Special Repairs To Building No 126 Depot Coy And Other Sanctioned Work At 14 Gtc Subathu
Tender Overview
Project Description
Special Repairs To Building No 126 Depot Coy And Other Sanctioned Work At 14 Gtc Subathu
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-Jul-2020 |
BOQ
| Name of Work: SPL REPAIR TO BLDG NO. 126 (DEPOT COY) AND OTHER SANCTIONED WORK AT 14 GTC SUBATHU | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 0.01 | Schedule 'A' Section - I | |||
| 2 | 1 | Demolition of cement concrete (un re-inforced) in ground floor and paving n.exc. 15 cm thick below or above ground level complete all as specified . | 3 | Cum | |
| 3 | 2 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) | 0.52 | Cum | |
| 4 | 3 | Taking down cement plaster on brick wall surfaces etc incl raking out joints hacking for key, scrubing down with water etc cpmplete all as specified and as directed | 350 | Sqm | |
| 5 | 4 | Taking down Shutters of any description n exc 1 sq. m each cpmplete all as specified and as directed | 40 | Per Leaf | |
| 6 | 5 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish off the premises complete all as specified. | 350 | Sqm | |
| 7 | 6 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar. | 1.15 | X Sqm | |
| 8 | 7 | Demolition of brick work or stone boulder masonry built in cement mortar complete all as spd and as directed. | 3.5 | Cum | |
| 9 | 8 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified. | 4 | Each | |
| 10 | 9 | Surface dressing in Hard/dense soil n exc 15 cm deep complete all as specified. | 98.06 | Sqm | |
| 11 | 10 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed. | 0.5778 | Cum | |
| 12 | 11 | Removing excavated material to a distance n.exc 50m and deposited where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed | 16.3407 | Cum | |
| 13 | 12 | M&L for PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. | 1.4859 | Cum | |
| 14 | 13 | Material and labour for brick work with sub class ‘B’ bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. | 12.0652 | Cum | |
| 15 | 14 | Material and labour for loose filling with broken bricks aggregate of gauge 80 mm to 150mm in soakage pits etc. complete all as specified. | 3.285 | Cum | |
| 16 | 15 | Material & labour for rendering 15mm thick on fair faces of brick masonry surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified. | 37.24 | Sqm | |
| 17 | 16 | Material & labour for rendering 5mm thick on ceiling surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified. | 10.95 | Sqm | |
| 18 | 17 | Material & labour for rendering 15mm thick on other than fair faces of brick masonry surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified. | 42.56 | Sqm | |
| 19 | 18 | M&L preparation of newly plastered or unplastered or previously untreated surfaces of walls and applying two coats of cement base paint complete all as specified. | 42.56 | Sqm | |
| 20 | 19 | M&L for preparation of plastered or unplastered new surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stoping the connected previously treated surfaces and applying two coat of oil emulsion distemper (tint as approved by GE) complete all as specified & directed. | 398.19 | Sqm | |
| 21 | 20 | M & L damp proof coarse to horizontal or vertical surfaces in plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone agg), 40 mm thick including necessary form work, mixed with water proofing compound over and including a bitumen layer @ 1.2 kg per sqm (Supply only water proofing compound shall be measured and paid for saparately) complete all as spfd and directed. | 3.059 | Sqm | |
| 22 | 21 | M&L for 75mm thick cement concrete type D-2,1:4:8 (40mm graded stone aggt) as in sub base concrete all as spfd. | 105.95 | Sqm | |
| 23 | 22 | Material and labour for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. | 10.2 | Sqm | |
| 24 | 23 | Material and labour for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in verticle surface/dado,skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge. | 1.33 | Sqm | |
| 25 | 24 | S&F Flush shutters,30mm thickness solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & directed. | 2.1 | Sqm | |
| 26 | 25 | M&L for 2nd class hard wood as in plain, solid, straight chawkhats and frames, wrought framed rebated on the solid, rounded or chamfered , put to gather with glue pinned at joints complete all as specified. | 0.034 | Cum | |
| 27 | 26 | S&F steel windows with side hung shutters including projecting type hinges with steel handle , and steel peg stay , complete with glazing bars , dovetailed or welded complete all as specified & diretced | 2.4 | Sqm | |
| 28 | 27 | _Ditto_ but without glazing bars | 2.4 | Sqm | |
| 29 | 28 | S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. | 0.72 | Sqm | |
| 30 | 29 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and / or riveted, or forged into spikes , framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings , framework of water tanks and similar work conforming to Fe 290 Gde E-165 | 30 | Kg | |
| 31 | 30 | Supply only galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specifeid | 2 | Sqm | |
| 32 | 31 | Supply only sheet glass , ordinary quality & glazing 3mm thick, with oil putty in square n. Exc 0.5 Sqm in each pane complete all as specified & as diretced | 2 | Sqm | |
| 33 | 32 | M&L Reinforced cement concrete (nominal mix) type B0 1:2:4 (12.5mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.\n | 0.432 | Cum | |
| 34 | 33 | M&L Reinforced cement concrete (nominal mix) type B0 1:2:4 (12.5mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified and as directed.\n\n | 0.80408 | Cum | |
| 35 | 34 | M&L Reinforced cement concrete (nominal mix) type B0 1:2:4 (12.5mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.\n\n | 1.37655 | Cum | |
| 36 | 35 | M&L Reinforced cement concrete (nominal mix) type B0 1:2:4 (12.5mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.\n\n | 1.836 | Cum | |
| 37 | 36 | M & L for mild steel TMT Bars 10mm dia and over cut to length, bend to shape required, incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and incl MS wire (Annealed) not less than 0.9mm dia or securing with clips complete all as specified. | 470 | Kg | |
| 38 | 37 | All as per serial item No. 36 here in before but 5mm dia & over upto and including 10mm dia in stirrups, spacers and binders, -ditto- | 70 | Kg | |
| 39 | 38 | M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified. | 2.88 | Sqm | |
| 40 | 39 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified. | 15.3 | Sqm | |
| 41 | 40 | M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified. | 13.984 | Sqm | |
| 42 | 41 | M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified. | 7.98 | Sqm | |
| 43 | 42 | M & L Preparation of new or previously untreated surfaces of wood or based materials of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. | 4.62 | Sqm | |
| 44 | 43 | Material & labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint (1st quality) over a coat of red-oxide primer complete all as specified & directed. | 4.8 | Sqm | |
| 45 | 44 | M&L for 50 mm thick plain cement concrete C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection finished fair and even without using extra cement complete all as spd & directed. \nNote:- The plinth protection shall be laid in pannels and length of the each panel shall not be more than 2.00 mtr all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item. | 89 | Sqm | |
| 46 | 45 | M&L Sand filling under interlocking coloured paver block average 25mm thick complete all as specified and as directed. | 2.4 | Cum | |
| 47 | 46 | M&L machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement & no pigment complete all as specified and as directed. | 95 | Sqm | |
| 48 | 47 | M & L for Plain Cement concrete type B-1 (1:2:4) using 20mm graded crushed stone aggregate as in side edge packing of paver block, bed plates, hold fasts, plinth courses, filling in presserd steel frame and the like finished fair and even incl necessary form work complete all as spd. | 0.5 | Cum | |
| 49 | 48 | M & L Glazed Window/ Ventilator shutters, of 2nd class hard wood 25mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed. | 6 | Sqm | |
| 50 | 49 | Supply and fixing Mild steel butt hinges medium weight , clod rolled, 100mm, ISI marked, complete all as specified & directed. | 80 | Each | |
| 51 | 50 | Supply and fixing aluminium fabricated type extruded handles of size 75 mm complete all as specified & directed. | 40 | Each | |
| 52 | 51 | M&L rendeing 10mm thick other then fair faces surfaces in CM 1:4 finished even and smooth with out using extra cement (Internal surfaces) | 350 | Sqm | |
| 53 | 52 | M & L RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in shelves / slabs and like with and incl use and waste of necessary form work complete all as specified. | 0.52 | Cum | |
| 54 | 53 | PCC (1:3:6) type C2 using 40mm graded agg as in surface channel / drains. | 1 | Cum | |
| 55 | 54 | Extra for forming fair finished drain or channel 30 cm inner girth in forms, moulds/stopped ends etc. | 8 | RM | |
| 56 | 55 | M & L Non Skid coloured ceramic tiles 8 mm thick area exc 0.18sqm n exec 0.38 sqm in floors, set and jointed in neat cement slurry and pointed in white or colored cement to match with the tiles incl. 15mm thick screed bed or bedding layer in C.M 1:4 etc complete all as specified & as directed | 586 | Sqm | |
| 57 | 56 | All the same as per here-in-above but ceramic tiles of size on vertical surfaces such as skirting set and jointed in neat cement slurry and pointed in white or colored cement to match with the tiles incl. rendering 10mm thick in C.M 1:3 on brick work or concrete surfaces etc. complete all as specified & as directed | 40 | Sqm | |
| 58 | 57 | M&L for preparation of plastered or unplastered old decorated surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stoping the connected previously treated surfaces and applying two coats of oil emulsion distemper (tint as approved by GE) complete all as specified & directed. | 1248.25 | Sqm | |
| 59 | 58 | Material & labour for preparation of old painted wood or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified & directed. | 153.92 | Sqm | |
| 60 | 59 | Material & labour for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified & directed. | 125.17 | Sqm | |
| 61 | 60 | Perparing new Zinc (or galvanised) surface to receive painting, by coating with mordant solution including washing and cleaning and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. | 385 | Sqm | |
| 62 | 61 | M&L for preparation of brick wall surfaces and applying two coats of terracota complete all as specified. | 200 | Sqm | |
| 63 | 62 | M&L for Granite as in steps, pillars, window cills, cooking plateforms and like, 20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick cement screed bed in CM(1:6) complete all as specified. ( size of the slabs shalll not be less than 100cmx60cm ) Note:- (i) The rate of granite stone shall be deemed to incl for full rounded off corner/ edges incl all cutting to make it square or rectangular. (ii) The rate shall also be deemed to incl for cutting and polishing machine and granite polishing to achive the desired granite finish all as spfd. | 11.5 | Sqm | |
| 64 | 63 | Taking down carefully copper/AImn point wiring (Light,Fan/Point Socket or power) (fittings such as switches ceiling roeses, pendent, regulators, sockets etc to be measured & paid separately) & making good to disturbed surface of walls/floors etc. | 58 | Each Point | |
| 65 | 64 | M&L point wiring using approved colour coding as per IS with stranded FRLS copper conductor single core 1.5 Sqmm (Nominal area), PVC insulated cable in and incl PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.and with all connecting accessories incl mild steel sunken boxes suitable for mounting switch/sockets with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer incl mounting frame over cover plate, covered with 3mm thick plastic laminated sheet, incl PVC insulated FRLS copper conductor 1.5 Sqmm (Nominal area) single core PVC cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified. Note : Switch/sockets shall be measured and paid for separately :- (Make of cable :- Finolex/ Polycab/ Havells ) | |||
| 66 | 64.01 | One light point controlled by one switch | 35 | Each | |
| 67 | 64.02 | One switch socket outlet 3 pin,5 Amp on the independent board | 11 | Each | |
| 68 | 64.03 | One switch socket outlet 3 pin,5 Amp on same board | 4 | Each | |
| 69 | 65 | All as per item No 64 here-in-before but with 2 single core PVC insulated FRLS and sheathed copper conductor of size 2.5 Sqmm in and including PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.and with all connecting accessories with 2.5 Sqmm PVC insulated FRLS copper conductor as earth wire and connecting to common earth dolly for 6 pin 16 Amp socket outlet on the independent board.using 2.5 sqmm copper cable .(Make of cable :- Finolex/ Polycab/ Havells ) | 8 | Each Point | |
| 70 | 66 | S&F Lamp holder,PVC insulated body, with back plate suitable for batten fitting,ISI marked complete all as specified. | 8 | Each | |
| 71 | 67 | M& L switch piano, flush type, single pole 1 way 6 Amp,ISI marked complete all as specified. | 50 | Each | |
| 72 | 68 | S&F switch piano flush type, single pole 1 way 16 Amp, ISI marked complete all as specified. | 8 | Each | |
| 73 | 69 | M& L socket 5 pin 6 Amp piano flush type,ISI marked complete all as specified. | 15 | Each | |
| 74 | 70 | S&F socket out let 2 in one 6 pin 6 & 16 Amp, ISI marked complete all as specified. | 8 | Each | |
| 75 | 71 | S&F ceiling rose, 3 phase/ PVC/ polycorbonate,isolate bady, ISI marked complete all as specified. | 35 | Each | |
| 76 | 72 | S & F LED bulb 10 watt. | 8 | Each | |
| 77 | 73 | Supply and fixing Decorative box type fitting Pre-wired for and incl LED tube 18/20 watt 6000K 4 ft IP20 linear LED T8 tubular lamp with extruded aluminium/PC body and PC diffuser complete with inbuilt driver complete all as specified and directed. Make of fitting : Crompton Greaves cat part No. DMLN1LT8-16 or Havells cat part No. LHFXCEP1TN1W020 or Halonix cat part No HILB04—118 LED or Bajaj cat part No. BLRB DB 118.Make of tubelight: Make of LED tube : Crompton Greaves Cat part no. LT8-20-865-2 or Havells cat part No. LHFXCEP7U1W020 or Halonix Electra cat part No HLTLD – 04-20-WW or Bajaj cat part No. BLRB 18 CWC Note : Fitting,LED tube and driver will be of same make. | 15 | Each | |
| 78 | 74 | S & F LED Building security light 25 /30 watt pressure die cast housing with individuals LEDs & Lens with modular secondary optics and IP65 protection with electronics driver and copper conductor 3 core of 0.7 sqmm from ceiling rose to security light. Make: crompton greaves cat part No. LSTS-30-CDL or Havells cat part No. ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC or Bajaj cat part No. (BRLEP 25 W WH LED) & Haloniox cat part No. HLSLD-09-25-CWL-E-I | 4 | Each | |
| 79 | 75 | Supply and fixing wall Mounting LED fitting 9/10 watt 6000K 2 ft Basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver complete all as specified and directed. Make: Havells cat part No.LUMILINEBS9WLED865SPCWH or Bajaj product code 112407 BCLSB 10 WH or Halonix Flare plus cat part No HLB-03-10-CW-AL or CRompton greavescat part No. LCTL-9-CDL\nNote for Item No. 73 & 74 to75:Note:- \n(i) Make of the luminaire and driver shall be same.\n(ii) Lumen efficiency of the luminaire shall be minimum 100 Lumen / watt.\n(iii) Power factor of luminaire shall be minimum 0.95.\n(iv) Test cerificate (LM-79 & LM 80) and warranty certificate from the manufacturer should be submitted for records. | 16 | Each | |
| 80 | 76 | Supply & Fixing Bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bend to an angle of 120 degree with fixing arrangements on wall Complete all as in repair. | 4 | Each | |
| 81 | 77 | S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 4 way, 240 Volt SPN | 1 | Each | |
| 82 | 78 | S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 8 way, 240 Volt SPN | 2 | Each | |
| 83 | 79 | S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 4 way, 415 Volt TPN | 1 | Each | |
| 84 | 80 | S & F MCBs 'C' characteristics, Double pole , 240 V, 40 Amp breaking capacity 10 kA. Make: Legrand/ Havells/ Scheinder | 3 | Each | |
| 85 | 81 | S & F MCBs 'C' characteristics, Double pole , 240 V, 32 Amp breaking capacity 10 kA Make: Legrand/ Havells/ Scheinder | 3 | Each | |
| 86 | 82 | S & F MCBs 'C' characteristics, Four pole , 415 V,63 Amp breaking capacity 10 kA Make: Legrand/ Havells/ Scheinder | 1 | Each | |
| 87 | 83 | S & F MCB 'C' characterstic single pole 5 to 30 Amp, 240 volt breaking capacity 10 kA Make: Legrand/ Havells/ Scheinder | 14 | Each | |
| 88 | 84 | M&L for submain wiring with 2 single core PVC insulated FRLS cable 6 Sqmm copper conductor PVC sheathed in and including rigid PVC conduit heavy duty of suitable size incl cutting chiseling of wall and making good to disturbed surface of walls / floor etc with plastering painting etc so as to match with the existing finishes, drawn with 6 Sqmm PVC insulated copper conductor cable for earth wire fixed with shaddle and connecting to common earth teriminals complete all as specified. | 50 | RM | |
| 89 | 85 | S & F Blanking plate.(Make: Legarand/Havells/Siemens) | 6 | Each | |
| 90 | 86 | Earthing complete with and including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers , buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to galvanized iron or steel earth lead wire 4.0 mm dia,( NO 8 SWG) by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and connected to main switch or main control board all as shown in electrical plate No. 3 of SSR - 2009(Pt I) & including necessary excavation and earth work. \nThe rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (Light grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Normal mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified. NOTE : The unit rate include earthing lead and protection pipe upto 6.5 metre from top of earth plate. | 1 | Each | |
| 91 | 87 | Supply, laying, testing and commissioning of cable LT XLPE insulated, PVC sheathed armoured, 1.1KV grade using stranded conductor aluminium of size 16 Sqmm 4 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed.\n | 50 | RM | |
| 92 | 88 | Excavation in trenches in hard/tense soil not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out including dressing / trimming sides and leveling/grading and ramming of bottom of excavation complete all as specified. | 3 | Cum | |
| 93 | 89 | Returning, filling in including spreading, leveling, watering and well raming excavated soid in layers not exceeding 25 cm thick, filling back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete all as specified. | 2.7 | Cum | |
| 94 | 90 | Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.nexc 1.5 mtr above starting point where directed complete all as specified. | 0.3 | Cum | |
| 95 | 91 | Double walled corrugated HDPE duct pipe of 40 mm inner dia confirming to IS:14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. Make :Finolex / Duraline / Telerex /Gemini | 25 | RM | |
| 96 | 92 | Supply and fixing GI pipe, light grade 40 mm bore, ISI Marked for protection to cable along the pole/across road crossing/passing through culvert complete all as specified. | 15 | RM | |
| 97 | 93 | Amount of credit of Rs. 8139.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender