Airports Authority Of India has published Annual Repair And Maintenance Of Of Electro And Mechanical Installations At B . M . Airport , Ranchi Sh Providing Maintenance Services For E And M Installations Of Operational Area And Technical Block For The Year 2020-2022. Submission Date for this Tender is 15-06-2020. Electromechanical Services Tenders in AAI,BM,Airport,Ranchi Jharkhand. Bidders can get complete Tender details and download the document.
Name of Work: : ARMO E & M Installations at B. M. Airport, Ranchi. SH: Providing Maintenance Services for E&M Installations of Operational Area and Technical Block for the Year 2020-2022. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Sub Head - I Operation and Maintenance - Man power\nRequirement.\n\nProviding Operation and Maintenance Services of Electrical & Mechanical Installations monthly at entire Operational Area includes Old & New ATC cum Technical Block, Fire station, Navaids, STP building, Hangars (For availing source of power supply only) comprising GLF Systems, CCRs, 03 nos. DG Sets upto 500 KVA with AMF Panels, Power Supply Distribution Systems, Transformers upto 630 KVA, Water Pump Sets, Lifts, High Mast Towers, Flood Lights, Street Lights, Perimeter Road Lights , Fire Hydrant System (only operations), HVAC-VRV system (only operations) all Internal & External E. I. works, Old & New ATC power houses, Fire station, i/c 33 KV HT panel, all LT panels & Feeder pillars, APFC panel, ALCMS, UPSs (2 nos x80 KVA and 2 nos x180 KVA) including other minor ancillary & related installations covering the scope of operations, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satifactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintenance of records/documentation etc. as per scope of work given in special conditions and technical specifications of contract on all days including Sundays & Holidays. The services of DG Sets, AMF Panels at power houses and the services of all other E & M installations shall be ensured round the clock (ie. in three shifts daily, each shift of 8 hours) as per specification and as required. (Minimum Manpower engaged shall be as per special condition of contract and particular specification of contracts) | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Ist Year | BI01010001010000000000000515BI0100001113 | 12 | Month |
3 | 1.02 | II nd Year | BI01010001010000000000000515BI0100001114 | 12 | Month |
4 | 2 | Sub Head - 2 Miscellanious seruices\n\nTesting BDV value of transformer oil in presence of AAI representative | BI01010001010000000000000515BI0100001112 | ||
5 | 2.01 | Ist Year | BI01010001010000000000000515BI0100001121 | 5 | each |
6 | 2.02 | II nd Year | BI01010001010000000000000515BI0100001122 | 5 | each |
7 | 3 | Dehyderation and filtration of transformer oil at site including testing for\nBDV value after dehydration and filtration and submission of test reports\netc. complete as required. | BI01010001010000000000000515BI0100001112 | ||
8 | 3.01 | Ist Year | BI01010001010000000000000515BI0100001125 | 3000 | ltrs |
9 | 3.02 | II nd Year | BI01010001010000000000000515BI0100001126 | 3000 | ltrs |
10 | 4 | Servicing, maintenance and testing of L & T make Air Circuit Breaker\nup tol000A complete as required. | BI01010001010000000000000515BI0100001112 | ||
11 | 4.01 | Ist Year | BI01010001010000000000000515BI0100001127 | 10 | each |
12 | 4.02 | II nd Year | BI01010001010000000000000515BI0100001128 | 10 | each |
13 | 5 | Servrcing, maintenance and calibration of earth fault and over load relay\nwith secondary injection kit etc. of 02 nos. HT panel of Jyoti make\ncomDlete as required. | BI01010001010000000000000515BI0100001112 | ||
14 | 5.01 | Ist Year | BI01010001010000000000000515BI0100001127 | 2 | each |
15 | 5.02 | II nd Year | BI01010001010000000000000515BI0100001128 | 2 | each |
16 | 6 | Servicing, maintenance and testing of 33 kV HT - Vaccum Circuit\nBreaker ofjyoti make etc. complete as required.\n | BI01010001010000000000000515BI0100001112 | ||
17 | 6.01 | Ist Year | BI01010001010000000000000515BI0100001127 | 2 | each |
18 | 6.02 | II nd Year | BI01010001010000000000000515BI0100001128 | 2 | each |
19 | 7 | Repair and rewinding of submersible pump motor upto 5 HP Job includes transportation of motor, dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn-out/ defective parts i.e. bushes, impellers, sleeves, upper and lower bush sets, thrust bearings, oil seals, rotor grinding and balancing , assembling, testing, transportation etc. complete as required. | BI01010001010000000000000515BI0100001128 | 4 | job |
20 | 8 | Lifting and lowering of submersible pumps of various capacities (upto 5 HP) due to defect in existing pump on urgent basis within a short notice including connection of cable, jointing of cable etc with successful testing & commissioning complete as required. | BI01010001010000000000000515BI0100001128 | 4 | job |
21 | 9 | Repair and overhauling of AMF panels i/c Checking of control circuits, interlocking , checking of healthiness of all components including AMF Relays etc as complete and as per direction of EIC(Faulty spares to be provided by AAI ) | BI01010001010000000000000515BI0100001128 | 1 | job |
22 | 10 | Sub Head - 3 Supply of general electrical Materials as and when\nrequired.\n\nSupply of Flame Retardant Low Smoke & Halogen FR-LSH PVC Insulated Industrial Cables of following sizes Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed)\nFlexible Cables, 1100 Volts Conforming to IS: 694 (Each Roll of 90 Mtrs) | BI01010001010000000000000515BI0100001112 | ||
23 | 10.01 | I Core 1.5 Sq. mm. | BI01010001010000000000000515BI0100001127 | 15 | roll |
24 | 10.02 | I core2.5 sq.mm. | BI01010001010000000000000515BI0100001128 | 15 | roll |
25 | 10.03 | I core 4 sq.mm. | BI01010001010000000000000515BI0100001128 | 10 | roll |
26 | 11 | Supply of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 (Each Roll of 100 Mtrs) | BI01010001010000000000000515BI0100001112 | ||
27 | 11.01 | 3 core 2.5 sq.mm. | BI01010001010000000000000515BI0100001127 | 4 | roll |
28 | 11.02 | 3 core 4 sq.mm. | BI01010001010000000000000515BI0100001128 | 4 | roll |
29 | 12 | Supply of 90 W LED street Light fittings cool white | 20 | each | |
30 | 13 | Supply of 3HP submersible pump set make KSB, model UMAI 100-\n2.2122 or equivalent | 2 | each | |
31 | 14 | supply of wll mounted fans 300 mm sweep | 10 | each | |
32 | 15 | supply of medium intensity Aviation obstruction light for 230 V system | 5 | each | |
33 | 16 | Supply of following size XLPE insulated and PVC sheatheed, armoured Aluminum conductor power cable of 1.1 KV grade conforming to IS-7098 (part-1) 1988 with upto date amendments. 3.5 x 185sq mm | 500 | mtrs | |
34 | 17 | 12V constant voltage converter drive for LED signages 60W | 10 | each | |
35 | 18 | 12V constant voltage converter drive for LED signages 120W | 10 | each | |
36 | 19 | LED strip 0.2W X 144 per strip of I meter | 50 | mtrs | |
37 | 20 | SH:4 supply of Airfield materials i/c GLF\n\nSupply of following GLF items as per latest ICAO specifications | BI01010001010000000000000515BI0100001112 | ||
38 | 20.01 | 200w 6.6 A holagen Lamp Runway lamp | 200 | each | |
39 | 20.02 | 105 w 6.6 A BIPIN (Inset ) Halogen Lamp | 50 | each | |
40 | 20.03 | 200 W 6.6 A Elevated Approach Fiting lamp | 50 | each | |
41 | 20.04 | Runway Larnp Holder (Flate end tenninal ) | 50 | each | |
42 | 20.05 | 6 sq.mm ESSNA -kit (copper ) 5kv grade | 50 | each | |
43 | 20.06 | 16 sq.mm 5 KV Grade plug &Recaptable (ESSNA Kit)(copper) | 100 | each | |
44 | 20.07 | Secondary 2 Pin lead of 0.3 mtr Length | 50 | each | |
45 | 20.08 | Two Pin Secondary Plug Assembly for PAPI (2.5 Mtr long) | 50 | each | |
46 | 20.09 | Base Plate Gaskets | 50 | each | |
47 | 20.1 | LED Signage Converter capable to drive LED strip of 0'5w for\nooerational area signages | 20 | each | |
48 | 20.11 | LED Signage Strip of 0.5w make osram or equivalent | 50 | each | |
49 | 20.12 | LED Type Taxi Fitting as per latest ICAO standards | 25 | each | |
50 | 20.13 | breakable coupling for GLF light fittings | 20 | each | |
51 | 21 | Supply of SCR /Thyrister for NASU CCR | BI01010001010000000000000515BI0100001112 | ||
52 | 21.01 | 85 RK 160 SCR/thyrister for 7.5kw NASU make CCR | 4 | each | |
53 | 21.02 | 250RK 160 SCR/thyristor for 30kw NASU make CCR | 4 | each | |
54 | 22 | Supply of Isolating Transformer as per ICAO | BI01010001010000000000000515BI0100001112 | ||
55 | 22.01 | Isolating Transformer200w 20/6.6 A | 50 | each | |
56 | 22.02 | Isolating Transformer200w 6.6/6.6 A | 20 | each | |
57 | 22.03 | Isolating Transformer 45w 20/6.6 A | 10 | each | |
58 | 22.04 | Isolating Transformer 45w 6.6/6.6 A | 10 | each | |
59 | 22.05 | Isolating Transformer 15 w 20/6.6A | 20 | each | |
60 | 22.06 | Isolating Transformer 15 w 6.6/6.6A | 20 | each | |
61 | 22.07 | Isolating Transformer 300W 6.6/6.6A | 10 | each | |
62 | 23 | Supply of LENS | BI01010001010000000000000515BI0100001112 | ||
63 | 23.01 | 360 Clear inner lens /Filters | 50 | each | |
64 | 23.02 | 180 deg inner lens filters | 10 | each | |
65 | 23.03 | 180 deg Red lens filters | 10 | each | |
66 | 23.04 | 180 deg Green lens filters | 10 | each | |
67 | 23.05 | 180 deg yellow lens/filter | 10 | each | |
68 | 23.06 | Ommi- directionol blue lens Suitable for MIRL | 10 | each | |
69 | 23.07 | 180 deg Black Sheild | 10 | each | |
70 | 23.08 | 180 Yellow Filter (convetional Type ) | 10 | each | |
71 | 23.09 | Red Filter for papi | 10 | each | |
72 | 23.1 | Red Spreader lens for end light fiting | 10 | each | |
73 | 23.11 | Green Spreader lens For threshold light fiting | 10 | each | |
74 | 23.12 | 360 Clear outer dome for HIRL fitring | 50 | each | |
75 | 24 | Supply of Airfield/Runway Cable | BI01010001010000000000000515BI0100001112 | ||
76 | 24.01 | 1x6 sq.mm Airfiled Lieilrting cable | 500 | mtrs | |
77 | 24.02 | 1x16 sq.mm Airfiled Lieilrting cable | 500 | mtrs | |
78 | 25 | Sub Head - 5 DSR Works\nPercentage above or below on the rates of DSR'2018(CPWD )-Electrical items worth totaling to Rs.15,00,000.00 as per requirement.\n(Note: The firm has to quote/upload the Percentage above/ below (+/- %) on the quantity mentioned against this item directly in the form of multiplying factor in the rate coloumn as clarified below:\nFor Example: If desired to quote 5% above on SR-2018 rates, the rate column shall be filled as 1.05. \nIf desired to quote 3% below on SR-2018 rates, the rate column shall be filled as 0.97.) | 1.5e+06 | % Above or Below |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy