Military Engineer Services-MES has published Maint_Repairs_Replacement Of Certain Parts Of Cooling Appliances And Other Allied Works At Naval Base Porbandar. Submission Date for this Tender is 29-06-2020. Coats and Jackets Tenders in Porbandar Gujarat. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-06-2020 |
2 | 26-Jun-2020 | Corrigendum | Date | 29-06-2020 |
Name of Work: MAINT / REPAIRS / REPLACEMENT OF CERTAIN PARTS OF COOLING APPLIANCES AND OTHER ALLIED WORKS AT NAVAL BASE PORBANDAR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Material and labour for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas and commissioning and testing the window type air conditioner unit 1.5 Ton capacity complete all as specified and directed. | 8 | Job | |
2 | 2 | Ditto all as per item No 1.00 above but Cassette Type 2.0 Ton capacity | 1 | Job | |
3 | 3 | Ditto all as per item No 1.00 above but Cassette Type 3.0 Ton capacity | 1 | Job | |
4 | 4 | Ditto all as per item No 1.00 above but of Split type AC 1.5 Ton Capacity. | 80 | Job | |
5 | 5 | Ditto all as per item No 1.00 above but of Split type AC 2.0 Ton Capacity. | 50 | Job | |
6 | 6 | Ditto all as per item No 1.00 above but of Water cooler 40/60/80 Ltrs Cooling Capacity. | 15 | Job | |
7 | 7 | Ditto all as per item No 1.00 above but of Water cooler 120/150 Ltrs Cooling Capacity. | 4 | Job | |
8 | 8 | Ditto all as per item No 1.00 above but of Refrigerator 190/240 Ltrs. Capacity. | 2 | Job | |
9 | 9 | Ditto all as per item No 1.00 above but of Refrigerator 292/340 Ltrs. Capacity. | 5 | Job | |
10 | 10 | Ditto all as per item No 1.00 above but of Deep Frezzer 320 Ltrs. Capacity. | 2 | Job | |
11 | 11 | Material and labour for taking out window type Air conditioner 1.5 Ton capacity of any make from its original location, removing the dust from body with blower, cleaning the condenser and cooling coil by using water and caustic soda, painting the base tray with one coat of black enamel paint checking all the connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum etc. oiling/ greasing of fan motor checking serviceability and refixing it in its original place including testing commissioning for 1.5 Ton of AC of any make all as specified & directed by Engineer-in-Charge. | 6 | Job | |
12 | 12 | Ditto all as per item No 11 above but of split type AC 1/1.5/2.0 Ton capacity complete out door and indoor.\nNote for item Nos 11 & 12 :Refrigerant gas will be measured & paid separately . | 180 | Job | |
13 | 13 | M&L for shifting of split AC from existing location to new location including making good of old location and Fixing, connecting and testing only split type room air conditioner ,copper condensing coil with wall mounted indoor unit, Outdoor (condensing) unit incl. copper tube refrigerant piping duly insulated, condensate water outlet pipe and 3 core copper wire from connection upto unit as directed and specifiedand directed by Engineer-in-Charge. | 15 | Job | |
14 | 14 | Material and labour for taking down Corroded body base tray etc of window type air conditioners and replacement of body base tray etc out of 18 SWG and other portion with MS sheet 20 SWG including motor mounting frame nuts and bolts suitable size painting and necessary insulation complete for 1.5 Ton capacity Air conditioner.\n(Note : For dismantling compressor for body work and reassembling and gas charging as per site requirement shall be inclusive in quoted rate) | 1 | Job | |
15 | 15 | Material and labour for preparation of old painted surfaces of Refrigerator any capacity by complete scraping old painting an applying two coats of synthetic enamel paint on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed. | 4 | Job | |
16 | 16 | Material and labour for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coats of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed. | 12 | Job | |
17 | 17 | Supply, install, test & commissioning new compressor sealed reciprocating type suitable for window type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas etc. complete all as specified & directed by Engineer-in-Charge. \nMake : Voltas/usha Shriram / Bluestar / Samsung / Hitachi / Videocon/LG/Carrier etc. as per existing make at site. | 2 | Each | |
18 | 18 | Ditto all as per item No 17.00 above but Cassesste type 2.0 Ton capacity | 10 | Each | |
19 | 19 | Ditto all as per item No 17.00 above but of Split type AC 1.5 ton capacity | 10 | Each | |
20 | 20 | Ditto all as per item No 17.00 above but of Split type AC 2.0 ton capacity | 10 | Each | |
21 | 21 | Ditto all as per item No 17.00 above but of Cassesste type AC 3.0 ton capacity | 1 | Each | |
22 | 22 | Ditto all as per item No 17.00 above but of Refrigerator 190/240 Liters Capacity. | 1 | Each | |
23 | 23 | Ditto all as per item No 17.00 above but of Refrigerator 292/340 Liters Capacity. | 1 | Each | |
24 | 24 | Ditto all as per item No 17.00 above but of Water coolers 40 / 60 /80 Liters cooling capacity | 2 | Each | |
25 | 25 | Ditto all as per item No 17.00 above but of Water coolers 150 Liters Cooling capacity | 1 | Each | |
26 | 26 | Ditto all as per item No 17.00 above but of deep freezers of capacity 320 ltrs Capacity | 1 | Each | |
27 | 27 | Removing the existing unserviceable burnt fan motor from window/Split type AC of capacity 1.5/2 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete. | 15 | Each | |
28 | 28 | Supply and fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete. | 6 | Each | |
29 | 29 | Supply,fixing and testing fan blade suitable for window/split type Air conditioner of 1.5 / 2.0 Ton capacity including removing old fan blade. | 30 | Each | |
30 | 30 | Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old fan blade. | 6 | Each | |
31 | 31 | Replacing old defective blower drum and supply & fix blower drum suitable for window type Air conditioner of 1.5 Ton / 2.0 Ton capacity. | 4 | Each | |
32 | 32 | Replacing old defective blower drum and supply & fix blower drum suitable for split type Air conditioner of 1.5 Ton / 2.0 Ton capacity. | 25 | Each | |
33 | 33 | Replacing old defective blower motar and supply & fix blower motar suitable for split type Air conditioner of 1.5 Ton / 2.0 Ton capacity. | 20 | Each | |
34 | 34 | Replacing old defective Swing motar and supply & fix Swing motar suitable for split type Air conditioner of 1.5 Ton / 2.0 Ton capacity. | 12 | Each | |
35 | 35 | S & F in repairs front cover grill suitable for window type AC 1.0 Ton / 1.5 Ton / 2.0 Ton capacity AC of various makes. | 2 | Each | |
36 | 36 | S & F in repairs starting capacitor 60 - 80 mfd. Make:(ANAND/UNIQUE/ KELTRON) | 30 | Each | |
37 | 37 | S & F in repairs starting capacitor 80-100 mfd. Make:(ANAND/UNIQUE/ KELTRON) | 25 | Each | |
38 | 38 | S & F in repairs of starting capacitor 100 -120 mfd. Make: ANAND/UNIQUE/ KELTRON) | 15 | Each | |
39 | 39 | S & F in repairs running capacitor 25 MFD.\n(Make : Asian / Epcos) | 20 | Each | |
40 | 40 | S & F in repairs running capacitor 36 MFD.\n(Make : Asian / Epcos) | 35 | Each | |
41 | 41 | S & F in repairs running capacitor 45 MFD.\n(Make : Asian / Epcos) | 25 | Each | |
42 | 42 | Supply and fix in replacement of selector switch push button type for window type AC any make 1.0 Ton / 1.5 Ton / 2.0 Ton capacity (Make : Arvind / Usha) | 2 | Each | |
43 | 43 | Ditto all as per item No 41.00 above but rotary type | 1 | Each | |
44 | 44 | Supply and fix in replacement of thermostat switch for window type AC of capacity 1.5 Ton capacity.\n(Make :- Indofoss / Ranutral) | 2 | Each | |
45 | 45 | Supply and fix in replacement of thermostat switch for split type AC of capacity 1.5 Ton / 2.0 Ton capacity (Make :- Indofoss / Ranutral) | 20 | Each | |
46 | 46 | Supply and fix in replacement of thermostat switch for Refrigerator of any capacity.\n(Make :- Indofoss / Ranutral) | 4 | Each | |
47 | 47 | S&F in repairs of thermostat switch for Water Cooler of any capacity.\n(Make :- Indofoss / Ranutral) | 4 | Each | |
48 | 48 | S & F in repairs over load relay suitable for Window type AC of 1.5 Ton Ton capacity all as directed.\n(Make : Arvind / Usha / Rametrol) | 2 | Each | |
49 | 49 | S & F in repairs over load relay suitable for water cooler of any capacity all as directed.\n(Make : Arvind / Usha / Rametrol) | 8 | Each | |
50 | 50 | S & F in repairs over load relay suitable for Refrigerator of any capacity all as directed.\n(Make : Arvind / Usha / Rametrol) | 4 | Each | |
51 | 51 | S & F in repairs Float valve suitable for Water cooler of any capacity | 4 | Each | |
52 | 52 | S & F in repairs and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete. | 80 | RM | |
53 | 53 | Supply and laying in repairs cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as directed by Engineer-in-Charge | 50 | RM | |
54 | 54 | Supply and laying in repairs PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete. | 50 | RM | |
55 | 55 | S & F in repairs push cock / lifting cock of 15 mm bore for water cooler of any capacity | 6 | Each | |
56 | 56 | S & F in repairs PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers | 10 | Job | |
57 | 57 | S & F in repairs GI water tray 2 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe. | 10 | Each | |
58 | 58 | S & F in repairs PVC drain pipe with necessary saddles of 25 mm size to be used as out let drain to be fixed etc all as per direction of Engineer-in-Charge | 100 | RM | |
59 | 59 | S & F in repairs sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps etc all as specified & directed by Engineer-in-Charge. | 10 | Each | |
60 | 60 | S & F in repairs magnetic gasket for refrigerator of 190/240/292/340 liters complete all as directed by Engineer-in-Charge. | 2 | Each | |
61 | 61 | Taking out old unserviceable condenser coil of 1.5 Ton window type AC any make with sins cutting in let outlet connecting copper pipe and providing new condensor coil with sins and connecting inlet outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
62 | 62 | Ditto all as per item No 60.00 above but for 1.5 ton Split type AC complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
63 | 63 | Ditto all as per item No 60.00 above but for 2.0 ton Split type AC complete all as specified and directed by Engineer-in-Charge. | 12 | Each | |
64 | 64 | Removing electronic unserviceable circuit boards from window type AC 1.5 ton capacity and replacing with new circuit boards and connecting with system with replacing remote control hand set and testing complete all as specified and directed | 2 | Each | |
65 | 65 | Ditto all as per item No 63.00 above but for 1.5 Ton / 2.0 Ton Split type AC complete all as specified and directed | 10 | Each | |
66 | 66 | S & F in repairs blower fan motor capacitor 4 MFD (Make : Asian / Keil) | 15 | Each | |
67 | 67 | S & F in repairs blower fan motor capacitor 6 MFD (Make : Asian / Keil) | 20 | Each | |
68 | 68 | S & F in repairs electric bulb suitable for refrigerator of any capacity screw type / pin type.\n(Make :- Philips / Equivalent) | 2 | Each | |
69 | 69 | S & F in repairs Air filter for window type AC of any capacity and type by Engineer-in-Charge. | 2 | Each | |
70 | 70 | Material and labour for replacement of damaged outer cover for window type Air conditioner of any capacity and size made out of aluminium sheet of 20SWG all as specified by Engineer-in-Charge. | 2 | Job | |
71 | 71 | S & F in repairs over load protector for 1.5 /2.0 Ton capacity window type Air Conditioner. \n(Make : Usha/ Ranutral). | 2 | Each | |
72 | 72 | Cutting of existing wall / window grills / frame for making suitable space to accomodate window AC making frame with 2 nd class hard wood piece of min of 50 X 50 mm size and up to 60 cm height for fixing of outer cover of AC and supporting structure made out 40 mm X 40 mm X 5 mm thick MS angle iron dully grouted in wall and closing the open space around ACs with the help of 6 mm thick ply wood exterior grade to close air leakage tightening with wooden left ( green felt) and painting to wooden structure matching to interiors as directed and steel structure with one coat of primer and two coats of synthetic black enamelled paints and fixing only window type AC all as directed by engr- in charge including complete connecting and testing all as specified and directed by engr in charge. | 4 | Job | |
73 | 73 | Ditto all as per item No-70 but shifting of AC from Existing location to new location including making good of old location all as specified and directed by Engr-in- charge. | 8 | Job | |
74 | 74 | S & F in repairs multipurpose door lock with duplicate key of refrigerator of any make & capacity etc complete all as specified and directed by Engineer-in-Charge. | 4 | Each | |
75 | 75 | Taking out old unserviceable cooling coil of window/split type AC any capacity and any make with sins cutting inlet outlet connecting copper pipe and providing new cooling coil with sins and connecting inlet outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge. | 15 | Each | |
76 | 76 | S & F in repair wiring kit for capacity 1.5/2.0 ton AC Make :- Tecumesh/Sri Ram/Hi Tech/Aanutrol | 8 | Each | |
77 | 77 | Supply and fix in replacement of Switch socket combination 2 in 1, 3 pin , 5 and 15 Amps flush type universal complete all as specified. | 40 | Each | |
78 | 78 | Supply and fix in replacement of socket 6/16A - 2/3 pin combined 2 module universal complete all as specified. | 15 | Each | |
79 | 79 | Supply and fix in replacement of moduler switch 1 way 16 A1 module complete all as specified. | 15 | Each | |
80 | 80 | supply and fixing in replacement of plug top , single pole and neutral enclosure with plug and socket complete with one single pole MCBs of cap 20 Amps. | 30 | Each | |
81 | 81 | S & F Sheet Metal Encloser with socket plug top , single pole and neutral enclosure with plug and socket complete with one single pole MCBs of capacity 20 Amps . | 30 | Each | |
82 | 82 | M & L in replacement of submain wiring ( in PVC Casing caping ) with 2 Runs of 4 sq mm FR PVC insulated multi stranded copper cable 1100 V grade along with one run of 2.5 sq mm copper cable for earth comtinuity wire connected to common earth dolly ( coloure code to be followed) drawn through 20 mm dia medium grade PVC conduit including accessories complete all as specified and directed. | 100 | RM | |
83 | 83 | S & F in repair foam type insulating flexible pipe for suction tubes of 1.5/2 Ton capacity split AC. \nMake :- As per sample | 100 | RM | |
84 | 84 | S & F in repairs furnace contactor 24 V AC,2 pole,30 Amps of split ac 1.5/2 type & capacity. | 8 | Each | |
85 | 85 | S & F in repairs filter Catridge suitable 8 to 25 ltrs RO Plant . | 40 | Each | |
86 | 86 | S & F in repairs Carbon filter Catridge suitable 8 to25 ltrs RO Plant . | 10 | Each | |
87 | 87 | S & F in repairs filter Catridge suitable 25 to 50 ltrs RO Plant . | 12 | Each | |
88 | 88 | S & F in repairs Membrane for reverse osmosis of upto 25 Ltrs for RO Plant | 24 | Each | |
89 | 89 | S & F in repairs Diaphragm pump, 24V DC,Rated Current 2.6 Amp,inlet pressure 30 Psi | 4 | Each | |
90 | 90 | S & F in repairs SMPS Adaptor ,230 V AC,50 Hz,24 V DC,3 Amp | 3 | Each | |
91 | 91 | S & F in repairs Flow Restrictor suitable for RO Plant 25 Ltrs Capacity | 3 | Each | |
92 | 92 | S & F in repairs Solenoid Valve,24V AC,0-0.7 Mpa suitable for RO Plant 25 Ltrs Capacity | 3 | Each | |
93 | 93 | S & F in repairs Tube Roll of size 1x 1/4 " Suitable for RO Plant upto 25 Ltrs Capacity | 50 | RM | |
94 | 94 | S & F in repairs Tube Jointer of size 1x 1/4 " Suitable for RO Plant upto 25 Ltrs Capacity | 6 | Each |