| 1 | 1 | Manning , operation & Maintenance of electric driven mono block /cenrtrifugal pump set of capacity KW/10 HP- 02 Nos, , filter feed pump 2Nos,Chlorine Dosing pump, and 500 Ltrs per hours RO Plant complete (RO feed pump, Dosing pumps, High Pressure pumps,RO water trasfer pumps CIP Pumps), Multigrade Pressure filter ,Activated Carbon Filter ,Antiscalant dosing system ,Post pH correction dosing system Complete set of RO module comprising of 4 Nos of membarnes , intruments for RO plant complete,Chemical cleaning system etc) including periodical maintenance of starter, panel board motor & pumps etc, valve operation for giving water supply, cleaning of installation and nearby area complete at Mandakini complex Dehradun all as directed in two shifts of eight hours per day continuous duration inclduing Sunday and gazetted holidays incluidng daily check and maintenacne/cleaninag weekly/monthly/quarterly and half yearly with one motor pump attendant/operation in each shift all as specified :- \nShift one - 0400 hrs to 1200 hrs-01 No (Skilled)\nShift two - 1200 hrs to 2000 hrs -01 No (Skilled)\n Note : (a )The motor pump attendant/operator shall be Govt ITI qualified having 04 Years experience in concerned field. \n (b) Log book for daily record maintained for pumps, RO plant ,dosing plants etc (c ) Monthly visit of Technical Person to Access the running health of & RO Plant (d ) Maintenning of ph meter and chalorine contenance in water all as dirceted and specified by Eng in charge. \n(e)All minor repair shall be included in quoted in rate \n(f) Day to maintenance record tobe maintained at MRS and produced to Engr-in-Charge when required. \n(g) Contrctor will take willingness from operator before appointment. \n(h) Contractor will do the insurance of all the operators. | | 11 | Per Month |
|---|
| 2 | 2 | Manning, opration & maintenance of 11 KV main sub station including running of DG Set if electric supply failure from UPCL round the clock including sunday & Holiday for repair/rectification of fault developed in LT, OH/ UG line 11 KV in main receiving station compoud and LT OH/ UG line in 44 DAD Mandakini complex Dehradun PCDA (AF)Rajpur Campous , all electric system and equipment as listed in Appendix \"A\" including to upkeep the electrical installations, operation and carrying out daily weekly, monthly and half preventive maitenance as per schedule \"A\" specification, particulars, specification, Indian electicity rules, Engineering practices and as per manufaturer guide lines including keeping proper record etc, complete with the following qualified techincal staff alongwith proper tools/safety devices, own conveyance :-\n(i) Day shift from 0600 Hrs to 1400 Hrs (a) Electrician - 01 No. (Skilled)\n(ii) Evening Shift from 1400 hrs to 2200 Hrs (a) Electrician -01 No. (Skilled)all be\n(iii) Night Shift from 2200 Hrs to 0600 Hrs (a) Electrician- 01 No. (Skilled)\n(iv)Shift one - 0900 hrs to 1700 hrs - 01 ( semi skilled ) \nNotes :-(a) The Electrician shall be Govt ITI qualified having 04 Years experience in concerned field. (b) Diesel required for running of DG set shall be provided by the MES free of cost. (c) Rates quoted shall be including the following :-\n(i) Minor repair to un interrupted electricity and maintenance of MRS yard with proper tools, cleaning of existing insulaors all type by soft cotton cloth after proper shutdown by In-Charge of electric supply.\n(ii)Prevntive maintenance of all plants and equipment as mentiond in particular specifications. \n(iii) Electricity required shall be made available to the contractor free of cost by the department. \n(iv) Spare parts required for maintenance shall be measured & paid separtely. \n(v) One mobile phone will be kept in MRS for proper communication round the clock. \n(vi) Day to maintenance record to be maintained at pump house and produced to Engr-in-Charge when required. \n(vii) Contrctor will take willingness from operator before appointment. \n(viii) Contractor will do the insurance of all the operators. | | 11 | Per Month |
|---|
| 3 | 3 | Repair and maintenance of day to day internal and external water supply complaints at 44 DAD Mandakini complex Dehradun complete all as specified and directed in one shift from 0900 hrs to 1700 hrs incl sunday and holidays by providing the following: (a) Pipe fitter-01 No (Semi-Skilled)\nNote :- Stores required for replacement/ repair shall be measured and paid separately and contractor shall provide T&P as required without any extra cost to department. | | 11 | Per month |
|---|
| 4 | 4 | Manning and maintenance of Lawns, gardens, trees and plants of PCDA (AF) Complex and 44 DAD Accn Mandakini complex Dehradun including digging of pits/holes, dressing of plants/grass, watering of area complete with one shifts of eight hours per day continuous duration exclduing Sunday all as specified and directed by Eng-in-Charge.\nShift one - 0800 hrs to 1600 hrs-01 No (Skilled)\n | | 11 | Per Month |
|---|
| 5 | 5 | Repair and receplcement of LED batten with aluminium housing 20 Watt complete all as specified and directed.Make cat No LXEXACP7IN1W020 of Havells & equivalent Cromption /C&S | | 100 | Each |
|---|
| 6 | 6 | Repair and receplcement of LED unique recess cum surface panel 6 Watt complete all as specified and directed.Make Cat part No LHEAABP5IL1W006 ofHavells & Equivalent Cromption /C&S complete all as specified and as directed. | | 30 | Each |
|---|
| 7 | 7 | Supply and fixing modular switch single pole, one-way 5/6 Amps, 240 Volts AC complete all as specified and directed.Legrand / Anchar , complete all as specified and as directed. | | 100 | Each |
|---|
| 8 | 8 | Supply and fixing modular switch one-way 16 Amp, 240 Volts AC complete all as specified and directed. | | 20 | Each |
|---|
| 9 | 9 | Supply and fixing modular socket out let 5 pin 6 Amps flush type all as specified. | | 30 | Each |
|---|
| 10 | 10 | Supply and fixing modular socket out let 5/6pin 5 Amp and 15 Amp flush type (multi) suitable for 240 Volt AC all as specified. | | 30 | Each |
|---|
| 11 | 11 | M&L modular fan regulator step type 230 volts double module suitable for 1200\1400mm sweep size. | | 30 | Each |
|---|
| 12 | 12 | Supply and fixing bell ding dong AC 230/240 Volts all as specified. | | 5 | Each |
|---|
| 13 | 13 | Repair and recplacement of LED 150 watts bulb in liou of existing MH lamp including all nacessray arrangement as require complete all as specified and directed | | 20 | Each |
|---|
| 14 | 14 | Supply only capacitor 2.5 mfd for fan. Make – Havells/Universal/Asian or equivalant , complete all as specified and as directed. | | 50 | Nos |
|---|
| 15 | 15 | Supply and fixing LED bulb 9 Watt complete all as specified and as directed. | | 20 | Nos |
|---|
| 16 | 16 | Supply and fixing MCB 5 to 32 Amp 'C' series 10 KA repturing capacity complete all as specified. | | 20 | Each |
|---|
| 17 | 17 | Supply and fixing MCB isolator SPN 40 Amp 240 V AC 10 KA repturing capacity all as specified. | | 10 | Each |
|---|
| 18 | 18 | Supply and fixing MCB isolator TP 63 Amps 240 V 10 KA repturing capacity all as specified. | | 4 | Each |
|---|
| 19 | 19 | Supply and fixing MCCB four pole 63 Amps 415 V 16 KA repturing capacity all as specified. | | 2 | Each |
|---|
| 20 | 20 | Supply and fixing MCB isolator 4 pole 63 Amps 420 V 10 KA repturing capacity all as specified. | | 5 | Each |
|---|
| 21 | 21 | S&F in replacement exhaust fan /fresh air fan 230/300 mm sweep plastic body complete all as specified and directed by Eng.-in-charge | | 5 | Each |
|---|
| 22 | 22 | Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FR ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR ) as earth wire and wire connected with main earth dolly including cutting chasing and making good disturbed portion all as specified and directed \n | | 50 | RM |
|---|
| 23 | 23 | Repair and receplcement of driver suitable for 70/75 watt led light, complete all as specified and as directed. | | 3 | Each |
|---|
| 24 | 24 | Repair and receplcement of driver suitable for 40 watt led light, complete all as specified and as directed. | | 5 | Each |
|---|
| 25 | 25 | Repair and receplcement of Surge protection Divices 10KV for 40 watt led light, complete all as specified and as directed. | | 5 | Each |
|---|
| 26 | 26 | Cleaning of under ground sump 75000 Ltr capacity off sizes (wall and floor scrubbing with wire brush and cleaning by brooming removing all sludge/mud, vegetation grouwth(if any) washing the sump with bleaching powder (as approved by Engr-in-Charge) to store potable water after applying two coats of lime wash internally all as specified and and directed by Engr-in-Charge. | | 2 | Each Job |
|---|
| 27 | 27 | Cleaning of treated water under ground sump 45000 Ltr capacity off sizes (wall and floor scrubbing with wire brush and cleaning by brooming removing all sludge/mud, vegetation grouwth(if any) washing the sump with bleaching powder (as approved by Engr-in-Charge) to store potable water after applying two coats of lime wash internally all as specified and and directed by Engr-in-Charge. | | 2 | Each Job |
|---|
| 28 | 28 | Cleaning of over head PVC/RCC tank of 1000 ltrs capacity.(wall and floor scrubbing with wire brush and cleaning by brooming removing all sludge/mud, vegetation grouwth(if any) washing the sump with bleaching powder (as approved by Engr-in-Charge) all as specified and and directed by Engr-in-Charge | | 2 | Each Job |
|---|
| 29 | 29 | Supply and fix LED security light 70 Watt with bracket, clamps and fixing arrangements complete all as specified and directed. | | 2 | Each |
|---|
| 30 | 30 | M & L for gun metal gate valve iron wheel head screwed both end from iron pipe of size 25 mm dia | | 4 | Each |
|---|
| 31 | 31 | M & L for gun metal gate valve iron wheel head screwed both end from iron pipe of size 40 mm dia | | 2 | Each |
|---|
| 32 | 32 | Supply and fix bib taps chrome plated cast copper alloy with crutch or butterfly handle of 15 mm bore dia | | 5 | Each |
|---|
| 33 | 33 | Supply and fix PVC connection 15 mm dia,600 mm long for hot water. | | 10 | Nos |
|---|
| 34 | 34 | Supply and fix in replacement hot water apparatus 25 Ltr cap complete all as specified and directed. | | 1 | Nos |
|---|
| 35 | 35 | Supply and fix Heating element 2 KW capacity, straight, triangular type for Geysers . | | 20 | Nos |
|---|
| 36 | 36 | Supply and fix Star Delta starter 10 HP for centrifual pump Complete all as specified and directed | | 1 | Each |
|---|
| 37 | 37 | Supply and consuming of Antiscalant , complete all as specified and as directed. | | 100 | Kg |
|---|
| 38 | 38 | Supply and consuming of Sodium Hypochlorite, complete all as specified and as directed. | | 200 | Kg |
|---|
| 39 | 39 | Supply and consuming of Soda Ash (Ph correction booster ), complete all as specified and as directed. | | 50 | Kg |
|---|
| 40 | 40 | Supply and consuming of Citric Acid, complete all as specified and as directed. | | 25 | Kg |
|---|
| 41 | 41 | Supply and consuming of SBMS dosing, complete all as specified and as directed. | | 50 | Kg |
|---|
| 42 | 42 | Supply and consuming of Acid dosing, complete all as specified and as directed. | | 100 | Kg |
|---|
| 43 | 43 | Supply and replace catridge, complete all as specified and as directed. | | 24 | Nos |
|---|
| 44 | 44 | Repair and maintenance of external and internal Water supply pipe line including plumbring work as required at site including necessary fittings and fixtures as directded by Engr-in-Charge for the following sizes :-\n | | | |
|---|
| 45 | 44.1 | 20 mm | | 20 | RM |
|---|
| 46 | 44.2 | 25 mm | | 20 | RM |
|---|
| 47 | 44.3 | 40 mm | | 20 | RM |
|---|
| 48 | 45 | M&L for Gun metal globe or Gate valve with iron wheel head, screwed both ends for iron pipe of the following sizes:- | | | |
|---|
| 49 | 45.1 | 20mm dia | | 8 | Each |
|---|
| 50 | 45.2 | 50mm dia | | 2 | Each |
|---|
| 51 | 46 | M&L for PVC valve suitable for PVC pipe of the following sizes:- | | | |
|---|
| 52 | 46.1 | 20mm dia | | 2 | Each |
|---|
| 53 | 46.2 | 40mm dia | | 2 | Each |
|---|
| 54 | 46.3 | 50mm dia | | 2 | Each |
|---|
| 55 | 47 | Supply and laying in trenches/wall/floors GI tube medium grade including all requested fittings complete all as specified and directed of following sizes:- | | | |
|---|
| 56 | 47.1 | 50 mm dia bore | | 12 | RM |
|---|
| 57 | 47.2 | 40 mm dia bore | | 12 | RM |
|---|
| 58 | 47.3 | 25 mm dia bore | | 20 | RM |
|---|
| 59 | 47.4 | 20 mm dia bore | | 20 | RM |
|---|
| 60 | 48 | Supply and fix in repair CI foot valve 80 mm dia for fire fighting system as per sample complete all as specified and directed. | | 1 | Each |
|---|
| 61 | 49 | Supply and fix in repair CI foot valve 40 mm dia for fire fighting system as per sample complete all as specified and directed. | | 1 | Each |
|---|
| 62 | 50 | Serviceing of complete RO plant including minor repair, oiling and gresing of all motors & pumps all as directed by Eng In Charge | | 2 | Job |
|---|