Providing Of Medical Gas Pipeline System , Oxygen Supply And Vacuum Pipe Line System And Bed Head Panels And Covid 19 Isolation Ward At Mh Bhuj ( Covid 19 )

Issued by Statutory Bodies & Commissions/Committees · Bhuj, Gujarat
Tender Value
42.50 Lakhs
Estimated cost
Bid Submission
04 Jul 2020
0 days left
EMD
85000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Auction
Location / State
Bhuj → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing Of Medical Gas Pipeline System , Oxygen Supply And Vacuum Pipe Line System And Bed Head Panels And Covid 19 Isolation Ward At Mh Bhuj ( Covid 19 )

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-Jul-2020

BOQ

Name of Work: PROVN OF MEDICAL GAS PIPELINE SYSTEM, OXYGEN SUPPLY AND VACUUM PIPE LINE SYSTEM AND BED HEAD PANELS AND COVID-19 ISOLATION WARD AT MH BHUJ (COVID-19)
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Supply, Installation, Testing and Commissioning of Copper Pipe of size 22mm OD X 0.9mm thick as per BS2871, Lloyd certified for the fallowing sizes complete all as specified and directed. Make : Mexflow/Mandev/IndiaBI01010001010000000000000515BI01000011131601RM
22All as per Item No. 01 here above but 15mm OD X 0.9mm thickBI01010001010000000000000515BI0100001114386RM
33All as per Item No. 01 here above but 12mm OD X 0.9mm thickBI01010001010000000000000515BI0100001115159RM
44Supply, installation, commissioning and testing of Medical Gas Outlet Points/Terminal Unit with matching probes: Supply, installation, testing and commissioning of Gas outlet points for Oxygen, Nitrous Oxide, Medical Air 4 Bar/7 Bar, Vacuum Port, front loading type, BS type for Double Lock with Probe - Oxygen complete all as specified and directed. Make : Arosons/PES/IndiaBI01010001010000000000000515BI010000111625Each
55All as per Item No. 04 here above but Double Lock with Probe - Nitrous Oxide.BI01010001010000000000000515BI01000011173Each
66All as per Item No. 04 here above but Double Lock with Probe - Air 4 Medical SetBI01010001010000000000000515BI01000011187Each
77All as per Item No. 04 here above but Double Lock with Probe - Vacuum SetBI01010001010000000000000515BI010000111925Each
88Supply and fixing of Factory Degreased Isolation Valves for 15mm Copper Pipe for Medical Usage with Brass Adaptors complete all as specified and directed. Make : AUDCO/Matrix/Legris/IndiaBI01010001010000000000000515BI010000112017Each
99Supply and fixing of Factory Degreased Isolation Valves for 22mm Copper Pipe for Medical Usage with Brass Adaptors complete all as specified and directed. Make : AUDCO/Matrix/Legris/IndiaBI01010001010000000000000515BI010000112113Each
1010Supply and fixing of ZONE VALVE BOXES (Without Valves) for Medical Usage Valve Box - 4 Gas Service (Size 15mm x 15mm x 22mm) with NIST connection & SS Valve for Oxygen complete all as specified and directed. Make : Arosons Products/PESBI01010001010000000000000515BI01000011222Each
1111Supply and fixing of ZONE VALVE BOXES (Without Valves) for Medical Usage Valve Box - 3 Gas Service (Size 15mm x 15mm x 22mm) with NIST connection & SS Valve for Oxygen complete all as specified and directed. Make : Arosons Products/PESBI01010001010000000000000515BI01000011232Each
1212Supply and fixing of ZONE VALVE BOXES (Without Valves) for Medical Usage Valve Box - 2 Gas Service ( Size 15mm x 15mm x 22mm) with NIST connection & SS Valve for Oxygen complete all as specified and directed. Make : Arosons Products/PESBI01010001010000000000000515BI01000011242Each
1313Supply, installation, commissioning and testing of medical gas central alarms should be capable of monitoring a maximum of 3 medical gas services by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital display of pressures . The medical gas area alarm Should fully satisfy the international standard. Each gas service should be displayed by coloured LED's to show 'Normal' (green), 'Low' and 'High Pressure' (red) conditions. Medical vacuum systems Should be displayed in the 'Normal' (green) and 'Low Vacuum' (red) conditions only. Failure indicators Should be displayed by flashing lights and normal indications Should be steady. The alarm panel should have a 'test' facility to prove the integrity of the internal circuits, LED's and audible warning. The alarm panel Should incorporate a volt free normally closed relay to allow for interconnection to either a medical gas central alarm system or an event recording circuit of a building management system. The alarm should be UL listed. The equipment should be ISO 13485 facility certified. (Approved makes OHIO Medical /Amvex / Biolume/ArosonsProducts )BI01010001010000000000000515BI01000011252Each
1414Supply and fixing of Oxygen Flow meter BPC (0-15 LPM) with Humidifier Bottle:- Make : -Prime Medical/Arosons/IndiaBI01010001010000000000000515BI010000112610Each
1515Supply, Installation, testing and commissioning of Ward Vacuum Unit with 600ml Polycarbonate suction jar complete all as specified and as directed. Make : Prime Medical/Arosons/IndiaBI01010001010000000000000515BI010000112710Each
1616OXYGEN GAS SYSTEM: \n(a) S & F for Main Oxygen Manifold 2 x 4 Cylinders with NRVs, Tail Pipes and Middle Frame all as specified as per medical standards complete all as specified and as directed.BI01010001010000000000000515BI01000011281Set
1717(b) S &F for Fully Automatic Oxygen Control Panel (Indigineous) with automatic cjangeover from Running Bank to reserve bank of cylinders and having non halogenated polymer in the high pressure side of the primary regulators and 40 micron inlet filter complete all as specified and as directed.BI01010001010000000000000515BI01000011291Nos
1818(c) S &F for 2-Cylinder Emergency Oxygen Manifold complete with NRVs, Tail Pipes and Pressure reducing system having non halogenated polymer material in the high pressure side of the regulators complete all as specified and as directed.BI01010001010000000000000515BI01000011301Set
1919VACUUM SYSTEM: \nS & F for 2 Nos. rotary vane vacuum pumps with Receiver, Filters, Electricals etc. complete all as specified and as directed.BI01010001010000000000000515BI01000011311Set
2020COMPRESSED GAS SYSTEM: \n(a) S &F for Consisting of 2 Nos Air Compressors, Tank Mounted, each Receiver Capacity 500 ltrs, common Air drier, Pressure Reducing Unit etc complete all as specified and as directed.BI01010001010000000000000515BI01000011321Set
2121(b) S & F for 3-Stage Breathing Air Filter as per specifications complete all as specified and as directed.BI01010001010000000000000515BI01000011331Set
2222NITROUS OXIDE SYSTEM: \n(a) S & F for Main Nitrous Oxide Manifold 2 x 1 cylinders with NRV's, Tail pipes and Middle frame complete all as specified and as directed.BI01010001010000000000000515BI01000011341Set
2323(b) S & F for Semi - automatic N2O Control Panel with Automatic Changeover (indigenous) from Running Bank to Reserve Bank of cylinders complete all as specified and as directed.BI01010001010000000000000515BI01000011351Nos
2424(c) S & F for 1-cylinder Emergency Nitrous Oxide Manifold complete with tail pipe, NRV and Pressure Regulator(Double Stage) complete all as specified and as directed.BI01010001010000000000000515BI01000011361Set
2525Supply, installation, commissioning and testing of medical gas central alarms should be capable of monitoring a maximum of 6 medical gas services by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital display of pressures . The medical gas area alarm Should fully satisfy the international standard. Each gas service should be displayed by coloured LED's to show 'Normal' (green), 'Low' and 'High Pressure' (red) conditions. Medical vacuum systems Should be displayed in the 'Normal' (green) and 'Low Vacuum' (red) conditions only. Failure indicators Should be displayed by flashing lights and normal indications Should be steady. The alarm panel should have a 'test' facility to prove the integrity of the internal circuits, LED's and audible warning. The alarm panel Should incorporate a volt free normally closed relay to allow for interconnection to either a medical gas central alarm system or an event recording circuit of a building management system. The alarm should be UL listed. The equipment should be ISO 13485 facility certified complete all as specified and as directed. (Approved makes OHIO Medical /Amvex / Biolume/ArosonsProducts )BI01010001010000000000000515BI01000011373Each
2626Supply and fixing of Oxygen Flow meter BPC (0-15 LPM) with Humidifier Bottle complete all as specified and as directed. Make : -Prime Medical/Arosons/IndiaBI01010001010000000000000515BI010000113815Each
2727Supply, Installation, testing and commissioning of Ward Vacuum Unit with 600ml Polycarbonate suction jar complete all as specified and as directed. Make : Prime Medical/Arosons/IndiaBI01010001010000000000000515BI010000113915Each
2828Supply & Fixing of Bed Head Panels with 3 X 15 Amp Sockets, 2 X Gas Ports (Oxygen & Vacuum), LED Lamp, Call Bell, Movable IV Stand, Basket, Stand For Monitor & 1 X Shelf all inclusive with connection to nearest electric supply point and medical gas pipelines complete all as specified and as directed.BI01010001010000000000000515BI010000114025Nos
2929S & F for Theatre Suction Unit with 2 x 2000 ml Polycarbonate Jars Set complete all as specified and directed.BI01010001010000000000000515BI01000011412Each

AI Tender Summary

OUR REF NO 24594769
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.50 Lakhs
LAST DATE 04-07-2020
Authority
Authority Name Military Engineer Services
Work Description Providing Of Medical Gas Pipeline System , Oxygen Supply And Vacuum Pipe Line System And Bed Head Panels And Covid 19 Isolation Ward At Mh Bhuj ( Covid 19 )
Basic Detail
Tender No 8708/E8
Bidding Type Auction
Location
City Bhuj
State Gujarat
Key Dates
Publish Date 27 Jun 2020
Submission Date 04 Jul 2020
Open Date 06 Jul 2020
Finance
Tender Value 42.50 Lakhs
Tender Fee 500
EMD 85000
Exemption Not Available
Document List
Tendernotice_1.pdf
PS8708Make.pdf
tender8708.pdf
59E253BF-A256-49B9-9056-C5C6242D5192.html
BOQ_393876.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 04, 2020
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 04, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 06, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

PS8708Make.pdf

pdf

tender8708.pdf

html

59E253BF-A256-49B9-9056-C5C6242D5192.html

xls

BOQ_393876.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders