| 1 | 1 | M&L for developing and planting hedges of height 30 cm and above, 30-30 Cm apart saplings, including excavation in trenches in any type of soil to a width 45 cm and depth 45 cm and filling the trenches with mixture of vermin compost/farm yard manure and red soil in proportion of 2:3 with necessary pesticides treatment including removing the surplus soil to a distance not exc 50m and depositing where directed and watering the hedges at regular intervals as required complete all as specified and directed. | | 800 | RM |
|---|
| 2 | 2 | Surface excavation not exceeding 30 cm deep and averaging 15 Cm deep and getting out in any type of soil, removing roots/vegetation from the excavated area, filling the excavated portion with mixture of vermin compost/farm yard manure and fertile soil in proportion of 2:3 with necessary pesticides treatment including removing the surplus soil to a distance not exc 50m and depositing where directed, complete all as specified and directed. | | 900 | Sqm |
|---|
| 3 | 3 | M&L for developing lawns by providing soft grass (Bermuda grass) by dibbling and planting grass tufts and watering the area/grown grass and mowing the developed lawn at regular intervals as required complete all as specified and directed. | | 900 | Sqm |
|---|
| 4 | 4 | Excavation in post holes (or similar holes) Each n exc 0.50 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm including filling the excavated portion with mixture of vermin compost/farm yard manure and fertile soil in proportion of 2:3 with necessary pesticides treatment including removing the surplus soil to a distance not exc 50m and depositing where directed, complete all as specified and directed. | | 400 | Each |
|---|
| 5 | 5 | Planting trees of different varities having 1.00 m to 1.50 m height and one year old with proportionate girth in the filled up pits and watering the plants at regular intervals as required till physical completion of the work (Phase I), complete all as specified and directed for the following species of trees: -\na) Neem\nb) Silveroak\nc) Shisham \nd) Saal\ne) Karang (f) Bougainvillea | | 400 | Each |
|---|
| 6 | 6 | S&F MS Flat iron tree guard, 60 cm dia and 150 cm high above ground, consisting 4 Nos 25x6 mm, 1.75 m long and 8 Nos 25x3mm and 1.5 m long vertical MS flatsrivetted to 3 Nos 25x6 mm MS flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia and 30 mm long bolts including painting with two coats of synthetic enamel paint over a coat of red oxide primer. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect to the entire satisfaction of Engineer in Charge. | | 50 | Each Job |
|---|
| 7 | 7 | Continuous brick edging with width equal to the depth of the brick, laid dry on end , at the required angle , using sub class 'B' old size brick , complete all as specified and directed. | | 1000 | RM |
|---|
| 8 | 8 | Supply, Laying, jonting and testing of XLPE cable insulated, screened, PVC sheathed, galvanised steel strip or wire armoured, electric LT cable, 1100 volts grade with stranded luminium conductor of size 16 sqmm, 4 core complete all as specified and directed. | | 425 | RM |
|---|
| 9 | 9 | Supplying, fixing, installation, commissioning and testing of outdoor type cubical weather proof factory made LT feeder pillar box of suitable size with minimum internal depth 500 mm made of 3.15 mm thick mild steel sheet with independent compartment for each feeder, duly powder coated having double door opening from front and back with locking arrangement, provision of entry & exit glands for cables 04 Nos, 200 Ampere capacity aluminimum bus bar including making all internal connections and mild steel stand for mounting of panel board made of angle iron of size 40 mm x 40 mm x 6 mm, 0.60 metre high along with necessary cement concrete for grounting of panel stand floor mounted type, comprising the adequate arrangement to fix the following incoming and out going MCCBs etc and connecting the cables glands and cable lugs, nut bolt and washers and connection with existing earthing complete all as specified and directed, comprising with the following: - \nINCOMING\na) MCCB, 4 pole, 63 Amps, 25 KA rupturing capacity - 01 No.\nb) Voltmeter 0 to 500 volts with selector switch and CT's - 01 No.\nc) Ampere meter 0 to 400 Amps with selector switch and CT's - 01 No.\nd) Indicator lamp LED type - 03 Nos\nOUTGOING\na) MCB TPN 40 amps, 4 pole, 10 KA, 'C' series - 02 Nos.\nb) FASD starter of capacity 5/7 HP - 02 No. | | 4 | Each Job |
|---|
| 10 | 10 | Supply, lowering in borewell, jointing & commissioning of submersible pumping set, water lubricated and water cooled complete with stream line non-return valve directly coupled with pump set and including motor and suitable for operation on 415 + 7.50% voltage, 3 phase, 50c/s, AC supply. The pump set shall be capable to deliver 150 LPM of water at a head of 60 Mtrs.( suitable for borewell dia 75 mm ) The electric motor shall be hermetically sealed, water lubricated, vertical type and shall be directly coupled to pump. Pump set should not be less than 3HP, complete all as specified and directed.\n(Note: The contractor shall submit the technical details of submersible pumping set for approval of GE and only after getting the approval from GE, pump set shall be procured. Make- Kirloskar/KSB/Crompton / Jyoti | | 1 | Each pump set |
|---|
| 11 | 11 | Supply, jointing and lowering GI medium grade flanged/socketed column pipe with two Nos. welded strips over flanged/socketed end for extra protection at each flangd/socketed each, complete internal bore of column pipe 40 mm, complete all as specified and directed. | | 15 | Each |
|---|
| 12 | 12 | Supply, fixing and testing cast iron non return valve, PN-1.0 ISI marked, heavy duty conforming to IS 5312/2004 of size 40 mm bore with flanged jointing on both ends, including jointing materials such as rubber/fibre board gasket, bolts, nuts and twin washers, complete all as specified and directed. | | 1 | Each |
|---|
| 13 | 13 | S&F of MS clamps made out of MS flat iron 80 mm wide x 800 mm long, 10 mm thick duly ribbed with MS flat iron 50x6 mm in cente, two plate with 4 Nos holes of 15 mm dia, 4 Nos bolts, nuts and washers 80x12 mm dia (02 nos on each side from centre as directed)stainless steel (suitable for lowering/lifting of pump set), complete all as specified and directed. | | 1 | Each set |
|---|
| 14 | 14 | S&F MS pipe 80 mm bore for making header, including all cutting/welding etc, complete all as specified and directed. | | 10 | RM |
|---|
| 15 | 15 | Supplying and fixing submersible cable 3 core flat of size 4 sqmm, 1100 volt grade with multi stranded copper conductor cable, PVC insulated and PVC sheathed, including suitable clamps, complete all as specified and directed. | | 80 | RM |
|---|
| 16 | 16 | Supplying, installing, commissioning and testing open well submersible pump (pump and electric motor), electrically driven, 3 HP electric motor, 3 phase,50c/s, AC supply, The pump set shall be capable to delever 485 LPM at 11 mtr head having 2900 RPM including fixing arrangements in PVC tank 10000 litr/RCC chamber as required or directed all pipe connection of motar and foot valve with MS canopy for motar protection. The Pump and motar shall be of same make :Kirloskar or equivalant modal in make complete all as specified and directed.\n | | 4 | Each set |
|---|
| 17 | 17 | Earthing complete with galvanised iron earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of the plate not less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire welded and rivetted to earth plate at one end connected to main DBs of Bldg at another end GI earth strip encased in and including 15 mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm dia GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 and precast RCC pit cover 50mm thick in RCC 1;2;4 type B-I duly reinforeced with MS bars 8mm dia @ 150C/C with both wayswith lifting handle including excavation & earth work in any type of soil & removal of surplus soil upto 50 mtr complete all as shown in electrical plate no 5 of SSR part-I (2009) complete all as specified and as directed.\nNotes :- (1) Earth lead and GI pipe light grade 32 mm dia for protection against mechanical damage beyond 7.5 mtr from electrode to earth terminal point/main switch board etc shall be measured separately.\n(2) On testing, after completion of Job , if desired earth resistance is not obtained, the earthing shall be redone at no extra cost to Govt. | | 6 | Each set |
|---|
| 18 | 18 | Supplying and laying of 40 mm bore UPVC pipes of pressure rating 10kgf/Cm2, fixed complete to wall, ceiling or in floor, complete with all all fittings and jointing materials, complete all as specified and directed. | | 1400 | RM |
|---|
| 19 | 19 | Supplying and laying of 25 mm bore UPVC pipes of pressure rating 10kgf/Cm2, fixed complete to wall, ceiling or in floor, complete with all all fittings and jointing materials, complete all as specified and directed. | | 600 | RM |
|---|
| 20 | 20 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables, pipe lines etc not exc 10 Sqm on plan and getting out in any type of soil, complete all as specified and directed. | | 400 | Cum |
|---|
| 21 | 21 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 Cm in hard/dense soil complete all as specified and directed. | | 360 | Cum |
|---|
| 22 | 22 | M&L for dry and fine river sand free from sharp material as in cushioning to cable in trenches for cable protection including necessary punning and consolidation as required complete all as specified and as directed. (Depth of sand shall be measured after punning). | | 30 | Cum |
|---|
| 23 | 23 | Supply and laying well burnt old size sub class 'B' bricks as protection to underground cables, laid dry and flat adjoining each other, complete all as specified and directed. | | 2550 | Each |
|---|
| 24 | 24 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed. | | 40 | Cum |
|---|
| 25 | 25 | S&F Gun metal gate or globe valve with iron wheel head, screwed both ends for 40 mm bore iron pipe complete all as specified and directed. | | 12 | Each |
|---|
| 26 | 26 | S&F Gun metal gate or globe valve with iron wheel head, screwed both ends for 25 mm bore iron pipe complete all as specified and directed. | | 16 | Each |
|---|
| 27 | 27 | Supply, fixing and testing cast iron non return valve ISI marked, heavy duty conforming to IS 5312/2004 of size 40 mm bore with flanged jointing on both ends, including jointing materials such as rubber/fibre board gasket, bolts, nuts and twin washers, complete all as specified and directed. | | 2 | Each |
|---|
| 28 | 28 | S&F Rotational moulded polyethylene water storage tank ( cylindrical vertical with closed top) hosted and fixed in position all as specified and as directed of capacity 10000 Ltrs complete all as specified and directed. | | 2 | Each |
|---|