Supply And Installation Of 63 Kva Diesel Generator
Tender Overview
Project Description
Supply And Installation Of 63 Kva Diesel Generator , Supply Of 63 Kva Diesel Generator , Supply Of 63 Kva Diesel Generator , Installaion Charge , Installation Charges Of 63 Kva Dg Set On The Existing Cement Concrete Foundation , Stc Of Trickle Charger Unit Suitable For 63Kva Dg Set And Giving Connections , Supply And Providing 100 Mm /Nearest Size Ms Pipe 5Mm Thickness ( Tata/Jindal Make ) Complete With Suitable Size 12 Mm Thick Flanges Coupling With Minimum 4/5 Mtr Length Using Suitable Packing , Ms Bolt , Nut And Washersa And Raisingthe Same Using Chain Pullies , Necessary Scafoldings , Supporting With Main Building Using Necessary Channel /Angle In Suitable Size , Etc . Incluing Painting With Two Coats Of High Temperature Resistant Aluminium Paint Etc . For Extending The Exhaust Pipe Of 63 Kva Diesel Generator , Do - 150Mm/Nearest Size Ms Pipe , Earth Work Excavation In Ordinary Soil And Despositing With A Lead Up To A 50 M And Lift Up To 1 . 50M Including Neat Banking , Cement Concretye 1:2:4 Using 20Mm Broken Stone For Reinforced Concrete Work , Plain Cement Concrete 1:4:8 Using 40Mm ( Normal Size ) Broken Stone ( M3 ) , Plastering With Cement Motor 1:4 , 12Mm Thick One Coat , Reinforcement For R . C . C Works , Bend Tied And Placedin Position ( Plain Grill Requiring Blend Cold ) Using Torsteel , Supply Of Hsd For Trail Run , Load Testing 63 Kva Dg Swet Including All Equipments And Hire Charges Of T And P Excluding Fuel , Fabrication Of Fully Partioned , Dust And Vermin Proof Enclosure For Panel Assembly As Per Form 4 Of Is 8623 ( With Latest Amendments ) Using 1 . 60Mm Crca Sheet As Per Approved Desighn And Requirements , With Front And Access Facility , Bus/Chambers , Hinged Doors For All Switch Gear Compartment , Earthing Doors Using 4 Sqmm Brided Copper Conducter , Provideing Necessary Cutouts For Mounting Meters , Relays , Indication Lamps , Bus/Interconnection Etc , Detachable Covers For Bus/Chamber And Cable Aley , Powder Coating The Assembly After Subjecting To 7 Tank Process Etc . As Required . Crca Sheet Alone Be Used For The Fabrication . Angles /Flatch/Sloated Angles Etc Shall Not Be Used For The Fabrication Of Panel Assembly . The Messurement Should Be Taken The Area Of The Complete Sheet Used For Panel Board Including Partions , Folding , Shrouding Etc . Including Control Wiring . , Supply And Fixing The Following Types Of Beeding Along The Periphery Of Doors /Ather Detachable Compartment To Make The Panel Assembly Dust And Vermin Proof Including Sticking With Glue A Section Neoprene Beeding Suitable For 1 . 60/2 . 00 Mm Sheet , Supply And Providing The Following Size Of Smc Sheets In The Panel As Barriers And Shrouding Using Required Bolts And Nuts Including Cutting To Shape Etc . , As Required 3Mm Thick , Fabrication , Supply , Coveyance And Installation Of Base Frame For Floor Mounting Type Panel Board Using Channel Of Class Designation Ismc 75 Including Cutting , Welding , Drilling Holes , Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer , Bolting The Frame To The Panel And To The Finished Floor Using Required Bolt And Nuts , Making Good Damages Etc . As Required . , Fabrication , Supply , Coveyance And Installation Of Angel Iron Frame Work For Wall Mountoing Panel Board Using Suitable Size Angle Iron Cut And Welded To Shape Including Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer , Bolting Frame To The Using Required Bot And Nuts , Fixing The Whole To The Wall , Making Good The Damages Etc . As Required . , Fabrication , Supply And Fixing Main Bus Bar System And Inter Connections With Electrolyte Grade Copper Strips/Rigid Conducters Conforming To Is 1867 ( With Latest Amendments ) For Bus Bar Arrangement With Single Srip Per Phase Supported On Finger Type Bus Bar Supports Of Adequate Size , Spacing Between Supports Not Exeeding 50 Cm And Overhang Not Exeeding 5 Cm Including Bending To Shape , Drilling Holls , Tinning The Points Of Contacts , Fixing Heet Shrinkable Pvc Sleeves , Plated Bolts And Nuts With Plate Washers And Spring Washers , Copper Sockets For Round Conducters . Etc . As Required , Fabrication , Supply And Fixing Earth Bus System With Copper Strip/Conducter And Connecting All Accessories As Per Rule Including G Tinning The Points Of Contacts Etc As Required . , 100A , 35/36 Ka ( Ics=100% Icu ) , 3 Pole , Current Limiting Type Mccb With Micro Processor Based Release With Overload Setting Of 50 - 100 % Having Adjustable Ol And Sc , S And F Earth Fault Modules For 100A Mccb , S And F Rotary Handle Kit For 100A Mccb , S And F Spreader Terminal For 100 A Mccb , 63 A , Tpn Sdf Ac 23 A Duty , 32 A , Tpn Sdf Ac 23 A Duty , 2-80 A , Din Type Fuse Link , Supply And Fixing Automatic Change Over With Current Limiter Switch ( Accl ) Suitable For 3 Phase 40 A For Eb Side Current Limitting And Source Selection Alomg With Site Selectable Setting Of Dg Side . Prok Dvs Make Paccl - 31140 Or Equivalent Make , Do Suitable For 1 Phse 40 A For Eb Side And 25-40For Dg Side And Optoinal Features For Eb Side Current Limitting And Sourcing Selection Along With Site Selectable Setting Of Dg Side . Proke Dvs Make Paccl - 1140 Or Equivalent Make , Three Phase Multifunction Meters To Read V , A And F , Accuracy Class 1 , 100/5A , 5Va , Resin Caste Metering Ct Of Accuracy Class 0 . 5 , 100/5A , 5Va , 10P5 , Tape Wound Protection Cbct , Led Indicaters For All Voltage Rangers - Blue Colour , Led Indicators For All Voltage Ranges - Red , Green , Black , Yellow Or Orange Colour , Aluminium Anodised Danger Notice Board Of Size 200X150 Mm With Inscriptions ) Both In English And Malayalam ) And Coventional Skull And Bone In Red Colour , Carrying Out Conrol Wiring For Panel With Normal Meters And Indication Lamps Alone With 650/1100 V Grade Pvc Insulated Standered Single Core Copper Conducter Cables Confirming To Is 694 Part 11990 For Inter Connecting The Control Devices /Equipments Including Providing Suitable Size Insulater Sockets Etc As Required 1 . 50 Sq Mm Single Run With Required Sockets , 2 A 10Ka , Sp Mcb ( C Curve ) , Supply And Laying Of 1 No Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1 . 1 Kv Grade Of The Following Sizes In The Existing Dwc Pipe As Reqired . 3 1/2 Core 70 Sqmm , Do-2 Core 4 Sqmm , Do-10 Core 1 . 50 Sqm , Supply , Laying And Clamping Of 1 No Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable , 1 . 11 Kvgrade Of The Following Sizes Usingclamps Noted Along With The Cables , Spacing Of Clamps Not Exeeding 60 Cms , Making Good The Damages , Colour Washing Etc . As Required . 3 1/2 Core 70 Sqmm , Do-2 Core 4 Sqmm , Do-2 Core 10 Sqmm , Do-4 Core 16 Sqmm , Do-4 Core 25 Sqmm , Supplying , Laying And Jointing Of The Following Sizes Of Double Wall Corrugated ( Dwc ) Pipes Made Out Of Hdpe Conforming To Is 14930 Part Second For Mechanical Protection To Underground Power Cables With All Required Accessories In Ground In The Including Excavation 90/75Mm Or Nearest Size , Do-63/50 Mm Or Nearest Size , Do-40/32 Mm Or Nearest Size , Supplying Siemens /Tropouder Type Nickel Plated Single Compression Brass Cable Gland For Pvc Insulated And Pvc Sheated Armoured Aluminium/Copper Conducter Cable 1 . 1 Kv Grade , And Making And Termination Suitable For 2/3/31/2 /4 Core Cable Of The Following Sizes As Required Sqmm , 10 Sqmm , 16 Sqmm , 25 Sqmm , 70 Sqmm , Supplying And Providing Earth Clamps For Siemens/Tropodour Type Cable Glands Of Suitable Length Other Diemensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required For Sqmm To 16 Sqmm With 12Mm Wide X 1 Mm Thick Clip , 25 Sq- 95 Sq Mm With 20 Mm Wide X 1 . 20 Mm Thick Clip , Supply Of Superior Quality Aluminium Tubuler Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc As Required For Sqmm , 10 Sqmm , 16 Sq
BOQ
| Name of Work:Supply and Installation of 63 KVA Diesel Generator | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | SUPPLY OF 63 KVA DIESEL GENERATOR | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.01 | Supply of 63 KVA Diesel Generator | BI01010001010000000000000515BI0100001113 | 1 | Nos |
| 3 | 2 | INSTALLAION CHARGE | BI01010001010000000000000515BI0100001124 | ||
| 4 | 2.01 | Installation charges of 63 KVA DG Set on the existing cement concrete foundation | BI01010001010000000000000515BI0100001125 | 1 | Nos |
| 5 | 2.02 | STC of trickle charger unit suitable for 63KVA Dg Set and giving connections | BI01010001010000000000000515BI0100001126 | 1 | Nos |
| 6 | 2.03 | Supply and providing 100 mm /nearest size MS pipe 5mm thickness(Tata/jindal make)complete with suitable size 12 mm thick flanges coupling with minimum 4/5 mtr length using suitable packing ,MS bolt,nut and washersa and raisingthe same using chain pullies,necessary scafoldings ,supporting with main building using necessary channel /angle in suitable size ,etc. incluing painting with two coats of high temperature resistant aluminium paint etc. for extending the exhaust pipe of 63 KVA Diesel Generator | BI01010001010000000000000515BI0100001127 | 2 | Mtr |
| 7 | 2.04 | Do - 150mm/nearest size MS pipe | BI01010001010000000000000515BI0100001128 | 1 | Mtr |
| 8 | 2.05 | Earth work excavation in ordinary soil and despositing with a lead up to a 50 m and lift up to 1.50m including neat banking | BI01010001010000000000000515BI0100001129 | 3 | M3 |
| 9 | 2.06 | Cement concretye 1:2:4 using 20mm broken stone for reinforced concrete work | BI01010001010000000000000515BI0100001130 | 2 | M3 |
| 10 | 2.07 | Plain cement concrete 1:4:8 using 40mm(normal size )broken stone (m3) | BI01010001010000000000000515BI0100001131 | 1.6 | M3 |
| 11 | 2.08 | Plastering with cement motor 1:4, 12mm thick one coat | BI01010001010000000000000515BI0100001132 | 4 | M3 |
| 12 | 2.09 | Reinforcement for R.C.C works, bend tied and placedin position(plain grill requiring blend cold) using torsteel | BI01010001010000000000000515BI0100001133 | 40 | KG |
| 13 | 2.1 | Supply of HSD for trail run | BI01010001010000000000000515BI0100001134 | 150 | Ltr |
| 14 | 2.11 | Load testing 63 KVA DG swet including all equipments and Hire charges of T and P excluding fuel | BI01010001010000000000000515BI0100001135 | 1 | Hr |
| 15 | 2.12 | Fabrication of fully partioned,dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments )using 1.60mm CRCA sheet as per approved desighn and requirements, with front and access facility, bus/Chambers, hinged doors for all switch gear compartment, earthing doors using 4 sqmm brided copper conducter, provideing necessary cutouts for mounting meters,relays,indication lamps, bus/interconnection etc,detachable covers for bus/chamber and cable aley, powder coating the assembly after subjecting to 7 tank process etc. as required.CRCA sheet alone be used for the fabrication. angles /flatch/sloated angles etc shall not be used for the fabrication of panel assembly.The messurement should be taken the area of the complete sheet used for panel board including partions, folding,shrouding etc. including control wiring . | BI01010001010000000000000515BI0100001136 | 8 | M2 |
| 16 | 2.13 | Supply and fixing the following types of beeding along the periphery of doors /ather detachable compartment to make the panel assembly dust and vermin proof including sticking with glue \"A \" section neoprene beeding suitable for 1.60/2.00 mm sheet | BI01010001010000000000000515BI0100001137 | 30 | Mtr |
| 17 | 2.14 | Supply and providing the following size of SMC sheets in the panel as barriers and shrouding using required bolts and nuts including cutting to shape etc., as required 3mm thick | BI01010001010000000000000515BI0100001138 | 0.4 | M2 |
| 18 | 2.15 | Fabrication ,supply,coveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting ,welding,drilling holes ,painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good damages etc. as required . | BI01010001010000000000000515BI0100001139 | 4 | Mtr |
| 19 | 2.16 | Fabrication ,supply,coveyance and installation of angel iron frame work for wall mountoing panel board using suitable size angle iron cut and welded to shape including painting with two coats of synthetic Enamel paint over a coat of Zinc chromate primer, bolting frame to the using required bot and nuts, fixing the whole to the wall, making good the damages etc. as required . | BI01010001010000000000000515BI0100001140 | 10 | KG |
| 20 | 2.17 | Fabrication ,supply and fixing main bus bar system and inter connections with electrolyte grade copper strips/rigid conducters conforming to IS 1867 (with latest amendments ) for bus bar arrangement with single srip per phase supported on finger type bus bar supports of adequate size,spacing between supports not exeeding 50 cm and overhang not exeeding 5 cm including bending to shape ,drilling holls, tinning the points of contacts ,fixing heet shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers,copper sockets for round conducters . etc.as required | BI01010001010000000000000515BI0100001141 | 1100 | CM3 |
| 21 | 2.18 | Fabrication,supply and fixing earth bus system with copper strip/conducter and connecting all accessories as per rule including g tinning the points of contacts etc as required. | BI01010001010000000000000515BI0100001142 | 300 | CM3 |
| 22 | 2.19 | 100A, 35/36 kA (Ics=100% Icu), 3 pole ,current limiting type MCCB with micro processor based release with overload setting of 50 - 100 % having adjustable OL and SC | BI01010001010000000000000515BI0100001143 | 1 | Nos |
| 23 | 2.2 | S and F earth fault modules for 100A MCCB | BI01010001010000000000000515BI0100001144 | 1 | Nos |
| 24 | 2.21 | S and F Rotary Handle Kit for 100A MCCB | BI01010001010000000000000515BI0100001145 | 1 | Nos |
| 25 | 2.22 | S and F spreader terminal for 100 A MCCB | BI01010001010000000000000515BI0100001146 | 3 | Nos |
| 26 | 2.23 | 63 A,TPN SDF AC 23 A duty | BI01010001010000000000000515BI0100001147 | 3 | Nos |
| 27 | 2.24 | 32 A, TPN SDF AC 23 A duty | BI01010001010000000000000515BI0100001148 | 4 | Nos |
| 28 | 2.25 | 2-80 A,DIN type fuse link | BI01010001010000000000000515BI0100001149 | 15 | Nos |
| 29 | 2.26 | Supply and fixing Automatic change over with current limiter switch (ACCL) suitable for 3 phase 40 A for EB side current limitting and source selection Alomg with site selectable setting of DG side. Prok dv's make PACCL - 31140 or equivalent make | BI01010001010000000000000515BI0100001150 | 2 | Nos |
| 30 | 2.27 | Do suitable for 1 phse 40 A for EB side and 25-40for DG side and optoinal features for EB side current limitting and sourcing selection along with site selectable setting of DG side . Proke dv's make PACCL - 1140 or equivalent make | BI01010001010000000000000515BI0100001151 | 2 | Nos |
| 31 | 2.28 | Three phase multifunction meters to read V,A and F,accuracy class 1 | BI01010001010000000000000515BI0100001152 | 1 | Nos |
| 32 | 2.29 | 100/5A,5VA,resin caste metering CT of accuracy class 0.5 | BI01010001010000000000000515BI0100001153 | 3 | Nos |
| 33 | 2.3 | 100/5A ,5VA,10P5,tape wound protection CBCT | BI01010001010000000000000515BI0100001154 | 1 | Nos |
| 34 | 2.31 | Led indicaters for all voltage rangers - blue colour | BI01010001010000000000000515BI0100001155 | 1 | Nos |
| 35 | 2.32 | LED indicators for all voltage ranges - red ,green,black,yellow or orange colour | BI01010001010000000000000515BI0100001156 | 2 | Nos |
| 36 | 2.33 | Aluminium anodised Danger Notice Board of size 200x150 mm with inscriptions)both in english and malayalam) and coventional Skull and Bone in red colour | BI01010001010000000000000515BI0100001157 | 2 | Nos |
| 37 | 2.34 | Carrying out conrol wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated standered single core copper conducter cables confirming to IS 694 part 11990 for inter connecting the control devices /equipments including providing suitable size insulater sockets etc as required 1.50 sq mm single run with required sockets | BI01010001010000000000000515BI0100001158 | 20 | Mtr |
| 38 | 2.35 | 2 A 10kA ,SP MCB(C curve) | BI01010001010000000000000515BI0100001159 | 7 | Nos |
| 39 | 2.36 | Supply and laying of 1 No PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing DWC pipe as reqired . 3 1/2 core 70 sqmm | BI01010001010000000000000515BI0100001160 | 17 | Mtr |
| 40 | 2.37 | Do-2 core 4 sqmm | BI01010001010000000000000515BI0100001161 | 17 | Mtr |
| 41 | 2.38 | Do-10 core 1.50 sqm | BI01010001010000000000000515BI0100001162 | 25 | Mtr |
| 42 | 2.39 | Supply ,laying and clamping of 1 No PVC insulated and PVC sheathed armoured aluminium power cable,1.11 Kvgrade of the following sizes usingclamps noted along with the cables, spacing of clamps not exeeding 60 cms ,making good the damages,colour washing etc. as required .3 1/2 core 70 sqmm | BI01010001010000000000000515BI0100001163 | 35 | Mtr |
| 43 | 2.4 | Do-2 core 4 sqmm | BI01010001010000000000000515BI0100001164 | 23 | Mtr |
| 44 | 2.41 | Do-2 core 10 sqmm | BI01010001010000000000000515BI0100001165 | 42 | Mtr |
| 45 | 2.42 | Do-4 core 16 sqmm | BI01010001010000000000000515BI0100001166 | 14 | Mtr |
| 46 | 2.43 | Do-4 core 25 sqmm | BI01010001010000000000000515BI0100001167 | 15 | Mtr |
| 47 | 2.44 | Supplying,laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 part second for mechanical protection to underground power cables with all required accessories in ground in the including excavation 90/75mm or nearest size | BI01010001010000000000000515BI0100001168 | 17 | Mtr |
| 48 | 2.45 | Do-63/50 mm or nearest size | BI01010001010000000000000515BI0100001169 | 17 | Mtr |
| 49 | 2.46 | Do-40/32 mm or nearest size | BI01010001010000000000000515BI0100001170 | 17 | Mtr |
| 50 | 2.47 | Supplying siemens /tropouder type nickel plated single compression brass cable gland for PVC insulated and PVC sheated armoured aluminium/copper conducter cable 1.1 KV grade,and making and termination suitable for 2/3/31/2 /4 core cable of the following sizes as required sqmm | BI01010001010000000000000515BI0100001171 | 2 | Nos |
| 51 | 2.48 | 10 sqmm | BI01010001010000000000000515BI0100001172 | 12 | Nos |
| 52 | 2.49 | 16 sqmm | BI01010001010000000000000515BI0100001173 | 6 | Nos |
| 53 | 2.5 | 25 sqmm | BI01010001010000000000000515BI0100001174 | 4 | Nos |
| 54 | 2.51 | 70 sqmm | BI01010001010000000000000515BI0100001175 | 8 | Nos |
| 55 | 2.52 | Supplying and providing earth clamps for siemens/tropodour type cable glands of suitable length other diemensions noted along with each size of glands for the following sizes of cables as required for sqmm to 16 sqmm with 12mm wide x 1 mm thick clip | BI01010001010000000000000515BI0100001176 | 20 | Nos |
| 56 | 2.53 | 25 sq- 95 sq mm with 20 mm wide x 1.20 mm thick clip | BI01010001010000000000000515BI0100001177 | 12 | Nos |
| 57 | 2.54 | Supply of superior quality aluminium tubuler cable socket and making core termination of cables of the following sizes including crimping etc as required for sqmm | BI01010001010000000000000515BI0100001178 | 4 | Nos |
| 58 | 2.55 | 10 sqmm | BI01010001010000000000000515BI0100001179 | 24 | Nos |
| 59 | 2.56 | 16 sqmm | BI01010001010000000000000515BI0100001180 | 24 | Nos |
| 60 | 2.57 | 25 sqmm | BI01010001010000000000000515BI0100001181 | 16 | Nos |
| 61 | 2.58 | 35 sqmm | BI01010001010000000000000515BI0100001182 | 8 | Nos |
| 62 | 2.59 | 70 sqmm | BI01010001010000000000000515BI0100001183 | 24 | Nos |
| 63 | 2.6 | 1.50 sqmm copper | BI01010001010000000000000515BI0100001184 | 20 | Nos |
| 64 | 2.61 | Supply and providing plate earthimng as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20mm GI watering pipe fixed to the earth plate with 20x3 mm Gi clamps, GI funnel with weld mesh ,filling required quantity of carcoal including construction of inspection chamber with wed concrete of 1:4:8 PCC using 40mm broken stone (10cm thick) , bick work in cement motor 1:6 ,plastering the surface of brick masonry and the exposed surface of PCC bed with cement motar 1:4, 12 mm thick ,(the finished inside diemension shall be 300x300x300mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.(in ordinary soil) | BI01010001010000000000000515BI0100001185 | 3 | Nos |
| 65 | 2.62 | Supply and providing the following sizes of caste iron gully trap with covering at the top of theinspection champer of earth pit as required 300x300x6mm caste iron gully trap with covering | BI01010001010000000000000515BI0100001186 | 3 | Nos |
| 66 | 2.63 | 2 x 25 x 3 mm tinned copper strip | BI01010001010000000000000515BI0100001187 | 0.75 | M |
| 67 | 2.64 | Supply and providing earth from the test joined to the earth electrodeusing the following sizes of conducters/stripes including cutting,drilling necessary holes(in case of strip) and fixing firmly with plate test joined etc. as required. 32 X 6 mm GI strip tinned at the points of contact | BI01010001010000000000000515BI0100001188 | 12 | Mtr |
| 68 | 2.65 | Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc as required( in ordinary soil) 6.00 mm copper conductor (4 SWG) | BI01010001010000000000000515BI0100001189 | 65 | Mtr |
| 69 | 2.66 | Supply and clamping the following sizes of stripes on surface of wall/parapet/existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles , spacing of clamps not exeeding 1m,making good the damages ,colour washing etc as required 25 x 3mm copper strip tinned at the points of contacts. | BI01010001010000000000000515BI0100001190 | 1 | Mtr |
| 70 | 2.67 | Supply and drawing bare earthing conducters of the following sizes along with wiring /cables/and giving connection as required 6.00mm copper conductor (4 SWG) | BI01010001010000000000000515BI0100001191 | 25 | Mtr |
| 71 | 2.68 | Do 3.15 mm copper conductor (10 SWG) | BI01010001010000000000000515BI0100001192 | 25 | Mtr |
| 72 | 2.69 | Supply of superior quality (dowell's) copper socket suitable for 6mm (4SWG) size copper including crimping etc as required. | BI01010001010000000000000515BI0100001193 | 24 | Nos |
| 73 | 2.7 | Do 3.15.00 mm copper conductor (10SWG) | BI01010001010000000000000515BI0100001194 | 24 | Nos |
| 74 | 2.71 | Supply and providing 25 x 6 m brass bolt, nut with washer on the earth bus/ switch box as required | BI01010001010000000000000515BI0100001195 | 24 | Nos |
| 75 | 2.72 | Supply and clamping the following sizes of \"B\" class GI pipe on wall with all required accessories and clamps etc including cutting and making good the walls ,painting the exposed portions etc as protect covering to earth leads/cables 25mm dia | BI01010001010000000000000515BI0100001196 | 20 | Mtr |
| 76 | 2.73 | Supply and providing 5 kg Dry Chemical Power type Fire Exingusher with horse and clamps including fixing it to wall as requied. | BI01010001010000000000000515BI0100001197 | 4 | Nos |
| 77 | 2.74 | Supply and providing 2mm thick elastomeric fire reatrdent insulating mat as per Is 15652 /2006 to withstand 2.3 KV dielectric strength | BI01010001010000000000000515BI0100001198 | 4 | M2 |
| 78 | 2.75 | Supply and providing 9 L capacity Gi fire bucket paintedin post office red with primer coat of red oxide and written with white paint \"FIRE\" mounted on Msangle frame work/wall bracket filled with fine sand,painting the bracket/floor stand including making good the damages,colour washing etc as required | BI01010001010000000000000515BI0100001199 | 4 | Nos |
| 79 | 2.76 | Supply andproviding first aid chart duly framed and placed in a conspicuous location for cler vision | BI01010001010000000000000515BI0100001200 | 2 | Nos |
| 80 | 2.77 | Preparation of drawings including Schematic circuit daigram necessary approval from the electrical Inspectorate including all fee etc (Actual amount paid on origianl chellan/bill/invoice) | BI01010001010000000000000515BI0100001201 | 1 | Nos |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed