGAINST A REFERENCE\rSTANDARD. 2.RANGE: THE MEASURING RANGE SHALL BE BETWEEN 0-19,990 micro watts per square\rcentimetre 3. FILTER: THE INTENSITY METER SHALL BE PROVIDED WITH A SPECIALLY CONTROLLED\rFILTER TO ALLOW RADIATION HAVING WAVELENGTH BETWEEN 330-390nm ONLY 4. DISPLAY: THE\rEQUIPMENT SHALL HAVE A MINIMUM 4DIGIT LED DISPLAY AND MINIMUM CONCESSION RATE OF\rTHREE READINGS PER SECOND. 5. RESOLVING POWER; THE METER SHALL HAVE RESOLUTION OF\r10 micro watt/centimetre square. 6. BATTERY: THE EQUIPMENT SHALL BE PROVIDED WITH 4X1.5V\rRECHARGEABLE Ni-cd BATTERY WITH A LIFE CYCLE OF 1000 RECHARGING.