| 1 | 1 | Dismantling of ACSR conductor complete all as specified and as directed by the Engineer-in-Charge. | | 11 | Quintal |
|---|
| 2 | 2 | Dismantling of insulators any type, any size complete all as specified and as directed by the Engineer-in-Charge. | | 100 | Each |
|---|
| 3 | 3 | Dismantling of stay assembly complete all as specified and as directed by the Engineer-in-Charge. | | 15 | Per Set |
|---|
| 4 | 4 | Dismantling of cross arms of MS channel or angle sections etc. complete all as specified and as directed by the Engineer-in-Charge. | | 8 | Quintal |
|---|
| 5 | 5 | Excavation in trenches n. exc. 1.5m in width and n. exc. 1.5m in depth and getting out in soft/loose soil from the trenches complete all as specified and as directed by the Engineer-in-Charge. | | 489 | Cum |
|---|
| 6 | 6 | Returning, filling in including spreading, leveling and well ramming in layers n. exc. 25cm in thick complete all as specified and as directed by the Engineer-in-Charge. | | 250 | Cum |
|---|
| 7 | 7 | Removal of surplus soil to a distance n. exc. 50m away and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge. | | 239 | Cum |
|---|
| 8 | 8 | Supply and spread clean dry river sand in cable trenches for providing cushioning for the cable complete all as specified and as directed by the Engineer-in-Charge.\nNote: Only punned thickness will be measured for the purpose of payment. | | 175 | Cum |
|---|
| 9 | 9 | Supply and lay fly ash building bricks of sze 200x100x80mm for cable protection complete all as specified and as directed by the Engineer-in-Charge. | | 21756 | Each |
|---|
| 10 | 10 | Cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6, type C1 (Using 20mm graded aggregate) complete all as specified complete all as specified and directed. | | 30 | RM |
|---|
| 11 | 11 | Supply and lay GI tubing 50mm dia. light grade for cable protection and sealing the pipe both ends with sealing compound complete all as specified and as directed by the Engineer-in-Charge. | | 20 | RM |
|---|
| 12 | 12 | Supply and laying LT underground cable XLPE insulated and sheathed armoured electric power cable (Heavy duty) 1100 Volts grade, 2 core 10 Sq.mm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. | | 151 | RM |
|---|
| 13 | 13 | Supply and laying LT underground cable XLPE insulated and sheathed armoured electric power cable (Heavy duty)1100 Volts grade, 4 core 6 Sq.mm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. | | 101 | RM |
|---|
| 14 | 14 | Supply and laying LT underground cable XLPE insulated and sheathed armoured electric power cable (Heavy duty)1100 Volts grade, 4 core 10 Sq.mm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. | | 601 | RM |
|---|
| 15 | 15 | Supply and laying LT underground cable XLPE insulated and sheathed armoured electric power cable (Heavy duty)1100 Volts grade, 4 core 16 Sq.mm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. | | 801 | RM |
|---|
| 16 | 16 | Supply and laying LT underground cable XLPE insulated and sheathed armoured electric power cable (Heavy duty)1100 Volts grade, 4 core 25 Sq.mm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. | | 181 | RM |
|---|
| 17 | 17 | Supply and laying LT underground cable XLPE insulated and sheathed armoured electric power cable (Heavy duty)1100 Volts grade, 3 ½ core 50 Sq.mm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. | | 501 | RM |
|---|
| 18 | 18 | Supply and laying LT underground cable XLPE insulated and sheathed armoured electric power cable (Heavy duty)1100 Volts grade, 3 ½ core 70 Sq.mm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and as directed by the Engineer-in-Charge. | | 101 | RM |
|---|
| 19 | 19 | S&F HOT moulded (FRP) junction box for street light pole with locking arrangement with IP -65 protection of size 185 x 165 x 60 mm with 32 Amp 4 way heavy duty terminal block with 10 Amp MCB SP and two steel bracket to fix with pole and aluminium bus bar of rating 200 Amps complete all as specified and directed by Engineer-in-Charge. | | 54 | Each |
|---|
| 20 | 20 | S&F PVC insulated, PVC sheathed cable with stranded copper conductor of size 1.5 sq mm , 3 core, 1100 Volts grade through rigid PVC 25mm conduit pipe with proper clamping to poles complete all as specified and directed by Engineer - in - Charge. Note:- Rate quoted is inclusive of PVC conduit pipe. | | 405 | RM |
|---|
| 21 | 21 | S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3½/4 core XLPE, armoured, aluminium conductor cable of size 25 to 50 Sqmm, indoor/ outdoor type complete all as specified and as directed by the Engineer-in-Charge. | | 10 | Each |
|---|
| 22 | 22 | S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3½/4 core XLPE, armoured, aluminium conductor cable of size 70 to 95 Sqmm, indoor/ outdoor type complete all as specified and as directed by the Engineer-in-Charge. | | 6 | Each |
|---|
| 23 | 23 | M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (Earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing with Poles, DBs and machineries all as specified including earth work and excavation in any type of soil, PCC 1:3:6, type C1 chamber & RCC 1:2:4, type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and directed and testing on completion. | | 9 | Each \nJob |
|---|
| 24 | 24 | S&F Digital time switches Timlite DB 32 Amps 3 pole/ 230 V with prewired all accessories and fitted inside steel enclosure complete all as specified and directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 25 | 25 | Dismantling of 09 m long poles with all fittings and deposited to E/M store yard complete all as specified and directed by Engineer-in-Charge. | | 3 | Each |
|---|
| 26 | 26 | Supply and installed hi wall split unit indoor/out door single phase driven at 230 Volts and 50Hz frequency complete with cordless remote control unit and with in built air ioniser and plasma filter for batter indoor air quality control with minimum 4 star rating as per BEE and having ISEER not less than 3.5 capacity 2 ton working on rotary compressor and copper condensor with outdoor stand/bracket including drain pipe line AC indoor unit to ground level complete all as specified and as directed by the Engineer-in-Charge. Note: - Minimum warranty on compressor shall not be less than 05 years and the warranty certificate shall be submitted along with paid voucher. | | 8 | Each |
|---|
| 27 | 27 | S&F voltage stabilizer for automatic operation single phase naturally air cooled indoor type & desigened for input variation between 150 Volts to 285 Volts with output voltage stabilizer 230 Volts with accuracy of +2.5 % and capacity of 5 KVA complete all as specified and as directed by the Engineer-in-Charge. Note: - Minimum warranty voltage stabilizer shall not be less than 03 years and the warranty certificate shall be submitted along with paid voucher. | | 8 | Each |
|---|
| 28 | 28 | S&F single pole and neutral sheet metal enclosures with a two pin and earth plug and socket 240 V, 50 HZ complete with one single pole MCB 20 A suitable for split/window type ACs complete all as specified and as directed by the Engineer-in-Charge. | | 8 | Each |
|---|
| 29 | 29 | M&L for concealed point wiring PVC insulated and unsheathed cable with two runs of 4 Sq.mm FRLS copper conductor single core multi strand 1100 Volts grade drawn through PVC conduit of suitable size and concealed metal box including one run of 4 Sq.mm earth wire copper insulated wire connected to common earth dolly for 6/16 Amps socket and AC power socket complete all as specified and as directed by the Engineer-in-Charge. | | 8 | Point |
|---|
| 30 | 30 | M&L for sub main wiring, surface, with two runs of 6 Sq.mm. PVC insulated unsheathed FRLS copper conductor single core multi stranded and one run of insulated copper earth wire 6 Sq.mm. drawn through PVC casing and capping or recessed as per site requirement of suitable size complete all as specified and as directed by the Engineer-in-Charge. | | 40 | RM |
|---|
| 31 | 31 | S&F MCCB 3 pole, 415 V, fixed type,100 Amps with 16 KA breaking capacity complete all as specified and as directed by the Engineer- in-Charge. | | 1 | Each |
|---|