Repair Maintenance Replacement Of Unsv Dg Set Spares Amf Panel Solar Water Heater And Pipe Line And Connected Works At Af Station Bihta, GE AF Bihta-Bihar

Military Engineer Services-MES has published Repair Maintenance Replacement Of Unsv Dg Set Spares Amf Panel Solar Water Heater And Pipe Line And Connected Works At Af Station Bihta. Submission Date for this Tender is 24-06-2020. Diesel Generators Tenders in GE AF Bihta Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

24536141
Corrigendum : Repair Maintenance Replacement Of Unsv Dg Set Spares Amf Panel Solar Water Heater And Pipe Line And Connected Works At Af Station Bihta
Open Tender
Indian
Bihar
GE AF Bihta
24-06-2020

Tender Details

Repair Maintenance Replacement Of Unsv Dg Set Spares Amf Panel Solar Water Heater And Pipe Line And Connected Works At Af Station Bihta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 38000.0 /-
Tender Value
INR 18.82 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT/REPLACEMENT OF UNSV DG SET SPARES, AMF PANEL, SOLAR WATER HEATER AND PIPE LINE AND CONNECTED WORKS AT AF STATION BIHTA.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for inspection, maintenance and servicing of complete DG Set of capacity between 15-75 KVA (Inspection & Maintenance comparising of Engine/ Alternator/ Control panel) including replacement of unserviceable spare parts where required, for smooth functioning of DG Set through the representatives of authorised dealer/OEM of Kirloskar and cummins complete all as per manufacturers instructions and as directed by Engineer-in-Charge as under :- \nMake of DG Set : Kirloskar and Cummins\n(A). 'A' Check (a) Lubricating oil condition (b) Engine oil and water leakage (c) Mounting structure of DG Set and other nut bolts of engine and alternator (d) Fan Belts and their adjustment required for smoothe operation of driver (e) cleaning of air filters (f) Adjusment of valve clearance (g) change of oil/Fuel filters and engine oil if necessary (h) solonoid switch, battery and battery charger (j) cooling system and fuel system \n(k) checking of all power cables and AVR connections etc (l) control panel meters and functioning of gadgets (m) functioning of control and safety system. \n(B) 'B' Check (a) Flexible coupling of engine and alternator (b) cleaning of crank case ventilation pipe (c) checking of injectors and fuel pump (d) checking of alternator and carbon brushes etc. \nNote. (a) The cost of spares required for maintenance shall be measured and paid separtely under relevant items \n(b) Spare parts shall only be purchased from the authorised dealers. 10 EACH JOB
2 2 M&L for inspection, maintanance and servicing of AMF panel of any capacity of DG Set in between 40-75 KVA for trouble free functioning as required at site including replacement of unserviceable spare parts complete comprising of (a) Checking all electrical connections(b) Checking all contact point/ Bus bars(c) Checking / replace timers (AC or DC)(d) Checking / replace buttons(e) Checking / replace selector switch (f) Checking / replace indicator lamps(g) Checking / replace main / auxiliary contacts / relays(h) Checking / replace contact coil(j) Checking / replace of volt/amps meters (k) Checking auto/manual function(l) Check battery charger out put voltage(m) Cleaning the panel HRC fuses and connections complete \nNote. (a) The cost of spares required for maintenance shall be measured and paid separtely under relevant items \n(b) Spare parts shall only be purchased from the authorised dealers. 9 EACH JOB
3 3 S & F Oil Filter suitable Cummins DG Set 40 KVA . Cat part No - 0122 0922 Make- Kirloskar/ Mico /Falcon/AGS etc 5 EACH
4 4 S & F Oil Filter suitable for DG Set 15 to 70 KVA. Make : Kirloskar\nMake- Kirloskar/ Mico /Falcon/AGS etc 5 EACH
5 5 S & F Element Air filter (Inner)suitable for 40 KVA DG Set Cummins. \nCat part No -A034P656 Make- Kirloskar/ Mico /Falcon/AGS etc 5 EACH
6 6 S & F Element Air filter (Inner) suitable for 62.5to 70 KVA DG Set Make:Kirloskar. Make- Kirloskar/ Mico /Falcon/AGS etc 5 EACH
7 7 S & F Element Air filter (Outer) suitable for 40 KVA DG Set Cummins. \nCat part No -A034P660 Make- Kirloskar/ Mico /Falcon/AGS etc 5 EACH
8 8 S & F Element Air filter (Outer) suitable for 62.5to 70 KVA DG Set Make:Kirloskar. Make- Kirloskar/ Mico /Falcon/AGS etc 5 EACH
9 9 Supply only inhibitor Corrosion suitable for 40 KVA DG Set Cummins. \nCat part No -3816986 (in 5 Ltr container)\n 5 EACH
10 10 Supply only inhibitor Corrosion suitable for 62.5 to 70 KVA DG Set Make:Kirloskar (in 5 Ltr container) \n 5 EACH
11 11 Supply only Engine Oil 15W 40 (Valvoline premium Blue 7600) \n(in 55 Ltr container ) Cat part No : 505060 Make : Volvolin. 220 LITRE
12 12 Supply only separator fuel water suitable for 40 KVA DG Set \nMake : Cummins. Cat part No -4093731 (in 5 Ltr container)\n 9 EACH
13 13 S & F dynamo fan belt set suitable for for DG Set 62.5 to 75 KVA Make : Kirloskar (2.00 to 2.50 for belts) \nMake: - Kirloskar, /Power king/power grip GTX/dunlop 6 EACH
14 14 S & F dynamo fan belt set suitable for for DG Se 40 KVA Make : Cummens 4 EACH
15 15 S & F water pump suitable for 62.5 to 75 KVA DG Set Make :Kirloskar,\nMake : Kirloskar /Power king/power grip GTX/dunlop 3 EACH
16 16 S & F water pump suitable for for DG Se 40 KVA Make : Cummens 3 EACH
17 17 S & F water hose pipe set with clamps suitable for 62.5 - 70 KVA DG Set Make : Kirloskar 2 SET OF 2
18 18 S & F water hose pipe set with clamps suitable for40 KVA DG Set Make : Cummins 2 SET OF 2
19 19 S & F Relay suitable for Kirloskar Make DG Set 62.5-70 KVA (existing type & voltage -24/12 Volts) in AMF panel and making connections including testing complete all as directed.\nMake: L&T , Siemens or equivalent\n 8 EACH
20 20 S & F Relay suitable for Kirloskar Make DG Set 62.5-70 KVA (existing type & voltage -240 Volts AC) in AMF panel and making connections including testing complete all as directed.\nMake: L&T , Siemens or equivalent\n 6 EACH
21 21 S & F Auxiliary contact suitable for Kirloskar Make DG Set 62.5-70 KVA (Existing type) with logic units. \nMake: L&T/Legrand/ Havells/ Siemens\n 6 EACH
22 22 S & F Main contactors four pole, 220 Volt suitable for 75 KVA DG set of existing model complete all as directed. Make- L&T Havells, legrand etc 6 SET OF 2
23 23 S & F SMPS unit suitable for DG Set 62.5 - 70 KVA DG Set for battery charging including making connections and testing etc complete as specified and as directed. \n(Note : The SMPS shall only be purchased from the authrised dealer) 2 EACH
24 24 M&L for preparation of old surfaces of aquastic enclousers, cleaning dust, dirts, etc. filling Cavities with filler compound and applying two coat of DUCCO paint with existing colour by using spray machine gun including writting SM/MES No. with white paint complete all as specified and as directed. 2 EACH JOB
25 25 M & L for replacement of damaged AMF panel wiring with 1.5/2.5 Sqmm copper conductor FRHS as per existing including replacement of cable treys of existing size and copper thimbles etc complete all as specified and as directed. 2 EACH JOB
26 26 M & L for complete dismantling and servicing of existing unsv solar water heater and collector panel of capacity 100 LPD of any Make with electric back up system after disconnecting the existing water supply/water connection from any height of the building/ ground, including stripping out the hot water vessel by taking out, outer cover, insulating materials etc and continuous brazing /welding of the inner container where required for arresting leakages including replacemnt of defective / worn out spare parts etc and re-assembling the system connecting the water/ electrial connections complete and testing upto the satisfaction of Engr-in-Charge.\nNOTE:-(i) Cost of minor defective /worn out spares is deemed to be included in the quoted rate for this item.\n(ii) Cost for servicing of flat plate collector is also deemed to be included in the quoted rate. Major spares shall be measured and paid separately.\n(iii) Servicing of solar water heater shall be got through the authorised dealer of M/S RASHMI Idustries, Bangalore or original Equipment Manufacturer to avoid any defect.\n 5 EACH JOB
27 27 -ditto- all as per Ser item No 26 above but for solar water heater capacity 200/300 lts/day. 4 EACH JOB
28 28 M & L for replacement of damaged framed work as in ladder of angle or other section with gusser plate, rails, braces etc complete drilled for fixing of steel including hanging, welding and also fastening complete all as specified and as directed. 100 KILOGRAM
29 29 Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed. 142 CUBIC METRE
30 30 Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. 35.5 CUBIC METRE
31 31 Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as specified. 106.5 CUBIC METRE
32 32 Providing precast slab of cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate set in cement mortar 4 CUBIC METRE
33 33 M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate mechanically crushed stone for mass filling/patching work in pole copping including making smooth surface matching with existing coping complete all as specified. 3 CUBIC METRE
34 34 M & L brick work with sub class 'B' brick straight or curved on plan exceeding 6m mean radious built in CM 1:4 complete all as specified and as directed. 4 CUBIC METRE
35 35 S & F in replacement of unsv/damaged GI tubing 15mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. 60 RUNNING MMETRE
36 36 S & F in replacement of unsv/damaged GI tubing 20mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. 60 RUNNING MMETRE
37 37 S & F in replacement of unsv/damaged GI tubing 25mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. 60 RUNNING MMETRE
38 38 S & F in replacement of unsv/damaged hot water pipe line 15mm bore insulated with glass wool and aluminium cladding complete all as specified and directed. 120 RUNNING MMETRE
39 39 S & F in replacement of unsv/damaged gun metal globe or gate valve of 15mm sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected. 9 EACH
40 40 S & F in replacement of unsv/damaged gun metal globe or gate valve of 20mm sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected. 9 EACH
41 41 S & F in replacement of unsv/damaged gun metal globe or gate valve of 25mm sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected. 9 EACH
42 42 S & F in replacement of unsv/damaged 15mm bib tap cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. 5 EACH
43 43 M & L for replacement of defective XLPE insulated screened PVC bedded galvanised steel or wire armored electric power cable (heavy duty) with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 2 core to be laid in existing cable trench/under road/along poles/through pipe etc complete all as specified and as directed. 300 RUNNING MMETRE
44 44 M & L for replacement of defective XLPE insulated screened PVC bedded galvanised steel or wire armored electric power cable (heavy duty) with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 4 core to be laid in existing cable trench/under road/along poles/through pipe etc complete all as specified and as directed. 200 RUNNING MMETRE
45 45 S & F in replacement of unsv isolator/MCB SPN 40 Amps with MCB DB 220 volts 2 way complete all as specified and as directed. 6 EACH
46 46 S & F in replacement of unsv isolator/MCB TPN 32 Amps with MCB DB 220 volts 4 way complete all as specified and as directed. 6 EACH
47 47 S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 100 LPD Non standard 1 No 2 EACH
48 48 S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 200 LPD Non standard 1 No and standard 1 No 2 EACH
49 49 S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 300 LPD Non standard 1 No and standard 2 No 2 EACH
50 50 S & F in replacement of broken/defective solar water heater storage tank for 100 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. 2 EACH
51 51 S & F in replacement of broken/defective solar water heater storage tank for 200 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. 2 EACH
52 52 S & F in replacement of unsv hot water out let hose pipe of standard length. 10 EACH
53 53 S & F in replacement of unsv cold water in let hose pipe of standard length. 10 EACH
54 54 S & F in replacement of broken/defective solar water heater storage tank for 300 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. 1 EACH
55 55 S & F in replacement of unsv/damaged Heating element with rubber gasket threaded /push type, 230 Volts, 1.5/2.00 KW and making necessary electrical connections, testing complete all as directed. Make of element : Toshiba/Bajaj or equivalent. 6 EACH
56 56 S&F inter locking ring, clip type suitble for rubber pipe complete all as directed. 40 EACH
57 57 M & L for cleaning of over head reservoir internally from base to top including scraping the mud silt from base and walls, washing the complete internal surfaces with bleaching powder, antibacterial sodium hypochlorite solution to inner surface with clean water ,removing the silt/mud water out side the tank and desilting from connecting pipes and applying internally one coat of lime wash to RCC walls ,base of tanks of 50000 gallons upto 30 mtrs staging complete & writing details of cleaning in prescribed format complete all as specified and as directed \nLocation : Pump House No 2 1 EACH JOB
58 58 Description all as per item Ser No 57 above but for 75000 gallons \nLocation : Pump House No 3 1 EACH JOB
59 59 Description all as per item Ser No 57 above but for 5000 gallons \nLocation : Tropo & Ops Area 2 EACH JOB
60 60 M&L for preparation of new wall/ plastered surfaces and applying two coats of cement base paint on RCC over head tanks upto 25 mtr height complete all as specified and directed by Engr-in-Charge 120 SQUARE METRE
61 61 M/L for two coats of synthetic enamel paint over a coat of red-oxide primer including preparation of old rusted surface of steel exc 10 cm width/grith at any height of tank and water supply vertical pipes of pumping and distribtion lines as per existing colour code and marking of Arrow for flowing of water with black/white paint complete all as specified and as directed. 10 SQUARE METRE
62 62 S & F in replacement of old unsv panel inbuilt star delta starter assembly complete suitable for 30/35HP sub mersible pumping set fixed in LT control panel of pump house including replacement of existing unsv panel wirings and accessories complete all as specified and as directed. Make : Havells/Schneider/ABB 4 EACH
63 63 S & F in replacement of water level indicator with sensor suitable for 75000 Galon over head RCC tank and making electrical connections and testing complete all as specified and as directed. 2 Each Set
64 64 S & F in replacement of damaged/unsv water level sensor with controller unit not less than 10 mtr where directed and testing upto the satisfaction of Engr-in-Charge. 2 Each Set
65 65 S & F in replacement of unsv injector dozing pump working in 230V single phase, 50 Hz, , flow rate 0-20 Ltr/Hr, Pressure - 10 Kg/cm2 where directed including making connections with existing dozing line and testing upto the satisfaction of Engr-in-Charge. \nMake : Sree Rayalaseema Hi-Strength Hypo Ltd/ Ramco 2 EACH
66 66 S & F in replacement of old unsv agitator motor, 120W, single phase, 220 V AC, 50 Hz, 6 pole, 960 PM where directed and testing upto the satisfaction of Engr-in-Charge complete all as specified and as directed. \nMake : Ravi Enterprises or equivalent in RAMCO/Decli-back.. 2 EACH
67 67 S & F in replacement of old unsv rotary switch of dozing pump (as per existing sample) and testing upto the satisfaction of deptt. 2 EACH
68 68 M & L for strip opening of submersible pumping set and prepare the surface for rewinding of burnt submersible pumping set of capacity 25/30HP capacity with the existing gauge of copper winding wire with same insulation including replacement of bearings complete all as per standard norms and testing upto the satisfaction of Engr in-charge. \nNote. Contractor shall give gurantee certificate for one year from the date of installation of motor. 1 EACH JOB
69 69 M & L Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot)\ncollars, caps and plugs upto 150mm bore for spigot socketed pipes. 100 KILOGRAM
70 70 M & L Bends. Tapers. Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150mm bore for flanged pipes. 100 KILOGRAM
71 71 Taking out old unserviceable 80mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). 200 RUNNING MMETRE
72 72 Taking out old unserviceable 50mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). 200 RUNNING MMETRE
73 73 Taking out old unserviceable 25mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). 150 RUNNING MMETRE
74 74 Taking out old unserviceable 20mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). 150 RUNNING MMETRE
75 75 M & L for GI pipe medium grade with all fittings laid in trenches 80mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n 150 RUNNING MMETRE
76 76 M & L for GI pipe medium grade with all fittings laid in trenches 50mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n 150 RUNNING MMETRE
77 77 M & L for GI pipe medium grade with all fittings laid in trenches 25mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n 100 RUNNING MMETRE
78 78 M & L for GI pipe medium grade with all fittings laid in trenches 20mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n 100 RUNNING MMETRE
79 79 Laying only, testing and connecting in trenches GI pipe 80mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge. Note:- GI pipe obtained from taking down shall be used. \n 50 RUNNING MMETRE
80 80 Laying only, testing and connecting in trenches GI pipe 50mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge. Note:- GI pipe obtained from taking down shall be used. . \n 50 RUNNING MMETRE
81 81 Laying only, testing and connecting in trenches GI pipe 25mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge. Note:- GI pipe obtained from taking down shall be used. \n 50 RUNNING MMETRE
82 82 Laying only, testing and connecting in trenches GI pipe 20mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge.Note:- GI pipe obtained from taking down shall be used. \n 50 RUNNING MMETRE
83 83 S & F Gun metal gate valve 50 mm ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe incl taking down old unserviceable complete all as specified and directed by Engineer-in-Charge. 5 EACH
84 84 S & F Gun metal gate valve 40 mm ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe incl taking down old unserviceable complete all as specified and directed by Engineer-in-Charge. 5 EACH
85 85 M&L for lead wool joints for 150mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. 5 EACH
86 86 M&L for lead wool joints for 100mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. 5 EACH
87 87 M&L for lead wool joints for 80mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. 5 EACH
88 88 M&L for run lead joints for 150mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. 5 EACH
89 89 M&L for run lead joints for 100mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. 5 EACH
90 90 M&L for run lead joints for 80mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. 5 EACH
91 91 Material & Labour for brick masonry valve pit internal size 1200mm x 1200mm x 1200mm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC plate form with 15cm off sets on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15mm thick plastering in cement mortar 1:4 and 50mm thick RCC cover (in two equal parts 1:2:4 type B-1 with 10mm dia deformed bars at 10cm interval on both side including necessary form work with 150mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge 2 EACH JOB
92 92 Description all as per ser item No 91 here-in-before but of size 900mm x 900mm x 900 -ditto- 2 EACH JOB
93 93 Description all as per ser item No 91 here-in-before but of size 600mm x 600mm x 600m -ditto- 2 EACH JOB
94 94 Supply and fixing in replacement of butterfly valve, lever operated, pressure rating PN-1.6, water type nitrile rubber lining, suitable insertion between flange ends, 150mm nominal bore ISI marked complete with MS tail pieces double side flanged incuding welding work as per site requirement, rubber/fiber board gasket, nut & bolt, washers etc complete all as specified and directed by Engr-in-Charge Make : BIR/L&T/ZOLOTO/Ramco 6 EACH
95 95 Description all as per ser item No 94 here-in-before but of 100 mm bore 8 EACH
96 96 Description all as per ser item No 94 here-in-before but of 80 mm bore 7 EACH
97 97 M & L for rubber gasket (Tyton) joints suitable for 150mm bore DI pipe and fittings including jointing material complete all as specified and as directed. 10 EACH
98 98 S & F flanged joints complete with rubber or fiberboard gasket , nuts, washers for 150mm bore pipe fittings complete all as specified and as directed. 5 EACH
99 99 Description all as per ser item No 98 here-in-before but of 100 mm bore 5 EACH
100 100 Description all as per ser item No 98 here-in-before but of 80 mm bore 5 EACH
101 101 Material & labour PCC 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate as in, foundation filling and mass concrete complete all as directed by Engineer-in-Charge 2 CUBIC METRE
102 102 Material and labout for masonry thrust block for 90 degree bend of size (30cm x 30cm x 60cm) complete all as directed by Engineer-in-Charge. 10 EACH