Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #24506697

Special Repair Of Taxiway/Air Field Lighting System At Ir And O And Provn Of Ups With Allied Works At Hq Nc Complex Under Ge Utilities Udhampur

Issued by Statutory Bodies & Commissions/Committees · UDHAMPUR, Jammu And Kashmir
Tender Value
15.70 Lakhs
Estimated cost
Bid Submission
25 Aug 2020
0 days left
EMD
31400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
UDHAMPUR → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repair Of Taxiway/Air Field Lighting System At Ir And O And Provn Of Ups With Allied Works At Hq Nc Complex Under Ge Utilities Udhampur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Jun-2020 REVISED DATES Date 06-Jul-2020
2 26-Jun-2020 RE-REVISED DATES Date 13-Jul-2020
3 06-Jul-2020 RE-REVISED DATES OF BID SUBISSION START AND END DATES Date 20-Jul-2020
4 10-Jul-2020 RE-REVISED DATES_4 Date 27-Jul-2020
5 18-Jul-2020 RE-REVISED DATES_5 Date 04-Aug-2020
6 28-Jul-2020 RE-REVISED DATES_6 Date 25-Aug-2020

BOQ

Name of Work: Speical repair of Taxiway/Air field lighting System at IR&O and provn of UPS with allied works at HQ NC complex under GE Utilities Udhampur
Ser.No.Item DescriptionItem Code / MakeQuantityUnits
11Disconnection and taking down of the existing old unserviceable cable of size 10 sqmm 2 core complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011321200RM
22Supply, laying,jointing and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011331200RM
33Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.BI01010001010000000000000515BI0100001134162Cum
44Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.BI01010001010000000000000515BI010000113583Cum
55Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.BI01010001010000000000000515BI010000113679Cum
66M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI010000113765Cum
77M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011387Per 1000 Nos
88S&F tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads of 40 mm bore complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI010000113990RM
99M&L for road cutting for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.BI01010001010000000000000515BI010000114013RM
1010M&L for plain cement concrete(1:2:4)type B1(using 20 mm graded aggregate)as in footings for poles etc including necessary form work complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011412Cum
1111M&L for circuit wiring with PVC cable FRLS copper conductor LT 1100 volts, twin core 2.5 sqmm multistranded wire for connection of various lights complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI0100001142170RM
1212M&L for MS box of size 25x20x10 cm comprising of four strips aluminium bus-bars 30 Amps, made out of 18 gauge mild steel sheet, front opening shutter with locking arrangement including fixing accessories such as clamps, nuts and bolts etc or embedded in PCC and two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI010000114371Each
1313Disconnection and taking down of the existing old unserviceable light along with complete accessories complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI010000114471Each
1414S&F Airport LED Taxiway Light of 7 Watt,temperature -40 to +55 degree C,having Lens of yellow colour,having current 2.8 to 6.6 amps with complete accessories incl necessary connection complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI010000114550Each
1515S&F Airport LED Taxiway Light of 7 Watt,temperature -40 to +55 degree C,having Lens of Blue colour,having current 2.8 to 6.6 amps with complete accessories incl necessary connection complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011466Each
1616S&F Aviation Obstruction light (Red type) with single Emitter Absored cover Cast alu (LM-6) housing weather proof IP-65, painted with corrosion resistant yellow paint, covered by hard ABS red cover dome & sealed with gasket, long life & energy saving LED based lamp, solid state ultra red LED, Power 15 Watt along with accessories incl necessary connection complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI010000114714Each
1717S&F Floor Mount Electronic Dimmer 3 phase, suitable for input voltage 220/240V, 50 HZ , Remote in 0 to +10 volts analogue 36 pin centronics connector or 3 pin XLR connector in case suitable for Runway lighting along with accessories as recommended by manufacture incl necessary connection complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011481Each
1818S&F On Line UPS for 30 min backup three phase AC input 300 to 450 V and out put single phase AC output voltage 230+/- 1% of capacity 20 KVA incl all necessary connection complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011491Each
1919Disconnection & taking down old U/S LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-BI01010001010000000000000515BI01000011501Each
2019.01(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 500 amps for Phases neutral - 01 set\n(b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos\n(c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job\nIncoming: -\n(a) MCCB 4 pole , Ics=75%Icu- 25/27 KA, 415 Volts, 400 Amps , with thermal adjustable and magnetic setting with extended terminals -01 Nos.\n(b) Front operated on load chang over switch 200 Amp 4 pole, 50 Hz, 415 volt - 01 No.\nOutgoing: -\n(a) MCCB 4 pole , Ics=75%Icu- 16/18 KA, 415 Volts, 200 Amps , with fixed thermal aad fixed magnetic setting with extended terminals -02 Nos.\n(b) MCB DP 32 Amps - 20 Nos.\n(c) MCB DP 63 Amps - 10 Nos.\n(d) PCC 1:3:6 type C-2 for grouting 4 legs of feeder pillar box.\nNote: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.BI01010001010000000000000515BI0100001151
2120Disconnection & taking down old U/S LT Panel and Supply , installation, testing and commissioning of outdoor type,weather proof, LT panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-BI01010001010000000000000515BI01000011521Each
2220.01(a) Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 300 amps for Phases neutral - 01 set \n(b) Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos\n(c) Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job\nIncoming: -\n(d) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -1 No.\nOutgoing: -\n(a) MCB DP 32 Amps - 06 Nos.\n(b) MCB TPN 63 Amps - 06 Nos.\n(c) MCB SP 32 Amps - 20 Nos.\n(d) PCC 1:3:6 type C-2 for grouting 4 legs of feeder pillar box.\nNote: - Various feeder shall be indicated by 50 mm high letter in white synethetic enamel paint.BI01010001010000000000000515BI0100001153
2321Disconnection & taking down old U/S LT Panel and M&L for factory made sheet metal encloser (junction pannel) made out of 3.15 mm thick CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 120X75X45cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of lengh 75 cm of 400 amps capacity, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011541Each
2422M&L for providing earthing with GI earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the earth plate not less than 1.5 m below ground level connected to GI strip 32 x 6 mm thick for earthing lead fixed by means of nuts, bolt, washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge.\nNote: - All the joints shall be made with welding to get proper conductivity.BI01010001010000000000000515BI01000011557Each
2523S&F UPS for 30 min backup single phase AC input 160 to 260 V and output 230 V+ 1% of capacity 5 KVA complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011561Each
2624M&L for sub main wiring with two single core PVA insulated FRLS cables with stranded copper conductors 4 sqmm, 450/1100 volts grade on existing PVC conduit medium grade complete with conduit accessories and copper cable 2.5 sqmm continous earth wire complete all as specified and directed by Engr-in-Charge.(Two runs of cable with 01 earth wire shall be measured as one length.BI01010001010000000000000515BI010000115720RM
2725S&F MCB SPN 32/63 Amp C cure complete all as specified and directed by Engr-in-Charge.BI01010001010000000000000515BI01000011581Each

AI Tender Summary

OUR REF NO 24506697
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 15.70 Lakhs
LAST DATE 25-08-2020
Authority
Authority Name Military Engineer Services
Work Description Special Repair Of Taxiway/Air Field Lighting System At Ir And O And Provn Of Ups With Allied Works At Hq Nc Complex Under Ge Utilities Udhampur
Basic Detail
Tender No GE/U-15/2020-21
Bidding Type Tender
Location
City UDHAMPUR
State Jammu And Kashmir
Key Dates
Publish Date 28 Jul 2020
Submission Date 25 Aug 2020
Open Date 27 Aug 2020
Finance
Tender Value 15.70 Lakhs
Tender Fee 500
EMD 31400
Exemption Not Available
Document List
153F4CEF-9E15-4886-AE2E-5FD6646593AA.html
Tendernotice_1.pdf
BOQ_391170.xls
Tender15.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 28, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 06, 2020
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 13, 2020
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 20, 2020
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 27, 2020
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 04, 2020
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 25, 2020
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 25, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 27, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

153F4CEF-9E15-4886-AE2E-5FD6646593AA.html

pdf

Tendernotice_1.pdf

xls

BOQ_391170.xls

pdf

Tender15.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders