| 1 | 1 | Tightening of GI J or L hooks in AC sheet/ GI sheet roofing including removal of clotted bitumastic compound wherever necessary, arresting roof leakage by providing and applying bitumastic compound of approved brand and bitumen/ GI washers and other roof leaking arresting materials wherever required over J bolts including providing safety measures for the labourers to work at higher elevation viz., ropes etc., insurance coverage for labourers and hiring of required T&P complete. | | 12450 | Each |
|---|
| 2 | 2 | Tightening of EPDM screws in GI profile sheet roofing including fixing of missing screws, arresting roof leakage by providing and applying sealant compound/ GI washers and other roof leaking arresting materials wherever required over EPDM screws including providing safety measures for the labourers to work at higher elevation viz., ropes etc., insurance coverage for labourers and hiring of required T&P etc complete. | | 900 | Each |
|---|
| 3 | 3 | Providing and laying tarfelt/ plastic felt/ bitumen felt sheet with Shalibond CS over AC sheet roofing wherever necessary including providing and applying Shalibond CS & Bitumen felt :Type 3 grade 1 of approved brand wherever required over roof including providing necessary safety measures for the labourers to work at higher elevation, ropes etc., insurance coverage for labourers and hiring of requiring T&P complete. | | 216 | Sqm |
|---|
| 4 | 4 | Cleaning of storm water drains in all depths and width including removal of debris/ rubbish and disposal of the same in all leads and lifts, filling in low lying areas and levelling complete in the depot premesis as directed by the Engineer-in-Charge and the drain to be kept clean during the period of monsoon. | | 1540 | Meter |
|---|
| 5 | 5 | Cleaning of service water drains around godown in all depths and width including removal of debris/ rubbish and disposal of the same in all leads and lifts, filling in low lying areas and levelling complete in the depot premesis as directed by the Engineer-in-Charge and the drain to be kept clean during the period of monsoon. | | 1815 | Meter |
|---|
| 6 | 6 | Servicing to the rolling shutters including cleaning the side guides, springs and shaft etc., with kerosene oil, providing and applying freash grease, applying tension to the springs, replacing damaged parts and welding locking plates, stoppers etc., wherever necessary etc. complete as directed by the Engineer-in-charge. (Rolling shutter parts like lathes, springs etc. will be supplied at free of cost) | | 116 | Each |
|---|
| 7 | 7 | Supplying rolling shutter springs of 27.5 cm long wire spring grade no.2 for rolling shutters etc. complete as directed by Engineer-in-charge. | | 40 | Each |
|---|
| 8 | 8 | Supplying of 80x1.25mm machine rolled lathes/ bottom plates arrangement for inside and outside locking with push and pull operation etc.complete of required thickness etc. for rolling shutters as directed by Engineer-in-charge. | | 25.9 | Sqm |
|---|
| 9 | 9 | Providing and fixing ball bearing for rolling shutters. | | 40 | Each |
|---|
| 10 | 10 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover\n | | 30 | Sqm |
|---|
| 11 | 11 | Providing and replacing 6 mm thick corrugated AC sheets in roofing including dismantling broken AC sheet upto any pitch and fixing with polymer coated J or L hooks bolts and nuts 8 mm dia GI plain and bitumen washers etc. complete as per directions of Engineer-in-charge (excluding the cost of purlins, rafters and trusses) including cutting sheets to size and shape wherever required. | | 180 | Sqm |
|---|
| 12 | 12 | Providing and fixing ridges and hips in asbestos cement sheets roofing. Close fitting adjustable ridges. | | 36 | Meter |
|---|
| 13 | 13 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) | | 10 | Metre |
|---|
| 14 | 14 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) \n | | 75 | Sqm |
|---|
| 15 | 15 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) | | 12 | Sqm |
|---|
| 16 | 16 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. | | 13 | Sqm |
|---|
| 17 | 17 | Supply of services of semi-skilled labour like carpenter, sewer man, plumber etc. on daily rate basis for day-to-day maintenance atleast weekly once as per direction of Engineer-in-charge. | | 5 | Day |
|---|
| 18 | 18 | Supply of services of labour like beldar, coolie, helper etc. on daily rate basis for day-to-day maintenance atleast weekly once as per direction of Engineer-in-charge. | | 8 | Day |
|---|
| 19 | 19 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | | 100 | Cum |
|---|
| 20 | 20 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore | | 5 | Each |
|---|
| 21 | 21 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore | | 2 | Each |
|---|
| 22 | 22 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia Pipes. | | 50 | Meter |
|---|
| 23 | 23 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes. | | 50 | Meter |
|---|
| 24 | 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work | | 920 | Sqm |
|---|
| 25 | 25 | Lettering with black Japan paint of approved brand and manufacture. | | 12420 | per letter\nper cm\nheight |
|---|
| 26 | 26 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | | 430 | Kg |
|---|
| 27 | 27 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Door chowkhats | | 50 | Each |
|---|