Providing Of Medical Gas Pipeline System , Oxygen Supply And Vacuum Pipe Line System And Bed Head Panels And Covid 19 Isolation Ward At Mh Bhuj ( Covid 19 )
Tender Overview
Project Description
Providing Of Medical Gas Pipeline System , Oxygen Supply And Vacuum Pipe Line System And Bed Head Panels And Covid 19 Isolation Ward At Mh Bhuj ( Covid 19 )
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-Jul-2020 |
BOQ
| Name of Work: PROVN OF MEDICAL GAS PIPELINE SYSTEM, OXYGEN SUPPLY AND VACUUM PIPE LINE SYSTEM AND BED HEAD PANELS AND COVID-19 ISOLATION WARD AT MH BHUJ (COVID-19) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supply, Installation, Testing and Commissioning of Copper Pipe of size 22mm OD X 0.9mm thick as per BS2871, Lloyd certified for the fallowing sizes complete all as specified and directed. Make : Mexflow/Mandev/India | BI01010001010000000000000515BI0100001113 | 1601 | RM |
| 2 | 2 | All as per Item No. 01 here above but 15mm OD X 0.9mm thick | BI01010001010000000000000515BI0100001114 | 386 | RM |
| 3 | 3 | All as per Item No. 01 here above but 12mm OD X 0.9mm thick | BI01010001010000000000000515BI0100001115 | 159 | RM |
| 4 | 4 | Supply, installation, commissioning and testing of Medical Gas Outlet Points/Terminal Unit with matching probes: Supply, installation, testing and commissioning of Gas outlet points for Oxygen, Nitrous Oxide, Medical Air 4 Bar/7 Bar, Vacuum Port, front loading type, BS type for Double Lock with Probe - Oxygen complete all as specified and directed. Make : Arosons/PES/India | BI01010001010000000000000515BI0100001116 | 25 | Each |
| 5 | 5 | All as per Item No. 04 here above but Double Lock with Probe - Nitrous Oxide. | BI01010001010000000000000515BI0100001117 | 3 | Each |
| 6 | 6 | All as per Item No. 04 here above but Double Lock with Probe - Air 4 Medical Set | BI01010001010000000000000515BI0100001118 | 7 | Each |
| 7 | 7 | All as per Item No. 04 here above but Double Lock with Probe - Vacuum Set | BI01010001010000000000000515BI0100001119 | 25 | Each |
| 8 | 8 | Supply and fixing of Factory Degreased Isolation Valves for 15mm Copper Pipe for Medical Usage with Brass Adaptors complete all as specified and directed. Make : AUDCO/Matrix/Legris/India | BI01010001010000000000000515BI0100001120 | 17 | Each |
| 9 | 9 | Supply and fixing of Factory Degreased Isolation Valves for 22mm Copper Pipe for Medical Usage with Brass Adaptors complete all as specified and directed. Make : AUDCO/Matrix/Legris/India | BI01010001010000000000000515BI0100001121 | 13 | Each |
| 10 | 10 | Supply and fixing of ZONE VALVE BOXES (Without Valves) for Medical Usage Valve Box - 4 Gas Service (Size 15mm x 15mm x 22mm) with NIST connection & SS Valve for Oxygen complete all as specified and directed. Make : Arosons Products/PES | BI01010001010000000000000515BI0100001122 | 2 | Each |
| 11 | 11 | Supply and fixing of ZONE VALVE BOXES (Without Valves) for Medical Usage Valve Box - 3 Gas Service (Size 15mm x 15mm x 22mm) with NIST connection & SS Valve for Oxygen complete all as specified and directed. Make : Arosons Products/PES | BI01010001010000000000000515BI0100001123 | 2 | Each |
| 12 | 12 | Supply and fixing of ZONE VALVE BOXES (Without Valves) for Medical Usage Valve Box - 2 Gas Service ( Size 15mm x 15mm x 22mm) with NIST connection & SS Valve for Oxygen complete all as specified and directed. Make : Arosons Products/PES | BI01010001010000000000000515BI0100001124 | 2 | Each |
| 13 | 13 | Supply, installation, commissioning and testing of medical gas central alarms should be capable of monitoring a maximum of 3 medical gas services by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital display of pressures . The medical gas area alarm Should fully satisfy the international standard. Each gas service should be displayed by coloured LED's to show 'Normal' (green), 'Low' and 'High Pressure' (red) conditions. Medical vacuum systems Should be displayed in the 'Normal' (green) and 'Low Vacuum' (red) conditions only. Failure indicators Should be displayed by flashing lights and normal indications Should be steady. The alarm panel should have a 'test' facility to prove the integrity of the internal circuits, LED's and audible warning. The alarm panel Should incorporate a volt free normally closed relay to allow for interconnection to either a medical gas central alarm system or an event recording circuit of a building management system. The alarm should be UL listed. The equipment should be ISO 13485 facility certified. (Approved makes OHIO Medical /Amvex / Biolume/ArosonsProducts ) | BI01010001010000000000000515BI0100001125 | 2 | Each |
| 14 | 14 | Supply and fixing of Oxygen Flow meter BPC (0-15 LPM) with Humidifier Bottle:- Make : -Prime Medical/Arosons/India | BI01010001010000000000000515BI0100001126 | 10 | Each |
| 15 | 15 | Supply, Installation, testing and commissioning of Ward Vacuum Unit with 600ml Polycarbonate suction jar complete all as specified and as directed. Make : Prime Medical/Arosons/India | BI01010001010000000000000515BI0100001127 | 10 | Each |
| 16 | 16 | OXYGEN GAS SYSTEM: \n(a) S & F for Main Oxygen Manifold 2 x 4 Cylinders with NRVs, Tail Pipes and Middle Frame all as specified as per medical standards complete all as specified and as directed. | BI01010001010000000000000515BI0100001128 | 1 | Set |
| 17 | 17 | (b) S &F for Fully Automatic Oxygen Control Panel (Indigineous) with automatic cjangeover from Running Bank to reserve bank of cylinders and having non halogenated polymer in the high pressure side of the primary regulators and 40 micron inlet filter complete all as specified and as directed. | BI01010001010000000000000515BI0100001129 | 1 | Nos |
| 18 | 18 | (c) S &F for 2-Cylinder Emergency Oxygen Manifold complete with NRVs, Tail Pipes and Pressure reducing system having non halogenated polymer material in the high pressure side of the regulators complete all as specified and as directed. | BI01010001010000000000000515BI0100001130 | 1 | Set |
| 19 | 19 | VACUUM SYSTEM: \nS & F for 2 Nos. rotary vane vacuum pumps with Receiver, Filters, Electricals etc. complete all as specified and as directed. | BI01010001010000000000000515BI0100001131 | 1 | Set |
| 20 | 20 | COMPRESSED GAS SYSTEM: \n(a) S &F for Consisting of 2 Nos Air Compressors, Tank Mounted, each Receiver Capacity 500 ltrs, common Air drier, Pressure Reducing Unit etc complete all as specified and as directed. | BI01010001010000000000000515BI0100001132 | 1 | Set |
| 21 | 21 | (b) S & F for 3-Stage Breathing Air Filter as per specifications complete all as specified and as directed. | BI01010001010000000000000515BI0100001133 | 1 | Set |
| 22 | 22 | NITROUS OXIDE SYSTEM: \n(a) S & F for Main Nitrous Oxide Manifold 2 x 1 cylinders with NRV's, Tail pipes and Middle frame complete all as specified and as directed. | BI01010001010000000000000515BI0100001134 | 1 | Set |
| 23 | 23 | (b) S & F for Semi - automatic N2O Control Panel with Automatic Changeover (indigenous) from Running Bank to Reserve Bank of cylinders complete all as specified and as directed. | BI01010001010000000000000515BI0100001135 | 1 | Nos |
| 24 | 24 | (c) S & F for 1-cylinder Emergency Nitrous Oxide Manifold complete with tail pipe, NRV and Pressure Regulator(Double Stage) complete all as specified and as directed. | BI01010001010000000000000515BI0100001136 | 1 | Set |
| 25 | 25 | Supply, installation, commissioning and testing of medical gas central alarms should be capable of monitoring a maximum of 6 medical gas services by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital display of pressures . The medical gas area alarm Should fully satisfy the international standard. Each gas service should be displayed by coloured LED's to show 'Normal' (green), 'Low' and 'High Pressure' (red) conditions. Medical vacuum systems Should be displayed in the 'Normal' (green) and 'Low Vacuum' (red) conditions only. Failure indicators Should be displayed by flashing lights and normal indications Should be steady. The alarm panel should have a 'test' facility to prove the integrity of the internal circuits, LED's and audible warning. The alarm panel Should incorporate a volt free normally closed relay to allow for interconnection to either a medical gas central alarm system or an event recording circuit of a building management system. The alarm should be UL listed. The equipment should be ISO 13485 facility certified complete all as specified and as directed. (Approved makes OHIO Medical /Amvex / Biolume/ArosonsProducts ) | BI01010001010000000000000515BI0100001137 | 3 | Each |
| 26 | 26 | Supply and fixing of Oxygen Flow meter BPC (0-15 LPM) with Humidifier Bottle complete all as specified and as directed. Make : -Prime Medical/Arosons/India | BI01010001010000000000000515BI0100001138 | 15 | Each |
| 27 | 27 | Supply, Installation, testing and commissioning of Ward Vacuum Unit with 600ml Polycarbonate suction jar complete all as specified and as directed. Make : Prime Medical/Arosons/India | BI01010001010000000000000515BI0100001139 | 15 | Each |
| 28 | 28 | Supply & Fixing of Bed Head Panels with 3 X 15 Amp Sockets, 2 X Gas Ports (Oxygen & Vacuum), LED Lamp, Call Bell, Movable IV Stand, Basket, Stand For Monitor & 1 X Shelf all inclusive with connection to nearest electric supply point and medical gas pipelines complete all as specified and as directed. | BI01010001010000000000000515BI0100001140 | 25 | Nos |
| 29 | 29 | S & F for Theatre Suction Unit with 2 x 2000 ml Polycarbonate Jars Set complete all as specified and directed. | BI01010001010000000000000515BI0100001141 | 2 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.