}

Annual Maintenance Contract Of Grid Stations And Tr Lines . Amc Of Grid Stations And Tr Lines Mattan-Kulgam Of Tlmd-Vi, Mattan and Kulgam-Jammu And Kashmir

Jammu And Kashmir Power Development Department has published Annual Maintenance Contract Of Grid Stations And Tr Lines . Amc Of Grid Stations And Tr Lines Mattan-Kulgam Of Tlmd-Vi. Submission Date for this Tender is 24-06-2020. Tanks and Cylinders Tenders in Mattan and Kulgam Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

24553128
Annual Maintenance Contract Of Grid Stations And Tr Lines . Amc Of Grid Stations And Tr Lines Mattan-Kulgam Of Tlmd-Vi
Tender
Indian
Jammu And Kashmir
Mattan And Kulgam
24-06-2020

Tender Details

annual maintenance contract Of Grid Stations And Tr Lines . Amc Of Grid Stations And Tr Lines Mattan-Kulgam Of Tlmd-Vi , grid stations , power transformers: general checking /visual inspection of transformers ( i ) checking/arresting of oil leakages ( ii ) checking of auto starting of fans , external cleaning of radiators , cleaning of marshalling boxes of transformer and oltc , ( iii ) tightening of terminations , checking of oltc driving mechanism , electrical checking/ testing of prv , buchholz relay , oltc surge relay/ checking of alarm & trip and checking / tightening of earthing connections , checking of earth resistance of neutral and ( iv ) replacement of silca gel of breathers for 50mva power transformers , conducting of scheduled preventive tests of power transformer viz . ir , bdv , ppm , tan-delta /capacitane of bushing/ winding and dga , checking oil level of conservator tank & topping of oil if required by way of dehydration/filteration including cost transformer oil for 50mva /20mva , onload oil filteration for 50mva /20mva transformers , repairing of cooling fans of transformers including replacement of damaged winding , bearing if required , overhualing of circuit breaker :- checking of gas pressure , pressure switch setting etc , checking of healthiness of accumulator by checking the pre-charging pressure when building up pressure from zero , checking of operation of safety valve , cleaning of breaker units , checking of protection equipmentsand replacement of defective ones , i . e . , complete inspection and testing of sf6 type circuit breakers inclusive of operating mechanism . maintaining gas levels , venting of circuit breakers , replacement of o-rings , gas kits including circuit breaker analysis by cba etc . , fixing tripping & closing coils for 132kv sf6 cb ( rate shall be quoted per cb ) , fixing tripping & closing coils for 33kv vcb ( rate shall be quoted per cb including material cost ) , filling of sf6 gas to maintain requisite pressure of sf6 cbs with cost per kg , fixing latches /remote switches , spring , toggle switch for sf6 cb and vcb , spring charging motor ( rates shall be per 132kv cb ) , fixing latches /remote switches , , spring charging motor ( rates shall be per 33kv cb ) , fixing & providing vacuum interrupter of repute make for 33kv vcb ( siemens/cgl/abb/bhel ) , current transformers :- checking of bellow expansion , checking of oil leakage in terminal box , checking of primary connection strips , checking of healthiness of gaskets , checking the tightness of all connections including earthing of pf terminal , cleaning of porcelain , marshalling box and junction box , checking cleanliness / tightness of all electrical connections including earthing of all marshalling boxes , ct secondary terminal , space heater and illumination , healthiness of secondary terminal bushing , checking of oil level , measurement of ir value tightening of jumpers , ct analysis with the help of cta etc . , 132kv ct , 33kv ct , cvts / pts :- visual checking of earthing hf point ( in case it is not being used for plcc , checking of any breakage or cracks in cementing joint , cleaning of cvt capacitor stacks and tightness of terminal connections , checking of space heater and illumination in pt mks , checking and tightness of all connections including earth connections cleaning of porcelain , marshalling box and junction box , checking of healthiness of gaskets , checking of neutral earthing in cvt , healthiness of all gaskets and oil level . measurement of ir value and tightening of all connections and droppers . , 132kv cvt , 33kv pt , surge arrestors :- checking of leakage current ( third harmonic resistive current ) , testing of counters and leakage current meters , checking of earth connections between surge arrester , surge monitor and earth , checking of leakage current after cleaning of porcelain surface , measurement of ir value and tightening of droppers and testing of counter and leakage of current meters , cleaning of insulators , checking of earth cennections between surge arrester , surge monitor and earth . , 132kv la , 33kv la , isolators :- maintenance of linkages including transmission gears , stopper bolts . cleaning of auxiliary switch contacts and greasing with silica grease , cleaning of support insulators , termination contacts , checking of elecctrical / mechanical interlocks with e/s and cb , mounting bolts , alignment , nuts , pins , space heater , illumination , healthiness of gaskets , auxiliary contacts , alignment of earthing blades , operation of earth switch , almunium / copper flexible conductor , earth connections of structures and mb . lubrication of operating mechanism , hinges lock joints , levers , bearings , main contacts , cleaning of post insulators , tightening of clamps , bolts /nuts . , 132kv isolator , 33kv isolator , reparing of three phase motors of isolators including replacement of damaged winding and bearing . , providing / replacement of damaged / burnt droppers , jumpers for isolators/ breakers/transformers / ct / pt / pi/la etc . 132kv & 33kv switch yards , replacement of damaged clamps & connectors for isolators/ breakers/transformers / ct / pt / pi/la etc . for 132kv & 33kv switch yards as per tech specs . & drgs to be provided by the department , post insulators :- checking of insulators for cracks and cleaning of insulators and tightening of droppers for 132kv & 33kv level ( rate shall be per pi ) , fixing of post insulators ( if damaged ) as per tech specs . & drgs to be provided by the department , 132kv pi , 33kv pi , checking & tightening of bus bar & its clamps/ jumpers/ droppers including adjustment of sags . ( rate shall be per meter conductor ) , fixing of bus bar conductors , its droppers / jumpers including requisite clamps ( if damaged ) ( rate shall be per meter conductor ) , provididng and fixing of disc insulators ( 70kn /90kn / 120kn ) ) , visual inspection & checking & tightening of all bolts , nuts with washers of gi latice towers , beams and equipment pipe structures , 132kv bay , 33kv bay , providing and fixing of missing / damaged gi bolts , nuts with washers and gi lattice members of towers , beams and equipment pipe structures , illumination system :- inspection/checking healthiness of fittings & luminaries of control room , office , residential quarters , sentary post . main entry gate and repairing and replacement if required . , out door illumination system :- inspection/checking of healthiness of fittings & luminaries & mcb , lighting panels of outdoor switch yard , including high mast . , providing & replacement of damaged/burnt items . viz . mcb , fuses , fixtures , pvc frls cable , led lamps/tubes/led flood lights , in outdoor yards if required . , battery bank: inspection/checking and cleaning of battery cell terminals , application of petrolium jelly , if required , conduction of battery impendence and discharge test & checking voltage temperature , current , terminals voltage and battery discharge testing etc . , battery charger :- inspection/checking of control cards , measurement of test point voltage values , testing of dc earthfault and u/v relays , ir measurement of charger transformer , cables , checking of earthing etc . checking of charger panel and dcdb for electrical connections , cleanliness etc . , protection system :- inspection / checking of protection relays and application of ccl4 for cleaning , checking of control wiring rate shall be per panel including /installation , commisioning and testing of protective relays ( relay will be provided by department ) , cleaning of cable trenches and cables including of dressing of cables , setting right the cable trays & racks etc , auxilary transformer :- inspection /checking of bush rods

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail