Operation And Maintenance Of E And M Installations , 11 Kv Substation , Dg Sets , At Sia Operation And Maintenance Of E And M Installations , 11 Kv Substation , Dg Sets , Int . And Ext . Ei Etc In Non Operational Area At Srinagar International Airport , Srinagar . ( For The Year 2020-21 And 2021-22 ) , Running , Operation And Day To Day Maintenance Of Various E&M Installations Of 11 / 0 . 433 Kv Main Sub-Station , Residential Area Sub-Station Like Ht & Lt Panels , Transformers , Dg Sets ( Different Capacities ) With Amf Panel , Car Parking Flood Lights & Street Lights , Feeder Pillars , Main And Residential Area , Water Pump House ( I / C Cargo , Powerhouse & Aai Colony ) , Aai Residential Quarters , Crpf / Jkp Barracks , Drop Gate Etc On All Days I / C Saturdays , Sundays , Gazetted Holidays & National Holidays In Three Shifts ( Round The Clock ) I / C Record Keeping Etc To The Entire Satisfaction Of The Engineer-In-Charge By Deploying The Following Minimum Man Power . ( I ) Supervisor ( Highly Skilled ) :- 02 Nos . ( In General Shift ) ( Ii ) Dg Operator ( Skilled ) :- 04 No . ( 01 No In Each Shift For Three Shifts + 01 Reliever ) ( Iii ) Electrician / Wireman ( Skilled ) :- 08 Nos . ( 02 Nos In Each Shift For Three Shifts + 01 No In General Shift + 01 Reliever ) ( Iv ) Pump Operator ( Skilled ) - 08 Nos ( 02 Nos In Each Shift For Three Shifts +01 No In General Shift + 01 Reliever ) ( V ) Helper ( Un-Skilled ) :- 08 Nos . ( 02 Nos In Each Shift For Three Shifts + 01 No In General Shift + 01 Reliever ) . , Dehydration Of Transformer Oil In Order To Improve The Bdv Upto 60 Kv For 1 Minute By Deploying The Filtration Plant At Site I / C Testing Of Bdv Of Oil Before And After Filtration . , Testing & Calibiration Of Protective Relays By Secondary Current Injection Method & Checking The Tripping Of Breakers On Actuation Of The Relay And Submission Of Reports Thorugh Specialised Agency / Service Center . , Earthfault Protection Digital Relay . ( L&T / Abb Make ) , Idmt Earth Fault Protection Relay . , Auxilary Relays . , Servicing Of Ht 11 Kv 800 Amps Vcb I / C Cleaning Of Dust Removing Of Oxidation Layers From The Exposed Auxilary Controls , Closing & Opening By Electrical / Manual Operations Checking Ct & Pt Control & Meeting Circuit & Making Minor Adjustements If Required , Lubricating The Moving Mechanisim Like Spring Charging & Raking In & Out Of Breaker Trolley ( 02 Nos Abb Make & 03 Nos Crompton Make Vcb ) And Submission Of Reports Thorugh Specialised Agency / Service Center . ( Excluding Cost Of Spares ) , Checking & Servicing Of Lt Acbs Of Following Makes & Rating At Site By Dismantling The Breaker , Cleaning & Degreasing , & Lubrication Of Various Moving Mechanism Checking Of Control Circuit Of The Breaker Etc And Recommissioning Of Same And Submission Of Reports Thorugh Specialised Agency / Service Center . ( Excluding Cost Of Spares ) . , 800 Amp , 4 Pole Acb Of Merlin Gerin Make . , 1600 Amp , 4 Pole Acb Of Merlin Gerin Make . , 800 Amp , 4 Pole Acb Of Ge Make . , 1000 Amp , 4 Pole Acb Of Ge Make . , 1600 Amp , 4 Pole Acb Of Ge Make . , 2500 Amp , 4 Pole Acb Of Ge Make . , 1600 Amp , 4 Pole Acb Of Abb Make . , 1600 Amp , 4 Pole Acb Of L&T Make . , 800 Amp , 4 Pole Acb Of L&T Make . , Rewinding Of The Following Type Of Fans I / C Replacement Of Bearing / Bush By Dismantling , Transportation To Workshop & Back And Reinstallation Of Fan At The Existing Location I / C Connection , Testing & Commissioning Etc Complete As Required . ( Dismantled Material Shall Be The Property Of Tenderer ) , Ceiling Fan Of All Makes And Models . , Exhaust Fan Of All Makes And Models . , Painting Of Following Installations In Installed Position With Synthetic Enamell Paint By Spray / Brush Painting With One Or More Coats To Give An Even Finish I / C Scraping , Cleaning & Preparing The Surface Etc Complete As Required . , Distribution Boards / Electrical Panels / Feedar Piller Etc . , Street Light Poles With Single / Double Arms , Height Upto 4 Mtrs . , Street Light Poles With Single / Double Arms Of Height Above 7 Mtr To 9 Mtrs , Lifitng & Lowering The Submersible Water Pump Upto 10 Hp For Repair / Replacement In The Exisitng Borewell By Using Chain Pully Block & Tripod Etc . I / C Replacement Of The Gaskets And Worn Out Nut , Bolt Etc . Complete As Required . , Carrying Out The Works Covered Under Dsr ( Electrical ) 2018 , Of Value Upto Rs 5 , 00 , 000 / -- ( Five Lakh Only ) The Payment Of Dsr Items Shall Be Released On The Basis Of Perctange Above / Below Quoted On Rs 5 , 00 , 000 / - Note: Guiidline For Quoting %Age Rate For The Bidder . 1 . The Bidder Has To Quote The Rates In The Rates Column Aganist The Works Of Rs . 500000 / -Of Dsr 2018 ( Electrical ) And Same Shall Be Converted Into %Age Above / Below On The Dsr 2018 ( Considering The Rates Of Dsr 2018 As Base Rates ) . 2 . For Example If Bidder Quotes Rs . 525000 / - In Rates Column Then Same Shall Be Converted Into %Age Of Dsr 2018 As Under ( ( 525000 - 500000 ) / 500000 ) I . E . 5% Above On Dsr 2018 And Accordingly Payment Shall Be Made By Applying The %Age I . E . 5% Above On Dsr 2018 Rates For Items Covered In Dsr 2018 .