Maintenance Of Summer Appliances And Ro Plant At Avadi Chennai, AVADI, CHENNAI-Tamil Nadu

Military Engineer Services-MES has published Maintenance Of Summer Appliances And Ro Plant At Avadi Chennai. Submission Date for this Tender is 28-07-2020. Air Conditioner Tenders in AVADI, CHENNAI Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

24683972
Corrigendum : Maintenance Of Summer Appliances And Ro Plant At Avadi Chennai
Open Tender
Indian
Tamil Nadu
AVADI, CHENNAI
28-07-2020

Tender Details

Maintenance Of Summer Appliances And Ro Plant At Avadi Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jul-2020 87615/E8DATE Date 21-07-2020
2 11-Jul-2020 87615/E8 TBIDCORRI Technical Bid 21-07-2020
3 21-Jul-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-07-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

NAME OF WORK: REPAIRS AND MAINTENANCE OF WINDOW / SPLIT ACs / WATER COOLER, RO PLANT AND SUMMER APPLIANCES AT AIR FORCE AND ARMY AREA UNDER GE AVADI, CHENNAI.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 BOQ UPLOADED ON 23 JUN 2020
2 2 MISCELLANEOUS ELECTRICAL ITEMS
3 3 Taking down existing unserviceable point wiring and taken on credit and provision of point wiring on stone / brick masonry wall complete with two 1.50 sqmm single core PVC insulated 1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia surface run on ceiling / walls and fixed with suitable clamps and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for for one 3 pin switch socket outlet, 5 Amps, on independent board complete all as specified and as directed. 24 POINT
4 3.01 Note:-
5 3.02 Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
6 4 All as per Sl Item No.1(a) here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour for for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed. 65 POINT
7 4.01 Note:-
8 4.02 Cost of terminal box and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
9 5 Taking down the existing unserviceable metal clad two pin and earth plug with MCB and taken on credit and replacing with metal clad two pin and earth plug and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 32 Amps, 10 kA, "C" Curve, 240 V complete all as specified and as directed. 34 EACH
10 6 Taking down the existing unserviceable metal clad two pin and earth plug with MCB and taken on credit and replacing with metal clad two pin and earth plug and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 20 Amps, 10 kA, "C" Curve, 240 V complete all as specified and as directed. 31 EACH
11 7 Sheet metal enclosures with socket plug top and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 20 Amps, 10 kA, "C" Curve, 240 V as in repairs complete all as specified and as directed. 53 EACH
12 8 Taking down carefully unserviceable sub main wiring aluminium conductor cables any number of runs of any cross section complete, including removal of batten / conduit and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed. 63 RUNNING METRE
13 9 Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor surface run on ceiling / walls and fixed with suitable clamps, screws etc., and connecting with terminal lugs complete all as specified and as directed. 63 RUNNING METRE
14 9.01 Note:-
15 9.02 (a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length.
16 9.03 (b) Cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
17 10 Taking down the existing unserviceable PVC insulated and sheathed flexible cable, copper conductor of size 3 core, 4 sqmm and taken on credit and replacing with new PVC insulated and PVC sheathed cable, copper conductor of size 3 core, 4 sqmm, 1100 volts grade complete all as specified and as directed. 57 RUNNING METRE
18 11 Taking down the existing unserviceable PVC insulated and sheathed flexible cable, copper conductor of size 3 core, 2.5 sqmm and taken on credit and replacing with new PVC insulated and PVC sheathed cable, copper conductor of size 3 core, 2.5 sqmm, 1100 volts grade complete all as specified and as directed. 56 RUNNING METRE
19 12 Preparing surfaces and writing letters such as SM No. & MES No. with black colour oil paint of ____mm width and ____ mm height complete all as specified and as directed. 141 EACH
20 13 Gun metal, globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed of bore of pipe 20mm as in repairs complete all as specified and as directed. 16 EACH
21 14 MAINT OF SUMMER APPLIANCES AND RO PLANT
22 15 Taking down the existing window type AC, 1.5 ton / 2.0 ton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil base bottom and fins, oiling / greasing of fan motor, checking of electrical wiring, replacement of worn out and short circuited wires, terminal clips etc., ensure smooth functioning and re-install and reconnect the AC unit in its exising location after proper cleaning of the place and testing and commissioning complete all as specified and as directed. 55 JOB
23 15.01 Notes:-
24 15.02 The major parts of the AC unit required to replaced and gas charging as required for smooth functioning of the AC unit shall be measured and paid separately vide items given here-in-after.
25 16 Taking down the existing split type AC, 1.5 ton / 2.0 ton capacity of any make / model from its position and cleaning the AC externally and servicing the AC including cleaning of condensor, filter, cooling coil base bottom and fins, oiling / greasing of fan motor, checking of electrical wiring, replacement of worn out and short circuited wires, terminal clips etc., ensure smooth functioning and re-install and reconnect the AC unit in its exising locations after proper cleaning of the places and testing and commissioning complete all as specified and as directed. 110 JOB
26 16.01 Notes:-
27 16.02 The major parts of the AC unit required to replaced and gas charging as required for smooth functioning of the AC unit shall be measured and paid separately vide items given here-in-after.
28 17 Taking down existing window type AC unit, repairing of opening in wall of size 1000mm x 600mm including necessary plaster and masonry patchwork in cement mortar 1:3, for proper reinstallation of window type AC unit, including plywood work and replacment of old thermacole around the AC for air tight fitting complete all as specified and as directed. 5 JOB
29 18 Taking down existing window type AC unit and dismantling old unserviceable timber framework and provision of timber framework, wrought in IInd class hardwood of section 100mm x 60mm, size of opening 1000mm x 600mm, for proper reinstallation of window type AC unit, including painting the exposed wooden surfaces with two coat of synthetic enamel paint over a coat of pink primer and tarring the hidden surfaces after due preparation of surfaces, suitable holdfasts of mild steel FI, duly tarred and sanded complete all as specified and as directed. 5 JOB
30 19 Tinkering work by removing dents etc, making good any holes by welding and brazing, and painting with one coat of synthetic enamel paint after due preparation of surfaces of base plate and fan motor base of window type AC, of any make / model complete all as specified and as directed. 9 JOB
31 20 Rewinding of blower motor having high and medium speed of window type AC, 1.5 ton capacity of any make / model with super enamelled copper winding of appropriate gauge and quality, including replacement of worn out bush, bearing, shaft metalling / grinding complete all as specified and as directed. 21 JOB
32 21 Rewinding of blower motor having high and medium speed of split type AC, 1.5 ton capacity of any make / model with super enamelled copper winding of appropriate gauge and quality, including replacement of worn out bush, bearing, shaft metalling / grinding complete all as specified and as directed. 23 JOB
33 22 Charging of window type AC, 1.5 ton capacity of any make / model with freon gas (R-22), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / bracing complete all as specified and as directed. 52 JOB
34 23 Charging of split type AC, 1.5 ton capacity of any make / model with freon gas (R-22 / R-32), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / bracing complete all as specified and as directed. 92 JOB
35 24 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for window type AC, 1.5 ton capacity of any make / model complete all as specified and as directed. 15 JOB
36 25 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for split type AC, 1.5 ton capacity of any make / model complete all as specified and as directed. 21 JOB
37 26 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for inverter type split AC, 1.5 ton capacity of any make / model complete all as specified and as directed. 2 JOB
38 27 Taking down the existing split type AC, 1.5 ton capacity of any make / model from its position and cleaning the AC externally, carrying out minor repairs and renewal of insulation materials for copper tubing as required for air tight fitting, ensure smooth functioning and re-install and reconnect the AC unit in its exising locations after proper cleaning of the places and testing and commissioning complete all as specified and as directed. 48 JOB
39 28 Taking down the existing unserviceable copper tubing of size 1/2 inch and taken on credit and replacing with new copper tubing of size 1/2 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed. 43 RUNNING METRE
40 29 Taking down the existing unserviceable copper tubing of size 1/4 inch and taken on credit and replacing with new copper tubing of size 1/4 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed. 42 RUNNING METRE
41 30 Taking down the existing unserviceable copper tubing of size 3/8 inch and taken on credit and replacing with new copper tubing of size 3/8 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed. 48 RUNNING METRE
42 31 Taking down the existing unserviceable copper tubing of size 5/8 inch and taken on credit and replacing with new copper tubing of size 5/8 inch for refrigent gas suitable for split type AC of any make / model complete all as specified and as directed. 39 RUNNING METRE
43 32 Sleeves for copper tubing any size for split type AC of any make / model as in repairs complete all as specified and as directed. 95 RUNNING METRE
44 33 Spring hose drainout for outdoor unit of split type AC of any make / model as in repairs complete all as specified and as directed. 85 RUNNING METRE
45 34 Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for window / split type AC, 1.5 ton capacity of any make / model complete all as specified and as directed. 38 JOB
46 35 Taking down the existing unserviceable GI bracket including all accessories and taken on credit and replacing with new GI bracket including all accessories suitable to fix outdoor unit of split type AC, of any make / model complete all as specified and as directed. 30 EACH
47 36 Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for window type / split type AC of any make / model complete all as specified and as directed.of 1.5 ton
48 36.01 (a) Condensor coil suitable for window type AC, 1.5 ton capacity. 6 JOB
49 36.02 (b) Evaporator coil suitable for window type AC, 1.5 ton capacity. 8 JOB
50 36.03 (c) Evaporator coil suitable for split type AC, 1.5 ton capacity. 9 JOB
51 36.04 (d) Running capacitor 36 Mfd. 81 EACH
52 36.05 (e) Running capacitor 50 Mfd. 66 EACH
53 36.06 (f) Starting capacitor 100-120 Mfd. 69 EACH
54 36.07 (g) Starting capacitor 80-100 Mfd. 68 EACH
55 36.08 (h) Starting relay 1622. 66 EACH
56 36.09 (j) Starting relay 1022. 61 EACH
57 36.1 (k) Overload protector 1622. 53 EACH
58 36.11 (l) Overload protector 1022. 52 EACH
59 36.12 (m) Running capacitor 4 Mfd. 48 EACH
60 36.13 (n) Thermostat switch. 46 EACH
61 36.14 (o) Selector switch knob. 36 EACH
62 36.15 (p) Condensor fan blade suitable for window type AC, 1.5 ton capacity. 36 EACH
63 36.16 (q) Blower for cooling coil suitable for window type AC, 1.5 ton capacity. 31 EACH
64 36.17 (r) Condensor fan blade suitable for split type AC, 1.5 ton capacity. 41 EACH
65 36.18 (s) Blower for cooling coil suitable for split type AC, 1.5 ton capacity. 25 EACH
66 36.19 (t) Blower motor double speed suitable for window type AC, 1.5 ton capacity. 28 EACH
67 36.2 (u) Evaporator motor double speed suitable for split type AC, 1.5 ton capacity. 26 EACH
68 36.21 (v) Condensor motor suitable for split type AC, 1.5 ton capacity. 22 EACH
69 36.22 (w) Remote control sensor and digital device complete set with remote suitable for split type AC, 1.5 ton capacity. 29 EACH
70 36.23 (x) PCB (mother board) suitable for split type AC, 1.5 ton capacity. 23 EACH
71 36.24 (y) Air filter suitable for window type AC, 1.5 ton capacity. 20 EACH
72 36.25 (z) Front grill suitable for window type AC, 1.5 ton capacity. 16 EACH
73 36.26 (aa) Oscillating motor / device to change direction of air flow suitable for split type AC, 1.5 ton capacity. 27 EACH
74 36.27 (ab) Magnetic coil suitable for split type AC, 1.5 ton / 2.0 ton capacity. 23 EACH
75 36.28 (ac) Remote control sensor and digital device complete set with remote suitable for inverter split type AC, 1.5 ton capacity. 3 EACH
76 37 Renewal with fabricated sheet metal upto to a height of 100mm from bottom of the refrigerator on all the sides and bottom with 2mm thick mild sheet and framework and painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after due preparation of surfaces to match the adjacent surfaces for refrigerator of capacity 300 lits / 315 lits complete all as specified and as directed. 1 JOB
77 38 Preparation of surface by removing dust, tinkering, applying metal putty wherever necessary and painting with two coats of synthetic enamel paint by spray painting of the following cooling appliances all as specified and as directed.
78 38.01 (a) Refrigerator of capacity 300 lits / 315 lits / 320 lits. 2 JOB
79 38.02 (b) Refrigerator of capacity 165 lits / 200 lits. 2 JOB
80 38.03 (c) Deep freezer of capacity 306 lits / 320 lits. 2 JOB
81 39 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for digital inverter refrigerator of any make / model and capacity 300 lits to 350 lits complete all as specified and as directed. 6 JOB
82 40 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for refrigerator capacity 165 lits / 200 lits of any make / model and complete all as specified and as directed. 6 JOB
83 41 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for refrigerator of capacity 300 lits to 320 lits of any make / model complete all as specified and as directed. 6 JOB
84 42 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for deep freezer of capacity 306 lits of any make / model complete all as specified and as directed. 4 JOB
85 43 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for deep freezer of capacity 300 lits / 320 lits of any make / model complete all as specified and as directed. 5 JOB
86 44 Servicing the refrigerator / freezer of any make, cutting the suction / discharge tubes of the compressor line and flushing, vacuuming and charging of refrigerator / freezer of any make / model with refrigerant gas (R-12/R-404), after dehydration as per standard practice, including detection of leaks and arresting the same by welding / bracing complete all as specified and as directed.
87 44.01 Notes:-
88 44.02 The major parts of the refrigerator / freezer required to replaced as required for smooth functioning of the refrigerator / freezer shall be measured and paid separately vide items given here-in-after.
89 44.03 (a) Refrigerator of capacity 165 lits. 7 JOB
90 44.04 (b) Refrigerator of capacity 300 lits / 315 lits. 12 JOB
91 44.05 (c) Deep freezer of capacity 306 lits / 320 lits. 9 JOB
92 45 Taking out the existing unserviceable digital electronic circuit board and taken on credit and replacing with new digital electronic circuit board suitable for digital inverter refrigerator of any make / model and capacity 300 lits / 350 lits complete all as specified and as directed. 6 EACH
93 46 Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for refrigerator / deep freezer of any make / model complete all as specified and as directed. 14 JOB
94 47 Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for refrigerators of any make / model complete all as specified and as directed.
95 47.01 (a) Magnetic door gasket suitable for refrigerator of capacity 300 lits / 315 lits 5 JOB
96 47.02 (b) Freezer (cooling coil) suitable for refrigerator of capacity 300 lits to 330 lits 5 JOB
97 47.03 (c) Freezer door set suitable for refrigerator of capacity 300 lits / 315 lits 5 JOB
98 47.04 (d) Thermostat switch with knob 6 EACH
99 47.05 (e) Relay box type suitable for refrigerator of capacity 165 to 315 lits. 8 EACH
100 47.06 (f) Relay open type suitable for refrigerator of capacity 165 to 315 lits. 6 EACH
101 47.07 (g) Timer switch suitable for refrigerator of capacity 165 to 315 lits. 6 EACH
102 47.08 (h) Bimetal suitable for refrigerator of capacity 165 to 315 lits. 6 EACH
103 47.09 (j) Heater suitable for refrigerator of capacity 165 to 315 lits. 5 EACH
104 47.1 (k) Blower motor suitable for refrigerator of capacity 165 to 315 lits. 4 EACH
105 47.11 (l) Running capacitor 4 Mfd suitable for refrigerator of capacity 165 to 315 lits. 8 EACH
106 47.12 (m) Door lock with key in duplicte suitable for refrigerator of capacity 165 to 315 lits. 10 EACH
107 47.13 (o) Pigmy lamp screw / pin type with holder suitable for refrigerator of capacity 165 to 315 lits. 14 EACH
108 47.14 (p) Ice box tray suitable for refrigerator of capacity 165 to 315 lits. 3 EACH
109 47.15 (q) Vegetable tray suitable for refrigerator of capacity 165 to 315 lits. 5 EACH
110 47.16 (r) Bottle tray suitable for refrigerator of capacity 165 to 315 lits. 5 EACH
111 47.17 (s) Shelves of inner panel suitable for refrigerator of capacity 165 to 315 lits. 5 EACH
112 48 Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for freezers of any make / model complete all as specified and as directed.
113 48.01 (a) Relay with OLP suitable for freezer of capacity 306 lits to 320 lits. 6 JOB
114 48.02 (b) Thermostat switch suitable for freezer of capacity 306 lits to 320 lits. 5 JOB
115 48.03 (c) Condensing motor suitable for freezer of capacity 306 lits to 320 lits. 5 JOB
116 48.04 (d) Starting capacitor 40 Mfd to 60 Mfd suitable for freezer of capacity 306 lits to 320 lits. 7 EACH
117 48.05 (e) Running capacitor 4 Mfd suitable for freezer of capacity 306 lits to 320 lits. 8 EACH
118 48.06 (f) Deep freezer door hinges with spring, screw etc suitable for freezer of capacity 306 lits to 320 lits. 5 EACH
119 48.07 (g) Hard PVC stand suitable for freezer of capacity 300 lits to 320 lits. 5 EACH
120 48.08 (h) Door shelves suitable for freezer of capacity 300 lits to 320 lits. 4 EACH
121 49 Renewal with fabricated sheet metal of base where compressor and condensor are mounted alongwith legs of angle iron and painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer after due preparation of surfaces for water coolers of capacity 120 lits / 150 lits complete all as specified and as directed. 6 JOB
122 50 Cleaning of tank and condensor unit, preparation of surface by removing dust, tinkering, applying metal putty wherever necessary and painting with two coats of synthetic enamel paint by spray painting entire unit of water coolers of capacity 120 lits / 150 lits all as specified and as directed. 5 JOB
123 51 Rewinding of condensor fan motor of water cooler 120 lits / 150 lits capacity of any make / model with super enamelled copper winding of appropriate gauge and quality, including replacement of worn out bush, bearing, base clamp with rubber "O" ring, shaft metalling / grinding complete all as specified and as directed. 2 JOB
124 52 Servicing the water coolers of any make, cutting the suction / discharge tubes of the compressor line and Flushing, vacuuming and charging of water cooler of any make / model with refrigerant gas, after dehydration as per standard practice, including detection of leaks and arresting the same by welding / bracing complete all as specified and as directed.
125 52.01 Notes:-
126 52.02 The major parts of the cooler required to replaced as required for smooth functioning of the cooler shall be measured and paid separately vide items given here-in-after.
127 52.03 (a) Water cooler of capacity 150 lits. 16 JOB
128 52.04 (b) Water cooler of capacity 120 lits. 19 JOB
129 53 Taking down the existing unserviceable compressor sealed unit and taken on credit and replacing with new compressor sealed unit, including flushing, vacuuming and charging with gas of required quantity, after dehydration as per standard practice, compressor suitable for deep freezer of capacity 300 lits / 320 lits of any make / model complete all as specified and as directed.
130 53.01 (a) Water cooler of capacity 150 lits. 7 JOB
131 53.02 (b) Water cooler of capacity 120 lits. 7 JOB
132 54 Taking down the existing unserviceable strainer and capillary tube and taken on credit and replacing with new strainer and capillary tube suitable for water cooler of any make / model complete all as specified and as directed. 22 EACH
133 55 Taking down the existing unserviceable short circuited wires and terminal clips and taken on credit and replacing with new short circuited wires and terminal clips suitable for water cooler of any make / model complete all as specified and as directed. 4 JOB
134 56 Taking down the existing unserviceable PVC hose as drain out pipe and taken on credit and replacing with new PVC hose pipe heavy duty 25mm dia drain out pipe for water cooler complete all as specified and as directed. 15 RUNNING METRE
135 57 Taking down the existing unserviceable PVC hose as drain out pipe and taken on credit and replacing with new PVC hose pipe heavy duty 40mm dia drain out pipe for water cooler complete all as specified and as directed. 14 RUNNING METRE
136 58 Taking down the existing unserviceable PVC water inlet pipe and taken on credit and replacing with new PVC pipe, transparent, heavy duty 20mm dia water inlet pipe for water cooler complete all as specified and as directed. 8 RUNNING METRE
137 59 Taking down the existing unserviceable PVC pipe as drain out pipe and taken on credit and replacing with new PVC pipe, heavy duty 50mm dia drain out pipe laid on walls / floor for water cooler complete all as specified and as directed. 12 RUNNING METRE
138 60 Taking down the existing unserviceable PVC pipe as drain out pipe and taken on credit and replacing with new PVC pipe, heavy duty 20mm dia drain out pipe laid on walls / floor for water cooler complete all as specified and as directed. 6 RUNNING METRE
139 61 Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for water coolers of capacity 120 lits / 150 lits of any make / model complete all as specified and as directed.
140 61.01 (a) Running capacitor 30 Mfd. 17 EACH
141 61.02 (b) Running capacitor 15 Mfd / 20 Mfd. 15 EACH
142 61.03 (c) Starting capacitor 60 Mfd to 80 Mfd. 19 EACH
143 61.04 (d) Starting capacitor 40 Mfd to 60 Mfd. 12 EACH
144 61.05 (e) Starting relay box type 1022. 12 EACH
145 61.06 (f) Starting relay 522. 9 EACH
146 61.07 (g) Starting relay 412. 10 EACH
147 61.08 (h) Overload protector 1022 10 EACH
148 61.09 (j) Overload protector 522 11 EACH
149 61.1 (k) Thermostat switch 9 EACH
150 61.11 (l) Float valve with ball of size 15mm. 23 EACH
151 61.12 (m) Push cock straight type nickel coated 15mm. 20 EACH
152 61.13 (n) Push cock angle type with round disc nickel coated 15mm. 15 EACH
153 61.14 (o) Plug top 3 pin 15 Amps 19 EACH
154 61.15 (p) Socket outlet 5 pin 5 / 15 Amps 19 EACH
155 61.16 (q) Rubber gasket for water cooler tank 7 EACH
156 61.17 (r) Door lock with key in duplicte suitable for water cooler tank 6 EACH
157 61.18 (s) PVC connection transparent, heavy duty, 15mm dia, 160mm long with rubber washer. 15 EACH
158 61.19 (t) Condensor coil . 1 EACH
159 62 Taking down the following existing spare parts and taken on credit and replacing with new spare parts suitable for voltage stabilizers of capacity 9 kVA / 5 kVA of any make / model complete all as specified and as directed.
160 62.01 (a) Main transformer 16 EACH
161 62.02 (b) Sub transformer 15 EACH
162 62.03 (c) Transistorised electronic relay. 13 EACH
163 62.04 (d) Electronic PC circuit plate having diodes, condensers etc., 17 EACH
164 62.05 (e) Voltmeter 0-300 Amps 13 EACH
165 62.06 (f) High / low voltage cut-off relay 16 EACH
166 62.07 (g) Time delay relay 15 EACH
167 62.08 (h) Output terminal contacts 13 EACH
168 62.09 (j) Socket outlet 5 pin 5 / 15 Amps 12 EACH
169 63 Disconnecting and dismantling of RO plant of capacity 250 LPH / 500 LPH etc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed 3 JOB
170 63.01 Notes:-
171 63.02 The major parts / accessories / spares of the water purifier required to replaced for smooth functioning shall be measured and paid separately vide items given here-in-after.
172 64 Supply only of the following parts / accessories / spares as required for RO plant of capacity 250 LPH complete all as specified and as directed
173 64.01 (a) Raw water pump 0.50 HP. 1 EACH
174 64.02 (b) Sand / carbon filter vessel 1054 1 EACH
175 64.03 (c) Sand bag 10 kg as 1 unit 2 EACH
176 64.04 (d) Fine Sand bag 10 kg as 1 unit 2 EACH
177 64.05 (e) Silex 10 kg as 1 unit 2 EACH
178 64.06 (g) Pebbles 10 kg as 1 unit 2 EACH
179 64.07 (h) Carbo bag 450 IV 10 kg as 1 unit 1 EACH
180 64.08 (j) Multiport volve 20 NB 2 EACH
181 64.09 (k) Dozing pump 1 EACH
182 64.1 (l) 20 feet housing filter 2 EACH
183 64.11 (m) 20 inch filter spun 5 EACH
184 64.12 (n) 20 inch wound 6 EACH
185 64.13 (o) Antiscalant liquid 6 LITRES
186 64.14 (p) High pressure pump (CRI) 2-100 1 EACH
187 64.15 (q) 40-40 membrane housing 2 EACH
188 64.16 (r) End cup 2 EACH
189 64.17 (s) End cup "O" ring 3 EACH
190 64.18 (t) Saddles and straps 2 EACH
191 64.19 (u) Membrane (Filmtech), (hydro nautics) 2 EACH
192 64.2 (v) Membrane connecter 3 EACH
193 64.21 (w) Auto electric panel 1 EACH
194 64.22 (x) Flow meter 0-600 2 EACH
195 64.23 (y) Flow meter 0-1200 2 EACH
196 64.24 (z) Pressure gauge 2 EACH
197 64.25 (aa) UPVC pipe 20mm dia and accessories 40 RUNNING METRE
198 64.26 (ab) Ball valve 1/4 inch 3 EACH
199 64.27 (ac) Ultra violet 250 LPH 2 EACH
200 64.28 (ad) Ultra violet clip 2 EACH
201 64.29 (ae) High pressure pump bold 8 EACH
202 64.3 (af) 50 litre tank 1 EACH
203 64.31 (ag) Membrane cleaning liquid 16 LITRES
204 64.32 (ah)Ball valve 1/2 inch 4 EACH
205 65 Disconnecting and dismantling of RO plant of capacity 15 LPH / 50 LPH etc.,and servicing / overhauling, cleaning of sand / carbon / micro filter / membrane filmtech, check water leakage in filters and pipe, re-installing, reconnecting, testing and commissioning for proper and smooth functioning complete all as specified and as directed 7 JOB
206 65.01 Notes:-
207 65.02 The major parts / accessories / spares of the water purifier required to replaced for smooth functioning shall be measured and paid separately vide items given here-in-after.
208 66 Supply only of the following parts / accessories / spares as required for RO plant of capacity 250 LPH complete all as specified and as directed
209 66.01 (a) Carbo granules filter 11 EACH
210 66.02 (b) 5-5 membrane and housing assembly 70 gpd 9 EACH
211 66.03 (c) Pressure pump 48 V 5 EACH
212 66.04 (d) Adaptor 48 V 3 EACH
213 66.05 (e) Carblack filter 5 EACH
214 66.06 (f) Micron filter 5 EACH