}

Supply Of Stent , Consumables , Guiding Catheter , Medicines Etc . Of Cardiology Department On Consignment Basis In Life Saving Medical Store , P . B . M . Hospital , Bikaner, PBM Hospital, Bikaner-Rajasthan

Medical College-MC has published Supply Of Stent , Consumables , Guiding Catheter , Medicines Etc . Of Cardiology Department On Consignment Basis In Life Saving Medical Store , P . B . M . Hospital , Bikaner. Submission Date for this Tender is 30-07-2020. Coats and Jackets Tenders in PBM Hospital, Bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

24680731
Corrigendum : Supply Of Stent , Consumables , Guiding Catheter , Medicines Etc . Of Cardiology Department On Consignment Basis In Life Saving Medical Store , P . B . M . Hospital , Bikaner
National Competitive Bid
Indian
Rajasthan
PBM Hospital, Bikaner
30-07-2020

Tender Details

Supply Of Stent , Consumables , Guiding Catheter , Medicines Etc . Of Cardiology Department On Consignment Basis In Life Saving Medical Store , P . B . M . Hospital , Bikaner-2 INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr.- 9Fr.)(Standard Length) US FDA/CE & DCGI APPROVED 3 Group A-2 4 LONG INTRODUCER SHEATH (30-50 cm long)(Size 5Fr.-9Fr.) US FDA/CE & DCGI APPROVED 5 LONG INTRODUCER SHEATH DEDICATED FOR TRANSRADIAL ACCESS Terumo- US FDA/CE & DCGI APPROVED 6 Transradial Sheath with unique thin wall technology. 7Fr Sheath has an Outer diameter of 2.8mm, 6Fr has and OD of 2.46 mm & 5Fr has an OD of 2.13mm. Hydrophillic M coating with 20/21G Surflash needle and TIF tip technology which provide optimal tapering design for smooth penetration 7 Group A-3 8 HYDROPHILIC DIAGNOSTIC GUIDE WIRE – RADIFOCUS TERUMO (REGULAR LENGTH, REGULAR STIFFNESS) – US FDA/CE & DCGI APPROVED 9 Group A-4 10 JUDKINS CATHETER (JR JL & PIGTAIL EBU, xb,xbr(Terumo, Cordis, Meditronic, Boston Scientific, Translumina) US FDA/CE & DCGI APPROVED 11 MULTIPURPOSE CATHETER (Cordis, Meditronic, Boston Scientific, Translumina) US FDA/CE & DCGI APPROVED 12 AMPLATZ CATHETER (Cordis, Meditronic, Boston Scientific, Translumina) US FDA/CE & DCGI APPROVED 13 INTERNAL MAMMARY CATHETER US FDA/CE & DCGI APPROVED 14 BY-PASS GRAFT CATHETER US FDA/CE & DCGI APPROVED 15 NIH CATHETER US FDA/CE & DCGI APPROVED 16 COURNARD CATHETER US FDA/CE & DCGI APPROVED 17 Double lumen Thrombo-Aspiration Catheter 18 IABP Catheter With Accessories 19 Swan Ganz Catheter 20 GUIDE EXTENSION CATHETER 21 Embolectomy Catheter 22 Ikari Left & Ikari Right Guiding for Extra backup through Radial route. 23 Vascular closure device with Bio absorbable PGA suture that provide a secure seal, , Bioabsorbable collagen designed to conform to the arteriotomy for confident closure, and low profile Bioabsorbable Anchor (50:50 blend glycolideand lactide polyer) to fit closely against arterial wall leaving blood flow undistributed while maintaining Vessel diameter againt. 24 Group B-1 25 PTCA INFLATION DEVICE - US FDA/CE & DCGI APPROVED 26 (HAEMOSTATIC Y-CONNECTOR) FOR PTCA – PUSH MECHANISM - US FDA/CE & DCGI APPROVED 27 Group B-2 28 MANIFOLD WITH ATTACHED TUBINGS (ANGIO KIT) with 3 Port - US FDA/CE & DCGI APPROVED 29 PRESSURE TRANSDUCER DOMES WITH PRESURE LINE LINK 30 Group B-3 31 PTCA GUIDE WIRE – REGULAR LENGTH, REGULAR SHAFT SUPPORT AND FLOPPY TIP US FDA/CE & DCGI APPROVED 32 PTCA GUIDE WIRE – REGULAR LENGTH, EXTRA - SUPPORT SHAFT AND FLOPPY TIP US FDA/CE & DCGI APPROVED 33 PTCA GUIDE WIRE – EXCHANGE LENGTH US FDA/CE & DCGI APPROVED 34 PTCA GUIDE WIRE – HYDROPHILIC COATED, REGULAR LENGTH US FDA/CE & DCGI APPROVED 35 PTCA GUIDE WIRE – HYDROPHILIC COATED, EXCHANGE LENGTH US FDA/CE & DCGI APPROVED 36 PTCA GUIDE WIRE - .014 One Piece core wire with jointless spring coil with sion Tech, Extra support wire with 8.5com spring coil having composite core with ACTONE inside, length 20cm with, tip load .5g, 190cm length tip radiopacity 3cm. (Sion Blue ES) US FDA/CE & DCGI APPROVED 37 RUN THROUGH NS PTCA WIRE FLOPPY. EXTRA FLOPPY INTERMEDIATE & HYPERCOAT Including CTO Wires 38 Group B-4 39 MICRO CATHETER TO BE USED FOR CTO Fine Cross ANTEGRADE AND RETROGRADE APPORCH. - US FDA/CE & DCGI APPROVED 40 Group B-5 41 PTCA BALLOON (SEMI-COMPLIANT) - US FDA/CE & DCGI APPROVED 42 PTCA BALLOON (NON-COMPLIANT) - US FDA/CE & DCGI APPROVED 43 PTCA Ballon with 0.75 MM Dia meter 44 PTCA Balloon Ryuri 45 PTCA Balloon Tazuna 46 PTCA Balloon Ryujin Plus 47 Sirolimus drug Eluting balloon with Nano carriers CE MARKED 48 High pressure PTCA dilatation catheter with small entry profile of 0.43mm and small balloon profile of 0.034” with special silicon coating on balloon to avoid Mellon seed effect. 49 LESION ENTRY PROFILE - 0.016/NOMINAL PRESSURE - 12 BARS/RBP - 22 BARS/IMPECCABLE TIP/HYDROPHILIC COATED/ NON-COMPLIANT BALLOON/ PRIME SHAFT 50 DUAL LAYER/RBP 35 BARS/ABP 45 BARS/STRICTLY NON-COMPLIANT 51 Group B-6 52 CUTTING BALLOON FOR PTCA HAVING MICROSURGICAL ATHEROTOMES (BLADES) - US FDA/CE & DCGI APPROVED 53 Group B-7 54 Wire Based Scoring Balloon Cathethr. US FDA/CE & DCGI APPROVED 55 Group B-8 56 STAINLESS STEEL CORONARY STENTS, PREMOUNTED ON BALLOON – US FDA/CE & DCGI APPROVED 57 STAINLESS STEEL CORONARY STENTS, PREMOUNTED ON BALLOON – US FDA/CE & DCGI APPROVED 58 COBALT CHROMIUM CORONARY STENTS, PREMOUNTED ON BALLOON – US FDA/CE & DCGI APPROVED 59 COBALT CHROMIUM CORONARY STENTS, PREMOUNTED ON BALLOON – US FDA/CE & DCGI APPROVED 60 COVERED CORONARY STENTS – US FDA/CE & DCGI APPROVED 61 STAINLESS STEEL RENAL STENTS, PREMOUNTED ON BALLOON – US FDA/CE & DCGI APPROVED 62 Group B-9 nDRUG ELUTING STENTS 63 JATROLIMUS ELUTING STENT - US FDA/CE & DCGI APPROVED 64 Abluminally coated Sirolimus eluting thin struts Microporus chromium cobalt stent with Bio absorbable-polymer matrix, where balloon is also coated with Sirolimus US FDA/CE & DCGI APPROVED 65 Abluminally coated Sirolimus eluting thin struts Microporus Stain less Steel stent with Bio absorbable-polymer matrix, where balloon is also coated with Sirolimus US FDA/CE & DCGI APPROVED 66 Sirolimus eluting Stent Cobalt Chromium With Diameter of 2mm to 4.5mm with length of 8mm to 48mm with biogradable polymer. US FDA/CE & DCGI APPROVED 67 BIOLIMUS ELUTING STENT - US FDA/CE & DCGI APPROVED 68 TACROLIMUS ELUTING STENT - US FDA/CE & DCGI APPROVED 69 DRUG ELUTING BIODEGRADABLE POLYMER & SHELLAC RESIGN TOP COAT US FDA/CE & DCGI APPROVED 70 EVEROLIMUS ELUTING chromium cobalt Multi link drug eluting stent - US FDA/CE & DCGI APPROVED 71 EVEROLIMUS ELUTING chromium cobalt Multi link 48mm drug eluting stent - US FDA/CE & DCGI APPROVED 72 EVEROLIMUS ELUTING chromium cobalt Multi link drug eluting stent - US FDA/CE & DCGI APPROVED 73 Everolimus Eluting platinum chromium stent US FDA APPROVED 74 Everolimus Eluting platinum chromium stent Bio absorvbale polymer stent US FDA/CE & DCGI APPROVED 75 EVEROLIMUS ELUTING chromium cobalt Semi-Closed Design US FDA/CE & DCGI APPROVED 76 Sirolimus eluting Stent Cobalt Chromium With 2 links & 8 CrownsWith Diameter of 2mm to 4.5mm with length of 8mm to 38mm with biogradable polymer And GRADIENT coating. US FDA/CE & DCGI APPROVED 77 BIODEGRADABLE POLYMER/MICROPOROUS SURFACE/SIROLIMUS DRUG & SHELLAC RESIGN/ABLUMINAL COATING/TEMPERATURE CONTROL DEVICE-TAG ALERT US FDA/CE & DCGI APPROVED 78 DUAL DRUG POLYMER FREE STENT/ PLAT FORM-COBALT CROMIUM/PROBUCOL DRUG INSTEAD OF POLYMER/MICROPOROUS SURFACE/ABLUMINAL COATING/SHELLAC RESIN/STRUT THICKNESS 79MICRON 79 Group B-10 80 BALLOON EXPANDABLE PULMONARY ARTERY STENTS – US FDA/CE & DCGI APPROVED 81 IVC STENTS SELF EXPENDABLE - US FDA/CE & DCGI APPROVED 82 Group B-11 83 STENTS WITH EPC CAPTURING TECHNOLOGY - US FDA/CE & DCGI APPROVED 84 BIODEGRADABLE CORONARY STENTS - US FDA/CE & DCGI APPROVED 85 Group C 86 INJECTION NIKORANDIL (2 mg) 87 INJECTION TIROFIBAN (100ml) 88 INJECTION EPTIFIBATIDE (100ml) 89 INJECTION ABCIXIMAB (BOLUS) 90 INJECTION FONDARINAUX (2.5 mg) 91 INJECTION FONDARINAUX (5.0mg) 92 INJECTION TENETEPLASE 30MG 93 INJECTION TENETEPLASE 40MG 94 Tablet Eplerenane 25mg 95 Tablet IVABRADINE 5mg 96 Tablet NIKORANDIL 5mg 97 Group D-1 98 ASD CLOSURE DEVICES WITH DELIVERY SYSTEM – US FDA/CE & DCGI APPROVED 99 ASD CLOSURE DEVICES WITHOUT DELIVERY SYSTEM – US FDA/CE & DCGI APPROVED 100 DELIVERY SHEATH FOR ASD CLOSURE DEVICE – US FDA/CE & DCGI APPROVED 101 PRELOADED ASD CLOSURE DEVICES – US FDA/CE & DCGI APPROVED 102 FENESTRATED SHEATH AND CLOSURE DEVICE US FDA/CE & DCGI APPROVED 103 PFO CLOSURE DEVICE- US FDA/CE & DCGI APPROVED 104 LEFT ATRIAL APPENSAGE CLOSURE DEVICE US FDA/CE & DCGI APPROVED 105 PFO CLOSURE DEVICES WITH DELIVERY SYSTEM – US FDA/CE & DCGI APPROVED 106 SIZING BALLOON FOR DEVICE CLOSURE – CIRCULAR SHAPE - US FDA/CE & DCGI APPROVED 107 SIZING BALLOON FOR DEVICE CLOSURE – OVAL SHAPED - US FDA/CE & DCGI APPROVED 108 SIZING PLATE FOR DEVICE CLOSURE - US FDA/CE & DCGI APPROVED 109 DELIVERY CABLE FOR ASD/VSD/PDA DEVICES - US FDA/CE & DCGI APPROVED 110 RETRIEVERS FOR ASD/VSD/PDA DEVICES - US FDA/CE & DCGI APPROVED 111 SEATH FOR RETRIVAL OF DEVICES - US FDA/CE & DCGI APPROVED 112 Group D-2 113 VSD CLOSURE DEVICES WITH DELIVERY SYSTEM – US FDA/CE & DCGI APPROVED 114 PDA CLOSURE DEVICES WITH DELIVERY SYSTEM – US FDA/CE & DCGI APPROVED 115 Group D-3 116 PDA CLOSURE DEVICES WITHOUT DELIVERY SYSTEM – US FDA/CE & DCGI APPROVED 117 Group D-4 118 EMBOLISATION COILS (0.018 INCH) - US FDA/CE & DCGI APPROVED 119 EMBOLISATION COILS (0.035 INCH) - US FDA/CE & DCGI APPROVED 120 EMBOLISATION COILS (0.052 INCH) - US FDA/CE & DCGI APPROVED 121 EMBOLISATION Plugs and Foam 122 Group E 123 INTRAVASCULAR RETRIEVER – SNARE (‘AMPLATZ GOOSENECK’ TYPE) - US FDA/CE & DCGI APPROVED 124 SHEATHS FOR INTRAVASCULAR SNARES - US FDA/CE & DCGI APPROVED 125 Group F-1 126 VERTEBRAL CATHETER - US FDA/CE & DCGI APPROVED 127 COELIAC AXIS CATHETER - US FDA/CE & DCGI APPROVED 128 SHEPHERD’S HOOK CATHETER - US FDA/CE & DCGI APPROVED 129 MICROCATHETER (Coiled Stainless steel construction) - US FDA/CE & DCGI APPROVED 130 Group F-2 131 High Pressure Angioplasty Balloon for peripheral vascular use – US FDA/CE & DCGI APPROVED 132 Group F-3 133 Peripheral Stent Balloon expandable (OTW/RX) – US FDA/CE & DCGI APPROVED 134 Group F-4 135 Self-Expanding peripheral stent – US FDA/CE & DCGI APPROVED 136 Group F-5 137 IVC Filter – US FDA/CE & DCGI APPROVED 138 Group G-1 139 VVIR PACEMAKER PERMANENT PACEMAKERS WITH ALL LEADS AND ACCESSORIES With Life time Warranty., US FDA/CE & DCGI APPROVED 140 VVIR PACEMAKER PERMANENT PACEMAKERS WITH ALL LEADS AND ACCESSORIES With out Life time Warranty., US FDA/CE & DCGI APPROVED 141 VVIR PACEMAKER Digital multi-programmable pacemaker.Mode: single chamber: VVIR/AAIR. With beat to beat auto capture and proven longevity of >9.5 years with 100% pacing of RA/RV @2.5Volts. Digital high sampling rate of P/R wave and automated ventricular rate stabilization during AF. With 6F compatible passive-fixation tined lead or screw in lead & lead introducer & dual rate responsive sensors With Life Time Warranty., US FDA/CE & DCGI APPROVED 142 Group G-2 143 VDD/VDDR PACEMAKER PERMANENT PACEMAKERS WITH ALL LEADS AND ACCESSORIES With Life time warranty., US FDA/CE & DCGI APPROVED 144 Group G-3 145 DDDR PACEMAKER PERMANENT PACEMAKERS WITH ALL LEADS AND ACCESSORIES With Life Time Warranty., US FDA/CE & DCGI APPROVED 146 DDDR PACEMAKER PERMANENT PACEMAKERS WITH ALL LEADS AND ACCESSORIES With Limited Warranty., US FDA/CE & DCGI APPROVED 147 DDDR PACEMAKER Digital multi-programmable pacemaker Mode: Dual chamber: DDDR. With features of automatic threshold check, auto adjusting of AV delay (extendable upto 400 ms), and automatic intrinsic activity search. With beat to beat auto capture and proven longevity of >10 years with 100% pacing of RA & RV at 2.5 Volts . With 6F compatible passive-fixation tined leads or screw in leads & lead introducers & dual rate responsive sensors With Life Time Warranty., US FDA/CE & DCGI APPROVED 148 Group G-4 149 AICD SINGLE CHAMBER PACEMAKER WITH ALL LEADS, ICD WITH ALL LEADS AND ALL ACCESSORIES US FDA/CE & DCGI APPROVED 150 AICD DUAL CHAMBER PACEMAKER WITH ALL LEADS, ICD WITH ALL LEADS AND ALL ACCESSORIES US FDA/CE & DCGI APPROVED 151 Group G-5 152 BIVENTRICULAR PACEMAKER WITH ALL ACCESSORIES AND LEADS BIVENTRICULAR PACEMAKER WITH ATRIAL, RV, LV LEADS AND ALL ACCESSORIES REQUIRED DURING IMLANTATION US FDA/CE & DCGI APPROVED 153 Group G-6 154 BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, LV LEADS AND ALL ACCESSORIES REQUIRED DURING IMLANTATION., US FDA/CE & DCGI APPROVED 155 Group G-7 nALL TYPE OF PERMANENT PACEMAKERS (GENERATOR ONLY) WITHOUT LEAD 156 BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITHOUT LEAD., US FDA/CE & DCGI APPROVED 157 BIVENTRICULAR PACEMAKER (CRT) WITHOUT LEAD., US FDA/CE & DCGI APPROVED 158 AICD DUAL CHAMBER PACEMAKER WITHOUT LEAD., US FDA/CE & DCGI APPROVED 159 AICD SINGLE CHAMBER PACEMAKER WITHOUT LEAD., US FDA/CE & DCGI APPROVED 160 DDDR PERMANENT PACEMAKERS WITHOUT LEAD., US FDA/CE & DCGI APPROVED 161 VDD/VDDR PERMANENT PACEMAKERS WITHOUT LEADS., US FDA/CE & DCGI APPROVED 162 DDD PERMANENT PACEMAKERS WITHOUT LEAD., US FDA/CE & DCGI APPROVED 163 VVI PERMANENT PACEMAKERS WITHOUT LEAD., US FDA/CE & DCGI APPROVED 164 VVIR PERMANENT PACEMAKERS WITHOUT LEADS., US FDA/CE & DCGI APPROVED 165 Group G-8 nALL TYPE OF LEADS FOR PERMANENT PACEMAKERS (WITHOUT GENERATOR) 166 ATRIAL LEAD & ALL ACCESSORIES FOR BIVENTRICULAR PACEMAKER (CRT), US FDA/CE & DCGI APPROVED 167 RV LEAD ALL & ACCESSORIES FOR BIVENTRICULAR PACEMAKER (CRT), US FDA/CE & DCGI APPROVED 168 LV LEAD ALL & ACCESSORIES FOR BIVENTRICULAR PACEMAKER (CRT), US FDA/CE & DCGI APPROVED 169 ATRIAL LEAD FOR BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ALL ACCESSORIES REQUIRED DURING IMLANTATION US FDA/CE & DCGI APPROVED 170 RV LEAD FOR BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ALL ACCESSORIES REQUIRED DURING IMLANTATION US FDA/CE & DCGI APPROVED 171 LV LEAD FOR BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ALL ACCESSORIES REQUIRED DURING IMLANTATION US FDA/CE & DCGI APPROVED 172 RV LEAD FOR AICD SINGLE CHAMBER, US FDA/CE & DCGI APPROVED 173 PACING LEADS FOR AICD DUAL CHAMBER, US FDA/CE & DCGI APPROVED 174 ATRIAL LEAD PACING LEAD FOR DDDR PERMANENT PACEMAKERS US FDA/CE & DCGI APPROVED 175 VENTRICULAR LEAD PACING LEAD FOR DDDR PERMANENT PACEMAKERS US FDA/CE & DCGI APPROVED 176 ATRIAL LEAD PACING LEAD FOR DDDPERMANENT PACEMAKERS US FDA/CE & DCGI APPROVED 177 VENTRICULAR LEAD PACING LEAD FOR DDDPERMANENT PACEMAKERS US FDA/CE & DCGI APPROVED 178 PACING LEADS FOR VDD/VDDR PACEMAKERS US FDA/CE & DCGI APPROVED 179 PACING LEADS FOR VVI/VVIR PACEMAKERS US FDA/CE & DCGI APPROVED 180 EPICARDIAL LEAD FOR PACEMAKERS US FDA/CE & DCGI APPROVED 181 Group H-1 182 TEMPORARY PACING LEADS - US FDA/CE & DCGI APPROVED 183 TEMPORARY PACING LEADS: BALLOON FLOATABLE – US FDA/CE & DCGI APPROVED 184 TEMPORARY PACING LEADS With Stylet - US FDA/CE & DCGI APPROVED 185 Group H-2 186 Lead extraction system of different variety 187 Group H-3nDIAGNOSTIC EP CATHETERS Bipoles, Catheter, French, Catheter, Curve, Electrode, Configuration, Fiexd/Deflectable (37.01 to 37.14) nnEP CATHETERS FOR PEDIATRIC EP WORK (37.15 to 37.17)n nWOVEN EP DIAGNOSTIC CATHETERSn(woven material with braided conducting wire, ensuring prolonged stability) (37.18 to 37.26) nnWOVEN PEDIATRIC EP CATHETERSn(woven material with braided conducting wire, ensuring prolonged stability) (37.27 to 37.29) 188 Quadripolar, 6, Any, Any, Fixed 189 Quadripolar, 5-7, Mullins, 2-5-2-5, Fixed 190 Quadripolar, 5-7, Josephson, 2-5-2-5, Fixed 191 Quadripolar, 5-7, His Bundle, 2-5-2-5, Fixed 192 Quadripolar, 5-7, Mullins, 4-2-4-2, Fixed 193 Quadripolar, 6, Mullins, 2-5-2-5, Deflectable 194 Tripolar, 5-7, Any, Any, Fixed 195 Tripolar, 6, Any, 2-5-2-5, Fixed 196 Hexapolar, 6, Any, 2-5-2-5 tip, 2-5-2, 20-30 cm ,Prox bipolem, For Unipolar signals 197 Decapolar, 5-7, Any, Any, Fixed 198 Decapolar, 6, Any, 2-10-2, Fixed 199 Decapolar, 5-7, Any, 2-5-2, Fixed 200 Decapolar, 5-7, Any, 2-5-2, Fixed 201 Decapolar, 5-7, Any, 2-2-2-10-2-2-2-10-2, Deflectable 202 Quadripolar, 4, Josephson, 2-5-2-5, Fixed 203 Decapolar, 4, Any, 2-5-2-5, Fixed 204 Decapolar, 4, Any, 2-2-2-2-2, Deflectable 205 Quadripolar, 6, Any, Any, Fixed 206 Quadripolar, 5-7, Mullins, 2-5-2-5, Fixed 207 Quadripolar, 5-7, Josephson, 2-5-2-5, Fixed 208 Quadripolar, 5-7, Mullins, 4-2-4-2, Fixed 209 Hexapolar, 6, Any, 2-5-2-5 tip, 2-5-2, 20 cm Prox, Fixed 210 Decapolar, 6, Any, 2-10-2, Fixed 211 Decapolar, 5-7, Any, 2-5-2, Fixed 212 Decapolar, 5-7, Any, 2-2-2, Fixed 213 Decapolar, 5-7, Any, 2-2-2-10-2-2- 2-10-2, Deflectable 214 Quadripolar, 4, Josephson, 2-5-2-5, Fixed 215 Quadripolar, 4, Mullins, 2-5-2-5, Fixed 216 Decapolar, 4, Any, 2-2-2-2-2, Deflectable 217 Group H-4 nSPECIAL CATHETERS FOR AF, FLUTTER ETC - US FDA/CE & DCGI APPROVED n(quote all diameters, French size, different electrodes like Platinum, Paladium or stainless steel) 218 DEFLECT. DECADUAPOLAR (20 poles) FOR A FLUTTER ---- all diameters 219 DEFLECTABLE DECAPOLAR (10) (PULM. VEIN) --- all diameters 220 DEFECTABLE DECADUAPOLAR (20) (PULM. VEIN) --- all diameters 221 2F MULTIPOLAR (> TEN electrodes) for mapping through coronary vasculature 222 BASKET CATHETER WITH ACCESSORY 223 CRISTA CATHETER WITH ACCESSORY 224 OTHER SPECIAL EP CATHETERS 225 PACING CATHETER WITH ANGIOGROPHIC CAPABILITY 226 PEDIATRIC USE : ALL THE ABOVE CATHETERS, SHEATHS etc FOR PEDIATRIC USE. 227 Group H-5 228 Pentapolar Diagnostic Catheter – Fixed Curve, Catheter material – Woven, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval – - US FDA/CE & DCGI APPROVED Size(Fr)-6, Electrode Spacing(mm)-5,5,5,282mm,n5,5,5,152mm, Curve-Josephson 229 Octapolar Diagnostic Catheter – Fixed Curve, Catheter material – Woven, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval – US FDA/CE & DCGI APPROVED Size(Fr)-6, Electrode Spacing(mm)-5 mm, 1 mm, 1,10,1 mm, Curve-Cournand 230 16 Pole Diagnostic Catheter – Fixed Curve, Catheter material – Woven, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval – US FDA/CE & DCGI APPROVED Size(Fr)-6, Electrode Spacing(mm)- 1-5-1 mm, 1-5-1 mm, Curve-Damato,, nSmall 60 231 20 Pole Diagnostic Catheter – Fixed Curve, Catheter material – Woven, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval– US FDA/CE & DCGI APPROVED Size(Fr)-6, Electrode Spacing(mm)- 5,5,5,5,5,5,5,5n5,5,5,5,5,5,5,5,5n5,5,5 mm, Curve-K 232 24 Pole Diagnostic Catheter – Fixed Curve, Catheter material – Woven, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval – US FDA/CE & DCGI APPROVED Size(Fr)-6, Electrode Spacing(mm)-24-2 mm, 2-7-2 mm, 2-9-2 mm, Curve-K 233 Bi-Directional Steerable Catheters, Handle- Thumb Wheel or Push Pull, Automatic Curve Lock Mechanism, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval – US FDA/CE & DCGI APPROVED Size(Fr)-, Electrode Spacing(mm)-, Curve-Small,nLarge 4.0, 234 Atrial Mapping Catheters, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval – US FDA/CE & DCGI APPROVED Size(Fr)-7 Fr, Electrode Spacing(mm)-All, Curve-All 235 Dual Curve RF Ablation Catheter, Bi-Directional Steerable, Electrode – Stainless Steel, Platinum, Paladium, Quality Approval – US FDA/CE & DCGI APPROVED Size(Fr)-7.8 Fr, Electrode Spacing(mm)-2-5-2 mm, Curve-Medium Large, Extra Large 236 Group H-6nABLATION CATHETERS - US FDA/CE & DCGI APPROVED Type, Tip Size, Diameter, Curves/Reach, Comments 237 Regular, 4 mm, 6-8F, All (Equivalent to A-F, J, K, 270) 238 Regular, 8 mm, 6-8F, All (Large, Extended Reach), Dual Sensor 239 Regular, 3.5 mm, Any, All 240 Regular, 2 mm, Any, All 241 Regular, 4 mm, 5F, All, Pediatric Use 242 Cool Tip (Closed), Any, 7-9F, All 243 Irrigated Tip (Open), Any, 7-9F, All 244 Others, Any, Any, All, All 4 Active, Movable Tip Electrode, 10 mm ETC 245 Bidirectional, Any, Any, All 246 Omnidirexnl, Any, Any, All 247 Group H-7nCATHETERS, CABLES, ACCESSORIES FOR ENDOCARDIAL SOLUTIONS (ESI) ACCESSORIES – US FDA/CE & DCGI APPROVED 248 REUSABLE DEFIBRILLATION/ TRANSCUTANEOUS PACING PATCHES (suitable for Equipment in Cath lab, CT2, CT3, CT6) 249 DISPOSABLE DEFIBRILLATION / TRANSCUTANEOUS PACING PATCHES (suitable for Equipment in Cath lab, CT2, CT3, CT6) 250 DEFIBRILLATION/TRANSCUTANEOUS PACING PATCHES for USE IN INFANTS AND CHILDREN 251 CRYO CATHETERS (AND ACCESSORIES)FOR ABLATION OF ARRHYTHMIAS IN CHILDREN AND ADULTS 252 INTRACARDIAC ULTRASOUND/ ECHO CATHETER FOR GUIDING RFA COMPATIBLE WITH THE EXISTING ECHO MACHINE AT PBM HOSPITAL, Bikaner (QUOTE ALL PRICES OF THE CATHETERS and ACCESSORIES) 253 DISPOSABLE ELECTROCAUTERY PATCHES FOR RFA 254 REUSABLE ELECTROCAUTERY PATCHES FOR RFA 255 Group H-8nCONSUMABLES FOR 3D MAPPING SYSTEM (EP) 256 Velocity Navx Patch 257 Velocity array Catheter 258 Group H-9 259 Sheaths Used In EP Study and RFA, SRO SL, AZULIXn 260 Group InCORONARY ANGIOGRAPHY (ITEMS USED IN CATH LAB) 261 ANGIO GUIDEWIRE 0.035 – J/ 0.032 J-tip 150 Cm Radifocus Terumo 262 ANGIO GUIDEWIRE 0.035 – J/ 0.032 J-tip 150 Cm Radifocus Translumina or Equivalent 263 ANGIO. CATH. AL1/ AL2/ AL3 – 5F, 6F 264 ANGIO. CATH. AR1/ AR2/ AR3 – 5F, 6F 265 ANGIO. CATH. JL -3.5/4.0/4.5/5.0 (5F & 6F) 266 ANGIO. CATH. JR. 3.5/4.0 (5F & 6F) 267 ANGIO. CATH. PIGTAIL 4F/ 5F/ 6F 268 IMA - 6F/ 7F 269 MULTIPURPOSE 6F, 7F 270 PEADIATRIC INPUT SHEATH 4F/ 5F 271 TERUMO RADIAL SHEATH 5F/ 6F 272 Translumina RADIAL SHEATH 5F/ 6F or Equivalent 273 TIGER 5F/ 6F CATHETER Terumo 274 TIGER 5F/ 6F CATHETER Translumina or Equivalent 275 DYE (NON-IONIC CONTRAST AGENT 50ML It should be US FDA/CE & DCGI APPROVED IOhexol as salt name with 350 mg/ml concentration 276 DYE (NON-IONIC CONTRAST AGENT 100ML It should be US FDA/CE & DCGI APPROVED IOhexol as salt name with 350 mg/ml concentration 277 DYE (NON-IONIC CONTRAST AGENT 200ML It should be US FDA/CE & DCGI APPROVED IOhexol as salt name with 350 mg/ml concentration 278 Iodixanol as a salt name, 320mg/ml With Plastic Bottle, 50mll pack, It should Polypropylene with hanger for product packing., It should be US FDA/CE & DCGI APPROVED 279 Iodixanol as a salt name, 320mg/ml With Plastic Bottle, 100ml pack 280 FEMORAL SHEATH 5F/6F/7F/8F/9F 281 Unilock syringe 10 ml 282 IV Cannula (Rom sons 18,20,22 g) 283 DISPOSABLE ECG ELECTRODES FOR ADULTS - US FDA/CE & DCGI APPROVED 284 CD – R MEDIA with atleast 700 MB storage and atleast 52x recordable speed 285 Pressure Monitoring line 200cm 286 Manifold ( Two Port ) 287 High Pressure line 288 Group J-1nItems for BMV Procedutre 289 Brocken Brough Needle (Transeptal ) 290 L.A. Wire, Stylet, Ruler,Syringe, Streching Tube ( Balloon Kit ) 291 Baloon Size 20-30 MM Innoue 292 Baloon Size 20-30 MM Accura 293 Baloon Size 20-30 MM SYM/ Equivalent 294 Mullen Sheath 295 Baloon Shaper 296 Septal Dilator 297 Exchange Length Terumo Wire 298 Tyshak Balloon (9-12) 299 Tyshak Balloon Compatible Extra Stiff wire (021 & 025) 300 Valver Balloon 301 Group J-2 302 Balloon for Pulmonary Valve Dilation 303 Group J-3 304 IVUS Catheter Compatible with System in Cath lab of PBM Hospital bikaner (BOSTON SCIENTIFIC) 305 FFR Catheter Compatible with St. Jude system 306 ROTA Advancer catheter 307 ROTA Burr (All Size) 308 ROTA Wire

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Jul-2020 Corrigendum for BOQ BOQ 15-07-2020
2 14-Jul-2020 Corrigendum for categorization of Items estimated cost and Bid Security and modification in items specification and updation in Bid Submission End Date, Bid Opening Date Date 30-07-2020

Key Value

Document Fees
INR 1000 /-
EMD
INR 1000000.0 /-
Tender Value
INR 5 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail