Sales : +91-777 804 8217
| Work Name: Construction of Multipurpose Cyclone Shelter at Kasaba,Kozhikode; National Cyclone Risk Mitigation Project (NCRMP - PHASE II) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | APPENDIX - A - CONSTRUCTION OF BUILDING | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.01 | 2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. | BI01010001010000000000000515BI0100001114 | 1500 | sqm |
| 3 | 1.02 | 2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock | BI01010001010000000000000515BI0100001115 | 581.056 | cum |
| 4 | 1.03 | 2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock | BI01010001010000000000000515BI0100001116 | 84.939 | cum |
| 5 | 1.04 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001117 | 96.777 | cum |
| 6 | 1.05 | od10377/2020_2021 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).\r20.2.5 | BI01010001010000000000000515BI0100001118 | 2001 | metre |
| 7 | 1.06 | 15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | BI01010001010000000000000515BI0100001119 | 31.2 | cum |
| 8 | 1.07 | 20.6.2.1 : Single pile above 50 tonne and upto 100 tonne capacityInitial test | BI01010001010000000000000515BI0100001120 | 1 | per test |
| 9 | 1.08 | 20.6.2.2 : Single pile above 50 tonne and upto 100 tonne capacityRoutine test | BI01010001010000000000000515BI0100001121 | 2 | per test |
| 10 | 1.09 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001122 | 373.962 | sqm |
| 11 | 1.1 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | BI01010001010000000000000515BI0100001123 | 256.25 | sqm |
| 12 | 1.11 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | BI01010001010000000000000515BI0100001124 | 1355.98 | sqm |
| 13 | 1.12 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | BI01010001010000000000000515BI0100001125 | 659.688 | sqm |
| 14 | 1.13 | 5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) | BI01010001010000000000000515BI0100001126 | 112.32 | sqm |
| 15 | 1.14 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001127 | 1123.34 | sqm |
| 16 | 1.15 | 5.9.4 : Centering and shuttering including strutting, etc. and removal of form for:Shelves (Cast in situ) | BI01010001010000000000000515BI0100001128 | 64.998 | sqm |
| 17 | 1.16 | 5.9.16.1 : Edges of slabs and breaks in floors and wallsUnder 20 cm wide | BI01010001010000000000000515BI0100001129 | 353.28 | metre |
| 18 | 1.17 | 5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges | BI01010001010000000000000515BI0100001130 | 180.039 | sqm |
| 19 | 1.18 | od10406/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M- 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All work up to plinth level | BI01010001010000000000000515BI0100001131 | 170.044 | cum |
| 20 | 1.19 | od10409/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All work above plinth level upto floor V level | BI01010001010000000000000515BI0100001132 | 371.913 | cum |
| 21 | 1.2 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001133 | 51.223 | cum |
| 22 | 1.21 | 50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge | BI01010001010000000000000515BI0100001134 | 4500 | cum |
| 23 | 1.22 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | BI01010001010000000000000515BI0100001135 | 284.144 | cum |
| 24 | 1.23 | od10464/2020_2021 : Corrosion Resistant Steel Reinforcement for R.C.C work (CRSD\r500 or above) including straightening, cutting, bending, placing in position and binding all complete at all levels.:(Reference code:5.22.6) | BI01010001010000000000000515BI0100001136 | 155156 | kilogram |
| 25 | 1.24 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001137 | 306.271 | cum |
| 26 | 1.25 | od3605/2020_2021 : Laterate masonry with neatly dressed laterate stone of size 35x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.(Modified 50.6.7.1) | BI01010001010000000000000515BI0100001138 | 14.368 | cum |
| 27 | 1.26 | od3576/2020_2021 : Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. (Modified 50.6.7.2) | BI01010001010000000000000515BI0100001139 | 229.323 | cum |
| 28 | 1.27 | od3598/2020_2021 : Laterite masonry with neatly dressed laterite stone of size 35x20x20cm or nearest size in cement mortar 1:6 for super structure above floor two level upto floor five level including all cost of materials, labour charges etc. | BI01010001010000000000000515BI0100001140 | 119.488 | cum |
| 29 | 1.28 | 50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood | BI01010001010000000000000515BI0100001141 | 0.849 | cum |
| 30 | 1.29 | 50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood | BI01010001010000000000000515BI0100001142 | 39.857 | sqm |
| 31 | 1.3 | 50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood | BI01010001010000000000000515BI0100001143 | 21.973 | sqm |
| 32 | 1.31 | 9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001144 | 114 | each |
| 33 | 1.32 | 9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm | BI01010001010000000000000515BI0100001145 | 54 | no |
| 34 | 1.33 | 9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm | BI01010001010000000000000515BI0100001146 | 54 | no |
| 35 | 1.34 | 9.17A.3 : Providing and fixing factory made uPVC white colour casement/casement cum\nfixed glazed windows comprising of uPVC multi-chambered frame, sash and\nmullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2\nmm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of\nappropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction\nhinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8\nmm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut\nand fusion welded at all corners, mullion (if required) shall be also fusion welded\nincluding drilling of holes for fixing hardware's and drainage of water etc. After\nfixing frame the gap between frame and adjacent finished wall shall be filled with\nweather proof silicon sealant over backer rod of required size and of approved\nquality, all complete as per approved drawing & direction of Engineer-in-Charge.\n(Single / double glass panes and silicon sealant shall be paid separately)<br>\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm &mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazingbead of appropriate dimension. ( Area of window upto 2.50 sqm). | BI01010001010000000000000515BI0100001147 | 99.062 | sqm |
| 36 | 1.35 | 9.7.7.1 : Float glass panes4 mm thick glass pane | BI01010001010000000000000515BI0100001148 | 158.29 | sqm |
| 37 | 1.36 | od76976/2019_2020 : Supplying and fixing aluminum sliding doors with powder coated sections of 20 mm series (1.5 mm thick) Three track frame with 92.36 mm x 29.70 mm and shutters with 39 mm x 20 mm shutter interlock and plain for vertical and 41 mm x 20 mm top and bottom sections including rubber beading, 12 mm prelaminated particle board PVC wheel, locks and all cost of materials, labor charges fixing in position etc. complete.<br> | BI01010001010000000000000515BI0100001149 | 4.2 | sqm |
| 38 | 1.37 | 9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding | BI01010001010000000000000515BI0100001150 | 3582.2 | kg |
| 39 | 1.38 | 10.25.2 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001151 | 729 | kg |
| 40 | 1.39 | 9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | BI01010001010000000000000515BI0100001152 | 19 | no |
| 41 | 1.4 | 9.81.1 : Providing and fixing bright finished brass handles with screws etc. complete:125 mm | BI01010001010000000000000515BI0100001153 | 38 | no |
| 42 | 1.41 | 9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | BI01010001010000000000000515BI0100001154 | 19 | no |
| 43 | 1.42 | 50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop | BI01010001010000000000000515BI0100001155 | 20 | no |
| 44 | 1.43 | 9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. | BI01010001010000000000000515BI0100001156 | 4 | no |
| 45 | 1.44 | 10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) | BI01010001010000000000000515BI0100001157 | 2045.86 | kg |
| 46 | 1.45 | od76977/2019_2020 : (Reference code:10.6.1) Supplying and fixing epoxy coated rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.<br>80x1.25 mm M.S. laths with 1.25 mm thick top cover | BI01010001010000000000000515BI0100001158 | 21.601 | sqm |
| 47 | 1.46 | 10.7 : Providing and fixing ball bearing for rolling shutters.Providing and fixing ball bearing for rolling shutters. | BI01010001010000000000000515BI0100001159 | 8 | no |
| 48 | 1.47 | 22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | BI01010001010000000000000515BI0100001160 | 241.687 | sqm |
| 49 | 1.48 | 22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) | BI01010001010000000000000515BI0100001161 | 327.177 | sqm |
| 50 | 1.49 | 9.118.2 : Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001162 | 34.5 | sqm |
| 51 | 1.5 | 9.143 : Providing and fixing factory made uPVC door frame, made of uPVC extruded section, of size 65 mm x 55 mm with wall thickness 2.0 mm (? 0.2mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm ( ? 0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge.Providing and fixing factory made uPVC door frame, made of uPVC extruded section, of size 65 mm x 55 mm with wall thickness 2.0 mm (? 0.2mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm ( ? 0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001163 | 115 | metre |
| 52 | 1.51 | 50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | BI01010001010000000000000515BI0100001164 | 21.133 | cum |
| 53 | 1.52 | od3270/2020_2021 : Supplying and fixing fero cement racks including all cost and conveyance of materials , all\rlabour charges etc. complete. | BI01010001010000000000000515BI0100001165 | 211.2 | sqm |
| 54 | 1.53 | 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | BI01010001010000000000000515BI0100001166 | 1560.55 | sqm |
| 55 | 1.54 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001167 | 4514.51 | sqm |
| 56 | 1.55 | 13.73.1 : Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and directions of the Engineer-in-Charge:15 mm wide and 15 mm deep groove | BI01010001010000000000000515BI0100001168 | 1533.48 | metre |
| 57 | 1.56 | 13.28.4 : 12 mm thick plain cement mortar bands in cement mortar 1:4 ( 1 cement : 4 fine sand) :Moulded Band | BI01010001010000000000000515BI0100001169 | 2650.9 | per meter per cm |
| 58 | 1.57 | 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) | BI01010001010000000000000515BI0100001170 | 267.342 | sqm |
| 59 | 1.58 | od11017/2020_2021 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications excluding priming coat, preparation of surface, etc. complete.\rOn steel work | BI01010001010000000000000515BI0100001171 | 258.9 | sqm |
| 60 | 1.59 | 13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | BI01010001010000000000000515BI0100001172 | 3237.38 | sqm |
| 61 | 1.6 | 13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | BI01010001010000000000000515BI0100001173 | 3237.38 | sqm |
| 62 | 1.61 | 13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | BI01010001010000000000000515BI0100001174 | 2650.2 | sqm |
| 63 | 1.62 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work | BI01010001010000000000000515BI0100001175 | 598.704 | sqm |
| 64 | 1.63 | 11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001176 | 601.809 | sqm |
| 65 | 1.64 | 11.40 : Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. | BI01010001010000000000000515BI0100001177 | 166.996 | sqm |
| 66 | 1.65 | 16.89 : Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi models location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. | BI01010001010000000000000515BI0100001178 | 32.64 | sqm |
| 67 | 1.66 | 11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. | BI01010001010000000000000515BI0100001179 | 566.397 | sqm |
| 68 | 1.67 | 8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm | BI01010001010000000000000515BI0100001180 | 8.477 | sqm |
| 69 | 1.68 | 8.13.1 : Providing and laying Polished Granite stone flooring in required design and\npatterns, in linear as well as curvilinear portions of the building all complete as\nper the architectural drawings with 18 mm thick stone slab over 20 mm (average)\nthick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with\ncement slurry and pointing with white cement slurry admixed with pigment of\nmatching shade including rubbing , curing and polishing etc. all complete as\nspecified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent. | BI01010001010000000000000515BI0100001181 | 163.176 | sqm |
| 70 | 1.69 | 8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work | BI01010001010000000000000515BI0100001182 | 273.48 | metre |
| 71 | 1.7 | 18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | BI01010001010000000000000515BI0100001183 | 10000 | Litre |
| 72 | 1.71 | 25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure\nequalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of\n6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic\ncontacts with nuts and washers etc. of stainless steel grade 316, of the required\ncapacity and in required numbers.\nc) Providing and filling, two part pump filled, structural silicone sealant and one\npart weather silicone sealant compatible with the structural silicone sealant of\nrequired bite size in a clean and controlled factory / work shop environment ,\nincluding double sided spacer tape, setting blocks and backer rod, all of approved\ngrade, brand and manufacture, as per the approved sealant design, within and all\naround the perimeter for holding glass.\nd) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick\nand of sizes, shapes and profiles, as required as per the site conditions, to seal the\ngap between the building structure and all its interfaces with curtain glazing to\nmake it watertight.\ne) Making provision for drainage of moisture/ water that enters the curtain glazing\nsystem to make it watertight, by incorporating principles of pressure equalization,\nproviding suitable gutter profiles at bottom (if required), making necessary holes\nof required sizes and of required numbers etc. complete. This item includes cost\nof all inputs of designing, labour for fabricating and installation of aluminium grid,\ninstallation of glazed units, T&P, scaffolding and other incidental charges including\nwastages etc., enabling temporary structures and services, cranes or cradles etc.\nas described above and as specified. The item includes the cost of getting all the\nstructural and functional design including shop drawings checked by a structural\ndesigner, dully approved by Engineer-in-charge.\nThe item also includes the cost of all mock ups at site, cost of all samples of the\nindividual components for testing in an approved laboratory, field tests on the\nassembled working structural glazing as specified, cleaning and protection till the\nhanding over of the building for occupation. In the end, the Contractor shall provide\na water tight structural glazing having all the performance characteristics etc. all\ncomplete as required, as per the Architectural drawings, as per item description,\nas specified, as per the approved shop drawings and as directed by the Engineerin-\nCharge.\nNote:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded\naluminium section capping for fixing in the grooves of the curtain glazing and\nvermin proof stainless steel wire mesh shall be paid for separately under relevant\nitems under this sub-head. However, for the purpose of payment, only the actual\narea of structural glazing (including width of grooves ) on the external face shall\nbe measured in sqm. up to two decimal places.\nNote:-2. The following performance test are to be conducted on structural glazing\nsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratories\naccreditated by NABL(National Accreditation Board for Testing and Calibration\nLaboratories), Department of Science & Technologies, India. Cost of testing is\npayable separately. The NIT approving authority will decide the necessity of testing\non the basis of cost of the work, cost of the test and importance of the work.\nPerformance Testing of Structural glazing system\nTests to be conducted in the NBL Certified laboratories\n1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to\n+300pa) as per\nASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”\n2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing\nmethod for a range up to 2000 ml.”\n3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing\nmethod for a range upto 2000 ml”\n4. Structural Performance Deflection and deformation by static air pressure test\n(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing\nmethod for a range upto 50 mm”\n5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for\nQualitative test” Tests to be conducted on site\n6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)\nupto 2000ml”Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specifieddesign loads conforming to IS 875 part III (the system must passed the proof testat 1.5 times design wind pressure without any failure), including functional designof the aluminum sections for fixing glazing panels of various thicknesses, aluminiumcleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmokeseals, microwave cured EPDM gaskets for water tightness, pressureequalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3Dimentional movement for achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetalliccontacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and onepart weather silicone sealant compatible with the structural silicone sealant ofrequired bite size in a clean and controlled factory / work shop environment ,including double sided spacer tape, setting blocks and backer rod, all of approvedgrade, brand and manufacture, as per the approved sealant design, within and allaround the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thickand of sizes, shapes and profiles, as required as per the site conditions, to seal thegap between the building structure and all its interfaces with curtain glazing tomake it watertight.e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete. This item includes costof all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges includingwastages etc., enabling temporary structures and services, cranes or cradles etc.as described above and as specified. The item includes the cost of getting all thestructural and functional design including shop drawings checked by a structuraldesigner, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of theindividual components for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning and protection till thehanding over of the building for occupation. In the end, the Contractor shall providea water tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extrudedaluminium section capping for fixing in the grooves of the curtain glazing andvermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub-head. However, for the purpose of payment, only the actualarea of structural glazing (including width of grooves ) on the external face shallbe measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazingsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies, India. Cost of testing ispayable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to+300pa) as perASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testingmethod for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testingmethod for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method forQualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml” | BI01010001010000000000000515BI0100001184 | 32.401 | sqm |
| 73 | 1.72 | 25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising of\nhermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units\nof size and shape as required and specified, comprising of an outer heat\nstrengthened float glass 6mm thick, of approved colour and shade with reflective\nsoft coating on surface # 2 of approved colour and shade, an inner Heat strengthned\nclear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary\nseal and secondary seal (structural silicone sealant) etc. all complete for the required\nperformances, as per the Architectural drawings, as per the approved shop\ndrawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall\nbe assembled in the factory/ workshop of the glass processor. (Payment for fixing\nof IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment,\nonly the actual area of glass on face # 1 of the glass panels (excluding the areas of\nthe grooves and weather silicone sealant) provided and fixed in position, shall be\nmeasured in sqm.\n(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on\nface # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make\nhaving properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection\ninternal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-\n0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance\nglass shall be decided by technical sanctioning authority as per the site requirementProviding, assembling and supplying vision glass panels (IGUs) comprising ofhermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel unitsof size and shape as required and specified, comprising of an outer heatstrengthened float glass 6mm thick, of approved colour and shade with reflectivesoft coating on surface # 2 of approved colour and shade, an inner Heat strengthnedclear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primaryseal and secondary seal (structural silicone sealant) etc. all complete for the requiredperformances, as per the Architectural drawings, as per the approved shopdrawings, as specified and as directed by the Engineer-in-Charge. The IGUs shallbe assembled in the factory/ workshop of the glass processor. (Payment for fixingof IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment,only the actual area of glass on face # 1 of the glass panels (excluding the areas ofthe grooves and weather silicone sealant) provided and fixed in position, shall bemeasured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating onface # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved makehaving properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflectioninternal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performanceglass shall be decided by technical sanctioning authority as per the site requirement | BI01010001010000000000000515BI0100001185 | 32.401 | sqm |
| 74 | 1.73 | 25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providing\nand supplying at site all accessories and hardwares for the openable panels as\nspecified and of the approved make such as heavy duty stainless steel friction\nhinges, min 4 -point cremone locking sets with stainless steel plates, handles,\nbuffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts,\nwashers etc. all complete as per the Architectural drawings, as per the approved\nshop drawings, as specified and as directed by the Engineer-in-Charge.Extra for openable side / top hung vision glass panels (IGUs) including providingand supplying at site all accessories and hardwares for the openable panels asspecified and of the approved make such as heavy duty stainless steel frictionhinges, min 4 -point cremone locking sets with stainless steel plates, handles,buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts,washers etc. all complete as per the Architectural drawings, as per the approvedshop drawings, as specified and as directed by the Engineer-in-Charge. | BI01010001010000000000000515BI0100001186 | 4.68 | sqm |
| 75 | 2 | Appendix B- Rain water harvesting tank | BI01010001010000000000000515BI0100001187 | ||
| 76 | 2.01 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001188 | 14.7 | cum |
| 77 | 2.02 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001189 | 2.4 | cum |
| 78 | 2.03 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001190 | 9.629 | cum |
| 79 | 2.04 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | BI01010001010000000000000515BI0100001191 | 78.82 | sqm |
| 80 | 2.05 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001192 | 16.12 | sqm |
| 81 | 2.06 | 5.9.16.1 : Edges of slabs and breaks in floors and wallsUnder 20 cm wide | BI01010001010000000000000515BI0100001193 | 44.2 | metre |
| 82 | 2.07 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001194 | 1155.48 | kilogram |
| 83 | 2.08 | 50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | BI01010001010000000000000515BI0100001195 | 50 | metre |
| 84 | 2.09 | 50.18.9.22.1 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow | BI01010001010000000000000515BI0100001196 | 5 | no |
| 85 | 2.1 | 50.18.9.22.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend | BI01010001010000000000000515BI0100001197 | 8 | no |
| 86 | 2.11 | 50.18.9.22.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee | BI01010001010000000000000515BI0100001198 | 8 | no |
| 87 | 2.12 | 23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- chargesSupplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges | BI01010001010000000000000515BI0100001199 | 1.36 | cum |
| 88 | 2.13 | 23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-ChargeSupplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge | BI01010001010000000000000515BI0100001200 | 0.45 | cum |
| 89 | 2.14 | 23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001201 | 0.45 | cum |
| 90 | 3 | Appendix C: Water supply and sanitary works | BI01010001010000000000000515BI0100001202 | ||
| 91 | 3.01 | 17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid | BI01010001010000000000000515BI0100001203 | 8 | each |
| 92 | 3.02 | 17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | BI01010001010000000000000515BI0100001204 | 6 | each |
| 93 | 3.03 | 17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brasspillar taps | BI01010001010000000000000515BI0100001205 | 18 | each |
| 94 | 3.04 | 17.78 : Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete. | BI01010001010000000000000515BI0100001206 | 2 | each |
| 95 | 3.05 | 17.4.1 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern | BI01010001010000000000000515BI0100001207 | 8 | each |
| 96 | 3.06 | 17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap | BI01010001010000000000000515BI0100001208 | 2 | each |
| 97 | 3.07 | 17.32.3 : Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Oval shape 450x350 mm (outer dimensions) | BI01010001010000000000000515BI0100001209 | 18 | each |
| 98 | 3.08 | 50.17.1.2 : Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. | BI01010001010000000000000515BI0100001210 | 20 | no |
| 99 | 3.09 | 18.65 : Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms.Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fittings arrangements, weighing not less than 106 gms. | BI01010001010000000000000515BI0100001211 | 20 | each |
| 100 | 3.1 | od76970/2019_2020 : Providing and fixing 1m long stainless steel horizontal and vertical grab rails 50mm dia etc., ifixed on wall with SS screws for physically challenged toilet | BI01010001010000000000000515BI0100001212 | 4 | each |
| 101 | 3.11 | od76971/2019_2020 : Providing and fixing 1.20m long stainless steel hinged support rail 50mm dia. fixed on wall with SS screws near the water closet for physically challenged toilet | BI01010001010000000000000515BI0100001213 | 2 | each |
| 102 | 3.12 | 17.10.1.4 : Kitchen sink with drain board510x1040 mm bowl depth 178 mm | BI01010001010000000000000515BI0100001214 | 1 | each |
| 103 | 3.13 | 50.18.7.6.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall | BI01010001010000000000000515BI0100001215 | 45 | metre |
| 104 | 3.14 | 50.18.8.6.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2 | BI01010001010000000000000515BI0100001216 | 60 | metre |
| 105 | 3.15 | 50.18.8.8.2 : Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2 | BI01010001010000000000000515BI0100001217 | 31 | metre |
| 106 | 3.16 | 50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001218 | 100 | metre |
| 107 | 3.17 | 50.18.7.4.2 : Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall | BI01010001010000000000000515BI0100001219 | 82 | metre |
| 108 | 3.18 | 50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 | BI01010001010000000000000515BI0100001220 | 48 | metre |
| 109 | 3.19 | 18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore | BI01010001010000000000000515BI0100001221 | 39 | each |
| 110 | 3.2 | 18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore | BI01010001010000000000000515BI0100001222 | 14 | each |
| 111 | 3.21 | 50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. | BI01010001010000000000000515BI0100001223 | 16 | no |
| 112 | 3.22 | 18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore | BI01010001010000000000000515BI0100001224 | 31 | each |
| 113 | 3.23 | 18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore | BI01010001010000000000000515BI0100001225 | 2 | each |
| 114 | 3.24 | 18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore | BI01010001010000000000000515BI0100001226 | 3 | each |
| 115 | 3.25 | 18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore | BI01010001010000000000000515BI0100001227 | 13 | no |
| 116 | 3.26 | 50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 | BI01010001010000000000000515BI0100001228 | 35 | metre |
| 117 | 3.27 | 50.18.8.9.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 | BI01010001010000000000000515BI0100001229 | 10 | metre |
| 118 | 3.28 | 50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001230 | 40 | metre |
| 119 | 3.29 | od10523/2020_2021 : PVC WEEP HOLES- Providing weep holes using 110 mm pipe . PVC pipes working pressure 6 kg /sq.cm including cost of materials, conveyance, labour charges etc. complete. ( Similar to DSR 60.6) | BI01010001010000000000000515BI0100001231 | 10 | metre |
| 120 | 3.3 | 18.36.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 grades stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001232 | 10 | each |
| 121 | 4 | Appendix D: Grease cum trash trap | BI01010001010000000000000515BI0100001233 | ||
| 122 | 4.01 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001234 | 2.6 | cum |
| 123 | 4.02 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001235 | 0.3 | cum |
| 124 | 4.03 | 6.2.2 : Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001236 | 1.4 | cum |
| 125 | 4.04 | 4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001237 | 0.15 | cum |
| 126 | 4.05 | 50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete | BI01010001010000000000000515BI0100001238 | 9 | sqm |
| 127 | 4.06 | 19.18.1 : Supplying and fixing C.I with out frame for manholes:455 x 610 mm rectangular C.I cover ( light duty ) the weight of the cover to be no less than 23 kg | BI01010001010000000000000515BI0100001239 | 2 | each |
| 128 | 4.07 | 50.18.9.22.5 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee | BI01010001010000000000000515BI0100001240 | 2 | no |
| 129 | 5 | Appendix E: Roof water disposal | BI01010001010000000000000515BI0100001241 | ||
| 130 | 5.01 | 50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001242 | 52 | metre |
| 131 | 5.02 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001243 | 0.48 | cum |
| 132 | 5.03 | 6.2.1 : Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001244 | 0.84 | cum |
| 133 | 5.04 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001245 | 5.6 | sqm |
| 134 | 6 | Appendix F: Waste water treatment and disposal syste, | BI01010001010000000000000515BI0100001246 | ||
| 135 | 6.01 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001247 | 13.751 | cum |
| 136 | 6.02 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | BI01010001010000000000000515BI0100001248 | 1.966 | cum |
| 137 | 6.03 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001249 | 0.787 | cum |
| 138 | 6.04 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001250 | 3.497 | cum |
| 139 | 6.05 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001251 | 0.353 | cum |
| 140 | 6.06 | 13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001252 | 20.125 | sqm |
| 141 | 6.07 | 50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 | BI01010001010000000000000515BI0100001253 | 2.5 | metre |
| 142 | 6.08 | 50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | BI01010001010000000000000515BI0100001254 | 3 | metre |
| 143 | 6.09 | 50.18.9.21.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend | BI01010001010000000000000515BI0100001255 | 1 | no |
| 144 | 6.1 | 50.18.9.21.5 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee | BI01010001010000000000000515BI0100001256 | 1 | no |
| 145 | 6.11 | 50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001257 | 6 | metre |
| 146 | 6.12 | 50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl | BI01010001010000000000000515BI0100001258 | 1 | no |
| 147 | 6.13 | 50.18.9.22.5 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee | BI01010001010000000000000515BI0100001259 | 2 | no |
| 148 | 6.14 | 19.18.2 : Supplying and fixing C.I with out frame for manholes:500 mm diameter C.I. (medium duty) the weight of the cover to be not less than 58 kg | BI01010001010000000000000515BI0100001260 | 4 | each |
| 149 | 6.15 | 50.18.7.6.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall | BI01010001010000000000000515BI0100001261 | 12 | metre |
| 150 | 6.16 | 4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001262 | 1.8 | cum |
| 151 | 6.17 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | BI01010001010000000000000515BI0100001263 | 20.24 | sqm |
| 152 | 6.18 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001264 | 9.838 | sqm |
| 153 | 6.19 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001265 | 1.89 | sqm |
| 154 | 6.2 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001266 | 349 | kilogram |
| 155 | 6.21 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001267 | 6 | kg |
| 156 | 7 | Appendix G: Upflow Anaerobic Filter | BI01010001010000000000000515BI0100001268 | ||
| 157 | 7.01 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001269 | 36.18 | cum |
| 158 | 7.02 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | BI01010001010000000000000515BI0100001270 | 15.93 | cum |
| 159 | 7.03 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001271 | 1.405 | cum |
| 160 | 7.04 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001272 | 6.924 | cum |
| 161 | 7.05 | 50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall | BI01010001010000000000000515BI0100001273 | 36 | metre |
| 162 | 7.06 | 50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 | BI01010001010000000000000515BI0100001274 | 2 | metre |
| 163 | 7.07 | 50.18.9.22.5 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee | BI01010001010000000000000515BI0100001275 | 1 | no |
| 164 | 7.08 | 19.18.2 : Supplying and fixing C.I with out frame for manholes:500 mm diameter C.I. (medium duty) the weight of the cover to be not less than 58 kg | BI01010001010000000000000515BI0100001276 | 3 | each |
| 165 | 7.09 | 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) | BI01010001010000000000000515BI0100001277 | 42.232 | sqm |
| 166 | 7.1 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001278 | 2.43 | sqm |
| 167 | 7.11 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | BI01010001010000000000000515BI0100001279 | 74.363 | sqm |
| 168 | 7.12 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | BI01010001010000000000000515BI0100001280 | 13.5 | sqm |
| 169 | 7.13 | 5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars | BI01010001010000000000000515BI0100001281 | 692.4 | kg |
| 170 | 8 | Appendix H: Waste water treatment and disposal system | BI01010001010000000000000515BI0100001282 | ||
| 171 | 8.01 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001283 | 8.96 | cum |
| 172 | 8.02 | 2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | BI01010001010000000000000515BI0100001284 | 2.24 | cum |
| 173 | 8.03 | 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001285 | 1.319 | cum |
| 174 | 8.04 | 5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001286 | 0.605 | cum |
| 175 | 8.05 | 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) | BI01010001010000000000000515BI0100001287 | 32.97 | sqm |
| 176 | 8.06 | 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001288 | 22 | kg |
| 177 | 8.07 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001289 | 52.76 | kilogram |
| 178 | 9 | Appendix I: Bore well ,pump set and pumping main | BI01010001010000000000000515BI0100001290 | ||
| 179 | 9.01 | od10525/2020_2021 : Providing and fixing 1HP Motor with pumpset, erection of open well submersible pumpset capable of lifting 120lpmof water against a total head of 20m with accessories such as non return valve, full way wheel valve, ICTP switch, voltmeter and ammeter, panel board. contractor to get approval of Engineer in charge on the selection of pump satisfying the design parameters. Capacity of pump may vary with different suppliers according to their manufacturing standard and no claim is accepted in later stage . if suppliers can provide only higher capacity pumps satisfying the design criteria | BI01010001010000000000000515BI0100001291 | 1 | each |
| 180 | 9.02 | 18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes | BI01010001010000000000000515BI0100001292 | 50 | metre |
| 181 | 9.03 | od76968/2019_2020 : Drilling Borewell of suitable size to accommodate well casing pipe of internal diameter not less than 150mm for varios strata up to 150m below ground level having an average 40m overburden in all class of soil and rock inclusive of hire charges for machineries and other accessories and stores ,putting up temporary shed and storing equipments ,cost of fuel ,oil and other incidential items to complete the work but excluding the cost of casing pipe etc complete. | BI01010001010000000000000515BI0100001293 | 100 | metre |
| 182 | 9.04 | od76969/2019_2020 : Supplying ad erection of 180 mm PVC pipe (6kg/cm2) or above diameter PVC casing (ISI marked) and labour charges ,conveyance to site etc complete. | BI01010001010000000000000515BI0100001294 | 48 | metre |
| 183 | 9.05 | 50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall | BI01010001010000000000000515BI0100001295 | 25 | metre |
| 184 | 9.06 | 50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall | BI01010001010000000000000515BI0100001296 | 20 | metre |
| 185 | 9.07 | 50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 | BI01010001010000000000000515BI0100001297 | 50 | metre |
| 186 | 9.08 | 50.18.9.14.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall | BI01010001010000000000000515BI0100001298 | 50 | metre |
| 187 | 9.09 | 50.18.9.16.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001299 | 50 | metre |
| 188 | 10 | Appendix J : Miscellaeous work | BI01010001010000000000000515BI0100001300 | ||
| 189 | 10.01 | 2.34.1 : Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20% | BI01010001010000000000000515BI0100001301 | 580.883 | Litre |
| 190 | 10.02 | 2.35.2.1 : Along the external wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including drilling and plugging holes etc:With Chlorpyriphosl Lindane E.C.20% with 1% concentration | BI01010001010000000000000515BI0100001302 | 91.3 | metre |
| 191 | 10.03 | 2.35.3.1 : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | BI01010001010000000000000515BI0100001303 | 375.458 | sqm |
| 192 | 10.04 | 16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001304 | 577.5 | sqm |
| 193 | 11 | Appendix K: Electrification | |||
| 194 | 11.0001 | 90.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | 99 | point | |
| 195 | 11.0002 | 90.2.1.9 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Twin Control light point with 6A, plate ceiling rose - Medium Point | 3 | point | |
| 196 | 11.0003 | 90.2.1.3 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | 29 | point | |
| 197 | 11.0004 | 90.2.1.4 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | 29 | point | |
| 198 | 11.0005 | 90.2.1.6 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | 22 | each | |
| 199 | 11.0006 | 90.2.1.7 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point | 9 | each | |
| 200 | 11.0007 | 90.3.21.3 : Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture | 25 | each | |
| 201 | 11.0008 | 90.3.20.3 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | 45 | each | |
| 202 | 11.0009 | 90.3.7 : Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required. | 8 | each | |
| 203 | 11.001 | 90.3.24.3 : Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture | 8 | each | |
| 204 | 11.0011 | od216309/2019_2020 : Supply, conveyance, installation, testing and commissioning of LED bulk head fittings IP65 directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.(Philips/Bajaj/Havells/Wipro) | 7 | each | |
| 205 | 11.0012 | od185713/2018_2019 : Supply and Fixing the 200 plastic shade in the existing front fitting and giving necessary connections as required | 29 | each | |
| 206 | 11.0013 | od216311/2019_2020 : Supply and fixing Backelite batten straight/ angle holder including connection etc. as required | 29 | each | |
| 207 | 11.0014 | od216313/2019_2020 : Supply and providing the 9W LED lamp in the existing fittings as required | 29 | each | |
| 208 | 11.0015 | 90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | 29 | each | |
| 209 | 11.0016 | od185715/2018_2019 : Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required. | 8.7 | metre | |
| 210 | 11.0017 | 90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C | 29 | each | |
| 211 | 11.0018 | 90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. | 9 | each | |
| 212 | 11.0019 | od216315/2019_2020 : Supply, Conveyance, installation , testing and commissioning of 300/305 mm sweep light duty exhaust fans in metal frame in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. | 4 | each | |
| 213 | 11.002 | od185735/2018_2019 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. - 300/ 305 mm, single phase 1400 rpm heavy duty exhaust fan in metal frame | 5 | each | |
| 214 | 11.0021 | 90.15.4.1 : Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 8 | each | |
| 215 | 11.0022 | 90.3.18.1 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps | 12 | metre | |
| 216 | 11.0023 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | 10 | each | |
| 217 | 11.0024 | 1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) | 1 | each | |
| 218 | 11.0025 | 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) | 8 | each | |
| 219 | 11.0026 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | 16 | each | |
| 220 | 11.0027 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | 10 | each | |
| 221 | 11.0028 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | 16 | each | |
| 222 | 11.0029 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | 10 | each | |
| 223 | 11.003 | 90.10.3.15 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator | 1 | each | |
| 224 | 11.0031 | 90.10.3.32 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator | 1 | each | |
| 225 | 11.0032 | 90.10.3.33 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket | 1 | each | |
| 226 | 11.0033 | 90.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm | 120 | metre | |
| 227 | 11.0034 | 90.6.10.2 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm | 50 | metre | |
| 228 | 11.0035 | 1.17.2 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm | 30 | metre | |
| 229 | 11.0036 | 1.17.4 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm | 40 | metre | |
| 230 | 11.0037 | 1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm | 50 | metre | |
| 231 | 11.0038 | 1.17.13 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm | 30 | metre | |
| 232 | 11.0039 | 1.17.20 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm | 30 | metre | |
| 233 | 11.004 | 1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 10 | metre | |
| 234 | 11.0041 | 90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp | 80 | metre | |
| 235 | 11.0042 | 90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp | 30 | metre | |
| 236 | 11.0043 | 90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp | 25 | metre | |
| 237 | 11.0044 | 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) | 6 | set | |
| 238 | 11.0045 | 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) | 9 | set | |
| 239 | 11.0046 | 9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) | 4 | set | |
| 240 | 11.0047 | 90.16.1.1 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) | 170 | metre | |
| 241 | 11.0048 | 90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | 220 | metre | |
| 242 | 11.0049 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | 80 | metre | |
| 243 | 11.005 | 90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) | 30 | metre | |
| 244 | 11.0051 | 90.16.1.6 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) | 20 | metre | |
| 245 | 11.0052 | 90.16.5.1 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) | 32 | each | |
| 246 | 11.0053 | 90.16.5.2 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) | 30 | each | |
| 247 | 11.0054 | 90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) | 18 | each | |
| 248 | 11.0055 | 90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) | 10 | each | |
| 249 | 11.0056 | 90.16.5.6 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG) | 8 | each | |
| 250 | 11.0057 | od184351/2018_2019 : Supplying and laying 8 SWG copper at 0.60 metre below ground level for conductor earthelectrode, including connection/ termination with GI thimble etc. as required. | 22 | metre | |
| 251 | 11.0058 | od184352/2018_2019 : Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required3.15 mm copper conductor (10 SWG) | 20 | metre | |
| 252 | 11.0059 | 90.16.2.1 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) | 42 | metre | |
| 253 | 11.006 | od184356/2018_2019 : Supply and providing 25x3mm brass nut and bolt etc. as required. | 25 | each | |
| 254 | 11.0061 | od184357/2018_2019 : Supply and providing 25x6mm brass nut and bolt etc. as required. | 36 | each | |
| 255 | 11.0062 | od184358/2018_2019 : Supply and providing 12x3mm brass nut and bolt etc. as required. | 20 | each | |
| 256 | 11.0063 | 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 9 | set | |
| 257 | 11.0064 | od185950/2018_2019 : Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system | 1.9 | metre | |
| 258 | 11.0065 | od185952/2018_2019 : Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate | 48.6 | metre | |
| 259 | 11.0066 | 90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | each | |
| 260 | 11.0067 | 90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) | 3 | each | |
| 261 | 11.0068 | 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 1 | each | |
| 262 | 11.0069 | 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 3 | each | |
| 263 | 11.007 | 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 3 | each | |
| 264 | 11.0071 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 64 | each | |
| 265 | 11.0072 | 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole | 6 | each | |
| 266 | 11.0073 | od216337/2019_2020 : supply andinstallation of 63A 415V 50Hz, AC 23A duty TPN SDF for DIN fuse in sheet steel enclosure with handle assembly, door interlock and padlocking arrangements on existing angle iron framework or direclty to wall and giving connections. with HRC fuse links | 1 | each | |
| 267 | 11.0074 | od216339/2019_2020 : Supplying and fixing 63 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board | 1 | each | |
| 268 | 11.0075 | od216341/2019_2020 : Supplying and fixing 63, HRC Fuse with HRC Fuse link with connections, in existing meter board | 3 | each | |
| 269 | 11.0076 | od216343/2019_2020 : Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6535) and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required. | 1 | each | |
| 270 | 11.0077 | od185954/2018_2019 : Supply and providing suitable Iron Hook grouted on wall for binding the service wire | 1 | each | |
| 271 | 11.0078 | od185956/2018_2019 : Supply and laying light gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.32 mm(service pipe) | 3 | metre | |
| 272 | 11.0079 | od184364/2018_2019 : Aluminium anodised Danger Notice Board of size 200x150mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour. | 1 | each | |
| 273 | 11.008 | od184365/2018_2019 : painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB panel board etc as required. 2.5 cm, 4 cm or 5 cm height | 40 | each | |
| 274 | 11.0081 | od214707/2018_2019 : Supply, conveyance, Installation, testing & commissioning of 15 KVA Diesel Generator set with integral acoustic enclosure as per CPCB norms with srandared acessories as per technical details given below. 1. Engine : a) Make of Engine - Kirloskar/Escorts/Cummins/Mahendra b) Type of Engine - Diesel Engine c) No. of Cylinders - As per manufactures standards. d) Method of Cooling - Water cooled with radiator. e) Aspiration Turbo charged after cooled. f) Design - Suitable for generating set operation 2.Standard accessories with Diesel Engine a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Mechnical governor g) Fuel filter h) Lubricating oil filter i) Exhaust silencer j) Exhaust Muffler k) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter e) Battery charging Ammeter 4. Safety Controls for Engine a) Trip for low lubricating oil pressure b) Trip for high water temperature. 6. Brushless Alternator a) Make - Kirloskar/KEL/Crompton/Greaves/Stanford b) Type - Self exited and self regulated. c) Capacity - 15 KVA/12 K W @ 0.8PF d) System of Voltage - 1 phase, 230 V, e) Frequency - 50 Hz f) Insulation - Class F/H The Alternator should confirm to IS 4722. Operation and service manual, spares and tools shall be provided. 7. Fuel Tank Suitable size built in type integrated with the acoustic enclosure Fuel connection shall be done as per standards 8. Battery Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. Automatic Battery charger Solid state phase indication lamp for supply ON/OFF with HRC protection. standard conrol panel wih 63A MCB and accessaries such as Multi function meter and separate Energy Meter etc. complete | 1 | each | |
| 275 | 11.0082 | 14.1 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 1 | cum | |
| 276 | 11.0083 | 14.7 : Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. | 2 | cum | |
| 277 | 11.0084 | 14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. | 9 | cum | |
| 278 | 11.0085 | 14.12 : Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels. | 2 | sqm | |
| 279 | 11.0086 | od214745/2018_2019 : supply and providing 4.5Kg Dry Chemical Powder Type fire Extinguisher with hose and clamps including fixing it to wall as required. | 3 | each | |
| 280 | 11.0087 | od214725/2018_2019 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required | 2 | each | |
| 281 | 11.0088 | od214747/2018_2019 : Supply and providing 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet | 1 | per sqm | |
| 282 | 11.0089 | od184373/2018_2019 : Supply, providing and fixing 100A, 4 pole On-Load Change Over Switches unit inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required. | 1 | each | |
| 283 | 11.009 | od184376/2018_2019 : Charges towards the preparation of necessary Plan, scheme and other related papers for submission to KSELB & KSEB for first sheet. | 12 | each | |
| 284 | 11.0091 | od184377/2018_2019 : Charges for additional sheet | 24 | each | |
| 285 | 11.0092 | od214757/2018_2019 : Charges to be remitted at KSELB and kseb for statuary fees for approval, power allocation and related fees.(Actual to be paid to the contractor based on producing original bills/ receipts). | 1 | each | |
| 286 | 11.0093 | 6.2 : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. | 10 | each | |
| 287 | 11.0094 | 6.3 : Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. | 10 | each | |
| 288 | 11.0095 | 6.4 : Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. | 20 | each | |
| 289 | 11.0096 | 6.7 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For horizontal run) | 200 | metre | |
| 290 | 11.0097 | 6.8 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For vertical run) | 70 | metre | |
| 291 | 11.0098 | 6.9 : Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For horizontal run) | 200 | metre | |
| 292 | 11.0099 | 6.10 : Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For vertical run) | 70 | metre | |
| 293 | 11.01 | 6.12 : Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. | 20 | each | |
| 294 | 11.0101 | 6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required. | 40 | metre | |
| 295 | 11.0102 | 6.15 : Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. | 40 | metre |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail