Military Engineer Services-MES has published Provision Of Certain Lbw Works At Itarana Alwar. Submission Date for this Tender is 18-07-2020. Civil Work Tenders in Alwar Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 29-Jun-2020 | DATE CORRIGENDUM | Date | 11-07-2020 |
2 | 03-Jul-2020 | BOQ Corrigendum | BOQ | 11-07-2020 |
3 | 11-Jul-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 18-07-2020 |
Name of Work : PROVN OF CERTAIN LBW WORKS AT ITARANA ALWAR | |||||
---|---|---|---|---|---|
Srl. No. | Item Description | Item Code / Make | Approx No of units reqd | Units | |
1 | 1 | B/R ITEMS\nExcavation in trenches, n exc 1.50 m wide and n exc 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in soft/loose soil, complete all as specified and directed | 110.92 | Cubic Metre | |
2 | 2 | Earth filling under floors including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 42.7 | Cubic Metre | |
3 | 3 | Surface dressing n exc 15 cm deep in soft/ loose soil, complete all as specified and directed. | 150 | Square Metre | |
4 | 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 44.56 | Cubic Metre | |
5 | 5 | Removing excavated surplus material (Soils) to a distance exceeding 500 mtr but n exc. 1000 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 32.1 | Cubic Metre | |
6 | 6 | Removing excavated surplus material (Soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 289.66 | Cubic Metre | |
7 | 7 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loosed soil complete all as specified and directed. | 284 | Square Metre | |
8 | 8 | Removing excavated surplus material to a distance exceeding 50m and n exc. 1.5m depositing where directed above the starting point complete all as specified and directed. | 16.5 | Cubic Metre | |
9 | 9 | Excavation over areas n. exc 1.5 mtr deep in soft/loose soil and getting out complete all as specified and direct. | 250 | Cubic Metre | |
10 | 10 | M & L for moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed. | 25.7 | Cubic\nMetre | |
11 | 11 | Excavating in post holes (or similar holes) each n exc 0.5 cu m getting out in soft/loose soil and removing surplus soil to a distance n exc. 50m complete all as specified and directed. | 129 | Each | |
12 | 12 | M & L treating the bottom and sides of excavation at the rate of 5 litres of Anti-Termite emulsion per square metre of surface area, complete all as specified and directed. | 60 | Square Metre | |
13 | 13 | M & L treating the backfill in contact with foundation at the rate of 7.5 litres of Anti-Termite emulsion per square metre of vertical surface complete all as specified and directed. | 102 | Square Metre | |
14 | 14 | M & L treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. | 198 | Square Metre | |
15 | 15 | M & L treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. | 78.4 | Square Metre | |
16 | 16 | M&L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered & rammed to true surface complete all as specified and directed. | 172.14 | Cubic Metre | |
17 | 17 | S & F factory made steel windows, box type, any size (XW2, M/F) double shutter on openable shutter with glazing bars and other openable shutter without glazing bars, fabricated with members of standard size as shown on drawing including frames, complete all as specified and directed.\nNote:- The quoted rates shall be deemed of lugs and FI required for fixing, wire cloth, sheet glass, Grills, iron mongry and guard bars as shown on drg and applying two coats of synthetic enamel paint over a coat of red oxide primer, | 11 | Square Metre | |
18 | 18 | S & F hand rails, half round or other stock section or core for wooden hand rail stright portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and srewing etc. wind ties for roof including securing bolt posts and struts in encing including cutting tps to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (For securing wire mesh etc) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. | 2990 | Kilogram | |
19 | 19 | S&F mild steel framed work conforming to Fe 290 Gde E-165 for such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, frames guard bars, barred iron doors, framed for opening of man holes etc and similar class complete all as specified and directed. | 250 | Kilogram | |
20 | 20 | S&F 35mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed by Engineer-in-Charge.\n(Note :- S & F Glass/gauge shall be measured and paid for separately) | 4 | Square Metre | |
21 | 21 | Supply, and laying of sand including spreading, levelling and ramming in layers n exc. 25cm thick in each layer, complete all as specified and directed. | 4.1 | Cubic Metre | |
22 | 22 | M&L for laying 60mm thickness machine pressed precast concrete glazed coloured interlocking paver block with any shape and size confirming to IS 15658-2006 M-35 grade grey cement and pigment over and including 25mm thick sand cushioning complete all as specified & directed. \nNote:- Sand cushioning will measured and paid seperately. | 174 | Square Metre | |
23 | 23 | M & L for cement concrete work in pavement/ hardstanding of flexural strength 40 kg/per sq cm in field using minimum 400 kg of cement per cubic metre, thickenss of concrete shall be 100mm finished the surface even and fair complete all as specified and directed. | 140 | Running Metre | |
24 | 24 | S&F in repairs 19/20mm thick block board grade-1 quality exterior grade decorative veneer on both faces and alround covered with 6mm thick teak wood beading/lipping fixed with screwed to timber frame complete all as specified and directed. | 2.88 | Square Metre | |
25 | 25 | S & F aluminium (Extruded section) body, door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850mm in width and of weight between 61 to 80 Kg and fixed complete all as directed. | 2 | Each | |
26 | 26 | S & F 100 mm size butt hinges, cold rolled mild steel, medium weight, ISI marked complete all as specified and directed. | 6 | EACH | |
27 | 27 | S & F for mortice lock brass body, vertical type size 100mm, 4 lever type, complete all as specified and directed. | 1 | EACH | |
28 | 28 | S&F 250mm long mild steel sliding door bolts, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, 04 on bolt plate and 02 on staple plate and fix complete all as specified and directed by Engineer-in-Charge. | 2 | EACH | |
29 | 29 | S & F 200mm long mild steel barrel tower bolt stove enamelled black with bright bolt and fixed , complete all as specified and directed. | 4 | EACH | |
30 | 30 | S & F Harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and directed. | 18 | Running Metre | |
31 | 31 | S & F 150mm mild steel barrel pressed handle, oval type, stove enamelled black, complete all as specified and directed. | 4 | EACH | |
32 | 32 | S & F stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as directed. | 4.84 | Square Metre | |
33 | 33 | S & F 3mm thick sheet glass ordinary quality and glazing with rubber bedding in squares not exc. 0.5 Sqm in each pane complete all specified and as directed. | 12.56 | Square Metre | |
34 | 34 | S & F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.)complete all as specified and directed. | 14.52 | Square Metre | |
35 | 35 | S & F anodised aluminium door shutters, aluminium section weighting 0.55 kg/ m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. | 5.04 | Square Metre | |
36 | 36 | S & F aluminium powder coated frame in any positiion such as door frame, grills, guard bars etc. members made out of extruded Aluminium of any section and in any positiion including fixing clips and provision of roller for fixing of prelaminated particle board, complete all as specified and directed. | 40 | Kilogram | |
37 | 37 | M & L for PCC 1:2:4, type B-0, using 12.5mm broken stone graded aggregate as krbs, copings, kneelers, bed plates, etc. including all necessary form work, complete all as specified and directed. | 1 | Cubic\nMetre | |
38 | 38 | M&L providing precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) set in CM 1:6, rounded or chamfered as in kerb stone with solid blocks, exc. 10 cm in width and simiar articles complete all as specified and directed. | 6.43 | Cubic\nMetre | |
39 | 39 | M&L for 100 mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base of flooring finished surface even and rough complete all as specified and directed. | 1622 | Square Metre | |
40 | 40 | M&L for 70 mm thick PCC type B-1, 1:2:4 (using 40mm graded stone aggregate) as in sub base of flooring finished surface even and rough complete all as specified and directed. | 118 | Square Metre | |
41 | 41 | M&L for PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. | 81.53 | Square Metre | |
42 | 42 | M&L for Plastic Dividing strips, 38mm x 1.5mm thick complete all as specified and directed. | 70 | Running Metre | |
43 | 43 | Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batten for rough finished surfaces of concrete complete all as specified and directed. | 140.4 | Square Metre | |
44 | 44 | Use and waste of flat formwork to sides of pillars, posts, struts, piers,columns and stanchions for rough finished surfaces of concrete square rectangular or polygonal complete all as specified and directed. | 137.08 | Square Metre | |
45 | 45 | Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete complete all as specified and directed. | 162.32 | Square Metre | |
46 | 46 | M & L form work to edges of concrete flats, treads, breaks in floors, windows cills, concrete railings, floor and roof n exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work ewxc 10 cm but n exc. 20 cm wide compelte all as specified and directed. | 240 | Square Metre | |
47 | 47 | Use and waste of flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n exc. 200mm thick flat rough finished surfaces of concrete complete all as specified and directed. | 240.57 | Square Metre | |
48 | 48 | M & L for use and waste for formwork to sides and soffits of chajjas for fair finished surfaces complete all as specified and directed. | 11.48 | Square Metre | |
49 | 49 | M & L forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compond Grade 'A' thickness of concrete slab 100mm complete all as specified and directed. | 6 | Ten Running Metre | |
50 | 50 | M & L for forming contraction joints 100mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed. | 35 | Ten Running Metre | |
51 | 51 | M & L for forming contraction joints (Dummy) 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed. | 35 | Ten Running Metre | |
52 | 52 | M&L for Reinforced cement concrete Design Mix M-25 using 20mm graded stone aggregate as in foundations including rafts, footings, foundations beams, plinth beams, bases for columns ect, basement slabs, under reamed piles and mass concrete complete all as specified and directed. | 32.31 | Cubic Metre | |
53 | 53 | M&L for Reinforced cement concrete Design Mix M-25 using 20mm graded stone aggregate as in for beams, cantilevers, bresummers and lintels over 1.5 m span complete all as specified and directed. | 19.97 | Cubic Metre | |
54 | 54 | M&L for Reinforced cement concrete Design Mix M-25 using 20mm graded stone aggregate as in columns, pillars piers, posts & struts etc complete all as specified and directed. | 13.32 | Cubic Metre | |
55 | 55 | M&L for Reinforced cement concrete Design Mix M-25 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roof etc. complete all as specified and directed. | 35.15 | Cubic Metre | |
56 | 56 | M&L for Reinforced cement concrete Design Mix M-25 using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed. | 1.27 | Cubic Metre | |
57 | 57 | M & L for reinforcement TMT bars 6 to 8 mm mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. | 1560 | Kilogram | |
58 | 58 | M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. | 5125 | Kilogram | |
59 | 59 | M & L for TMT bars 5 mm dia and over upto and including 8mm dia in strrups spacers and binders quality conforming to TMT bar, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. | 1470 | Kilogram | |
60 | 60 | S & F mild steel screw bolts (Machine made) with hexagonal or square heads at one ebd and the screwed the other to be fitted with washers and one hexagonal or square but exc 5cm but n. exc. 0 cm long, dia of shank 5 to 10mm, complete all as specified and directed. | 30 | Kilogram | |
61 | 61 | Supply only chain link MS ganvanised fencing, any size or type (weight not less than 3.00 kg/sqm) complete all as specified and directed. | 1940 | Kilogram | |
62 | 62 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. | 630 | Square Metre | |
63 | 63 | S&F for galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain-ing bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete all as specified and directed. | 21 | 100 Running Metre | |
64 | 64 | M & L for treating ends of posts, backs of chowkhats etc. area tarred exc. 0.1 sqm but n. exc. 0.5 sqm each complete all as specified and directed. | 1.29 | Per 100 Nos | |
65 | 65 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. | 77.5 | Cubic Metre | |
66 | 66 | M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc. 10 mm over UG cable for protection and complete all as specified and directed. | 0.9 | Per 1000 Nos | |
67 | 67 | M&L for 20mm Damp Proof Course to horizontal or vertical surfaces including necessary formwork in CM 1:2 complete all as specified and directed. | 14.7 | Square Metre | |
68 | 68 | M&L for dry sand and punning for cushioning to under ground cable complete all as specified and directed.\nNote :- For the purpose of payment only punned thickness shall be measured. | 10.53 | Cubic Metre | |
69 | 69 | M & L for cement concrete type C-2 1:3:6 using 40mm graded stone aggregate as in foundation filling and mass concrete in fixing of fencing post including necessary form work if required at site, complete all as specified and directed. | 10 | Cubic Metre | |
70 | 70 | M & L for 50mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed. | 78.4 | Square Metre | |
71 | 71 | M & L for machine cut Kota stone slab 20 to 25mm thick size not less than 22" x 22" as in floor laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. | 84 | Square Metre | |
72 | 72 | M & L for 20-25mm thick machine cut Kota stone as in riser such as steps, skirting, dado and pillar set etc over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including10mm thick cement plaster in CM (1:4) on other than fair faces of brick work of stone surfaces of walls complete all as specified and directed. | 12 | Square Metre | |
73 | 73 | M & L for 10mm thick rendering internal surfaces in CM 1:6 on fair faces of brick work or surfaces of walls, finished even and fair without using extra cement, complete all as specified and directed. | 141.72 | Square Metre | |
74 | 74 | M&L for rendering 5 mm thick in cement mortar 1:3 as in ceiling, (Sunshed & chajja etc.) and finished even and smooth without using extra cement complete all as specified and directed. | 262.87 | Square Metre | |
75 | 75 | M&L for rendering 5 mm thick in cement mortar 1:3 as in columns, sides of beams and finished surfaces even and smooth without using extra cement complete all as specified and directed. | 10 | Square Metre | |
76 | 76 | M&L 15mm thick rendering in cement mortar 1:4, mixed with water proofing compound finished with even and smooth mixed with liquid proofing admixture complete all as specified and directed. \nNote : Water proofing Admixture shall be measured and paid separately. | 359.57 | Square Metre | |
77 | 77 | M&L screed bed 15mm thick in cement mortar 1:4 mixed with water proofing Admixture as per manufacture instructions on concrete surfaces of roof slab finishing the surfaces even and smooth complete all as specified and directed. \nNote:- WPA shall be measured and paid separately under relevant item of this Schedule. | 248.57 | Square Metre | |
78 | 78 | Supply only liquid water proofing Admixture complete all as specified and directed. | 21 | Ltr | |
79 | 79 | Peparation of new steel surfaces and iron surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete alcomplete all as specified and directed. | 110 | Square Metre | |
80 | 80 | Peparation of new steel surfaces and iron surfaces of any description not otherwise described but not exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete alcomplete all as specified and directed. | 90 | 10 Running Metre | |
81 | 81 | Preparation of old or previously treated wooden or wood based surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved shade complete all as specified and directed. | 10 | Square Metre | |
82 | 82 | Preparing newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed. | 262.87 | Square Metre | |
83 | 83 | M & L for applying 3 mm thick wate care putty in two layers on newly plastered surface of wall to archieve smooth, complete all as specified and directed. | 147.72 | Square Metre | |
84 | 84 | M & L for applying 1-2 mm thick wate care putty in two layers on newly plastered surface of wall to archieve smooth, complete all as specified and directed. | 170 | Square Metre | |
85 | 85 | M &L preparing newly plasrtered surfaces of walls and apllying two coats of cement based paint over a coat of water primer, complete all as specified and directed. | 369.57 | Square Metre | |
86 | 86 | Preparation of newly plastered surfaces of wall and applying two coats of distemper oil emulsion over one coat of alkali resistant primer complete all as specified and directed. | 311.72 | Square Metre | |
87 | 87 | Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydro Stop manufactured by TIKITAR DANOSA (INDIA) Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete all as directed.\nNote: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied@1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. \n(ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. \n(iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. \n(iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen.\n(v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. \n(vi) Above aspects are deemed to be included in quoted rate. | 250.57 | Square Metre | |
88 | 88 | E/M PORTION \nM & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping double locked box type with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash thru fasteners with cadmium plated screws all as per IS with MS concealed terminal boxes (Heavy duty) with 3mm thick plastic laminated bakelite (Hylam) sheet top cover for mounting switches, sockets, regulators, bell push etc, including 1.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly for the following :- | |||
89 | 88.1 | One light point controlled by one, one way switch. | 36 | Per\nPoint | |
90 | 88.2 | One fan point controlled by one switch and regulator. | 4 | Per\nPoint | |
91 | 88.3 | One 3 pin, 5/6 Amps socket outlet controlled by one 5/6 Amp switch on same board. | 12 | Per\nPoint | |
92 | 88.4 | One 3 pin, 5/6 Amps socket outlet controlled by one 5/6 Amp switch on independent board. | 6 | Per\nPoint | |
93 | 89 | M & L for point wiring complete for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on indepdent board with 2.50 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping double locked box type with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash thru fasteners with cadmium plated screws all as per ISS with MS concealed terminal boxes (Heavy duty) with 3mm thick plastic laminated bakelite (Hylam) sheet top cover for mounting switches, sockets, including 2.50 Sq.mm multistranded copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly. | 12 | Per\nPoint | |
94 | 90 | S & F switch piano flush type 5/6 Amps, single pole, one way, 230 Volts complete all as specified and directed. | 8 | EACH | |
95 | 91 | S & F switch piano, flush type single pole, one way 15 Amp, 230 Volts complete all as specified & directed. | 12 | EACH | |
96 | 92 | S & F socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts complete all as specified & directed. | 12 | EACH | |
97 | 93 | S & F socket outlet two-in-one, 3 pin, 5 Amp and 15 Amp, flush type, 240 Volts complete all as specified & directed. | 12 | EACH | |
98 | 94 | S & F ceiling rose, surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed. | 46 | EACH | |
99 | 95 | S & F electronic stepped type fan regulator, flush type, connecting up, ISI marked, complete all as specified and directed. | 4 | EACH | |
100 | 96 | S & F Ceiling Fan complete of 1200mm sweep 240 V AC including provision of hooke in ceiling of suitable size including necessary electric connections, complete all as specified and directed. | 4 | Each | |
101 | 97 | S&F decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 16W to 20W with LED tube of model E-LITE LED pride and connecting up with the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. \nMake :- Havelles Cat Part No LHEXBHP71N1W018 or equivalent as specified in Appendix 'D'. | 34 | Each | |
102 | 98 | S & F sheet metal enclosure single door DB SPN 04 way, 240volts protection class IP-30 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity complete all as specified and directed. | 2 | EACH | |
103 | 99 | S & F MCB SPN 63 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I, complete, all as specified & directed. | 3 | EACH | |
104 | 100 | S & F MCB SP 6 to 32 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I, complete, all as specified & directed. | 24 | EACH | |
105 | 101 | S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS cable 1100 Volt grade with 06 Sqmm copper multistranded conductor drawn through and including PVC conduit 25mm bore fixed on surface to wall/ ceiling by means of MS screws and saddles including one run of 6 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.\nNote: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only. | 13 | Running Metre | |
106 | 102 | Supply and fixing in repair LED street light fitting 20 Watt 230 V, 50 Hz DRACO Series , lightand connecting the fitting from using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed.\nMake & Model :- Cat Part No LTESS20WLED of make C & S or equivalent model of make as specified in Appendix 'D'. | 4 | EACH | |
107 | 103 | M &L for 40mm bore GI Pipe (Light grade) for protection of LT cable fixed to walls/ poles/ road crossing including clamps complete all as specified and directed. | 20 | Running Metre | |
108 | 104 | Supply and Laying/ fixing, jointing, testing and commissioning of 35sqmm 3.5 core LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts, through pipe, under floors or roads/ pipes/fixed on walls/poles including taking down old unserviceable cable complete all as specified and directed.\nNote :- \n(i) Sand cushioning, cable protection, GI pipe for protection and excavation & earth work shall be measured & paid for separately.\n(ii) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions. | 130 | Running Metre | |
109 | 105 | S & F second class hardwood rectangular block open recessed of size 45cm x 30cm x 5 cm depth with 3 mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos) complete all as directed. | 2 | Each | |
110 | 106 | Supply and install single phase hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2.0 TR complete all as specified and directed. | 1 | Cubic\nMetre | |
111 | 107 | S & F single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 Volts, 32 Amps, complete all as specified and directed. | 1 | EACH | |
112 | 108 | S & F wall mounted indoor voltage stabilizer automatic operation single phase and designed for inpur variation between 170 V to 250 volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 5 KVA, complete all as specified and directed. | 1 | EACH | |
113 | 109 | M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6.3 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed.\nNote : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. \n(ii) The cost of excavation, earth work is included in the quoted rate. | 4 | Each\nJob |